Haier HW-18C03, HW-18C03/R1 Operation Manual

Page 1
OPERATION
MANUAL
WINDOW TYPE ROOM AIR CONDITIONER
No.0010546097
HW-18C03/R1
Please read this operation manual before using the air conditioner.
Page 2
2
Contents
Contents
............................................................................. 2
Part Names
.......................................................................... 3
Operation Guide
............................................................. 4-5
Maintenance
...................................................................... 6
Cautions
........................................................................... 7
Trouble shooting
............................................................... 8
Installation Instructions
..................................................... 9
Installation Guide
............................................................... 10
Page 3
Parts Name
Front panel
Air inlet (indoor side)
Air outlet (indoor side)
Air inlet (outdoor side)
Operation panel
Cabinet
3
Machine body
Operation panel
Mode selection switch
Auto swing switch
Thermostat switch
V entilation lever
WAIT 3 MINUTES BEFORE RESTARTING
VENTILATOR
Mode selection
Temp. setting
Auto swing
Page 4
4
Operation Guide
When the mode selection switch is turned to " " or " " , the air conditioner will only blow out air without cooling.
If the mode selection switch is turned from cooling mode to fan mode, do not turn it back until at least 3 minutes have elapsed.
<1>
<2>
<3>
<4>
<5>
When set to " ", fan motor runs at high speed to blow out strong air.
When set to " ", fan motor runs at low speed to blow out gentle air.
When set to " ", air conditioner will start cooling at low speed, blowing out gentle air.
When set to " ", air conditioner will start speedy cooling, blowing out strong air.
When set to " ", air conditioner stops running.
Mode selection switch controls the fan motor speed and cooling speed.
Hint
When the switch is set to " ", the indicator lights up, and vertical louvers will swing from side to side, delivering gentle air thus making you feel very comfortable. When it is set to " ", the indicator goes out, and the vertical louvers stop at any position.
Auto air deflector switch
Mode selection switch
Auto swing
Mode selection
Page 5
5
Operation Guide
In cooling mode, after you turn thermostat switch counter-clockwise, do not turn it back until at least 3 minutes have elapsed. Otherwise, the fuse may blow due to overload. Do not exceed the selection range.
This switch controls the preset indoor temperature to makethe air conditioner start or stop automatically, so as to reduce power consumption and operate the system both comfortably and economically.
The compressor stops running when the set temperature is reached but the fan continues to operate to keep an even indoor temperature.
Remarks:
Ventilation Lever
When the slide lever is at the:
" " position, the vent door opens to allow air, smoke or odors to be expelled from the room.
" " position, the vent door is closed and the air inside the room is circulated and conditioned.
Vertical airflow direction
Vertical Airflow Direction Vane (Airflow direction adjustment Up-and-Down)
The Vertical Airflow Direction Vane is manually controlled by positioning the vane todischarge the air upward, downward or straight out.
Thermostat switch
CAUTION
VENTILATOR VENTILATOR
Temp. setting
Page 6
Maintenance
6
Air filter cleaning: Please clean the air filter every two weeks
When dirt accumulates in the air filter, air circulation will be blocked, and causes poor cooling. It is advisable to clean the air filter every two weeks for efficient operation.
Removal of air filter
(1) Loosen the air inlet by pushing " PUSH " at both edges as shown. (2) Open the air inlet. (3) Hold the handle at lower part of the air filter and draw outward to remove the air filter.
1. Gently tap the dirt off the air filter.
2. Carefully wash the air filter in warm water (below 40 oC). To obtain better cleaning effect, soapy water or neutral detergent may be used.
3. Flush the air filter carefully with clean water after removing the dirt. Let it dry completely.
(1) Put the air filter on. (2) Push the part marked " PUSH " until you hear a click.
Air filter cleaning
Installation of filter
Power cord: Only to use an exclusive power cord. Changing installation site: If the air conditioner needs to be changed to another location, please contact the dealer that sold you the unit.
Washing air filter
PUSH
Air inlet
PUSH
CAUTION
WAIT 3 MINUTES BEFORE RESTARTING
VENTILATOR
Mode selection
Temp. setting
Auto swing
Page 7
Cautions
Avoid opening doors and windows as much as possible.
Use curtain or blinds. Direct sunlight may reduce cooling effect, so always use window curtain.
