Product Information
If you have problems or questions concerning your Air Conditioner,
you will need the following information. Model and serial numbers
are on the nameplate on the bottom of the cabinet.
Model No. _______________Serial No. _______________
Date of purchase _______________________________________
Thank you for choosing SANYO air conditioner, please read
this instruction manual carefully before operating the unit
and keep it carefully for consultation.
______
Alert Symbols
The following symbols used in this manual, alert you to
potentially dangerous conditions to users, service personnel
or the appliance:
This symbol stands for the items should be forbidden.
This symbol stands for the items should be followed.
1
Operation and Maintenance
1. NOTICES FOR OPERATION
Each unit must be
properly grounded with a
ground (or earth) wire or
through the supply wiring.
If not, please ask the qualified
personnel to install.
Furthermore, do not connect
each wire to the gas pipe,water
pipe, drainage pipe or any other
improper places.
Don't leave windows and doors
open for a long time while operating
the air conditioner.
Don't attempt to repair the air
conditioner by yourself.
The wrong repair will lead to an
electric shock or fire, so you
should contact the SANYO
service center for repair.
Don't block the air intake or outlet
vents of both the outdoor and indoor
units.
Select the most appropriate
temperature.
Keep room
cooler than
outside about
o
C.
5
It can help to preclude the
electricity wasted.
Never use or store gasoline or
other flammable vapor or liquid
near the air conditioner.
EG
It can decrease the air
conditioning capacity.
Please make sure whether
the installed stand is firm
enough or not.
If it is damaged, it may lead to
the fall of the unit and cause the
injury.
It can decrease the air conditioning
capacity or cause a malfunction.
Do not step on the top of the
outdoor unit or place things on it.
As falling off the outdoor unit can
be dangerous.
It is very dangerous and it may
cause a fire or explosion.
If abnormal phenomenon (like
burning odor, etc) occur, turn off
power supply and contact
SANYO service center.
Cut Off
Power
If abnormal phenomenon
Icontinues, the unit may be
damaged and cause electric
shock or fire.
2
Operation and Maintenance
1. NOTICES FOR OPERATION
Do not use the air conditioner for other
purposes,such as drying clothes,
preserving foods, etc.
Do not insert your hands or stick into
the air intake or outlet vents.
Do not place a space heater near the air
conditioner. CO toxicosis may occur as
a result of imcomplete burning.
Do not blow the wind to animals and
plants directly. It can cause a bad
influence to them.
Splashing water on the air conditioner
can cause electric shock or malfunction.
Do not apply the cold wind to the body
for a long time. It can cause the health
problems.
Adjusting the airflow direction correctly.
a) Horizontal:
The horizontal
airflow can be
adjusted by
moving the
louver with
your hand
to the left
or right.
Louver of left /
right direction.
b) Vertical:
The vetical air
flow can be
adjusted by
moving the flap
OPER
FAN
with the remote
control unit.
Use the SWING
button to set
Flap of upward /
downward position.
C
SWING
AM
ON
E
MOD
+
ON/OFF
P
EM
T
MP
E
T
G
SWIN
K
N
C
A
O
L
F
C
F
P
F
E
E
O
-
L
T
S
+
N
O
-
ME
I
T
T
L
NCE
CA
ME
TI
either the auto
sweep or set to the
recommended position.
3
Operation and Maintenance
2. NOTICES FOR USER
2.1 Working Principle
and Special
Functions for
Cooling
2.2 Working Principle
and Special
Functions for
Heating
(Heat Pump
Model Only)
Principle:
Air conditioner absorbs heat in the room and transmit to
outdoor and discharged, so that indoor ambient temperature
decreased. It's cooling capacity will decrease by the increase
of outdoor ambient temperature.
Anti-freezing Function:
If the units is running in COOL mode and in low temperature,
there will be frost formed on the heat exchanger, when
indoor heat exchanger temperature decreased below 0 C,
the indoor unit micro-computer will stop compressor running
and protect the unit.
Principle:
1. Air conditioner absorbs heat from the outdoor and transmit
to indoor and evaporated, so that indoor temperature
increased. Its heating capacity will decrease by the
decrease of outdoor ambient temperature.
2. If outdoor temperature got lower, please operate with
other heating ventilating equipments.
o
EG
Defrosting:
1. When outdoor temperature is low but high humidity, after a
long while running, frost will form on outdoor unit, that will
effect the heating effect. At this time, the auto defrosting
function will act, and the heat running will stop for 8-10
minutes.
2. During the auto defrosting function, both the fan motors of
indoor unit and outdoor unit will stop operate.
