HW-09CU03 HW-09CUA03
HW-12CU03 HW-12CUA03
HW-18CU03 HW-18CUA03
ROOM AIR CONDITIONER
OPERATION MANUAL
Control panel
CAUTION
When in use, put the signal transmission head
directly to the receiver hole on the indoor unit.
Don’t throw the controller, prevent it from being
damaged.
When electronic-started type fluorescent lamp or
change-over type fluorescent lamp or wireless
telephone is installed in the room, the receiver is
apt to be disturbed in receiving the signals so the
distance to the indoor unit should be shorter.
Please read this operation manual before using the air conditioner
Please keep it attentively
0010500010
CONTENTS
Safety precautions...................1
Air conditioner operation..........2
Care and Maintenance ............5
Air conditioner installation........6
Troubleshooting.......................8
1
SAFETY PRECAUTION
CAUTION
1. Do not install,remove and reinstall the unit yourself. Improper installation may cause leakage,electric
shock or fire.Please engage an authorized dealer or specialist for the installation work.
2. The room air conditioner must be earthed.
3. Do not touch or operate with wet hands.
4. Do not turn on the unit by inserting the power plug.Do not switch off the unit by pulling out the power
plug.
5. Do not insert sticks,fingers or other objects into the unit.
6. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar
qualified person.
7. After installation, the power plug should be easily reached.
8. The wiring method should be in line with the local wiring standard.
OPERATION CONDITIONS
Applicable ambient temperature range:
Cooling
Max.Temperture:
Min.Temperture:
2
AIR CONDITIONER OPERATION
D.B D.B
32 Co23 C
18 Co14 C
W.B
o
o
Indoor
o
43 C
o
18 C
Outdoor
26 C
W.B
o
/
D.B :Dry Bulb Temperature
W.B :Wet Bulb Temperature
HW-09CU03 HW-09CUA03
HW-12CU03 HW-12CUA03
AIR
H
TEMP/TIME
FAN
HI MED LO AUTO
SPEED
FUNCTION
A/C DEHUMID FAN
TIMER
START STOP SLEEP
SWEEP
ENERGY
º
C
SAVER
HW-18CU03 HW-18CUA03
1.ON/OFF
Press it to start unit and press it again to stop.
2.ENERGY SAVER
This will not only save you electrical and energy
costs but also shuts off the unnecessary noise
of the fan motor running.
3.TEMP. or TIME set
Used to set TIME or TEMP. setting.
4.FAN SPEED
Used to select desired fan speed.
5.TIMER
Used for TIMER start or stop.
6.SLEEP
Used to set SLEEP function.
7.FUNCTION
Used to select operation mode: A/C, DEHUMID,
FAN.
8.AIR SWEEP
Used to activate the vertical louver. This will
give you an even airflow throughout the room.
9.TEMP./TIME display
To protect unit system, don’t restart until
3 minutes have elapsed.
HINTS
Compressor won’t start in FAN mode ,only
fan motor will run at selected speed.
1
3
2
4
Remote controller
7
4
3
8
2
9
ON
OFF
1
6
5
A/C operation
1.Start
Press ON/OFF button.
2.Select operation mode
If you want to cool the room press the A/C button .
3.Select temp. setting
Select desires temp ,by using “+”or “-”button.
“+”Each press will increase temp.setting by 1℃.
“-”Each press will decrease temp. setting by 1℃.
4.Fan speed selection
If you choose the A/C mode you can run the fan in
one of the 4 speeds :HI or MED or LO or in the
AUTO speed.
5.Stop
Press ON/OFF button again.
FAN operation
1.Start Press ON/OFF button
2.Select operation mode
If you want to run the “Fan” function press the FAN
button .
3.Fan speed selection
Here the fan runs only at MED or LO speed.
4.Stop Press ON/OFF button again.
TIMER operation
PART INDENTIFICATION
Machine body
Front panel
Machine body
Air inlet
(outdoor side)
Air filter (inside)
Air inlet
(indoor side)
panel
Control
Air filter cleaning
2
Before cleaning, turn off
the power.
When dirt accumulates on air filter, air
circulation will be blocked, which causes
poor cooling. It is advisable to clean air
filter every two weeks for longer operation.
Take out the air filter
1.Loose the air inlet by pushing
“PUSH” at both edges as
shown.
2.Open the air inlet.
3.Remove the air filter.
Clean the filter
1.Gently flap the dirt off the air filter.
2.Carefully wash air filter in warm water(below 40°C).To
obtain better cleaning effect,soap water or neutral
detergent may be used.
3.Flush air filter carefully with clean water after removing
dirt.Let it dry completely.
Installation of filter
1.Replacing the air filter.
2.Push the air inlet marked with “PUSH” until you hear a
click.
