Haier HYC-260, HYC-360, HYC-390F, HYC-890, HYC-940F Operation Manual

Pharmaceutical Refrigerator
Operation Manual
Model:
HYC-260
HYC-360
HYC-290
HYC-390
HYC-390F
HYC-610
HYC-890
HYC-940
HYC-940F
Checker:
Haier Medical and Laboratory Products Co., Ltd. Address: Haier Industrial Park, Economic Technology Development Zone. Qingdao 266510.P.R.China Web:www.haiermedical.com Version:1st,2017 Dedicated code:0270501031 V13026
Read the Operation Manual carefully before using your appliance. Keep the Operation Manual in a safe place. Appearance , color and layout of the door may vary. Translation of the original instruction. This product is only applicable for storage of pharmaceutical products or drugs. Not applicable for storage of blood or blood products including biological products, for example biological vaccine, agents for in vitro diagnosis and etc.
Certificate of Quality
EC Declaration of Conformity
according to the Machinery Directive 2006/42/EC
For the following equipment :
Product : Pharmaceutical Refrigerator
Manufactures Name : Haier Medical and Laboratory Products Co.,Ltd.
Manufactures Address : Haier Industrial Park, Economic Technology
Development Zone. Qingdao 266510.P.R.China
Refer to in this declaration confirms with the following directive(s)/standards:
2006/42/EC, EN60335-1, EN60335-2-89 EN62233
HYC-260
HYC-360
HYC-290
HYC-390
HYC-390F
HYC-610
HYC-890
HYC-940
HYC-940F
Haier
Type Designation/Trademark:
Packing List
Plastic bag
Key
Shelves
Label strip
Drain hole cap
Fixed card
Model
Operation Manual
HYC-360
HYC-260
HYC-290
1
2
4
4
1
16
1
1
2
5
5
1
20
1
1
2
5
5
1
/
1
Brackets
(for rear wall distance)
2
2
HYC-390
1
2
7
7
1
/
1
2
Pad lock /
Handle Kits
Power cord Kits
/
/
1/0
1/0
/
/
1
1
2
HYC-390F
1
2
7
7
1
/
1
2
1/1
1
Plastic bag
Key
Shelves
Model
Operation Manual
HYC-890
HYC-610
1
2
6
/
1
24
1
1
4
12
12
/
48
1
/
/
0/1 /
/
/
HYC-940
1
4
12
12
/
48
1
/
/
/
HYC-940F
1
4
12
12
/
48
1
/
/
Label strip
Drain hole cap
Fixed card
Pad lock /
Handle Kits
Power cord Kits
Brackets
(for rear wall distance)
45
Temperature
Control
Refrigeration
System
Safety System
User-friendly
Design
The unit is equipped with a computer control, digital display of temperature of 0.1 accuracy and a temperature range of 2 to 8.
Multi-fault alarm (high and low temperature alarm, low battery alarm,
power failure alarm, sensor error alarm and door ajar alarm)
Two alarm methods(Audible buzzer alarm and flashing indicator alarm)
All independent components are safely grounded
Refrigeration system is optimized with high quality hermetically sealed
compressors and other components for a high efficiency performance.
User-friendly design, computer control, smart and carefree, adjustment
not required. High performance thermal insulation.
Electric heated glass door with multiple anti-condensation
technologies(except HYC-260/360).
Automatic removal of condensate water.
Note: Technical information might be somewhat different on your refrigerator than published due to continuous improvement.
The product is applicable to pharmacies, pharmaceutical factories, quarantine stations, health
centers and hospitals, used to store pharmaceuticals, medicine and other related products which need a storage environment of 2~8.
1
44
Model
Rated voltage
VAC
Rated frequency
(Hz)
HYC-260 220~240 50/60 0.186 HYC-360 220~240 50/60 0.215 HYC-360 115 60 1.177 HYC-290 220~240 50/60 0.429 HYC-290 115 60 0.358 HYC-390 220~240 50/60 0.436 HYC-390 115 60 0.429
HYC-390F 220~240 50/60 0.436
HYC-610 220~240 50/60 0.601 HYC-610 115 60 0.501 HYC-890 220~240 50 0.358 HYC-940 220~240 50 0.472 HYC-940 220~240 60 0.615 HYC-940 115 60 0.458
HYC-940F 220~240 50 0.472
into the atmosphere.