3. During the defrosting function, the indoor indicator flashes
and the outdoor unit may emit vapor. This is due to the
defrosting, it is not malfunction.
4. After defrosting finished, the heating will recover
automatically.
Cold Draft Prevention:
In "HEAT" mode, the indoor blower will no act at the
following 3 status, while the heat exchanger haven't achieve
the certain temperature. This is to prevent cool air blowing.
(Within 2 minutes).
1. Heating starts.
2. After auto defrosting finished.
3. Heating under low ambient temperature.
Gentle Breeze
In the following situation, the indoor unit may blow gentle
breeze, and the guide louver rotate to a certain position:
1. In “Heat” mode, the unit turned on, the compressor does
not arrive the starting condition
2. In “Heat” mode, the temperature arrive at the setting
value and the compressor stop running about 1min.
4
Operation and Maintenance
2. NOTICES FOR USER
2.3 Working Temperature Range
TemperatureIndoor air temperatureOutdoor air temperature
Max.
COOLING
Min.
Max.
HEATING
Min.
The operating temperature range (outdoor temperature) for cooling unit is 21 °C ~ 43 °C;
for cooling and heating unit is -5 °C ~ 43 °C.
32 °C DB / 23 °C DB
21 °C DB / 15 °C DB
27 °C DB / ---
20 °C DB / ---
43 °C DB / 26 °C DB
21 °C DB / ---
24 °C DB / 18 °C DB
-5 °C DB / -6 °C DB
2.4 The Conditions of Unit Can't Operate Normally.
In the following temp. range, the protection device may act, this may cause unit stop
running.
“HEAT” running
“COOL” running
Outdoor temperature
above
24°C
43°C
Outdoor temperature
below
-7°C
21°C
Indoor temperature
above
27°C
---
“DRY” running
Under the relative humidity is above 80% ( doors and windows are opened) when cooling
or dehumidifying for a long time, there may have dew drip off near the air vent.
18°C
------
5
S/n
)
cable
)
e c
l
)
)
er
)
Silver Ion Filter
)
)
dica
Cool
Dry
Fa
Heat
Ru
S
)
Wall Pipe
)nd T
)
e
)
e
Operation and Maintenance
3. NAMES AND FUCTIONS OF EACH PART
Indoor Unit
Air intake
(1)
(3)
(10)
(9)
(4)
(6)
Air outlet
*(5) x 2pcs
Back side
of part (4)
(7) (8)
The pattern in displayer:
:Cool
:Dry
:Fan
:Heat
:Run
:Set temp.
Air inlet
(2)
Wireless
remote control
Outdoor Unit
art Name
1
2
(3
4
5
6
7)Receiver
8
ower
mot
ront Panel
t
*Only for
SAP-K18AMS
uide Louver
n
ontro
tor
(11)
n
n
et Temp.
9
10
11
Drainage Pipe
(13)
Air outlet
(12)
12
13)
ape
onnection Wir
onnection Pip
6
Operation and Maintenance
4. OPERATION OF WIRELESS REMOTE CONTROL UNIT
4.1 Remote Control Unit (Display)
Displayed when
transmitting data
Displayed when setting
temperature
Displayed the clock
(1) Operation mode
AUTO ..........................
COOL ..........................
DRY.......... ....................
FAN .............................
Symbols
(4) Timer
(5) Sleep ..............................
(6) Confirmation of ..............
transmission
Displayed when setting
timer
24-hour ON Timer .........
ON
24hour OFF Timer .........
OFF
OPER
HEAT ............................
(Heat Pump model Only)
(2) Fan speed
Automatic operation .....
HIGH ............................
MID...............................
LOW ............................
(3) Set temperature
16 – 30 °C
When set to 23 °C ...
7
AUTO
F
C
(7) Clock indication ............
(8) Sweep indication ............
(9) Light .............................
(10) Blow .............................
(11) Turbo ...........................
(12) TEMP ...........................
(13) Lock ............................
EG
4. OPERATION OF WIRELESS REMOTE CONTROL UNIT
Operation and Maintenance
4.2 Remote Control Unit (Functions)
Signal Transmitter
Display
ON/OFF operation button
TEMP. setting button
FAN SPEED Selector button
CLOCK button
BLOW button
TURBO button
SLEEP button
Transmitter
Display
ON/OFF operation
MODE selector button
(AUTO)
(COOL)
(DRY)
(FAN)
(HEAT)
MODE operation button
TEMP button
SWING button
TIMER ON button
TIMER OFF button
LIGHT button
When you press the buttons on the remote control unit, the
mark appears in the display to transmit the setting changes to
the receiver in the air conditioner.
