Top-Discharge Air Flow
Ultra Quiet Operation
Safty Power Cord
EnvicoCleanTMCoil
Easy-Access Washable Filter
Digital Display&Timer
Serial Number: Version:00.00
Edition: 2005-12-1
Domestic Air Conditioner Model: HWR10XC6
Content
1、 Product Code Illumination And Series introduction ---------------------------- 2
2、 Features -----------------------------------------------------------------------------------------3
3、 Specifications -------------------------------------------------------------------------------- 4
4、 Safety and Precaution -----------------------------------------------------------------------5
5、Warning and Cautions ----------------------------------------------------------------------6
6、Net Dimention ---------------------------------------------------------------------------------7
7、Installation and Accessory Parts -------------------------------------------------------8
8、Parts and Functions -----------------------------------------------------------------------10
9、Abnormity Diagnose -------- ---------------------------------------------------------------13
10、System Flow Chart -----------------------------------------------------------------------14
11、Circuit Diagram ----------------------------------------------------------------------------15
12、Maintenance Service and Trouble Shooting -----------------------------------16
13、Wiring Diagram --------------------------------------------------------------------------18
14、Exploded View and Parts Lists -----------------------------------------------------19
1
Domestic Air Conditioner Model: HWR10XC6
Product Code Illumination And Series Introduction
1.Model identification:
W
H
A B C D E F G
A: Abbreviation of Haier
B: Abbreviation of Window
C: R-Remote Control
F-Mechanical Control
D: Nominal cooling capacity(BTU/h) with the first two numbers based on one
thousand unit
E: The type of power supply
X: 115V/60HZ
V:208/220V/50HZ
F: Function code
C-Cooling only
H-Heating pump
E-Electric aided heating
G: Design code
E SA
A B C D
A: Abbreviation of Energy Star
B: No meaning
C: Nominal cooling capacity(BTU/h) with the first two numbers based on one
thousand unit
D: Design code
Examples:
HWR10XC6
It represents remote contrl window air conditioner.Cooling capacity is 10000BTU/h and
the power supply is 115V /60Hz.
2.Standard situation/conditions
No. Operating condition
1 Nominal cooling 26.7 19.4 35 23.9
2 Nominal heating / / / /
Nominal electrical
3
heating
Indoor air state outdoor air state
D.B.℃ W.B .℃ D.B.℃ W.B.℃
/ / / /
2
Domestic Air Conditioner Model: HWR10XC6
Specifications:
Item UNIT HWR10XC6
Cooling capacity BTU/h
Heating capacity BTU/h
Power supply
Power input
Cooling
Heating
Sound Level
Case
Packaging
dimensions
Weight
Compressor
Pressure
Refrigerant
Type
Fan
Fan
speed
Air volume CFM
Moisture removal Pints/hr
Exchanging pipe type/ diameter mm
Fin material
Running current
EER
Power input
Running current
COP
Indoor side dB(A)
Outdoor side dB(A)
Height
Width
Depth
Height
Width
Depth
Net lbs
Gross lbs
Type
Model
Running cap. for comp.
