Haier HW-18CI03 User Manual

WINDOW TYPE ROOM AIR CONDITIONER
OPERATION
MANUAL
HW-18CE03
HW-18CI13
Please read this operation manual before using the air conditioner.
No.0010545537
Contents
Contents Cautions Safety Instructions Preparation Part Names Operation Guide Maintenance Tips for Energy Saving For Trouble Free Operation Trouble shooting Important! Please Read Before Starting Installation Instructions Installation Guide
............................................................................. 2
............ .................................................................. 3
.............................................................. 4
......................................................................... 5
....................................................................... 6-7
............................................................. 8-9
..................................................................... 10
..................................................... 11
............................................. 11
............................................................... 12
..................................................... 14
............................................................... 15
.......................... 13
Cautions
Alert Symbols
The following symbols used in this manual alert you to potentially dangerous conditions to users, service personnel or the appliance:
WARNING
CAUTION
This symbol refers to a hazard or unsafe practice which can result in severe personal injury or death.
This symbol refers to a hazard or unsafe practice which can result in personal injury or product or property damage.
Installation Location
We recommend that this air conditioner be installed properly by qualified installation technicians in accordance with the Installation Instructions provided with the unit.
Before installation, check that the voltage of the electric supply
in
your home or office
nameplate.
WARNING
is the same as the voltage shown on the
Do not install this air conditioner where there are fumes or flammable gases, or in an extremely humid space such as a greenhouse.
Do not install this air conditioner where excessively high heat-generating sources are located.
Electrical Requirements
Safety Instructions
Read this Instruction Manual carefully before using this air conditioner. If you have any difficulties or questions, consult your dealer for help.
This air conditioner is designed to give you comfortable room conditions. Use this only for its intended purpose as described in this Instruction Manual.
The manufacturer does not accept responsibility for any damages that may arise due to non-observation of the following instructions.
Damaged air conditioners must not be operated. In case of doubt, consult your supplier.
WARNING
CAUTION
Never use or store gasoline or other flammable vapor or liquid near the air conditioner - it is very dangerous.
Do not turn the air conditioner on and off from the power mains switch. Use the ON/OFF operation switch.
Do not stick anything into the air outlet of the unit. This is dangerous because the fan is rotating at high speed.
Do not let children play with the air conditioner. Do not cool the room too much if babies or invalids are present.
Always remember to unplug the air conditioner before opening the inlet grille. Never unplug your air conditioner by pulling on the power cord. Always grip the plug firmly and pull straight out from the outlet.
All electrical repairs must be carried out by a qualified electrician. Inadequate repairs may result in a major source of danger for the user of the air conditioner.
Do not damage any parts of the air conditioner that carry refrigerant by piercing or perforating the air conditioner's tubes with sharp or pointed items, crushing or twisting any tubes, or scraping the coatings off the surfaces. If the refrigerant spurts out and gets into the eyes, it may result in serious eye injuries.
Do not obstruct or cover the ventilation grille of the air conditioner. Do not put fingers or any other objects into the inlet/outlet and swing louver.
Preparation
Disposal of your old air conditioner
Before disposing of an old air conditioner that goes out of use, please make sure it is inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment.
It must be noted that the air conditioner system contains refrigerant, which requires specialized waste disposal. The valuable materials contained in an air conditioner can be recycled. Contact your local waste disposal center for proper disposal of an old air conditioner and contact your local authority or your dealer if you have any questions. Please ensure that the tubing of your air conditioner does not get damaged prior to being picked up by the waste disposal center, and contribute to environmental awareness by insisting on an appropriate, antipollution method of disposal.
Disposal of the packaging of your new air conditioner
All the packaging materials employed in the packaging of your new air conditioner may be disposed without any danger to the environment.
The cardboard box may be broken up or cut into smaller pieces and given to a waste paper disposal service. The wrapping bag made of polyethylene and the polyethylene foam pad contain no fluorochloric hydrocarbon.
All these valuable materials may be taken to a waste collecting center and used again after adequate recycling.
Consult your local authorities for the name and address of the waste materials collecting center and waste paper disposal service nearest your home or office.
Parts Name
Machine body
Temp. setting
MODEL: HW-18CE03
VENTILATOR
Mode selection
Auto swing
WAIT 3 MINUTES BEFORE RESTARTING
Front panel Air inlet (indoor side)
Air outlet (indoor side) Air inlet (outdoor side)
Operation panel
Operation cover
Air filter
Operation panel
Ventilation lever
Temp. setting
Thermostat switch
Auto swing switch
VENTILATOR
Mode selection
Auto swing
WAIT 3 MINUTES BEFORE RESTARTING
Mode selection switch
Parts Name
Machine body
MODEL: HW-18CI13
Air inlet (outdoor side)
Front panel
Air outlet (indoor side)
Operation panel
Ventilation lever
Temp. setting
VENTILATOR
Auto swing
VENTILATOR
Mode selection
Temp. setting
Auto swing
WAIT 3 MINUTES BEFORE RESTARTING
Auto swing switch
Mode selection
Operation panel
Air inlet (indoor side)
Cabinet
Thermostat switch
WAIT 3 MINUTES BEFORE RESTARTING
Mode selection switch
Operation Guide
Auto air deflector switch
Auto swing
Mode selection switch
Mode selection
When the switch is set to " ", the indicator lights up, and vertical louvers will swing from side to side, delivering gentle air thus making you feel very comfortable. When it is set to " ", the indicator goes out, and the vertical louvers stop at any position.