GWP=global warming potential
Refrigerant type GWP
R134a 1430
Global Warming Potential
CO
2
equivalent
Tonnes
43
1
Product Feature........................................................
Content.....................................................................
Safety Precautions...................................................
Application guidelines..............................................
Product Installation ...................................................
Component Names Control Panel...........................
Application method ...................................................
Alarm........................................................................
Cleaning and Maintenance.......................................
FAQ..........................................................................
Circuit Diagram.........................................................
Specification&Packing List.......................................
2
3
6
7
13
21
29
31
33
34
39
Content:
2
HYC-940 HYC-940F
890L
Fin tube type / Fin tube type
R134a 330g
LED 9W
227kg 207kg
2~8
220-240V~/50Hz 220-240V~/60Hz
850W/4.5A
Glass door with electric heat
Force-air cooling circulation
Cold-rolled steel with power coated/Cold-rolled steel with power coated
Pharmaceutical Refrigerator
Exterior Dimensions
(W×D×H)
(mm)
Interior Dimensions
(W×D×H)
(mm)
Effective Volume
Door
Compressor
Shelves
Refrigerating Method
Exterior / Interior
Refrigerant
Net Weight
Rated Power/Current
Rechargeable Battery
High & low temperature alarm, sensor error alarm, power failure alarm,
low battery power alarm, door ajar alarm
DC 12V rechargeable battery
Name
Model
48 h (when the battery is fully charged)
Anti-shock Safety Classification
I
Power connection type
Y
Climate Type
4
Foaming Agent
CP/IP
Noise Level(Lp)
45dB(A)
770W/4.5A
115V~/60Hz
850W/11A
1130×755×1980
1030×590×1425
Note: Climate Type 4 means the temperature is +30,the relative humidity is 55%.Technical information may vary from the appliance that you have just purchased due to technical improvements.
R134a 430g R134a 320g
CFC-Free foamed-in-place urethane
High Quality Hermetically sealed compressor
Insulation
12 Polyester coated wire shelves
≤20kg per shelf
Load
Microprocessor controlled
Condenser/Evaporater
Interior light
Temperature Control
Temperature Range of sensor in glycerin bottle
Voltage
Alarm system
Battery duration for alarm system
R134a 330g
220-240V~/50Hz
600W/3A
Solid door
Specification
42
3
If the power cord needs to be lengthen, the cross section area of the extension line’s conductor should be at least 2 mm² and the length of the extension cord should be limited to 3 m. This is to prevent electric fire or shock.
The power cord of the unit is equipped with a 16 A three-prone power plug. Do not remove the ground pin of the power plug under any circumstances. Make sure the plug is securely plugged into the power outlet to prevent fire.
The power socket must be equipped with a ground wire to prevent electric shock. If the socket fails to be grounded, the ground wire must be installed before the refrigerator is plugged in.
The refrigerator shall not conduct outdoor service. Electrical leakage or shock may be caused if wet by rainwater.
Do not place the refrigerator in humid places or places where the unit may get splashed on by water. This is to avoid electric shock due to deterioration of insulation.
Dear users: Thanks for your choice of Haier pharmaceutical refrigerator, please make sure you have carefully
read and observed the contents with following signs in the manual, for better understanding of this
manual and better use of this product, so as to prevent personal injuries and refrigerator damage.
In case the fire, do not pour water onto the refrigerator unit as a means to prevent electric shock or short circuit.
When there is a leak of flammable gas, shutoff the feed valve of the gas. Open windows for ventilation and exhaust. Do not plug in your refrigerator or unplug your refrigerator as spark in these processes can cause an explosion or fire.
We recommend the unit be installed by a professional to avoid any electrical hazard.
Place the refrigerator on solid and flat ground to avoid tipping the unit over to cause personal injury.
Only connect the refrigerator unit with a dedicated power outlet specified by the nameplate of the unit. This is to avoid fire or electric shock.
If the supply voltage is lower than 198 V or higher than 242 V, an automatic voltage regulator of at least 4,000 W should be installed with the refrigerator.