Starting method
Heating side
Cooling side
Model
Charge kg
indoor unit
outdoorunit
indoor unit r/min
outdoorunit r/min
BTU/(hW)9.8
BTU/(hW)/
W 1020
A 9.0
W /
A /
mm
mm
mm
mm
mm
mm
µF
Psig
Psig
60uf/250VAC
10000
/
1PH/115V/60Hz
56/54/52
/
347
500
450
445
570
494
64
68.5
Rotate
44R261AG-AJS
PSC
380
170
R22
0.49
Acentric fan
Axial fan
1300±30/1200±40/1100
±30
Evaporator:
condenser:ф7
Hydrophile aluminum foil
/
235
3.0
ф7
3
Domestic Air Conditioner Model: HWR10XC6
Safety and Precaution
4
Domestic Air ConditionerModel: HWR10XC6
Warning and Cautions
5
Net Dimention
Domestic Air ConditionerModel: HWR10XC6
347
500
450
6
Domestic Air Conditioner Model: HWR10XC6
Installation and Accessory Parts
7
Domestic Air Conditioner Model: HWR10XC6
Installation and Accessory Parts
ON/OFF
MODE SPEE D TIMER
TEMP/TIME
control
“ CR202 5“ batteryRe m o t e
Model: HWR10XC6
8
Domestic Air Conditioner Model: HWR10XC6
Installation and Accessory Parts
HWR08XC5, ESA3065,ESA3085
HWR10XC6
HWR08XC5, ESA3065, ESA3085
HWR10XC6
13
16
1
20
4
5
8
9
Domestic Air Conditioner Model: HWR10XC6
Installation and Accessory Parts
10
Domestic Air Conditioner Model: HWR10XC6
Installation and Accessory Parts
11
Domestic Air Conditioner Model: HWR10XC6
Parts and Functions
12
Domestic Air Conditioner Model: HWR10XC6
Abnormity Diagnose
1. Sensor diagnose: 2 seconds after the sensors open circuit or short
circuit, the unit will turn off automatically and the LED will show E0 until
the sensors resume.
2. Keystroke circuit error diagnose: When power on for the first time, the
PCB will check the keystroke circuit, if the sampling value is different with
the theory value, the LED will show E1, which means failed keystroke
circuit. The keyboard is locked and so invalid, but the remote control is
Always unplug your air conditioner be f ore cleaning.
The air filter behind the front gri ll e should be checked and cleaned
at least once every 2 w eeks or more often if necessar y.
To r e mo v e :
1. Open the inlet grille downward by pulling out the top of the inlet grille.
2. Remove the air filter from the front grille assembly by pulling the air
filter up slightly.
3. Clean the filter with warm, soapy water below 40
4. Rinse and gently shake the water from the filter and let it dry before
o
C(104oF).
replacing it.
DO NOT use your air conditioner without the ai r filter in plac e.
T o clean the front panels or the cabinet DO NOT use harsh
chemica ls, abrasives, ammonia, chlorin e, bleach, concentrated
detergents, solvents or metal scouring pads.
16
Some of these chemicals
Domestic Air Conditioner Model: HWR10XC6
Maintenance Service and Trouble Shooting
Trouble Shooting
If air conditioner does not operate:
●Check if unit is plugged in.The plug may have come loose.
●Check if the unit is in “off” mode.
●The fan control may be in “off” position.
Air from air conditioner is warm:
●The A/C setting may need to be raised.
●The temperature outside the room is below 65°F。The conpressor will not
cycle on if the temperature outside is below 65°F.
Ice formation on cooling coils:
●Outside temperature too cold .Set the unit on fan only setting to defrose ice.
●Lower temperature setting.Temperature setting may be too cold.
●Unit BTU may be too high for the room.
17
Wiring Diagram
WIRING DIAGRAM
R: RED
W: WHITE
B: BLACK
G: GREEN
GR: GRAY
BL: BLUE
OR: ORANGE
YL: YELLOW
Y/G: YELLOW/GREEN
Domestic Air ConditionerModel: HWR10XC6
0010556721
SIGNAL
RECEIVER
BOARD
POWER SUPPLY
IC1
CN20
SENSOR
B(NO RIBBED)
G
W(RIBBED)
UV
LIGHT
PROTECTOR
B
C
COMPRESSOR
M
S
R
R
W
HERM
C
CAPACITOR
FAN
B
CN2
TRANSFORMER
CN3
JK4-1
CN4
TR
CN5
MED
HI
W
OR
GR
R
6
3
5
GR
YL
OR
R
FUSE1
FUSE (250V 3.15A)
N
LOW
BL
2
1
4
BL
COM
NO
NOTE:THE COMPONENT PART IN BROKEN LINE AREA ISN'T
AVAILABLE FOR
THE UNIT WITHOUT UV-LIGHT FUNCTION.
FAN MOTOR
Y/G
M
BL
18
Domestic Air Conditioner Model: HWR10XC6
Sincere Forever
Haier Group
Haier Industrial Park, No.1, Haier Road
http://www.haier.com
266101, Qingdao, China
21
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.