Do not circumgyrate the
front panel any more than
90° to the unit or damage
to the tabs may occur.
Air filter(inside)
Air outlet
(indoor side)
CAUTION
PUSH
PUSH
Ventilation
1
(For model HW-18CU03
HW-18CUA03 only)
OPENCLOSE
The ventilation lever must be
CLOSE position in order to
maintain the best cooling
conditions. When fresh air is
necessary in the room, set the
ventilation lever to the OPEN
position. The damper is
opened and room air is
exhausted.
Airflow Direction
3
Airflow Direction Vane
The Vertical Airflow Direction
Vane is manually controlled
by positioning the vane to
discharge the air upward,
downward or straight out.
The horizontal air direction is
adjusted by setting the
AUTO SWING on.
DEHUMID operation
1.Start
Press ON/OFF button.
2.Select operation mode
If you need to only remove the moisture press
the Dehumid button .
3.Stop
Press ON/OFF button again.
Unit may run intermittently in Dehumid
mode with fan speed at “LO”, regardless
of its setting .
Air blown out will be very cold at relatively
low room temp.
SLEEP operation
1.Start unit and confirm its operation mode .
In Dehumid and fan mode , there is no sleep
function .
2.Select SLEEP function
Press the SLEEP button one time ,sleep can be
done ,Press the button for a second time ,the
setting is cancelled.Sleep lets you preset the unit
to shut off in 8 hours .
The setting of time is as below :
In sleep running ,the air velocity can be adjusted .
After the sleep finishes ,the air conditioner will
resume its former mode automatically .
In Sleep function ,temp.setting will rise
automatically by 1℃ after one hour’s
cooling operation .One hour later ,it will rise
by another 1℃ and maintain at this temp
.until the unit runs for approx. 6 hours.
With this function, unit will start or stop at the time
you want.
1.Start unit and select desired operation
mode.
2.Select Timer function
Timer start or Timer stop mode is used to
preset or shut off your unit in advance.
You can program this up to 12 hours in
advance. You can use the Timer in 3
functions i.e A/C, Dehumid, or Fan only.
Select desired mode. (TIMER start or TIMER
stop)
Timer Start
Unit must be on to set the timer. Unit will shut down
automatically after it accepts the setting in 5
seconds. Use this mode to preset the start time of
the unit 12 hours in advance.
a) Press Start, LED display will show “01”.
(Electrify for the first time)
b) Set desired number by pressing the (+) pad
of the Temp/Time buttons. One for each
hour. If you passed the desired time use the
(-) pad key to lower the selection.
Timer Stop
Unit must be running to set the timer off. Use this
to preset the time you would like the unit to shut
off.
a) Press Stop, LED display will show “01”.
(Electrify for the first time)
b) Set desired number by pressing the (+) pad
of the Temp/Time buttons. One for each
hour. If you passed the desired time, use the
(-) pad key to lower the selection.
“H” light is on the time is shown.
“℃” light is on the temperature is shown.
When using the timer the unit will use/revert to the
last A/C, fan settings when activated. The timer
must be reset every time you choose to use it.
HINTS
3 minutes delay function
After the conditioner is switched off, the protection device will make the compressor perform 3 minutes
delay before switching on the machine.
Power failure resume(please set and apply as necessary)
If sudden power failure occurs, the unit will resume original operation when power is supplied again.
Note:
When sudden power failure happens during unit operation in power failure resume mode, if the air
conditioner is not desired for use in a long period, please shut off the power supply in case that the unit
automatically resume operation when power is re-supplied, or press ON/OFF to turn off unit when power
resumes.
3
CARE AND MAINTENANCE
Always turn off the air conditioner and the main power supply before clean the unit.
Switch off the power supply if the unit is not going to be used for a long period of time.
Air filter cleaning
1
It is advisable to clean air filter every two weeks for
longer operation.
(You will find how to clean the filter on page 2 .)
Notes
2
Avoid opening doors and windows
unless necessary.
Use curtain or blind
Direct sunlight may reduce cooling
effect, always use window curtain.
Don't be exposed to cold air for
a long time.
Keep heat source away from
air conditioner.
Cleaning of the
air filter
Set temp . a little bit higher
before going to bed.
Proper
temperature
After unit stops, don't restart it
until 3 min. have elapsed.
OK! Enjoy a
3-min nap
PREPARATIONS BEFORE INSTALLATION
Make the wall hole or window hole (see Fig.1)
MODEL A B
HW-09CU03
HW-12CU03
HW-09CUA03
HW-12CUA03
HW-18CU03
HW-18CUA03
Prepare unit for installation:
1.Take out the conditioner and accessories from the package .
2.Disposal of the condensed water.
