Haier HSU-12HEA03/R2 - annexe 1, HSUu001009HEA03/R2(DB)-I, HSUu001012HEA03/R2(DB)-I, HSUu001018HEA03/R2(DB)-I, HSUu001012HEA03/R2(DB)-A Operation Manual

Please read this operation manual before using the air conditioner.
0010523239
SPLIT TYPE ROOM AIR CONDITIONER
OPERATION MANUAL
Keep this operation manual for future reference.
Contents
2 3
6
8
7
PARTS AND FUNCTIONS OPERATION
MAINTENANCE
TROUBLE SHOOTING
HSU09HEA03/R2(DB)-I HSU12HEA03/R2(DB)-I HSU18HEA03/R2(DB)-I HSU12HEA03/R2(DB)-A
Outdoor
Unit
Singal receiver hole
COOL displayHEAT display
TEMP display
HEALTH display
Dry display
 
Loading of the battery
1
2
3
4
Parts and Functions
Indoor Unit
Actual inlet grille may vary from the one shown in the manual according to the product purchased
OUTLET
INLET
CONNECTING PIPING AND ELECTRICAL WIRING
DRAIN HOSE
(If the unit which you purchased
has healthy function,follow it.
TIMER OFF display
TIMER ON display SLEEP display
Remote controller
If not,please ignore.)
Remove the battery cover;
Load the batteries as illustrated.
2 R-03 batteries, resetting key
(cylinder);
Be sure that the loading
is in line with th
e" + "/"-";
Load the battery,then put on the cover again.
Clock set
Press CLOCK button, "AM" or "PM" flashes. Press or to set correct time. Each press
change quickly.
After time setting is confirmed,press SET,
"AM "and "PM" stop flashing,while clock starts working.
or decrease 1min. If the
button is kept pressed,time will
Inlet grille
Inlet
Air Purifying Filter
Outlet
Horizontal flap
Display board
(adjust up and do wn air flow
Don't adjust it manually)
(adjust left and right air flow)
Vertical blade
Emergency
Switch
Anion generator
(inside)
Display board
will increase
The distance between the signal transmission head and the rece­iver hole should be within 7m without any obstacle as well.
When electronic-started type fluorescent lamp or change-over
wireless telephone is installed in the
ver is apt to be disturbed in receiving
the signals,
so the distance to the indoor unit should be shorter.
type fluorescent lamp or room, the recei
Note:
Full display or unclear display during operation indicates the
ries have been used up.
Please change batteries.
If the remote controller can't run normally during operation, please
reload several minutes later.
batte
remove the batteries and
Remove the batteries in case unit won't be in usage for a long period.
If there are any display
after taking-out, just need to press reset key.
Hint:
POWER/SOFT
LOW HI
MED AUTO
If pressed, the other buttons
will be disabled. Press it once
again, lock will be cancelled.
30
.
LOCK
button
When the remote
RESET
button
controller appears abnormal, use a sharp
pointed article to press
this button to reset the
1
.
Control the lightening and
the indoor
extinguishing of
LED display board.
3.TIMER button
4. CLOCK button
5. SLEEP button
remote controller normal.
2.LIGHT button
6. MODE button
7. HOUR button
8. HEALTH button
9. ON/OFF button
10. TIMER ON display
11. FAN SPEED display
12. LOCK display
13. SWING UP/DOWN display
14. SLEEP display
15. HEALTH display
16. Operation mode display
Operation mode
AUTO
FAN
COOL DRY
Remote controller
Display board
HEAT
17
. Singalsending display
18. POWER/SOFT display
19. Left/right air flow display
20. TEMP display
21. TIMER OFF display
22. TIMER display
23. TEMP button
24. FAN button
25. HEALTH AIRFLOW button
26. SWING UP/DOWN button
27. SWING LEFT/RIGHT button
28. SET button
29. POWER/SOFT button
30
28
19
(1) The following functions and related displays are not available: (2) Cooling only unit do not have functions and displays related with heating.
2
3
Operation
Air Flow Direction Adjustm
AUTO COOL DRY FAN HEAT
2.Select operation mode
Press FAN button. For each press, fan speed changes as follows:
Press MODE button. For each press, operation mode changes as follows:
Remote controller:
Remote controller:
Select a desired temperature.
4.Fan speed selection
Air conditioner is running under displayed fan speed. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.
LOW
MED
HI
AUTO
1. Unit start
Press ON/OFF on the remote controller, unit starts.
Base Operation
Remote controller
Vertical flap
Pos.1
Pos.2
Pos.3
Pos.4
Pos.5
Pos.6
(Auto swing)
1.Status display of air sending
When restart after remote turning off, the remote
memorize the previous
Move the vertical blade by a knob on air
to adjust left and right direction referring to Fig.
2.Left and right air flow adjustment
(manual)
Cautions:
When adjusting the flap by hand,turn off the unit.
When humidity is high,condensate water might occur
adjusted to left or
It is advisable not to keep horizontal flap at downward position for a long time in COOLor DRY
otherwise, condensate water might occur.
conditioner
temperature is below 16
o
C, do not use it in the
Test operation:
Use this switch in the test operation when the room
normal operation.
your finger from the switch: the cooling
Continue to press the test operation switch for more than 5 seconds. After
you hear the "Pi" sound twice,
release
Test operation switch is the same as emergency switch.
operation starts with the air flow speed "Hi".
Emergency operation and test operation
Pi Pi
at air outlet if all vertical louvers are
right.
mode ,
controller will automatically
Note:
set swing position.
POWER/SOFT
Emergency Operation:
Pi
Use this operation only when the remote controller is defective or lost. When the emergency operation switch is pressed, the" Pi "sound is heard once, which means the start of this operation. In this operation, the system automatically selects the operation modes, cooling or fan or heat, according to the room temperature.
When machine is running in emergency, the set value of temperature and wind speed couldn't be altered; meanwhile, it can't operate for dehumidifying or under timing mode.
Press
button
Every time the button is pressed, temp.setting increase 1
o
C,if kept depressed, it will increase
rapidly
Every time the button is pressed, temp.setting
decrease 1
o
C,if kept depressed, it will decrease
rapidly
3.Select temp.setting
Operation
Mode
AUTO
Display Board
Remote
Controller
Note
COOL
DRY
HEAT
FAN
nothing
In DRY mode, when room temperature becomes lower than temp.setting+2
o
C,unit will run intermittently
at LOW speed regardless of FAN setting.
Under the mode of auto operation, air conditioner will automatically select Cool or Heat operation according to room temperature. air conditioner
automatically adjusts the fan speed
temperature.
When FAN is set to AUTO, the
according to room
In FAN operation mode, the unit will not operate in COOL or HEAT mode but only in FAN mode ,AUTO is not available in FAN mode.And temp.setting is disabled. In FAN mode,SLEEP operation is not available.