Haier HSU-24HEA03/R2-I - annexe 1 Installation Manual

HSU-24HEA03/R2-I
INSTALLATION MANUAL
ROOM AIR CONDITIONER WALL MOUNTED TYPE
NO.0010523237
Read this manual before installation
Explain sufficiently the operating means to the user
1.Driver
2.Hacksaw
3.Hole core drill
4.Spanner(17,19 and 26mm)
5.
Torque wrench(17mm,22mm,26mm)
6.Pipe cutter
7.Fla
ring tool
8.Kni
fe
9.Nipper 12.Reamer
10.Gas leakage detector or soap-and-
water solution
11.Measuring tape
A
B
C
D
E
F
G
Optional parts for piping
Ma
rk
Parts name
Non-adhesi
ve tape
Adhesi
ve tape
Saddle(L.S) with scr
ews
Connecting elect
ric cable
for indoor and outdoor
Drain hose
Heating insulating mate
rial
Piping hole c
over
Arrangement of piping directions
Rear left
Rear right
Left
Bel
ow
Right
No. Accessory parts
Remote controller
R-03 d
ry battery
Mounting plate
Drain hose
Steel nail, cement
Scr
ew
Plastic cap
Cushion
1
1
2
3
4
5
6
7
8
9
2
1
1
6
4
1
4
1
Number of articles
Accessory parts
4X50
4X25
Pipe supporting plate
Drawing for the installation of indoor and outdoor units
Necessary Tools for Installation
10
Drain-elbow
1
The marks from to in the figure are the parts numbers.
The distance between the indoor unit and the floor should be more than 2m.
A
G
Attention must be paid to the
rising up of drain hose
m c 5
na h
t e
r o m
m
c0
1n
a
h
t
e
r
o
m
m
c01
n
a
h
te
r
om
A
C
Guardring
10cmn
a
h
te
ro
m
10cm
n
a
h
t
e
r
o
m
60cm
n
a
h
te
r
om
15cm
n
a
h
t
e
ro
m
Fixing of outdoor unit
Indoor Unit
Selection of Installation Place
Power Source
Selection of pipe
Outdoor Unit
Fix the unit to concrete or block with bolts( 10mm) and nuts firmly and horizontally.
When fitting the unit to wall surface, roof or rooftop, fix a supporter surely with nails or wires in consideration of earthquake and strong wind.
If vibration may a
ffect the house, fix the unit by attaching a vibration-proof mat.
Place, robust not causing vibration, where the body can be supported su
fficiently.
Place, not a
ffected by heat or steam generated in the vicinity, where inlet and outlet of the unit are not disturbed. Place, possible to drain easil
y, where piping can be connected with the outdoor unit. Place, where cold air can be spread in a room entirel
y. Place, nearby a power receptacle, with enough space around. (Refer to drawings). Place where the distance of more than lm from televisions, radios, wireless apparatuses and fluorescent lamps can be left. In the case of fixing the remote controller on a wall, place where the indoor unit can receive signals when the fluorescent lamps in the room are lightened.
Place, which is less a
ffected by rain or direct sunlight and is
su
fficiently ventilated. Place, possible to bear the unit, where vibration and noise are not increased. Place, where discharged wind and noise do not cause a nuisance to the neighbors. Place, where a distance marked is available as illustrated in the above figure.
Before inserting power plug into receptacle, check the voltage without fail. The power source is the same as the corresponding name plate.
Install an exclusive branch circuit of the powe
r.
A receptacle shall be set up in a distance where the power cable can be reached. Do not extend the cable by cutting it.
To this unit, both liquid and gas pipes shall be insulated
as they become Iow temperature in operation.
Use optional parts for piping set or pipes covered with
equivalent insulation material.
2
Liquid pipe ( )
Gas pipe ( )
9.52mm(3/8")
15.88mm(5/8")
For 24K
184
580
184
8
0 3
Floor fixing dimensions of the outdoor unit (Unit:mm)
Indoor unit
1.Fitting of the Mounting Plate and Positioning of the wall Hole
2.Making a Hole on the Wall and Fitting the Piping Hole Cover
When the mounting plate is first fixed
When the mounting plate is fixed side bar and lintel
1.Carry out, based on the neighboring pillars or lintels, a proper leveling for the plate to be fixed against the wall, then temporarily fasten the plate with one steel nail.
2. Make sure once more the proper level of the plate, by hanging a thread with a weight from the central top of the plate, then fasten securely the plate with the attachment steel nail.
3. Find the wall hole location A using a measuring tape
Refer to the previous article, " When the mounting plate is first fixed ", for the position of wall hole.
Fix to side bar and lintel a mounting ba
r, Which is separately sold, and then fasten
the plate to the fixed mounting bar.
Make a hole of 83 mm in diameter, slightly descending to outside the wall. Install piping hole cover and seal it off with putty after installation
(Section of wall hole)
Piping hole pipe
Outdoor side
Thickness of wall
Indoor side
Wall hole
83mm
3.Installation of the Indoor Unit
Drawing of pipe
[ Rear piping ]
Draw pipes and the drain hose, then fasten them with the adhesive tape
[ Left Left-rear piping ]
In case of left side piping, cut away, with a nipper, the lid for left piping. In case of left-rear piping, bend the pipes according to the piping direction to the mark of hole for left-rear piping which is marked on heat insulation materials.
3
G
A=145mm
B= 83mm
mm03
Indoor unit
Fixing the indoor unit body
[Other direction piping]
Indoor/outdoor electric cable and drain hose must be bound with refrigerant piping by protecting tape.
Cut away, with a nipper, the lid for piping according to the piping direction and then bend the pipe according to the position of wall hole. When bending, be careful not to crash pipes. Connect beforehand the indoor/outdoor electric cable, and then pull out the connected to the heat insulation of connecting part specially.
Hang surely the unit body onto the upper notches of the mounting plate. Move the body from side to side to verify its secure fixing. In order to fix the body onto the mounting plate,hold up the body aslant from the underside and then put it down perpendicularly.
1. Insert the drain hose into the dent of heat insulation materials of indoor unit.
2. Insert the indoor/outdoor electric cable from backside of indoor unit, and pull it out on the front side, then connect them.
3. Coat the flaring seal face with refrigerant oil and connect pipes. Cover the connection part with heat insulation materials closely, and make sure fixing with adhesive tape
4
Heat insulation material
Drain hose
Piping
Indoor/outdoor electric cable
Lid for right piping
Lid for under piping
Lid for left piping
Fix with adhesive tape
Easily-demount cleaning of indoor unit
Inlet grille can be taken down
mounting plate
Open the inlet grille,press the button of unlock in the left,then push it out of the socket and take out the inlet grille.
Unloading of indoor unit body
When you unload the indoor unit,please use your hand to arise
the body to leave agraffe,then lift the bottom of the body outward
slightly and lift the unit aslant until it leaves the mounting plate.
mounting plate
agraffe