Safety Precautions
Ignoring this warning may result in death or serious injury
Ignoring this warning may result in death or serious injury,and/or damage to the refrigerator and property
Actions or operations which are prohibited
Actions or operations which must be followed
HYC-890
890L
R134a 250g
LED 6W
227kg
2~8
220-240V~/50Hz
800W/4A
Glass door with electric heat
Force-air cooling circulation
Cold-rolled steel with power coated/Cold-rolled steel with power coated
Pharmaceutical Refrigerator
Effective Volume
Door
Compressor
Shelves
Refrigerating Method
Refrigerant
Net Weight
Rated Power/Current
Rechargeable Battery
High & low temperature alarm, sensor error alarm, power failure alarm,
low battery power alarm, door ajar alarm
DC 12V rechargeable battery
Name
Model
48 h (when the battery is fully charged)
Anti-shock Safety Classification
I
Power connection type
Y
Climate Type
4
Foaming Agent
CP/IP
Noise Level(Lp)
45dB(A)
1130×755×1980
1030×590×1425
Note: Climate Type 4 means the temperature is +30,the relative humidity is 55%.Technical information may vary from the appliance that you have just purchased due to technical improvements.
Exterior Dimensions
(W×D×H)
(mm)
Interior Dimensions
(W×D×H)
(mm)
Exterior / Interior
Insulation
Load
Condenser/Evaporater
Interior light
Temperature Control
Temperature Range of sensor in glycerin bottle
Voltage
Alarm system
Battery duration for alarm system
CFC-Free foamed-in-place urethane
High Quality Hermetically sealed compressor
12 Polyester coated wire shelves
≤20kg per shelf
Microprocessor controlled
Specification
Fin tube type / Fin tube type
41
Do not climb to the top of the refrigerator or place plastic bags on top of the refrigerator. This is to prevent tip over of the refrigerator, which can cause personal injury.
Do not use any metal objects such as iron nails or wires into holes, gaps or vents for internal air circulation. This is to prevent personal injury due to contact of articles behind the holes.
Do not place containers of water or heavy objects on the refrigerator. Falling objects may cause personal injury and overflown water may damage the insulation to cause electric shock and fire.
Do not ground the refrigerator through gas pipes, water supply pipes, telephone lines or lighting conductors. These types of connections can cause electric shock.
Do not touch electric parts such as power plugs or switches with wet hands to prevent electric shock.
When pulling the plug out of the power socket, hold the power plug instead of power cable. Pulling the cable can cause a damage and personal injury.
Unplug the refrigerator unit if it malfunctions to avoid fire or personal injury.
Dismantling, repairing and retrofitting a unit should only be performed by a professional to avoid personal injury.
Disconnect the refrigerator when repairs or maintenance are performed on the refrigerator to prevent electric shock or personal injuries.
Do not inhale airborne particles inside and near the refrigerator during routine maintenance. This is to avoid health hazard.
To avoid any potential danger to human health or environment, the refrigerator should be used in safe regions to store toxic, harmful or radioactive particles.
If the refrigerator is to be decommissioned, unplug the power cord to avoid electric shock, current leakage, or fire caused by aged power lines.
If the refrigerator is left unused in area where supervision is unavailable for a long time, make sure children are not near the unit and the door cannot be completely closed and locked.
End of life disposal of a unit should only be performed by a professional. Remove the door to avoid accidents such as suffocation.
Do not store flammable, explosive or volatile articles inside the refrigerator and do not use flammable sprays nearby. This is to avoid an explosion or a fire.
Do not store corrosive articles such acid or alkali in the refrigerator. These chemicals can damage internal components or electrical parts.
Do not place packaging plastic bags within the reach of children to prevent suffocation accidents.
4
HYC-610
780×840×1945
680×640×1400
610L
R134a 420g R134a 350g
LED 3W
43dB(A)
204kg
2~8
220-240V~/50Hz/60Hz
550W/3.5A
Glass door with electric heat
Force-air cooling circulation
Powder coated cold rolled steel/Stainless steel
Pharmaceutical Refrigerator
Effective Volume
Door
Compressor
Shelves
Refrigerating Method
Refrigerant
Net Weight
Rated Power/Current
Rechargeable Battery
High & low temperature alarm, sensor erroe alarm, power failure alarm,
low battery power alarm, door ajar alarm
DC 12V rechargeable battery
Name
Model
48 h (when the battery is fully charged)
Anti-shock Safety Classification
I
Power connection type
Y
Climate Type
4
Foaming Agent
CP/IP
Noise Level(Lp)
560W/7.5A
Fin tube type / Fin tube type
Note: Climate Type 4 means the temperature is +30,the relative humidity is 55%.Technical information may vary from the appliance that you have just purchased due to technical improvements.