Information on the operating conditions is displayed while the
remote control unit is switched on. If the unit is turned off, only
CLOCK and TEMP was displayed.
This button is for turning the air conditioner ON and OFF.
To select “AUTO” “COOL”, “DRY” “FAN” or “HEAT” mode.
: When choosed this setting, the air conditioner calculates
thedifference between the thermostat setting and the room
temperature and automatically switches to the “COOL” or
“HEAT” mode as appropriate.
: The air conditioner makes the room cooler.
: The air conditioner reduces the humidity in the room.
: The air conditioner run the indoor fan only.
: The air conditioner makes the room warmer.
OPER
(+) / (-) setting
buttons
LOCK / UNLOCK
button
TIMER ON button
TIMER OFF button
+
: Press the (+) button to increase set temperature, continue
press 2 seconds for fast increasing set temperature.
-
: Press the (-) button to reduce set temperature, continue
press 2 seconds for fast reducing set temperature.
-
: Press the button at the same time to lock or unlock
wireless remote controller.
: The air conditioner starts at the set time.
: The air conditioner stops at the set time.
+
8
Operation and Maintenance
4. OPERATION OF WIRELESS REMOTE CONTROL UNIT
4.2 Remote Control Unit Functions (Continued)
FAN SPEED selector
button
TEMP button
NOTE
BLOW button
AUTO
: The air conditioner automatically decides the fan speeds.
: Low fan speed.
: Medium fan speed.
: High fan speed.
AUTO
Press to see set temperature or indoor temperature which show on
the indicator lamp according to customer requirement.
: Display the presetting temperature.
: Display the indoor ambient temperature (5 seconds)
It will display the ambient temperature for 5 seconds,
After 5s later, then will back to display the presetting
temperature.
: Current displaying status will not be changed.
No Icon : Default to display the pesetting temperature.
Press to begin or stop indoor fan from blowing indoor components
to dry. This function applicable to “COOL” & “DRY” mode only. In
“AUTO”, “FAN” as well as “HEAT” mode, “BLOW” function can not
be set up and there is no “BLOW” displaying.
LIGHT button
TURBO button
SLEEP button
CLOCK Button
SWING Button
Press this button will turn ON / OFF the display of indicator light.
Press to quickly cool or heat the room with intense cool or hot air.
For details, see “SLEEP MODE” (P.g 12). When you press this
button in the“DRY” or “COOL” mode, the mark appears in the
display, and the remote control unit will automatically adjust the set
temperature to save energy.
Use this button to set the clock.
How it Works?
Press clock button, signal blink and display. Within 5 seconds,
the value can be adjusted by pressing “+” or “-” button, if press this
button continuously for 2 seconds and above, in every 0.5 seconds,
the value on ten place of Minute will be increased 1. During
blinking, repress the Clock button, signal will be constantly
displayed and it denotes the setting succeeded. After powered on,
12:00 is defaulted to display and signal will be displayed. If there
is signal be displayed that denotes the current time value is
Clock value, otherwise it is a Timer value.
To set the air swing direction which circurlarly change as:
OFF
NOTE
9
When the guide louver start to swing up and down, if turn off
the Swing, the air guide louver will stop at the current
position. (refer P.g 14 for more detail)
Operation and Maintenance
4. OPERATION OF WIRELESS REMOTE CONTROL UNIT
4.3 Using the General Operation
NOTE
STEP 1
STEP 3
STEP 4
Press the setting buttons as described below and change the settings as desired.
STEP 1
STEP 2
To start the air conditioner, press the ON/OFF operation button.
Press the MODE selector button and select the desired mode.
For DRY operation
For COOLING operation
For FAN only operation
For AUTO operation
For HEATING operation
→
→
→
→
→
(Only for Heat Pump Model)
STEP 2
STEP 5
STEP 3
STEP 4
NOTE
STEP 5
Press the TEMP. setting buttons to change the temperature setting
to the desired temperature.
Adjustable temperature range:
30 °C (86 °F) max.—16 °C (61 °F) min.
Under “AUTO” operation, the temperature can not be adjust.
Under “HEAT” operation, the initial value is 28 °C (82 °F);
Under other operation, the initial value is 25 °C (77 °F).
Set the FAN SPEED selector button to the setting you want.
AUTO
Under Dry mode, the fan speed is automatically set to LOW.
Press the
automatically
To STOP the air conditioner, press the ON/OFF operation button again.
: Auto fan speed.
: Low fan speed.
: Middle fan speed.
: High fan speed.
button and set the air blow direction as desired or
.
10