Haier KC18AGH, SAP-K18AM User Manual

INSTRUCTION MANUAL
FIRST MADE FOR SAP-KC18AM, KC18AGH
MATERIAL OR MODEL *PAPER-JO
DIMENSION OR MAKER WOODFREE 80gm
COLOR BLACK Print
EZIS4AETON
APPROVALS
N.Yamazaki
CHECK Tai C.S
2009/Nov /25
DESIGN
Tai C S
2009/Sep/08
DRAWN
REMARKS:
SAMS ONLY
Tai C.S
A
1
PART CODE
PART NAME
22 Dec 09
P.g 33, additional Flare Nut
85S-6-4181-002-00-0
EXPLANATORY BOOKLET
1
ON.RSNOISIVERETADSLAVORPPA
INSTRUCTION MANUAL
Split System Air Conditioner
INDOOOR UNIT OUTDOOR UNIT
COOL / DRY MODEL
HEAT PUMP MODEL
SAP-K18AM / AMS
SAP-C18AM / AMS
SAP-K18AGH SAP-C18AGH
HA1-PHA21K-PAS
Save These Instructions!
Pub. OI-85264181002000 © SANYO 2010
SANYO Electric Co., Ltd.
Instruction Manual
Instruction Manual
Contents
Page
Operation and Maintenance
1. Notices for operation .............................................................
2. Notices for user ................................................................
3. Names and functions of each part ....................................
4. Operation of wireless remote control unit ..........................
5. Clean and care .................................................................
6. Troubleshooting ................................................................
Installation Service
7. Notices for installation ...........................................................
8. Installation dimension diagram . ........................................
9. Install indoor unit ..............................................................
10. Install outdoor unit ...........................................................
11. Pump down ....................................................................... 34
12. Check after installation and Test operation ......................
2 4 6 7 16 18
21 23 24 28
35
Product Information
If you have problems or questions concerning your Air Conditioner, you will need the following information. Model and serial numbers are on the nameplate on the bottom of the cabinet.
Model No. _______________Serial No. _______________
Date of purchase _______________________________________
Dealer’s addres _______________________________________
Phone number_________________
Thank you for choosing SANYO air conditioner, please read this instruction manual carefully before operating the unit and keep it carefully for consultation.
______
Alert Symbols
The following symbols used in this manual, alert you to potentially dangerous conditions to users, service personnel or the appliance:
This symbol stands for the items should be forbidden.
This symbol stands for the items should be followed.
1
Operation and Maintenance
1. NOTICES FOR OPERATION
Each unit must be properly grounded with a ground (or earth) wire or through the supply wiring.
If not, please ask the qualified personnel to install. Furthermore, do not connect each wire to the gas pipe,water pipe, drainage pipe or any other improper places.
Don't leave windows and doors open for a long time while operating the air conditioner.
Don't attempt to repair the air
conditioner by yourself.
The wrong repair will lead to an electric shock or fire, so you should contact the SANYO service center for repair.
Don't block the air intake or outlet vents of both the outdoor and indoor units.
Select the most appropriate
temperature.
Keep room cooler than
outside about
o
C.
5
It can help to preclude the electricity wasted.
Never use or store gasoline or other flammable vapor or liquid near the air conditioner.
EG
It can decrease the air conditioning capacity.
Please make sure whether the installed stand is firm enough or not.
If it is damaged, it may lead to the fall of the unit and cause the injury.
It can decrease the air conditioning capacity or cause a malfunction.
Do not step on the top of the
outdoor unit or place things on it.
As falling off the outdoor unit can be dangerous.
It is very dangerous and it may cause a fire or explosion.
If abnormal phenomenon (like burning odor, etc) occur, turn off power supply and contact SANYO service center.
Cut Off Power
If abnormal phenomenon Icontinues, the unit may be damaged and cause electric shock or fire.
2
Operation and Maintenance
1. NOTICES FOR OPERATION
Do not use the air conditioner for other purposes,such as drying clothes, preserving foods, etc.
Do not insert your hands or stick into the air intake or outlet vents.
Do not place a space heater near the air conditioner. CO toxicosis may occur as a result of imcomplete burning.
Do not blow the wind to animals and plants directly. It can cause a bad influence to them.
Splashing water on the air conditioner can cause electric shock or malfunction.
Do not apply the cold wind to the body for a long time. It can cause the health problems.
Adjusting the airflow direction correctly.
a) Horizontal: The horizontal airflow can be adjusted by moving the louver with your hand to the left or right.
Louver of left / right direction.
b) Vertical: The vetical air flow can be adjusted by moving the flap
OPER
FAN
with the remote control unit. Use the SWING button to set
Flap of upward / downward position.
C
SWING
AM ON
E
MOD
+
ON/OFF
P EM T
­MP E T
G
SWIN
K
N
C
A
O
L
F
C
F
P
F E E
O
-
L
T
S
+
N O
-
ME
I
T
T
L NCE CA
­ME TI
either the auto sweep or set to the recommended position.
