Domestic Air Conditioner
SERVICE MANUAL
Models
HWR10XC6
Features
Top-Discharge Air Flow
Ultra Quiet Operation
Safty Power Cord
EnvicoCleanTMCoil
Easy-Access Washable Filter
Digital Display&Timer
Serial Number: Version:00.00
Edition: 2005-12-1
Domestic Air Conditioner Model: HWR10XC6
Content
1、 Product Code Illumination And Series introduction ---------------------------- 2
2、 Features -----------------------------------------------------------------------------------------3
3、 Specifications -------------------------------------------------------------------------------- 4
4、 Safety and Precaution -----------------------------------------------------------------------5
5、Warning and Cautions ----------------------------------------------------------------------6
6、Net Dimention ---------------------------------------------------------------------------------7
7、Installation and Accessory Parts -------------------------------------------------------8
8、Parts and Functions -----------------------------------------------------------------------10
9、Abnormity Diagnose -------- ---------------------------------------------------------------13
10、System Flow Chart -----------------------------------------------------------------------14
11、Circuit Diagram ----------------------------------------------------------------------------15
12、Maintenance Service and Trouble Shooting -----------------------------------16
13、Wiring Diagram --------------------------------------------------------------------------18
14、Exploded View and Parts Lists -----------------------------------------------------19
1
Domestic Air Conditioner Model: HWR10XC6
Product Code Illumination And Series Introduction
1.Model identification:
W
H
A B C D E F G
A: Abbreviation of Haier
B: Abbreviation of Window
C: R-Remote Control
F-Mechanical Control
D: Nominal cooling capacity(BTU/h) with the first two numbers based on one
thousand unit
E: The type of power supply
X: 115V/60HZ
V:208/220V/50HZ
F: Function code
C-Cooling only
H-Heating pump
E-Electric aided heating
G: Design code
E SA
A B C D
A: Abbreviation of Energy Star
B: No meaning
C: Nominal cooling capacity(BTU/h) with the first two numbers based on one
thousand unit
D: Design code
Examples:
HWR10XC6
It represents remote contrl window air conditioner.Cooling capacity is 10000BTU/h and
the power supply is 115V /60Hz.
2.Standard situation/conditions
No. Operating condition
1 Nominal cooling 26.7 19.4 35 23.9
2 Nominal heating / / / /
Nominal electrical
3
heating
Indoor air state outdoor air state
D.B.℃ W.B .℃ D.B.℃ W.B.℃
/ / / /
2
Domestic Air Conditioner Model: HWR10XC6
Specifications:
Item UNIT HWR10XC6
Cooling capacity BTU/h
Heating capacity BTU/h
Power supply
Power input
Cooling
Heating
Sound Level
Case
Packaging
dimensions
Weight
Compressor
Pressure
Refrigerant
Type
Fan
Fan
speed
Air volume CFM
Moisture removal Pints/hr
Exchanging pipe type/ diameter mm
Fin material
Running current
EER
Power input
Running current
COP
Indoor side dB(A)
Outdoor side dB(A)
Height
Width
Depth
Height
Width
Depth
Net lbs
Gross lbs
Type
Model
Running cap. for comp.
Starting method
Heating side
Cooling side
Model
Charge kg
indoor unit
outdoorunit
indoor unit r/min
outdoorunit r/min
BTU/(hW) 9.8
BTU/(hW) /
W 1020
A 9.0
W /
A /
mm
mm
mm
mm
mm
mm
µF
Psig
Psig
60uf/250VAC
10000
/
1PH/115V/60Hz
56/54/52
/
347
500
450
445
570
494
64
68.5
Rotate
44R261AG-AJS
PSC
380
170
R22
0.49
Acentric fan
Axial fan
1300±30/1200±40/1100
±30
Evaporator:
condenser:ф7
Hydrophile aluminum foil
/
235
3.0
ф7
3
Domestic Air Conditioner Model: HWR10XC6
Safety and Precaution
4
Domestic Air Conditioner Model: HWR10XC6
Warning and Cautions
5