Explain sufficiently the operating means to the user
NO.0010523237
according to this manual.
Necessary Tools for Installation
1.Driver
2.Hacksaw
3.Hole core drill
4.Spanner(17,19 and 26mm)
Accessory parts
Number
4X50
ric cable
over
ews
rial
of
articles
No.Accessory parts
Remote controller
1
2
R-03 d
ry battery
3
Mounting plate
4
5
6
Scr
7
8
9
10
Optional parts for piping
Ma
rk
A
B
Saddle(L.S) with scr
C
Connecting elect
D
for indoor and outdoor
E
F
Heating insulating mate
G
Drain hose
Steel nail, cement
4X25
Plastic cap
ew
Guardring
Cushion
Pipe supporting plate
Drain-elbow
Parts name
Adhesi
ve tape
ve tape
Non-adhesi
Drain hose
Piping hole c
5.
6.Pipe cutter
7.Fla
8.Kni
1
2
1
1
6
4
1
Arrangement of piping directions
4
Left
1
1
Torque wrench(17mm,22mm,26mm)
9.Nipper12.Reamer
10.Gas leakage detector or
ring tool
fe
soap-and-
water solution
11.Measuring tape
Drawing for the installation of indoor and outdoor units
m
c
5
na
h
t
e
r
o
m
m
o
r
e
t
h
a
1n
c0
m
Attention must be paid to
the
rising up of drain hose
A
Rear left
Rear
right
Right
Bel
ow
10cm
n
a
h
t
e
r
o
m
m
ro
te
h
a
10cmn
60cm
n
a
h
te
r
om
om
r
te
h
a
n
c01
m
C
m
ro
e
t
h
a
n
15cm
G
The marks from to in the figure are the parts numbers.
A
The distance between the indoor unit and the floor should be
more than 2m.
0
8
3
184
580
184
Floor fixing dimensions
of the outdoor unit
(Unit:mm)
Fixing of outdoor unit
Indoor Unit
Place, robust not causing vibration, where the body can be supported
su
fficiently.
Place, not a
inlet and outlet of the unit are not disturbed.
Place, possible to drain easil
outdoor unit.
Place, where cold air can be spread in a room entirel
Place, nearby a power receptacle, with enough space around. (Refer
to drawings).
Place where the distance of more than lm from televisions, radios,
wireless apparatuses and fluorescent lamps can be left.
In the case of fixing the remote controller on a wall, place where the
indoor unit can receive signals when the fluorescent lamps in the room
are lightened.
ffected by heat or steam generated in the vicinity, where
y, where piping can be connected with the
Fix the unit to concrete or block with bolts( 10mm) and nuts firmly and horizontally.
When fitting the unit to wall surface, roof or rooftop, fix a supporter surely with nails
or wires in consideration of earthquake and strong wind.
If vibration may a
ffect the house, fix the unit by attaching a vibration-proof mat.
Selection of Installation Place
y.
Outdoor Unit
Place, which is less a
su
fficiently ventilated.
Place, possible to bear the unit, where vibration and noise are
not increased.
Place, where discharged wind and noise do not cause a
nuisance to the neighbors.
Place, where a distance marked is available as illustrated
in the above figure.
ffected by rain or direct sunlight and is
Power Source
Before inserting power plug into receptacle, check the voltage without fail. The power source is the same as the corresponding name plate.
Install an exclusive branch circuit of the powe
A receptacle shall be set up in a distance where the power cable can be reached. Do not extend the cable by cutting it.
r.
Selection of pipe
To this unit, both liquid and gas pipes shall be insulated
as they become Iow temperature in operation.
Use optional parts for piping set or pipes covered with
equivalent insulation material.
Liquid pipe ( )
Gas pipe ( )
2
For 24K
9.52mm(3/8")
15.88mm(5/8")
Indoor unit
1.Fitting of the Mounting Plate and Positioning of the wall Hole
When the mounting plate is first fixed
1.Carry out, based on the neighboring pillars or lintels, a proper leveling for the plate to be
fixed against the wall, then temporarily fasten the plate with one steel nail.
2. Make sure once more the proper level of the plate, by hanging a thread with a weight from
the central top of the plate, then fasten securely the plate with the attachment steel nail.
3. Find the wall hole location A using a measuring tape
B= 83mm
A=145mm
mm03
When the mounting plate is fixed side bar and lintel
Fix to side bar and lintel a mounting ba
the plate to the fixed mounting bar.
Refer to the previous article, " When the mounting plate is first fixed ", for the
position of wall hole.
r, Which is separately sold, and then fasten
2.Making a Hole on the Wall and Fitting the Piping Hole Cover
Make a hole of 83 mm in diameter,
slightly descending to outside the wall.
Install piping hole cover and seal it
off with putty after installation
Indoor side
Wall hole
83mm
(Section of wall hole)
G
Piping hole pipe
Outdoor side
Thickness
of wall
3.Installation of the Indoor Unit
Drawing of pipe
[ Rear piping ]
Draw pipes and the drain hose, then fasten them with the adhesive tape
[ LeftLeft-rear piping ]
In case of left side piping, cut away, with a nipper, the lid for left piping.
In case of left-rear piping, bend the pipes according to the piping direction to the mark of hole for left-rear
piping which is marked on heat insulation materials.
3
Indoor unit
1. Insert the drain hose into the dent of heat insulation materials of indoor unit.
2. Insert the indoor/outdoor electric cable from backside of indoor unit, and pull it out on the front side, then
connect them.
3. Coat the flaring seal face with refrigerant oil and connect pipes.
Cover the connection part with heat insulation materials closely, and make sure fixing with adhesive tape
Heat insulation
material
Lid for right piping
Lid for under piping
Fix with adhesive tape
Indoor/outdoor electric cable and drain hose must be bound with refrigerant piping by protecting tape.
Lid for left piping
Drain hose
Piping
Indoor/outdoor
electric cable
[Other direction piping]
Cut away, with a nipper, the lid for piping according to the piping direction and then bend the pipe according
to the position of wall hole. When bending, be careful not to crash pipes.
Connect beforehand the indoor/outdoor electric cable, and then pull out the connected to the heat insulation
of connecting part specially.
Fixing the indoor unit body
Hang surely the unit body onto the upper notches of the
mounting plate. Move the body from side to side to verify
its secure fixing.
In order to fix the body onto the mounting plate,hold up
the body aslant from the underside and then put it down
perpendicularly.
mounting plate
Unloading of indoor unit body
When you unload the indoor unit,please use your hand to arise
the body to leave agraffe,then lift the bottom of the body outward
slightly and lift the unit aslant until it leaves the mounting plate.
Easily-demount cleaning of indoor unit
Inlet grille can be taken down
Open the inlet grille,press the button of unlock in the left,then push
it out of the socket and take out the inlet grille.
4
mounting plate
agraffe
Loading...
+ 9 hidden pages