3
Operation and Maintenance
2. NOTICES FOR USER
2.1 Working Principle and Special Functions for Cooling
2.2 Working Principle and Special Functions for Heating (Heat Pump Model Only)
Principle:
Air conditioner absorbs heat in the room and transmit to outdoor and discharged, so that indoor ambient temperature decreased. It's cooling capacity will decrease by the increase of outdoor ambient temperature.
Anti-freezing Function:
If the units is running in COOL mode and in low temperature, there will be frost formed on the heat exchanger, when indoor heat exchanger temperature decreased below 0 C, the indoor unit micro-computer will stop compressor running and protect the unit.
Principle:
1. Air conditioner absorbs heat from the outdoor and transmit to indoor and evaporated, so that indoor temperature increased. Its heating capacity will decrease by the decrease of outdoor ambient temperature.
2. If outdoor temperature got lower, please operate with
other heating ventilating equipments.
o
EG
Defrosting:
1. When outdoor temperature is low but high humidity, after a
long while running, frost will form on outdoor unit, that will effect the heating effect. At this time, the auto defrosting function will act, and the heat running will stop for 8-10 minutes.
2. During the auto defrosting function, both the fan motors of indoor unit and outdoor unit will stop operate.
3. During the defrosting function, the indoor indicator flashes and the outdoor unit may emit vapor. This is due to the defrosting, it is not malfunction.
4. After defrosting finished, the heating will recover
automatically.
Cold Draft Prevention:
In "HEAT" mode, the indoor blower will no act at the following 3 status, while the heat exchanger haven't achieve the certain temperature. This is to prevent cool air blowing. (Within 2 minutes).
1. Heating starts.
2. After auto defrosting finished.
3. Heating under low ambient temperature.
Gentle Breeze
In the following situation, the indoor unit may blow gentle
breeze, and the guide louver rotate to a certain position:
1. In “Heat” mode, the unit turned on, the compressor does not arrive the starting condition
2. In “Heat” mode, the temperature arrive at the setting value and the compressor stop running about 1min.
4
Operation and Maintenance
2. NOTICES FOR USER
2.3 Working Temperature Range
Temperature Indoor air temperature Outdoor air temperature
Max.
COOLING
Min.
Max.
HEATING
Min.
The operating temperature range (outdoor temperature) for cooling unit is 21 °C ~ 43 °C; for cooling and heating unit is -5 °C ~ 43 °C.
32 °C DB / 23 °C DB
21 °C DB / 15 °C DB
27 °C DB / ---
20 °C DB / ---
43 °C DB / 26 °C DB
21 °C DB / ---
24 °C DB / 18 °C DB
-5 °C DB / -6 °C DB
2.4 The Conditions of Unit Can't Operate Normally.
In the following temp. range, the protection device may act, this may cause unit stop running.
“HEAT” running
“COOL” running
Outdoor temperature
above
24°C
43°C
Outdoor temperature
below
-7°C
21°C
Indoor temperature
above
27°C
---
“DRY” running
Under the relative humidity is above 80% ( doors and windows are opened) when cooling or dehumidifying for a long time, there may have dew drip off near the air vent.
18°C
--- ---
5
S/n
)
cable
)
e c
l
)
)
er
)
Silver Ion Filter
)
)
dica
Cool
Dry
Fa
Heat
Ru
S
)
Wall Pipe
)nd T
)
e
)
e
Operation and Maintenance
3. NAMES AND FUCTIONS OF EACH PART
Indoor Unit
Air intake
(1)
(3)
(10)
(9)
(4)
(6)
Air outlet
*(5) x 2pcs
Back side of part (4)
(7) (8)
The pattern in displayer:
CoolDryFanHeat
Run
Set temp.
Air inlet
(2)
Wireless
remote control
Outdoor Unit
art Name 1 2
(3
4 5
6
7)Receiver 8
ower
mot
ront Panel
t
*Only for SAP-K18AMS
uide Louver
n
ontro
tor
(11)
n
n
et Temp.
9
10 11
Drainage Pipe
(13)
Air outlet
(12)
12
13)
ape
onnection Wir
onnection Pip
6
Operation and Maintenance
4. OPERATION OF WIRELESS REMOTE CONTROL UNIT
4.1 Remote Control Unit (Display)
Displayed when transmitting data
Displayed when setting temperature
Displayed the clock
(1) Operation mode
AUTO ..........................
COOL ..........................
DRY.......... ....................
FAN .............................
Symbols
(4) Timer
(5) Sleep ..............................
(6) Confirmation of ..............
transmission
Displayed when setting timer
24-hour ON Timer .........
ON
24hour OFF Timer .........
OFF
OPER
HEAT ............................
(Heat Pump model Only)
(2) Fan speed
Automatic operation .....
HIGH ............................
MID...............................
LOW ............................
(3) Set temperature
16 – 30 °C
When set to 23 °C ...
7
AUTO
F
C
(7) Clock indication ............
(8) Sweep indication ............
(9) Light .............................
(10) Blow .............................
(11) Turbo ...........................
(12) TEMP ...........................
(13) Lock ............................
