1. Press ìreset ìbutton.
2 . Press ìtest ìbutton, unit should trip.
3. Press ìresetî button again for use .
Do not use if above test fail.
In the event this device trips , the cause of the malfunction is to
be corrected before further use of the device .
Page 7
English
5
Page 8
English
You can run the fan only on not so hot days. The
fan can be set to run at 3 speeds (HIGH fan, MED
fan, LOW fan)as desired by you.
You have 3 levels of Fan Speed to set at your
desired comfort level. HIGH, MED and LOW.
24
6
Page 9
The Fresh Air Vent allows the air conditioner to
recirculate inside air, draw fresh air into the room
and exhaust stale air to the outside .
English
12. Electrostatic Filter (not all models)
Being constructed of high efficiency purifying
substance, active carbon fabric, electrostatic fabric,
electrostatic active carbon net and other materials
it purifies the air effectively. Its wavy structure
increases the capability to filter dust and smoke
effectively. Due to the retention of the active carbon
it has a high purifying speed capable of
strong airflow.
7
Page 10
English
Remote control and control panel operations
ON/OFF
MODE SPEED TIMER
TEMP/TIME
8
Page 11
Having set the temperature you will set the function of the air conditioner.
ON/OFF
MODE SPEED TIMER
English
TEMP/TIME
Every time you press the MODE button, it will change between FAN, COOL, ENERGY
SAVER and DEHUM. (See Fig. # 3)
9
Page 12
English
ON/OFF
MODE SPEED TIMER
TEMP/TIME
Once the function mode is decided you will have to set the fan speed.(See fig. #4)
Every time you press the SPEED button, fan speed will change between LOW,
HIGH,MED.
1) If you choose the COOL mode you can run the fan in one of the 3 speeds HIGH,
MED, LOW.
2) For cool days you may want to run the "FAN" function.
The fan can be set to run at
3 speeds (HIGH fan, MED fan, LOW fan)as desired by you.
3) If you choose to use the Dehumid function. This will remove excess moisture
from the air on excessively humid days.
Tr: temperature inside the room.
Ts: the set temperature.
1 ) When Tr>Ts+3 oF, the compressor will run continuously the fan at the
selected speed.
2)When Ts-1 oF*Tr*Ts+3 oF the compressor will cycle for 10 minutes on
and 6 minutes off.
3)When Tr<Ts-1 oF, the compressor will shut off.
The dehumidification process takes place between the set temperature -1
and 3 oF above the set temperature.
4)Energy Saver : The unit runs the same as COOL setting in the ENERGY SAVER
mode. But the fan will be off 3 minutes after the compressor cycle off.
10
Page 13
English
ON/OFF
MODE SPEED TIMER
TEMP/TIME
Timer on or Timer off mode is used to pre-start or shut off your unit in
advance. Y ou can program this up to 24 hours in advance. You can use
the Timer in 4 functions i.e. COOL, Energy saver , Dehumid or Fan .
Timer on (See Fig. # 5)
Unit must be on to set the timer. Unit will shut down automatically after it
accepts the settings in 5 seconds. Use this mode to pre-set the start time of
the unit 24 hours in advance.
a) Press TIMER ON, LED display will show "XX" (time set last time) when power
is connected first time, LED display will show "01".
b) Set desired number of hours by pressing the () pad of the T emp/Time
buttons, one for each hour. If you passed the desired time use the () pad
key to lower the selection.
c) After set TIMER ON, LED display will show the time. This time displayed:
unit will starts after X hours.
Timer off (See Fig. # 5)
Unit must be running to set the timer off. Use this to preset the time you
would like the unit to shut off.
a) Press TIMER OFF , LED display will show "XX" (time set last time) when power
is connected first time, LED display will show "01".
b) Set desired number by pressing the () pad of the T emp/Time buttons.
One for each hour. If you passed the desired time, use the () pad key to
lower the selection.
c) After set TIMER OFF, LED display will show the room temperature about 5 seconds later.
When using the timer the unit will use/revert to the last COOL and fan
settings when activated. The timer must be reset every time you choose to
use it.
11
Page 14
English
Fig. # 5
ON/OFF
MODE SPEED TIMER
TEMP/TIME
Vent Control Operations
For maximum cooling efficiency,
CLOSE the vent. This will allow
internal air circulation.
OPEN the vent to discharge stale air.
Adjusting the Air Flow Direction
Airflow can be adjusted by changing the direction of the air conditioner's louvers.
This can also increase the cooling efficiency of the air conditioner.
Adjusting Horizontal Air Flow
Direction
Adjusting the vertical louvers left and
right will change horizontal airflow.
Adjusting Vertical Air Flow Direction
Adjusting the Horizontal vane up and down will
change vertical airflow. The vane can be adjusted
by nudging the back or up and down of the vane.
Adjusting Horizontal Air Flow
Recommended orientation of louvers
Adjust louvers to face upwards when cooling to maximize cooling efficiency.
The air conditioner is designed to fit into double or single hung sash type windows. Each of the
units comes with an installation kit that provides adjustable mounting louvers, to fill the gaps
between the sides of the unit, and the window frame. The chart below reflects the dimensions of
the units with, and without installation kits. Measure your window opening width and compare
it to the chart below to ensure that it meets the minimum and maximum window width requirements.
B
C
A
HWR10XC5, HWR12XC5, HWR14XC5,ESA3105, ESA3125
D
English
Model
Dimension
A(inch)
B(inch)
C(inch)
D(inch) Max
D(inch) Min
Case High
Case Width
Case Depth