Mode selection switch controls the fan motor speed and cooling speed.
<1>
When set to " ", fan motor runs at high speed to blow out strong air.
When set to " ", fan motor runs at low speed
<2>
to blow out gentle air.
<3>
When set to " ", air conditioner will start cooling at low speed, blowing out gentle air.
<4>
When set to " ", air conditioner will start speedy cooling, blowing out strong air.
Hint
<5>
When set to " ", air conditioner stops running.
When the mode selection switch is turned to " " or " " , the air conditioner will only blow out air without cooling.
If the mode selection switch is turned from cooling mode to fan mode, do not turn it back until at least 3 minutes have elapsed.
8
Operation Guide
Thermostat switch
Temp. setting
Vertical Airflow Direction Vane (Airflow direction adjustment Up-and-Down)
The Vertical Airflow Direction Vane is manually controlled by positioning the vane todischarge the air upward, downward or straight out.
This switch controls the preset indoor temperature to makethe air conditioner start or stop automatically, so as to reduce power consumption and operate the system both comfortably and economically.
Remarks:
The compressor stops running when the set temperature is reached but the fan continues to operate to keep an even indoor temperature.
Vertical airflow direction
Ventilation Lever
VENTILATOR VENTILATOR
" " position, the vent door opens to allow air, smoke or odors to be expelled from the
When the slide lever is at the:
" " position, the vent door is closed and the air inside the room is circulated and conditioned.
room.
CAUTION
In cooling mode, after you turn thermostat switch counter-clockwise, do not turn it back until at least 3 minutes have elapsed. Otherwise, the fuse may blow due to overload. Do not exceed the selection range.
9
Maintenance
Air filter cleaning: Please clean the air filter every two weeks
When dirt accumulates in the air filter, air circulation will be blocked, and causes poor cooling. It is advisable to clean the air filter every two weeks for efficient operation.
Removal of air filter
For HW-18CI13:
(1) Loosen the air inlet by pushing " PUSH " at both edges as shown. (2) Open the air inlet. (3) Hold the handle at lower part of the air filter and draw outward to remove the air filter.
For HW-18CE03:
(1) Loose the air filter by pushing " PUSH " at both ends of air inlet. (2) Hold the air filter by frame and lift it forward for approx. 5 mm. (3) Pull it out downward .
Air inlet
PUSH
Temp. setting
PUSH
PUSH
VENTILATOR
Mode selection
Temp. setting
Auto swing
WAIT 3 MINUTES BEFORE RESTARTING
PUSH
VENTILATOR
Mode selection
Auto swing
WAIT 3 MINUTES BEFORE RESTARTING
Air filter cleaning
1. Gently tap the dirt off the air filter.
2. Carefully wash the air filter in warm water (below 40 oC). To obtain better cleaning effect, soapy water or neutral detergent may be used.
3. Flush the air filter carefully with clean water after removing the dirt. Let it dry completely.
Installation of filter
For HW-18CI13:
(1) Put the air filter on. (2) Push the part marked " PUSH " until you hear a click.
For HW-18CE03:
(1) Hold the filter by its frame and push it upward along the groove under air inlet until it comes to a complete stop. (2) Push the part marked with " PUSH " until you hear a click.
Washing air filter
10
Tips For Energy Saving
Avoid opening doors and windows as much as possible.
Use curtain or blinds. Direct sunlight may reduce cooling effect, so always use window curtain.
No entrance
Do not hang clothes in the vicinity of the air inlet. This will decrease the cooling effect and cause abnormal operation.
Keep heat sources away from the air conditioner.
Keep away from me
Before operating the mode selection switch, check whether the air inlet or outlet has been blocked.
Go away!
For Trouble-Free Operation
For longer and trouble-free operation of the unit, pay special attention to the following:
Install the air conditioner at a location strong enough to support the unit. Leave enough space around the air inlet and outlet for better circulation. Avoid sites where flammable gas leaks. Problems may occur if the unit is installed in the following areas: Place where oil exists in the air including engine oil, seaside with salt breeze, and hot springs area with air-borne sulfurous gas.
11
Troubleshooting
Condition
Doesn't operate
No cool air or poor cooling
Check Item
Is plug firmly inserted? Is fuse burned out? Is there power failure?
Is thermostat switch incorrectly adjusted?
Is there direct sunlight into the room?
Is mode selection switch set to fan mode? Are doors or windows left open?
Corrective Action
Restore power or replace fuse.
Adjust the thermostat.
Use curtain or blinds.
Shut doors and windows.
Is there any obstacle blocking air inlet or outlet?
Is the fresh air knob shifted to the right? Is there a strong heat source in the room?
Is air filter clogged? Remove and clean.
