POWER
MODE
SWING
1
2
3
4
5
6
7
8
ENERGY SAVER
FAN,COOL,DEHUM.
:HIGH or LOW.
FANSPEED
FANSPEED
Front panel
Air inlet (indoor side)
Air outlet (indoor side)
Air inlet (outdoor side)
Display
panel
Air filter (inside)
Machine body
Power plug

POWER
FAN SPEED
Press MODE button. For each press, operation mode
changes as follows: FAN COOL DEHUM
Press POWER button
2. Select operation mode
FANSPEED
When the COOL display light bright, A/C will
be working under the cooling function.
COOL
at outlet
E-S
FANSPEED

Air conditioner is running under displayed fan speed.
In DRY mode, when room temperature becomes
lower than temp.setting+2oC,unit will run intermittently
at LOW speed regardless of FAN setting.
COOL operation starts when room
temp.is higher than temp.setting.
On reaching temp.setting +2 C
unit will run in mild DRY mode.
Ultra-low air flow
Temp.setting+2 C
Temp.setting
POWER
POWER
Press MODE button. For each press, operation mode
changes as follows: FAN COOL DEHUM
2. Select operation mode
If you need to only remove the moisture
press the Dehnmid button.
Change air flow direction if necessary,
FAN SPEED
5
When the DEHUM display light bright,A/C will
be working under the dehumidify function.
FANSPEED
The compressor may cycle for 10 minutes on and 6 minuters off in
Dehumid mode.
E-S
FANSPEED
5
4

POWER
POWER
Press MODE button. For each press, operation mode
changes as follows: FAN COOL DEHUM
2. Select operation mode
When the FAN display light bright,A/C will
be working under the fan function.
FANSPEED
HI
E-S
4
4
FANSPEED

POWER
POWER
Press MODE button. For each press, operation mode
changes as follows: FAN COOL DEHUM
2. Select operation mode
Then select COOL operation
When the FAN display light bright,A/C will
be working under the fan function.
Saving energy function only can be used
when A/C working on cooling condition.
FANSPEED
When this feature is "On" , the fan will
shut off three minutes after the compressor
cycles off. This will reduce energy consumption
and noise. When the compressor turns back on,
the fan will turn on at the same time. In the "Off"
position, the fan will not shut off when the compressor
cycles off.
ENERGY SAVER operation
ENERGY SAVER
E-S
4
3
4
FANSPEED

FANSPEED
7
On Off
24
On Off
cool
On
24
Press "On"of remote controller or "TIMER" of control panel,
Off
Press "Off"of remote controller or "TIMER"of control panel,
E-S
FANSPEED

Power failure resume(please set and apply as necessary)
If sudden power failure occurs, the unit will resume original operation when power is supplied again.
Note:
When sudden power failure happens during unit operation in power failure resume mode, if the air
conditioner is not desired for use in a long period, please shut off the power supply in case that the
unit automatically resume operation when power is re-supplied, or press POWER to turn off the unit
when power resumes.
The horizontal air direction is adjusted
by setting the AUTO SWING ON .
Airflow Direction Vane
The Vertical Airflow Direction Vane is
manually controlled by positioning the
vane todischarge the air upward,
downward or straight out.
Note:
It is advisable not to keep vertical flap at downward position for a long time
in COOL or FAN mode, otherwise , condensate water might occur.
Don't move the horizontal flap with hand in order to avoid the vertical flap
abnormal, using the remote controller to adjust the move of vertical flap.
Vertical airflow direction
The compressor must stands by for 3 minutes before it is restareed after shut
down,There is no 3-minute protection with power on for the first time.

" CLOSE"position, the vent door opens to allow air, smoke
or odors to be expelled from the room;
" OPEN"position, the vent door is closed and the air inside
the room is circulated and conditioned.
CLOSE
OPEN

Disposal of the condensed water
Generally there are two methods available on disposal of the condensed water:
1. Block the bottom plate hole of the conditioner with rubber lid, install outlet pipe fitting on the
back hole and let the condensing water flow from the back hole of the conditioner. (See Fig.1 )
2. Block the back hole of the conditioner with rubber lid and install outlet pipe fitting to the bottom
hole, which can make the condensed water flow out from the bottom plate. (See Fig.2)
If necessary the above two methods can both have extra pipe added on the outlet pipe fitting.
(available on the market).
In this method, the accumulated condensed water in the bottom plate is hit by the fan onto the
heat exchanger, and evaporated and blown out from the machine. It can cool the heat exchanger
radiator more quickly, and improve the energy efficiency of the conditioner. But the hitting noise
by the fan at the outdoor side is relatively large.
Cautions
Power cord: Be sure to use the exclusive power cord.
Change installation place: If air-con need to be changed to another
place please contact the dealer, who sold you the unit.
(Refer to P12 for choosing these two modes.)
Bottom plate hole
Back hole
Outlet
pipe fitting
Fig.1
Rubber lid
Fig.2
Rubber lid
Back hole
outlet pipe fitting
Bottom plate hole