Keep heat sources away from the air conditioner.
Do not hang clothes in the vicinity of the air inlet. This will decrease the cooling effect and cause abnormal operation.
Before operating the mode selection switch, check whether the air inlet or outlet has been blocked.
Go away!
No entrance
Keep away from me
7
For longer and trouble-free operation of the unit, pay special attention to the following:
Install the air conditioner at a location strong enough to support the unit. Leave enough space around the air inlet and outlet for better circulation. Avoid sites where flammable gas leaks. Problems may occur if the unit is installed in the following areas: Place where oil exists in the air including engine oil, seaside with salt breeze, and hot springs area with air-borne sulfurous gas.
Page 8
8
Troubleshooting
Condition
Check Item
Corrective Action
Doesn't operate
Is plug firmly inserted? Is fuse burned out? Is there power failure?
Restore power or replace fuse.
No cool air or poor cooling
Is thermostat switch incorrectly adjusted?
Adjust the thermostat.
Is there direct sunlight into the room?
Use curtain or blinds.
Is mode selection switch set to fan mode? Are doors or windows left open?
Shut doors and windows.
Is there any obstacle blocking air inlet or outlet?
Remove the obstacle.
Is the fresh air knob shifted to the right? Is there a strong heat source in the room?
Is air filter clogged? Remove and clean.
If problems cannot be solved, please pull out power plug and contact your dealer.
Close vent by shifting knob to the left. Remove or turn off the heat source.
Page 9
9
Installation Instructions
Selection of the installation position
1. Select position where the structure is firm.
2. Select position where the air inlet and outlet are not blocked by obstacles.
3. Select position where the cooled air can be blown to every corner of the room.
4. Select position where there's no direct sunlight. If sunlight cannot be avoided, some means of sun shade is required.
5. Select position where the outdoor airflow will not bother neighbors.
6. Select position where condensation drainage is not impeded.
7. Select position where there's no dangerous gas or oil vapor nearby.
8. An extension cord is not recommended.
Installation diagram
The unit must be installed so that the back (outdoor side) is lower to allow drained water to flow out smoothly.
Requirements for electricity:
1. Applicable ambient temperature range :
2. If the power supply cord is damaged, it must be replaced by the manufacturer, the service, agent or a similar qualified supplier. An extension cord is not recommended.
3. The wiring method should comply with local wiring standards.
4. After installation, the power plug should be easy to access.
5. The breaker of the air conditioner should be an all-pole switch (25A) and the distance between its two contacts should be no less than 3mm.
6. The appliance must be connected to a socket outlet with the appropriate rating.
7.The appliance is not intended for use by young children or infirm persons without supervision.
8.Young children should be supervised to ensure that they do not play with the appliance.
Width of wall should be less than 295mm
5 ~ 10mm
400mm
400mm
400mm
700mm
Minimum distance
Cooling
Indoor Outdoor
Maximum: Minimum:
Maximum: Minimum:
D.B/W.B D.B/W.B
D.B
32oC/23oC 18oC/14oC
43oC/26oC
18oC
D.B/W.B
NOTE:For HW-18C03/R1 are CFC mode, which adopt the R407c refrigerant.
Page 10
10
Installation Guide
Installation of air conditioner (only for reference)
1. Make a wooden frame. (Fig.1)
2. Attach a metal support (not provided by manufacturer) in a firm location with expanding screws or bolts.
3. Remove the air conditioner from its packing carton.
4. Place the air conditioner on the metal support.
5. Stuff gaps in the wall or window with soft sponge material or rubber gaskets to block outside noise and keep cool air from escaping.
6. Lift the back of the machine body slightly.
You can see the drain hole at the back of the bottom plate. (see Fig. 2).
7. After installation of all the accessories,
put the whole machine on the metal support. If there's water outlet flexible pipe, lead the pipe to needed position (see Fig.3).
Supplied accessory parts.
Model
BA
Note: After finishing the installation of the air conditioner, fix the panel board onto the casing with one front attachment screw and two side attachment screws.
Name
Appearance
Quantity
Manual1Side screw2Front screw
1
Fig.2
Fig.3
Thickness of wall
Metal support
Fig.1
Wall
670mm440mm
HW-18C03/R1
Rubber lid
Condenser
A
B
water outlet flexible pipe
Loading...