Exterior Dimensions
(W×D×H)
(mm)
Interior Dimensions
(W×D×H)
(mm)
Exterior / Interior
Insulation
Load
Condenser/Evaporater
Interior light
Temperature Control
Temperature Range of
sensor in glycerin bottle
Voltage
Alarm system
Battery duration for alarm system
CFC-Free foamed-in-place urethane
High Quality Hermetically sealed compressor
6 Polyester coated wire shelves
≤30kg per shelf
Microprocessor controlled
Specification
40
Always check the settings in the controller after restarting a unit from a power outage or shut off. Change of settings may cause damage to the products stored.
If the power is shut off, let the unit sit for 5 minutes before it is powered up again to avoid damaging the compressor or the system.
Wear gloves when performing maintenance to prevent personal injury as a result of sharp edges or corners.
Hold the knob when closing the door to prevent finger pinching.
The angle of inclination shall not be greater than 45°when handling the refrigerator.
Be aware of the danger of tripping when working with the refrigerator to avoid managing the unit or personal injury.
Do not use the door knob to prevent refrigerator damage or personal injury.
Do not use electrical appliances inside the food storage compartments of the appliance, unless they are of the type recommended by the manufacturer.
Do not damage the refrigeration line.
Position the refrigerator to make sure the power plug is accessible.
The appliance must be placed on a solid and flat surface, or excessive vibration and noise may be produced when the appliance in operation.
The appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capacibilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
If the power supply cord is damaged, it should be replaced by a qualified technician to avoid a hazard condition.
Keep ventilation openings, in the appliance enclosure or in the built-in structure, clear of obstruction.
If your cabinet is to be discard, you must remove the door and leave the shelves in place. This will reduce the posibility of danger to children. And the flammable foaming needs to be disposed by professional persons.
CP/IP foaming materials are flammable, need professional processing.
HYC-390
665×710×1965
530×555×1380
390L
7
R134a 305g
LED 3W
116kg
2~8
220-240V~/50/60Hz
380W/2.4A
HYC-290
665×710×1665
530×555×1080
290L
5
Fin tube type / Plate type
Microprocessor controlled
R134a 300g
LED 3W
105kg
2~8
220-240V~/50/60Hz
340W/2.2A
Glass door with electric heat
Force-air cooling circulation
Cold-rolled steel sheet with powder coated /HIPS plate
Pharmaceutical Refrigerator
Effective Volume
Door
Compressor
Shelves
Refrigerating Method
Refrigerant
Net Weight
Rated Power/Current
Rechargeable Battery
High & low temperature alarm, sensor error alarm, power failure alarm,
low battery power alarm, door ajar alarm
DC 12V rechargeable battery
Name
Model
48 h (when the battery is fully charged)
Anti-shock Safety
Classification
I
I
Power connection type
Y
Y
Climate Type
4
4
Foaming Agent
CP/IP
CP/IP
Noise Level(Lp)
43dB(A)
43dB(A)
Note: Climate Type 4 means the temperature is +30,the relative humidity is 55%.Technical information may vary from the appliance that you have just purchased due to technical improvements.
