Haier HW-24EMA13, HW-18EMA13 User Manual

HW-18EMA13(T3) HW-24EMA13(T3)
ROOM AIR CONDITIONER
0010534931
This function will work only under cooling status.
This function will work only under cooling status.
Mode switch controls the fan motor speed,Cooling speed or Heating speed.
When set to “FAN”, fan motor runs to blow out air. When set to “HIGH COOL”, air-con will start cooling at high speed, blowing out strong air. When set to “MED COOL”, air-con will start cooling at med speed, blowing out less stronger air. When set to “LOW COOL”, air-con will start cooling at low speed, blowing out gentle air. When set to “HIGH HEAT”, air-con will start heating at high speed, blowing out strong air. When set to “LOW HEAT”, air-con will start heating at low speed, blowing out gentle air. When set to “OFF”, air conditioner stops running.
Note : Your model may differ from the one shown.
CLOSE:to the left side; OPEN:to the right side;
8
4
AIR CONDITIONER INSTALLATION
(ONLY FOR REFERANCE)
INSTALLATION PROCEDURES
SELECTION OF THE INSTALLATION POSITION
1,The air-conditioner is better installed in shadow or in a place with short period of sunshine. In case the air-conditioner is installed at the point exposed directly to the sunshine, it should be protected from the direct sunlight as possible in order to avoid the long time of direct sunlight otherwise its performance will be lowered. (As illustrated in Fig. 1).
2. For the convenience of operation, it is recommended that air-conditioner be installed at least at the height of 760-1300 mm above the floor and no obstacles before it for a free airflow.
3.The shutters at both sides and the top of air-conditioner should be protruded outdoors free from being blocked by wall, window,ect.
4.The back of air-conditioner should be kept over 500mm from the obstacles (for example, wall, etc.) (As illustrated in Fig. 2).
5.To have an efficient drainage, the back part of the air-conditioner should be inclined downward by 5-10mm (As illustrated in Fig. 3).
>500mm
fig.2
NOTES:
For longer and trouble-free operation of the unit, pay special attention to the following:
Install air-con at a place strong enough to support the unit. Leave enough space around air inlet and outlet for better circulation. Avoid places where flammable gas leaks. Problems may occur if unit is installed in the following places: Place where oil exists in the air including engine oil or seaside with salt breeze blows and hot spring area with sulphurous gas in the air.
cover
support
5-10mm
fig.1
fig.3
1. Fix the prefabricated iron frame to stable position by expansible screws.
2. Put the whole machine with all the accessories installed,
on the iron frame. If there's water outlet flexible pipe, lead it to needed position(see Fig.1).
Wall
Water outlet flexible pipe(provide by user)
Fig.1
3. Fill any distance between the wall hole and the machine body with flexible sponge rubber strip to prevent the entering of outer noise and the leaking of the coolness.
4. After installation of the conditioner, insert the power plug into the outlet and perform test-run.
Cautions
Power cord: Be sure to use the exclusive power cord. Change installation place: If air-con need to be changed to another place please contact the dealer, who sold you the unit.
Always use at the rated voltage and with specfic air conditioning circuit
THE ENCLOSED ACCESSORIES OF THE CONDITIONER
Name
Figure
HW-18EMA13(T3)
HW-24EMA13(T3)
Rubber lid
Outlet pipe fitting
Manual
1 1 1 1
Sealed gasket
PREPARATIONS BEFORE INSTALLATION
Make the wall hole or window hole (see Fig.1)
MODEL A B
HW-18EMA13(T3) HW-24EMA13(T3)
440mm
A
675mm
B
Fig. 1
Iron frame
Width of the wall
5
TROUBLESHOOTING
Before calling for service.
5
7
6
8
Check the following points before calling for repairs or service.
Phenomenon SolutionCause or check points
Switch on the machine but it does not work immediately.
Switch on the machine but it does not work.
If the machine is started after stop,it will need about 3 minutes to re-start so as to prevent the fuse from break.
Is plug firmly inserted? Is there power failure?
Readjust power supply
Prepare unit for installation:
1.Take out the conditioner and accessories from the package .
2.Choose one way from below two options
Generally there are two methods available on disposal of the condensed water:
Method 1
Block the bottom plate hole of the conditioner
with rubber lid, install outlet pipe fitting on the back hole and let the condensing water flow from the back hole of the conditione this method, the accumulated condensed water in the bottom plate is hit by the fan onto the exchanger, and evaporated and blown out from t he machine. It c an cool the heat exchanger adiator more quickl the energy efficiency of the conditione hitting noise by the fan at the outdoor side is relatively large.
Method 2
If the surrounding humidity is high:
Block the back hole of the conditioner with rubber lid and install outlet pipe fitting bottom hole, which can make the condensed water flow out from the bottom plate. (See Fig.2)
If necessary the above two methods can both have extra pipe added on the (available on the market).
r. (See Fig.1 ) In
y, and improve
outlet pipe fitting
on disposal of the condensed water.
Outlet pipe fitting
heat
r. But the
Fig.1
to the
Fig.2
Rubber lid
Rubber lid
Outlet pipe fitting
Back hole
Bottom plate hole
Back hole
Bottom plate hole
Replace fuse.
Readjust the thermostat.
Use curtain or blind.
Shut doors and windows.
Remove the obstacles.
Clean it.
Remove the heat source
The cooling effect is not good.
Does fuse get burned?
Is thermostat switch wrongly adjusted?
Is there any direct sunlight in the room?
Are doors or windows left open?
Are there any obstacles blocking air inlet and outlet?
Is air filter clogged?
Is there too much heat source in the room?
If problems can not be solved please pull out power plug and contact your dealer.