EG
4. OPERATION OF WIRELESS REMOTE CONTROL UNIT
Operation and Maintenance
4.2 Remote Control Unit (Functions)
Signal Transmitter
Display
ON/OFF operation button
TEMP. setting button
FAN SPEED Selector button
CLOCK button
BLOW button
TURBO button
SLEEP button
Transmitter
Display
ON/OFF operation
MODE selector button
(AUTO)
(COOL)
(DRY) (FAN)
(HEAT)
MODE operation button
TEMP button
SWING button
TIMER ON button
TIMER OFF button
LIGHT button
When you press the buttons on the remote control unit, the mark appears in the display to transmit the setting changes to the receiver in the air conditioner.
Information on the operating conditions is displayed while the remote control unit is switched on. If the unit is turned off, only CLOCK and TEMP was displayed.
This button is for turning the air conditioner ON and OFF.
To select “AUTO” “COOL”, “DRY” “FAN” or “HEAT” mode.
: When choosed this setting, the air conditioner calculates thedifference between the thermostat setting and the room temperature and automatically switches to the “COOL” or “HEAT” mode as appropriate. : The air conditioner makes the room cooler. : The air conditioner reduces the humidity in the room. : The air conditioner run the indoor fan only. : The air conditioner makes the room warmer.
OPER
(+) / (-) setting buttons
LOCK / UNLOCK button
TIMER ON button
TIMER OFF button
+
: Press the (+) button to increase set temperature, continue press 2 seconds for fast increasing set temperature.
-
: Press the (-) button to reduce set temperature, continue press 2 seconds for fast reducing set temperature.
-
: Press the button at the same time to lock or unlock wireless remote controller.
: The air conditioner starts at the set time.
: The air conditioner stops at the set time.
+
8
Operation and Maintenance
4. OPERATION OF WIRELESS REMOTE CONTROL UNIT
4.2 Remote Control Unit Functions (Continued)
FAN SPEED selector button
TEMP button
NOTE
BLOW button
AUTO
: The air conditioner automatically decides the fan speeds. : Low fan speed. : Medium fan speed. : High fan speed.
AUTO
Press to see set temperature or indoor temperature which show on the indicator lamp according to customer requirement.
: Display the presetting temperature. : Display the indoor ambient temperature (5 seconds) It will display the ambient temperature for 5 seconds,
After 5s later, then will back to display the presetting temperature.
: Current displaying status will not be changed.
No Icon : Default to display the pesetting temperature.
Press to begin or stop indoor fan from blowing indoor components to dry. This function applicable to “COOL” & “DRY” mode only. In “AUTO”, “FAN” as well as “HEAT” mode, “BLOW” function can not be set up and there is no “BLOW” displaying.
LIGHT button
TURBO button
SLEEP button
CLOCK Button
SWING Button
Press this button will turn ON / OFF the display of indicator light.
Press to quickly cool or heat the room with intense cool or hot air.
For details, see “SLEEP MODE” (P.g 12). When you press this button in the“DRY” or “COOL” mode, the mark appears in the display, and the remote control unit will automatically adjust the set temperature to save energy.
Use this button to set the clock.
How it Works?
Press clock button, signal blink and display. Within 5 seconds, the value can be adjusted by pressing “+” or “-” button, if press this button continuously for 2 seconds and above, in every 0.5 seconds, the value on ten place of Minute will be increased 1. During blinking, repress the Clock button, signal will be constantly displayed and it denotes the setting succeeded. After powered on, 12:00 is defaulted to display and signal will be displayed. If there is signal be displayed that denotes the current time value is Clock value, otherwise it is a Timer value.
To set the air swing direction which circurlarly change as:
OFF
NOTE
9
When the guide louver start to swing up and down, if turn off the Swing, the air guide louver will stop at the current position. (refer P.g 14 for more detail)
Operation and Maintenance
4. OPERATION OF WIRELESS REMOTE CONTROL UNIT
4.3 Using the General Operation
NOTE
STEP 1
STEP 3
STEP 4
Press the setting buttons as described below and change the settings as desired.
STEP 1
STEP 2
To start the air conditioner, press the ON/OFF operation button.
Press the MODE selector button and select the desired mode. For DRY operation For COOLING operation For FAN only operation For AUTO operation For HEATING operation
   →    →
    →
   →
(Only for Heat Pump Model)
STEP 2
STEP 5
STEP 3
STEP 4
NOTE
STEP 5
Press the TEMP. setting buttons to change the temperature setting to the desired temperature. Adjustable temperature range: 30 °C (86 °F) max.—16 °C (61 °F) min. Under “AUTO” operation, the temperature can not be adjust. Under “HEAT” operation, the initial value is 28 °C (82 °F); Under other operation, the initial value is 25 °C (77 °F).
Set the FAN SPEED selector button to the setting you want.
AUTO
Under Dry mode, the fan speed is automatically set to LOW.
Press the automatically
To STOP the air conditioner, press the ON/OFF operation button again.
: Auto fan speed. : Low fan speed.
: Middle fan speed. : High fan speed.
button and set the air blow direction as desired or

.
10
Loading...