665×710×1965
530×555×1380
390L
Solid Door
R134a 305g
106kg
220-240V~/50/60Hz
300W/2.4A
I
Y
7
LED 3W
2~8
4
CP/IP
43dB(A)
HYC-390F
115V~/60Hz 115V~/60Hz
460W/5.0A
R404a 250g
R404a 300g
500W/5.5A
≤26kg per shelf
≤26kg per shelf
≤26kg per shelf
47dB(A)
47dB(A)
Exterior Dimensions
(W×D×H) (mm)
Interior Dimensions
(W×D×H) (mm)
Exterior / Interior
Insulation
Load
Condenser/Evaporater
Interior light
Temperature Control
Temperature Range of sensor in glycerin bottle
Voltage
Alarm system
Battery duration for alarm system
CFC-Free foamed-in-place urethane
High Quality Hermetically sealed compressor
5
Specification
39
6
HYC-260
Pharmaceutical Refrigerator
Effective Volume
Door
Compressor
Shelves
Refrigerating Method
Refrigerant
Net Weight
Rated Power/Current
Rechargeable Battery
620×655×1720
550×460×1065
260L
Glass door
4 Polyester coated wire shelves
Force-air cooling circulation
Scratch resistant painted steel / HIPS
Wire tube type / Fin tube type
R134a 130g
Fluorescent lamp 15W
88kg
2
~8
220-240V~/50Hz/60Hz
300W/2.1A
High & low temperature alarm, sensor error alarm, power failure alarm,
low battery power alarm, door ajar alarm
DC 12V rechargeable battery
Name
Model
HYC-360
620×655×1995
550×460×1340
360L
R134a 150g
99kg
2
~8
48 h (when the battery is fully charged)
Anti-shock Safety Classification
I
I
220-240V~/50Hz/60Hz
315W/2.2A
Specification&Packing List
Specification
Glass door
5 Polyester coated wire shelves
Force-air cooling circulation
Scratch resistant painted steel / HIPS
Wire tube type / Fin tube type
Fluorescent lamp 15W
Power connection type
Y
Y
Climate Type
4
4
Foaming Agent
CP/IP
CP/IP
Noise Level(Lp) 43dB(A) 43dB(A)
Note: Climate Type 4 means the temperature is +30,the relative humidity is 55%.Technical information may vary from the appliance that you have just purchased due to technical improvements.
115V~/60Hz
340W/4.5A
R404a 300g
≤20kg per shelf
≤20kg per shelf
Exterior Dimensions
(W×D×H) (mm)
Interior Dimensions
(W×D×H) (mm)
Exterior / Interior
Insulation
Load
Condenser/Evaporater
Interior light
Temperature Control
Temperature Range of sensor in glycerin bottle
Voltage
Alarm system
Battery duration for alarm system
Microprocessor controlled
CFC-Free foamed-in-place urethane
High Quality Hermetically sealed compressor
Microprocessor controlled
47dB(A)
To reduce the possibility of temperature fluctuation in the refrigerator, please attempt to cut down
the time to open to the door to remove and load products.
If the door is opened, the temperature of the refrigerator will warm up somewhat. That is normal.
The temperature will recover to a stable condition in a short time.
The refrigerator is designed to operate at a condition of 16 to 32 and humidity less than 85%RH (for HYC-260/360,the humidity should be less than 70%RH). Small amount of condensation
can occur on the surface of the unit if the actual condition is outside of this range. The storage
temperature of the unit, however, is not impacted. To reduce the condensation, please improve the
ventilation and drop the ambient temperature if possible.
The display on the panel shows the sensor temperature located in the refrigerator. It is not
necessary the same as the temperature in the center of the refrigerator. The cabinet temperature
will gradually reach an equilibrium state.
The battery in the refrigerator may be low after the refrigerator has been in storage for a long time.
Turn on the battery charge switch when the unit is powered up to allow the battery to be recharged.
The battery will be in full capacity after about a week’s charging.
Before loading the refrigerators, make sure the unit is at set temperature. Do not load in more than
1/3 of the storage volume to avoid thermally overloading the unit.
Only clean the unit with light soapy water. Never use brushes, acids, gasoline, soap powders,
polishing powders or hot water to clean refrigerators as these materials may damage the interior
painting and surface, parts and components. Never wide plastic parts with volatile solvents such
as gasoline.
If the unit is to be stored for a long period of time, turn off the power switch and the battery
charging switch.
Application guidelines
Do not dispose of electrical appliances as unsorted municipal waste, use separate collection
facilities.Contact you local government for information regarding the collection systems available.
If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into
the groundwater and get into the food chain, damaging your health and well-being.When replacing
old appliances with new ones, the retailer is legally obligated to take back your old appliance for
disposals at least free of charge.
Meaning of crossed –out wheeled dustbin:
Only professional people should perform maintenance work.
Loading...
+ 16 hidden pages