Haier RG-61A user guide manual

C M Y CM MY CY CMY K
0010562911
TEMPERATURE
1
2
3
4
10
9
8
7
65
FAN ONLY
COOL
MAX COOL
SPEED
LOWHI
OFFON
Wait 3 Minutes Be ore
Restarting
POWER
RG-61A
C M Y CM MY CY CMY K
C M Y CM MY CY CMY K
1
C M Y CM MY CY CMY K
C M Y CM MY CY CMY K
1
1
2
4
4
5
5
6-7
8-13
8
8-13
14-18
15 15
16-18
19-20
20-21
C M Y CM MY CY CMY K
Test power plug before each use:
1. Press reset button. 2 . Press test button, unit should trip.
3. Press reset button again for use . Do not use if above test fail. In the event this device trips , the cause of the malfunction is to be corrected before further use of the device .
Important:
C M Y CM MY CY CMY K
5
5
C M Y CM MY CY CMY K
6
2 way
airflow
control paneleasy access filters
MODEL: RG-61A
TEMPERATURE
1
2
3
4
10
9
8
7
65
FAN ONLY
MIN
COOL
MAX COOL
SPEED
LOWHI
OFFON
Wait 3 Minutes Before
Resta ting
POWER
2. MODE Set Switch
5. How The Unit Drains
C M Y CM MY CY CMY K
7
Fig. # 1
TEMPERATURE
1
2
3
4
10
9
8
7
65
FAN ONLY
MIN
COOL
MAX COOL
SPEED
LOWHI
OFFON
POWER
C M Y CM MY CY CMY K
8
Also when you shut off the air conditioner wait for 3 minutes before turning it on again.
POWER Turns air conditioner off. SPEED "LOW" Low speed fan operation with cooling or not. SPEED "HI" High speed fan operation with cooling or not.
This automatically controls the temperature of indoor air. Turn the knob so that arrow points to the cooler marks for more moderate cooling.
Normal Fan
1. Turn the SPEED mode switch to the "HI" or the "LOW" setting.
2. Set the thermostat control to the temperature mark "FAN ONLY".
Normal cooling
1. Turn the SPEED mode switch to the "HI" or the "LOW" setting.
2. Set the thermostat control to the desire temperature (the mid-point is a good starting position). If the room temperature is not satisfactory after a reasonable time, adjust the control to a warmer or cooler setting, as appropriate.
Maximum cooling
1. Turn the SPEED mode switch to the "HI" setting
2. Set the thermostat control to the MAX COOL temperature mark.
Quieter operation
1. Turn the SPEED mode switch to the "LOW" setting.
2. Set the thermostat control as needed.
CAUTION:
1
2
3
C M Y CM MY CY CMY K
9
C M Y CM MY CY CMY K
10
window seal gasket
short screws 13/32"
wood screws 31/32"
Model:RG-61A
top rail
C M Y CM MY CY CMY K
11
Insert the side curtains into the top and bottom rails of the air conditioner. Fasten the curtains to the unit with 8 short screws 13/32".
Install top rail with 3 short screws13/32".
ASSEMBLE CURTAINS/TOP RAIL
TEMPERATURE
1
2
3
4
10
9
8
7
65
FAN ONLY
MN
OOLMAOOL
PEE
LO
OFFON
Wi 3 Mi t B f
R t ti
POER
RG 61A
12
3 5
13
3 8
36
22
12
7
16
18
9
16
14
11 16
5
3
25
1 2
C M Y CM MY CY CMY K
12
1. This unit is designed for installation in standard double hung windows with actual opening widths of 22
to 36 . The upper and lower sash
must open sufficiently to allow a clear vertical opening of 14
from the
bottom of the sash to the window sill.
2. If storm window presents interference, fasten a 2
wide wood strip(not included) (OUTER SILL) to the inner window sill across the full width of the sill. The wood strip should be thick enough to raise the height of the window sill so that the unit can be installed without interference by the storm window frame (STORM WINDOW FRAME) or wood strip (OUTDOORS) to help condensation to drain properly to the outside.
3. Install a second wood strip (approximately 6
long by 1-1/2 wide and same thickness as first strip) in the center of the outer sill flush against the back off the inner sill. This will raise basepan angle .
4. If the distance between STORM WINDOW FRAME and WOOD STRIP MOUNTED ON TOP OF INNER SILL is more than 1
, two of wood
strip are not necessary.
INNER
SILL
OUTER
SILL
I
N
D O O
R
S
O U
T D O O
R
S
WOOD STRIP MOUNTED ON TOP OF INNER SILL
WOOD STRIP FOR BASEPAN ANGLE
STORM WINDOW FRAME
1
MAX.
3/4
CLEARANCE
I N D
O O
R S
O U
T D O O
R
S
INNER
SILL
OUTER
SILL
LOCATING UNIT IN WINDOW
Open the window and mark center line on the center of the inner sill.
CENTER LINE
INNER SILL
INDOOR SIDE
ATTACH BASEPAN ANGLE
CENTER LINE
SHORT SCREW13/32"
INNER SILL
OUTER SILL
SHORT SIDE
BASEPAN ANGLE
8
8
OUTSIDE
INSIDE
Install the basepan angle behind the inner window sill, with the short side of basepan angle as shown. Use the 2 short screws13/32" provided. The basepan angle helps to hold unit securely in place. Be sure to place basepan angle edge flush against back of inner sill.
2
C M Y CM MY CY CMY K
13
INSTALL THE AIR CONDITIONER IN THE WINDOW
Carefully lift the air conditioner and slide it into the open window. Make sure the bottom guide of the air conditioner drops into the notches of the basepan angle. While steadying the air conditioner ,carefully bring the window sash down behind the upper guide of the air conditioner.
WINDOW FRAME
UPPER GUIDE
BOTTOM GUIDE
BASEPAN ANGLE
ABOUT 1/4
INSTALL THE SEAL GASKET AND SASH LOCK
Extend the side curtains to fill the window opening using 4 wood screws 31/32" to secure them. Cut the seal gasket to the window width. Stuff the sash seal between the glass and the window to prevent air and insects from getting into the room. Fasten the basepan angle, using a short screw13/32".
BASEPAN ANGLE
WINDOW SEAL GASKET
SHORT SCREW13/32"
WOOD SCREW31/32"
C M Y CM MY CY CMY K
14
The air filter behind the front grille should be checked and cleaned at least once every 2 weeks or more often if necessary.
To remove:
1. Open the inlet grille downward by pulling out the top of the inlet grille.
2. Remove the air filter from the front grille assembly by pulling the air filter up slightly.
3. Clean the filter with warm, soapy water below 40
o
C(104oF).
4. Rinse and gently shake the water from the filter and let it dry before replacing it.
Always use a soft cloth dampened with water or mild soap and water solution to wipe the front of the cabinet.
To clean the front panels or the cabinet DO NOT use harsh chemicals, abrasives, ammonia, chlorine, bleach, concentrated detergents, solvents or metal scouring pads.
DO NOT use your air conditioner without the air filter in place.
Always unplug your air conditioner before cleaning.
TEMPERATURE
PEED
LOW
OFF
POWER
1
2
3
4
10
9
8
7
65
FAN ONLY
MN
COOL
MAX COOL
C M Y CM MY CY CMY K
15
C M Y CM MY CY CMY K
16
(see page 8)
(see page 18)
Loading...