Haier HSU-24LEA13(T3), HSU-24LE03(T3) Installation Manual

No.0010518785
Installation Manual of Room Air Conditioner
Read this manual before installation
1.Driver
2.Hacksaw
3.Hole core drill
4.Spanner(17,19 and 26mm)
Torque wrench(17mm,22mm,26mm)
6.Pipe cutter
7.Fla
ring tool
8.Kni
fe
9.Nipper 12.Reamer
10.Gas leakage detector or soap-and-
water solution
11.Measuring tape
Explain sufficiently the operating means to the user according to this ma
nual.
A
B
C
D
E
F
G
Optional parts for piping
Ma
rk
Parts name
Non-adhesi
ve tape
Adhesi
ve tape
Saddle(L.S) with scr
ews
Connecting elect
ric cable
for indoor and outdoor
Drain hose
Heating insulating mate
rial
Piping hole c
over
Arrangement of piping directions
Rear left
Rear right
Left
Bel
ow
Right
No. Accessory parts
Remote controller
R-03 d
ry battery
Mounting plate
Drain hose
Steel nail, cement
Scr
ew
Plastic cap
Cover
Cushion
1
1
2
3
4
5
6
7
8
9
2
1
1
6
4
1
4
1
Number of articles
Accessory parts
4X50
4X25
Pipe supporting plate
Drawing for the installation of indoor and outdoor units
Necessary Tools for Installation
10
Drain-elbow
1
The marks from to in the figure are the parts numbers.
The distance bet
ween the indoor unit and the floor should be
more than 2m.
A
G
Attention must be paid to the
rising up of drain hose
m c 5
n a h
t e
r o
m
m
c
0
1
n
a
h
t
e
r
o
m
m
c
01
n
ah
t
e
r
o
m
A
C
m
c
0
1
n
a
h
t
e
r
o
m
m
c
06
n
a
h
t
e
r
o
m
m
c
5
1
n
a
h
t
e
r
o
m
m
c
0
1
n
a
h
t
e
r
o
m
D
E
Selection of pipe
To this unit, both liquid and gas pipes shall be insulated
as they become Iow temperature in operation.
Use optional parts for piping set or pipes covered with
equivalent insulation material.
2
HSU-24HEA03(T3) HSU-24LEA03(T3) HSU-24HEA13(T3) HSU-24LEA13(T3)
Floor fixing dimensions of the outdoor unit (Unit:mm)
113.5
633
113.5
6.433
Floor fixing dimensions of the outdoor unit (Unit:mm)
HSU-30HEA03(T3)
HSU-30HEA13(T3)
HSU-24LEA03-T
AMS30H03-N(T3)
PAS24L03-N(T3) HSU-32LEA13-W
HSU-24LEA13-M HSU-24LEA03
HSU-24LEB03(T3)
HSU-24HEA03
PAS30H03-N(T3)
HSU-36LEA03(T3) HSU-30LEA13(T3)
1.Fitting of the Mounting Plate and Positioning of the wall Hole
2.Making a Hole on the Wall and Fitting the Piping Hole Cover
When the mounting plate is first fixed
1.Carry out, based on the neighboring pillars or lintels, a proper leveling for the plate to be fixed against the wall, then temporarily fasten the plate with one steel nail.
2. Make sure once more the proper level of the plate, by hanging a thread with a weight from the central top of the plate, then fasten securely the plate with the attachment steel nail.
3. Find the wall hole location A using a measuring tape
Make a hole of 60 mm in diameter, slightly descending to outside the wall. Install piping hole cover and seal it off with putty after installation
(Section of wall hole)
Piping hole pipe
Outdoor side
Thickness of wall
Indoor side
Wall hole
60mm
G
Indoor unit
A=145mm
B= 60mm
mm03
Floor fixing dimensions of the outdoor unit (Unit:mm)
113.5
583
113.5
5.913
A=145mm
B= 60mm
mm03
HSU-24LEA13-M
HSU-24LEA03
HSU-24LEB03(T3)
HSU-24HEA03
HSU-18LEB03(T3)
15.88mm(5/8")
9.52mm(3/8")
Liquid pipe ( )
Gas pipe ( )
For
6.35mm(1/4")
12.7mm(1/2")
HSU-18LEB03(T3)
For 24K-36K
HSU-28LEA03(T3)
HSU-30LEA03(T3)
HSU-26HEA03
HSU-26HEA03
HSU-30HEA03
HSU-24LA2
HSU-24LA2
HSU-24LE03(T3)
HSU-24LE03(T3)
HSU-18LEB03(T3)
HSU-24LE03(T3)
Loading...