Haier HSU-24HEA13, HSU-24HEA03, HSU-24LEA13, HSU-24LEA03, HSU-30HEA03 User Manual

SPLIT TYPE ROOM AIR CONDITIONER
OPERATION MANUAL
HSU-24HEA03(T3) HSU-24LEA03(T3)
HSU-24HEA13(T3) HSU-24LEA13(T3)
HSU-30HEA13(T3) HSU-30HEA03(T3)
Please read this operation manual before using the air conditioner.
0010518784
Before disposing an old air conditioner that goes out of use, please make sure it's inop­erative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment.
It must be noticed that air conditioner system contains refrigerants, which require speciali­zed waste disposal. The valuable materials contained in an air conditioner can be recycled .Contact your local waste disposal center for proper disposal of an old air conditioner and contact your local authority or your dealer if you have any question. Please ensure that the pipework of your air conditioner does not get damagedprior to being picked up by the relevant waste disposal center, and contribute to environmental awareness by insisting on an appropriate, anti-pollution method of disposal.
Cautions
Disposal of the old air conditioner
All the packaging materials employed in the package of your new air conditioner may be disposed without any danger to the environment.
The cardboard box may be broken or cut into smaller pieces and given to a waste paper disposal service. The wrapping bag made of polyethylene and the polyethylene foam pads
contain no fluorochloric hydrocarbon.
All these valuable materials may be taken to a waste collecting center and used again after adequate recycling.
Consult your local authorities for the name and address of the waste materials collecting centers and waste paper disposal services nearest to your house.
Disposal of the packaging of your new air conditioner
Before starting the air conditioner, read the information given in the User's Guide caref­ully. The User's Guide contains very impor­tant observations relating to the assembly, operation and maintenance of the air conditioner.
The manufacturer does not accept respon­sibility for any damages that may arise due to non-observation of the following instruction.
Damaged air conditioners are not to be put into operation. In case of doubt, consult your supplier.
Use of the air conditioner is to be carried out in strict compliance with the relative instructions set forth in the User's Guide.
Installation shall be done by professional people, don't install unit by yourself.
For the purpose of the safety,the air con­ditioner must be properly grounded in acco­rdance with specifications.
Always remember to unplug the air conditioner before openning inlet grill. Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the outlet.
All electrical repairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditioner.
Safety Instructions and Warnings
Do not damage any parts of the air conditioner that carry refrigerant by piercing or performating the air conditioner's tubes with sharp or pointed items, crushing or twisting any tubes, or scraping the coatings off the surfaces. If the refrigerant spurts out and gets into eyes, it may result in serious eye injuries.
1
3. If the fuse of indoor unit on PC board is broken,please change it with the type of
T. 3.15A/ 250V.
Do not obstruct or cover the ventilation grille of the air conditoner.Do not put fingers or any other things into the inlet/outlet and swing louver.
Do not allow children to play with the air conditioner.In no case should children be allowed to sit on the outdoor unit.
The refrigerating circuit is leak-proof.
1.Applicable ambient temperature range:
Specifications
The machine is adaptive in following situation
10 .The power plug and connecting cable
must have acquired the local attestation.
2. If the power supply cord is damaged, it must be replaced by the manufacturer
or its service agent or a similar qualified person.
4. The wiring method should be in line with the local wiring standard.
5. After installation, the power plug should be easily reached.
6. The waste battery should be disposed properly.
7. The appliance is not intended for use by young children or infirm persons
without supervision.
8. Young children should be supervised to ensure that they do not play with the applience.
9.Please employ the proper power plug,
which fit into the power supply cord.
Cautions
11.In order to protect the units,please turn
off the A/C first, and at least 30 seconds later, cutting off the power.
2
For: 220-240V~, 50Hz
For: 220V~, 60Hz
Cooling
Indoor
Maximum:D.B/W.B
32
o
C/23oC
52
o
C/31oC
18
o
C
18
o
C/14oC
Maximum:D.B/W.B Minimum:D.B
Minimum:D.B/W.B
Outdoor
Indoor
Outdoor
Maximum:D.B Minimum:
D.B/W.B
Maximum:
D.B
Minimum:D.B
27
o
C
27
o
C/18oC
15
o
C
-7
o
C
Heating
Cooling
Heating
Indoor
Outdoor
Indoor
Outdoor
Maximum: D.B / W.B Minimum: D.B / W.B
Maximum: D.B / W.B Minimum: D.B
Maximum: D.B Minimum: D.B
Maximum: D.B / W.B Minimum: D.B / W.B
29oC/19oC 18
o
C/14oC
54oC/24oC 18oC
27oC 15oC
24oC/18oC
-7
o
C/-8oC
Cautions
STRICT ENFORCEMENT
Safety Instruction
Installation
WARNING
Please read the following Safety Instructions carefully prior to use.
The instructions are classified into two levels, WARNING and CAUTION according to the seriousness of possible risks and damages as follows. Compliance to the instructions are strictly required for safety use.
Please call Sales/Service Shop for the Installation.
Do not attempt to install the air conditioner by yourself because improper works may cause electric shock, fire, water leakage.
lnstallation in a inadequate place may cause accidents. Do not install in the following place.
Connect the earth cable.
earthing
Do not install in the place where there is any possibility of inflammable gas leakage around the unit.
Do not get the unit exposed to vapor or oil steam.
Check proper installation of the drainage securely
PROHIBITION PROHIBITION
CAUTION
3
Cautions
WARNING
When abnormality such as burnt-small found, immediately stop the operation button and contact sales shop.
OFF
Use an exclusive power source with a circuit breaker
ENFORCEMENT
Connect power supply cord to the outlet completely
Use the proper voltage
Do not use power supply cord in a bundle.
