Haier HW-18EMA13(T3), HW-24EMA13T3, HW-18EMA13, HW-24EMA13 Operation Manual

ROOM AIR CONDITIONER
0010534931
HW-18EMA13(T3) HW-24EMA13(T3)
Mode switch controls the fan motor speed,Cooling speed or Heating speed.
When set to “FAN”, fan motor runs to blow out air. When set to “HIGH COOL”, air-con will start cooling at high speed, blowing out strong air. When set to “MED COOL”, air-con will start cooling at med speed, blowing out less stronger air. When set to “LOW COOL”, air-con will start cooling at low speed, blowing out gentle air. When set to “HIGH HEAT”, air-con will start heating at high speed, blowing out strong air. When set to “LOW HEAT”, air-con will start heating at low speed, blowing out gentle air. When set to “OFF”, air conditioner stops running.
This function will work only under cooling status.
This function will work only under cooling status.
Note : Your model may differ from the one shown.
CLOSE:to the left side; OPEN:to the right side;
8
5 6
7 8
SELECTION OF THE INSTALLATION POSITION
THE ENCLOSED ACCESSORIES OF THE CONDITIONER
INSTALLATION PROCEDURES
PREPARATIONS BEFORE INSTALLATION
AIR CONDITIONER INSTALLATION
4
Fig.1
Wall
Water outlet flexible pipe(provide by user)
1. Fix the prefabricated iron frame to stable position by expansible screws.
2. Put the whole machine with all the accessories installed,
on the iron frame. If there's water outlet flexible pipe, lead it to needed position(see Fig.1).
3. Fill any distance between the wall hole and the machine body with flexible sponge rubber strip to prevent the entering of outer noise and the leaking of the coolness.
4. After installation of the conditioner, insert the power plug into the outlet and perform test-run.
Make the wall hole or window hole (see Fig.1)
Fig. 1
A
B
Width of the wall
Iron frame
MODEL A B
440mm
675mm
1,The air-conditioner is better installed in shadow or in a place with short period of sunshine. In case the air-conditioner is installed at the point exposed directly to the sunshine, it should be protected from the direct sunlight as possible in order to avoid the long time of direct sunlight otherwise its performance will be lowered. (As illustrated in Fig. 1).
2. For the convenience of operation, it is recommended that air-conditioner be installed at least at the height of 760-1300 mm above the floor and no obstacles before it for a free airflow.
3.The shutters at both sides and the top of air-conditioner should be protruded outdoors free from being blocked by wall, window,ect.
4.The back of air-conditioner should be kept over 500mm from the obstacles (for example, wall, etc.) (As illustrated in Fig. 2).
5.To have an efficient drainage, the back part of the air-conditioner should be inclined downward by 5-10mm (As illustrated in Fig. 3).
Install air-con at a place strong enough to support the unit. Leave enough space around air inlet and outlet for better circulation. Avoid places where flammable gas leaks. Problems may occur if unit is installed in the following places: Place where oil exists in the air including engine oil or seaside with salt breeze blows and hot spring area with sulphurous gas in the air.
For longer and trouble-free operation of the unit, pay special attention to the following:
NOTES:
Outlet pipe fitting
Sealed gasket
Manual
Rubber lid
Name
Figure
(ONLY FOR REFERANCE)
cover
support
fig.1
>500mm
fig.2
5-10mm
fig.3
Cautions
Power cord: Be sure to use the exclusive power cord.
Always use at the rated voltage and with specfic air conditioning circuit
Change installation place: If air-con need to be changed to another place please contact the dealer, who sold you the unit.
HW-18EMA13(T3)
HW-24EMA13(T3)
HW-18EMA13(T3)
TROUBLESHOOTING
5
1.Take out the conditioner and accessories from the package .
2.Choose one way from below two options
on disposal of the condensed water.
Prepare unit for installation:
Generally there are two methods available on disposal of the condensed water:
Block the bottom plate holeof the conditioner with rubber lid,install outlet pipe fitting on the back hole and let the condensing water flow from the back hole of the conditione
r. (See Fig.1 ) In this method, the accumulated condensed water in the bottom plate is hit by the fan onto the
heat exchan ger, and evapora ted an d blow n out from the machine. It c an coo l the heat exchanger adiator more quickl
y, and improve
the energy efficiency of the conditione
r. But the hitting noise by the fan at the outdoor side is relatively large.
Method 1
outlet pipe fitting
If necessary the above two methods can both have extra pipe added on the (available on the market).
Method 2
Block the back hole of the conditioner with
If the surrounding humidity is high:
rubber lid and install outlet pipe fitting
to the bottom hole, which can make the condensed water flow out from the bottom plate. (See Fig.2)
Fig.1
Bottom plate hole
Rubber lid
Outlet pipe fitting
Fig.2
Bottom plate hole
Rubber lid
Back hole
Back hole
Outlet pipe fitting
If problems can not be solved please pull out power plug and contact your dealer.
Before calling for service.
Check the following points before calling for repairs or service.
Is plug firmly inserted? Is there power failure?
Readjust power supply
Is thermostat switch wrongly adjusted?
Readjust the thermostat.
Is there any direct sunlight in the room?
Use curtain or blind.
Are doors or windows left open?
Shut doors and windows.
Are there any obstacles blocking air inlet and outlet?
Remove the obstacles.
Is there too much heat source in the room?
Is air filter clogged?
Clean it.
Remove the heat source
Does fuse get burned?
Phenomenon SolutionCause or check points
Replace fuse.
Switch on the machine but it does not work immediately.
If the machine is started after stop,it will need about 3 minutes to re-start so as to prevent the fuse from break.
Switch on the machine but it does not work.
The cooling effect is not good.
1 1 1 1
HW-24EMA13(T3)