Block the bottom plate hole of the conditioner
with rubber lid, install drain elbow on the
back hole and let the condensing water flow from
the back hole of the conditioner. (See Fig.1 ) In
this method, the accumulated condensed water
in the bottom plate is hit by the fan onto the heat
exchanger, and evaporated and blown out
from the machine. It can cool the heat
exchanger adiator more quickly, and improve
the energy efficiency of the conditioner. But the
hitting noise by the fan at the outdoor side is
relatively large.
NOTE:
For some models your Drain elbow may be the
same as Fig.2.
355mm 535mm
420mm 580mm
A
Fig. 1
Fig.1
Fig.2
Iron frame
B
Width of the wall
Rubber lid
Drain elbow
Rubber lid
Don't hang clothes in the vicinity
of air inlet. This will decrease
cooling effect and cause abnormal
operation.
4
AIR CONDITIONER INSTALLATION
Temperature should be set properly
when there are infant,child, the
aged or disabled in the room.
Baby has
gone sleep,
better to adjust
suitable temp.
Before operating mode
selection switch, check that if
the air inlet or outlet have been
blocked.
(ONLY FOR REFERANCE)
SELECTION OF THE INSTALLATION POSITION
1,The air-conditioner is better installed in shadow or in a place
with short period of sunshine. In case the air-conditioner is
installed at the point exposed directly to the sunshine, it should
be protected from the direct sunlight as possible in order to
avoid the long time of direct sunlight otherwise its performance
will be lowered. (As illustrated in Fig. 1).
2. For the convenience of operation, it is
recommended that air-conditioner be installed at
least at the height of 760-1300 mm above the
floor and no obstacles before it for a free airflow.
3.The shutters at both sides and the top of
air-conditioner should be protruded outdoors free
from being blocked by wall, window,ect.
4.The back of air-conditioner should be kept over
500mm from the obstacles (for example, wall,
etc.) (As illustrated in Fig. 2).
5.To have an efficient drainage, the back part of
the air-conditioner should be inclined downward
>500mm
fig.2
by 5-10mm (As illustrated in Fig. 3).
NOTES:
For longer and trouble-free operation of the unit, pay special attention to the following:
Install air-con at a place strong enough to support the unit.
Leave enough space around air inlet and outlet for better circulation.
Avoid places where flammable gas leaks.
Problems may occur if unit is installed in the following places:
Place where oil exists in the air including engine oil or seaside with
salt breeze blows and hot spring area with sulphurous gas in the air.
cover
support
5-10mm
fig.1
fig.3
NOTE:
When install drain elbow, adjust the direction of the
drain elbow to make it be in line with the hole in
the rear of unit; Insert the drain elbow into hole
and twist 90°.
INSTALLATION PROCEDURES
1. Fix the prefabricated iron frame to stable position by expansible screws.
2. Put the whole machine with all the accessories installed on the iron frame.
If there's water outlet flexible pipe, lead it to needed position(see Fig.1).
3. Fill any distance between the wall hole and the machine body
with flexible sponge rubber strip to prevent the entering of outer
5
6
noise and the leaking of the coolness.
7
8
4. Open the Air inlet geille ,fix the front panel to the chassis
firmly with the accessorial screw.(see Fig.2 or Fig.3)
(NOTE:Your model will be the same as one of the right two
illustrations,not both.)
5. After installation of the conditioner, insert the power
plug into the outlet and perform test-run.
Cautions
Power cord: Be sure to use the exclusive power cord.
Change installation place: If air-con need to be changed to another
place please contact the dealer, who sold you the unit.
5
TROUBLESHOOTING
Before calling for service.
Check the following points before calling for repairs or service.
Phenomenon SolutionCause or check points
Switch on the machine but it
does not work immediately.
Switch on the machine but it
does not work.
The cooling effect is not good.
If the machine is started after stop,it will need about 3 minutes to
restart so as to prevent the fuse from break.
Is plug firmly inserted?
Is there power failure?
Does fuse get burned?
Is thermostat switch
wrongly adjusted?
Is there any direct
sunlight in the room?
Drain elbow
Fig.1
Fig.2 Fig.3
Readjust power supply
Replace fuse.
Readjust the thermostat.
Use curtain or blind.
Wall
Water outlet flexible
pipe(provide by user)
THE ENCLOSED ACCESSORIES OF THE CONDITIONER
Name
Figure
Quantity
Manual
Drain elbow
(with seal ring)
OR
1 1 1 1 1 1
Remote
controller
Battery Rubber lid Screw
Are doors or windows
left open?
Are there any obstacles
blocking air inlet and
outlet?
Is air filter clogged?
Is there too much heat
source in the room?
Shut doors and windows.
Remove the obstacles.
Clean it.
Remove the heat source
If problems can not be solved please pull out power plug and contact your dealer.NOTE:Your model will have one Drain elbow of the above two, not both.