If problems cannot be solved, please pull out power plug and contact your dealer.
12
Remove the obstacle.
Close vent by shifting knob to the left. Remove or turn off the heat source.
Important! Please Read Before Starting
This air conditioner meets strict safety and operating standards. As the installer or service person, it is an important part of your job to install or service the system so it operates safely and efficiently.
For safe installation and trouble-free operation, you must:
Carefully read the INSTRUCTION MANUAL and INSTALLATION INSTRUCTIONS attached to each air conditioner before starting.
Follow each installation or repair step exactly as shown.
Observe all local, state, and national electrical codes.
Pay close attention to all warning and caution notices given in this manual.
WARNING
This symbol refers to a hazard or unsafe practice which can result in severe personal injury or death.
CAUTION
This symbol refers to a hazard or unsafe practice which can result in personal injury or product or property damage.
If Necessary, Get Help
These instructions are all you need for most installation sites and maintenance conditions. If you require help for a special problem, contact our sales/service outlet or your certified dealer for additional instructions.
SPECIAL PRECAUTIONS
When Transporting
........................................................................
Be careful when picking up and moving the air conditioner. Get a partner to help, and bend your knees when lifting to reduce strain on your back. Sharp edges or thin aluminum fins on the air conditioner can cut your fingers.
When Servicing
........................................................................
Turn the power OFF at the main power box (mains) before opening the unit to check or repair electrical parts and wiring.
Keep your fingers and clothing away from any moving parts.
Clean up the site after you finish, remembering to check that no metal scraps or bits of wiring have been left inside the unit being serviced.
Others
........................................................................
CAUTION
Ventilate any enclosed areas when installing or testing the refrigeration system. Escaped refrigerant gas, on contact with fire or heat, can produce dangerously toxic gas.
When Wiring
............................................................................
ELECTRICAL SHOCK CAN CAUSE SEVERE PERSONAL INJURY OR DEATH. ONLY A QUALIFIED, EXPERIENCED ELECTRICIAN SHOULD ATTEMPT TO WIRE THIS SYSTEM.
All wiring must conform to local electrical codes. Each unit must be properly grounded with a ground (or earth) wire or through the supply wiring.
DO NOT, under any circumstances, cut or remove the third (ground) prong from the power cord plug.
DO NOT use an adapter plug or extension cord. DO NOT use a damaged power cord, plug, or wall
outlet. Replace them immediately.
DO NOT change the internal wiring or any part of the system.
DO NOT turn the air conditioner on and off by plugging and unplugging. Use the Operation switch.
Confirm upon completing installation that no refrigerant gas is leaking. If escaped gas comes in contact with a stove, gas water heater, electric room heater or other heat source, it can produce dangerously toxic gas.
13
Installation Instructions
Selection of the installation position
1. Select position where the structure is firm.
2. Select position where the air inlet and outlet are not blocked by obstacles.
3. Select position where the cooled air can be blown to every corner of the room.
4. Select position where there's no direct sunlight. If sunlight cannot be avoided, some means of sun shade is required.
5. Select position where the outdoor airflow will not bother neighbors.
6. Select position where condensation drainage is not impeded.
7. Select position where there's no dangerous gas or oil vapor nearby.
8. An extension cord is not recommended.
Installation diagram
The unit must be installed so that the back (outdoor side) is lower to allow drained water to flow out smoothly.
Width of wall should be less than 295mm
400mm
400mm
5 ~ 10mm
400mm
Requirements for electricity:
Be sure to use the specified voltage (25A max).
1. Applicable ambient temperature range is 21oC~52 oC.
2. If the power supply cord is damaged, it must be replaced by the manufacturer, the service, agent or a similar qualified supplier. An extension cord is not recommended.
3. The wiring method should comply with local wiring standards.
4. After installation, the power plug should be easy to access.
5. The breaker of the air conditioner should be an all-pole switch (25A) and the distance between its two contacts should be no less than 3mm.
6. The appliance must be connected to a socket outlet with the appropriate rating.
7.The appliance is not intended for use by young children or infirm persons without supervision.
8.Young children should be supervised to ensure that they do not play with the appliance.
Minimum distance
700mm
CAUTION
Power cord: Only to use an exclusive power cord. Changing installation site: If the air conditioner needs to be changed to another location, please contact the dealer that sold you the unit.
14
Installation Guide
Installation of air conditioner (only for reference)
1. Make a wooden frame. (Fig.1)
Model
BA
Metal support
A
HW-18CE03
HW-18CI13
670mm440mm
2. Attach a metal support (not provided by manufacturer) in a firm location with expanding screws or bolts.
3. Remove the air conditioner from its packing carton.
4. Place the air conditioner on the metal support.
5. Stuff gaps in the wall or window with soft sponge material or rubber gaskets to block outside noise and keep cool air from escaping.
Supplied accessory parts.
Name
Appearance
Manual1Side screw2Front screw
B
Thickness of wall
Fig.1
Quantity
1
Note: After finishing the installation of the air conditioner, fix the panel board onto the casing with two side attachment screws. (For HW-18CI13, add one front attachment screw)