Haier Platinum Series Operation Manual

Please read this operation manual before using the air conditioner.
Keep this operation manual for future reference.
SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL
001053
Platinum Series Manual
Contents
PARTS AND FUNCTIONS OPERATION
MAINTENANCE CAUTIONS
TROUBLE SHOOTING
Loading of the battery
1 2
3
4
Parts and Functions
Indoor Unit
Remote controller
Remove the battery cover;
Load the batteries as illustrated.
2 R-03 batteries, resetting key
(cylinder);
Be sure that the loading
is in line with th
e" + "/"-";
Load the battery,then put on the cover again.
The distance between the signal transmission head and the rece­iver hole should be within 7m without any obstacle as well.
When electronic-started type fluorescent lamp or change- over
wireless telephone is installed in the
ver is apt to be disturbed in receiving
the signals,
so the distance to the indoor unit should be shorter.
type fluorescent lamp or room, the recei
Note:
Full display or unclear display during operation indicates the
ries have been used up.
Please change batteries.
If the remote controller can't run normally during operation, please
reload several minutes later.
batte
remove the batteries and
Hint: Remove the batteries in case won't be in use for a long period. If there is any display after taking-out, just press reset key.
1
POWER/SOFT button is not available for 09k12k.
1
2
3
5
8
7
6
5
4
Operation
Air Flow Direction Adjustment
Base Operation
1.Status display of air flow
Emergency operation and test operation
Emergency Operation:
Use this operation only when the remote controller is defective or lost, and with function of emergency running, air conditoner can run automatically for a while. When the emergency operation switch is pressed, the " Pi " sound is heard once, which means the start of this operation. When power switch is turning on for the first time and emergency operation starts, the unit will run automatically in the following modes:
Room temperature
Designated temperature
Timer mode
Fan
speed
Operation
mode
Above 23oC
Below 23
o
C 23oC
26
o
C
No
AUTO
AUTO
COOL
HEAT
No
It is impossible to change the settings of temp. and fan speed,It is also not possible to operate in timer or dry mode.
temperature is below 16
o
C, do not use it in the
Test operation:
Use this switch in the test operation when the room
normal operation.
your finger from the switch: the cooling
Continue to press the test operation
switch for more than 5 seconds . After
you hear the "Pi" sound twice,
release
Test ope ration switch is the same as emergency switch.
operation starts with the air flow speed "Hi".
Under this operation mode,the fan motor of indoor
unit will run in high speed.
2
Pi
Pi Pi
AUTO COOL DRY FAN
2.Select operation mode
Press FAN SPEED button. For each press, fan speed
follows:
Press MODE button. For each press, operation mode changes as follows:
Remote controller:
Remote controller:
Press button
Every time the button is pressed, temp.setting increase 1
o
C,if kept depressed, it will increase
rapidly
Every time the button is pressed, temp.setting
decrease 1
o
C,if kept depressed, it will decrease
rapidly
Select a desired temperature.
4.Fan speed selection
3.Select temp.setting
Air conditioner is running under displayed fan speed. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.
LOW
MED
HI
AUTO
1. Unit start
Press ON/OFF on the remote controller, unit starts.
TEMP+
TEMP-
TEMP+
TEMP-
/
Remote controller
changes as
Operation Mode
AUTO
etomeR
rellortnoC
Note
COOL
DRY
FAN
In DRY mode, when room temperature becomes lower than temp.setting+2
o
C,unit will run intermittently
at LOW speed regardless of FAN setting.
Under the mode of auto operation, air conditioner will automatically select Cool or Heat operation according to room temperature.
air conditioner
automatically adjusts the fan speed
temperature.
When FAN is set to AUTO, the
according to room
In FAN operation mode, the unit will not operate in COOL or HEAT mode but only in FAN mode ,AUTO is not available in FAN mode.And temp.setting is disabled. In FAN mode,SLEEP operation is not available.
Display
Board
next time,just press ON/OFF button and unit will run in previous status.
Remote controller can memorize each operation status. When starting it
Vertical flap
Pos.1
Pos.2
Pos.3
Pos.4
Pos.5
(Auto swing)
When restart after remote turning off, the remote
memorize the previous
Move the vertical blade by a knob on air
to adjust left and right direction referring to Fig.
2.Left and right air flow adjustment
(manual)
Cautions:
When adjusting the flap by hand,turn off the unit.
When humidity is high,condensate water might occur
adjusted to left
It is advisable not to keep horizontal flap at downward position for a long time in COOLor DRY
mode ,otherwise, condensate water might occur.
conditioner
at air outlet if all vertical louvers are or right.
controller will automatically
Note:
set swing position.