Take care not to damage
the power supply cord.
Do not use power supply cord
extended or connected in halfway
STRICT
ENFORCEMENT
STRICT
STRICT
ENFORCEMENT
PROHIBITION
PROHIBITION
PROHIBITION
PROHIBITION
Do not start or stop the operation by disconnecting the power supply cord and so on.
Do not channel the air flow directly at people, especially at infants or the aged.
Do not try to repair or reconstruct by yourself.
Do not use for the purpose of storage of food, art work, precise equipment, breeding, or cultivation.
CAUTION
Take fresh air occasionally especially when gas appliance is running at the same time.
PROHIBITION
STRICT
ENFORCEMENT
Do not operate the switch with wet hand.
PROHIBITION
PROHIBITION
PROHIBITION
PROHIBITION
PROHIBITION
Do not install the unit near a fireplace or other heating apparatus.
Check good condition of the installation stand
Do not pour water onto the unit for cleaning
PROHIBITION
Do not place animals or plants in the direct path of the air flow
Do not place any objects on or climb on the unit.
Do not place flower vase or water containers on the top of the unit.
Do not insert objects into the air inlet or outlet.
PROHIBITION
PROHIBITION
PROHIBITION
4
Parts and Functions
5
Indoor Unit
Outlet
Inlet
Inlet
grille
Anion gene
(inside)
Vertical blade(inside)
(adjust left and
Note:The inlet grill will not be risen automat grill upward.
rator
right air flow)
Outdoor Unit
Air filter(inside)
display board(inside)
Horizontal flap (adjust up and d Don't adjust it manually)
Power plug
ically,when the unit is placed with the inlet
own air flow
4
HSU-24HEA03(T3) HSU-24LEA03(T3) HSU-24HEA13(T3) HSU-24LEA13(T3)
OUTLET
INLET
CONNECTING PIPING AND ELECTRICAL WIRING
DRAIN HOSE
HSU-30HEA13(T3) HSU-30HEA03(T3)
4
Parts and Functions
Display board
19
POWER/SOFT
28
30
1.CODE
Used to select CODE A or B with a press,A or B will be displayed on LCD. Please select A without special explanation.
2.RESET
When the remote controller appears abnormal, use a sharp pointed article to press this button to reset the remote controller normal.
3.LIGHT button
Control the lightening and extinguishing of the indoor LED display board.
4. TIMER button
Used to select TIMER ON, TIMER OFF, TIMER ON-OFF.
5. CLOCK button
Used to set correct time.
6. HEALTH button
Used to set healthy operation.
7. MODE button
AUTO COOL DRY FAN HEAT
8. HOUR button
Used to set clock and timer setting.
9. SWING button
Used to select up or down air sending direction.
10. ON/OFF button
Used for unit start and stop.
31
11
. TIMER ON display
12
. FAN SPEED display
11
15
16
LOW HI
MED AUTO
23
21
13. LOCK display . SWING UP/DOWN display
14
. SLEEP display
15 16
. HEALTH display
17. Operation mode display
AUTO
Operation mode
Remote controller
Display board
COOL DRY
18.Singal sending display 19
. POWER/SOFT display . Left/right air flow display
20
21. TEMP display
Remote controller: to display the TEMP. setting.
. TIMER OFF display
22
. CLOCK display
23
. TEMP button
24
Used to select your desired temperature.
25. FAN button
Used to select fan speed: LOW,MED, HI, AUTO.
26. HEALTH AIRFLOW button
Used to set the health airflow mode.
27
. SLEEP button
Used to select sleep mode.
28. SET button
Used to confirm timer and clock settings.
29. POWER/SOFT button
Use to set power/soft function.
30. LOCK
Used to lock buttons and LCD display. If pressed, the other buttons will be disabled and the lock condition display appears. Press it once again, lock will be cancelled and lock condition display disappears.
31.
Remote signal receiver
HEAT
17
FAN
NOTE: The following functions and related displays are not available: 20
Cooling only unit do not have displays and functions related with heating
6
Parts and Functions
Clock Set
When unit is started for the first time and after replacing batteries in remote controller, clock should be adjusted as follows:
1. Press CLOCK button,"AM" or "PM" flashes.
2. Press or to set correct time. Each press will increase or decrease 1 min. If the button is kept depressed, time will change quickly.
3. After time setting is confirmed, press SET, "AM" or "PM" stop flashing, while clock starts working.
Remote controller's operation
When in use, put the signal transmission head directly to the receiver hole on the indoor unit. The distance between the signal transmission head and the receiver hole should be within 7m without any obstacle as well.
Don't throw or knock the remoter controller. When electronic-started type fluorescent lamp or change-over type fluorescent lamp or
wireless telephone is installed in the room, the receiver is apt to be disturbed in receiving the signals, so the distance to the indoor unit should be shorter.
Loading of the battery
Load the batteries as illustrated right 2 R-03 (7#) batteries
Remove the battery cover:
Slightly press" "area and push down the cover as illustrated.
Load the battery: Be sure that the loading is in line with the "+" / "-".
request as illustrated on the bottom of the case. Put on the cover again.
POWER/SOFT
Confirmation indicator: After pressing power ON/OFF, if no display, reload the batteries.
Note:
Full display or unclear display during operation indicates the batteries have been used up. Please change batteries.
Used two new same-typed batteries when loading. If the remote controller can't run normally during operation, please remove the batteries and
reload several minutes later.
Hints
After replacing with new batteries, remote controller will conduct self-check, displaying all information on LCD. Then, it will become normal.
Remove the batteries in case unit won't be in usage for a long period. If there are any display after taking-out, just need to press reset key.
7
Loading...
+ 17 hidden pages