Haier HSU-24H03/Z - annexe 1 User Manual

No.0010504735
HSU-24H03/Z
Maximum: D.B
10.The appliance must be installed on strong enough supporter.
9.Young children should be supervised ensure that they do not play with the appliance.
7. The waste battery should be disposed properly.
6. After installation, the power plug should be easily reached.
5. The wiring method should be in line with the local wiring standard.
4. The distance between the indoor unit and the floor should be more than 2m.
3. If the fuse on PC board is broken please change it with the type of T. 3.15A/250V.
11.The wiring diagram is attached inside the machine.
or a similar qualified person. The type of connecting wire is H05RN-F or H07RN-F
2. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent
Cautions
The machine is adaptive in following situation
I. Applicable ambient temperature range:
Cooling
Heating
Indoor
Outdoor
Outdoor
Indoor
Maximum: D.B / W.B 32oC/23oC
18oC/14oC 43oC/26oC
18oC 27oC
15oC 24oC/18oC
-7oC/-8oC
Minimum: D.B / W.B
Minimum: D.B Maximum: D.B
Minimum: D.B Maximum: D.B / W.B Minimum: D.B / W.B
1
Parts and Functions
Signal Receiving windows Running Indicator
Timer Mode Indicator Power Indicator
2
FAN
DRY HEAT
COOL
AUTO
Parts and Functions
Operation
1. Mode display
2. SWING display
3. FAN SPEED display
4. SLEEP display
5. LOCK display
6. SIGNAL SENDING
7. TIMER OFF display
8. TIMER ON display
9. CLOCK display
10. TEMP display
11. POWER ON/OFF
Used for unit start and stop.
12. MODE
Used to select AUTO run, COOL, DRY, HEAT and FAN operation
13. FAN
Used to select fan speed LO, MED, HI, AUTO
14. HOUR
Used to set clock and timer setting.
15. SWING
Used to set auto fan direction.
16. SLEEP
Used to select sleep mode.
17. LOCK
Used to lock buttons and LCD display.
18. TEMP.
Used to select your desired temp.
19. SET
Used to confirm timer and clock settings.
20. TIMER
Used to select TIMER ON, TIMER OFF, TIMER ON-OFF
21. CLOCK
Used to set correct time
22. RESET
normal condition.
Used to reset the controller back to
Clock set
When unit is started for the first time and after replacing batteries in remote controller, clock should be adjusted as follows: Press CLOCK button, "AM" or "PM" flashes. Press or to set correct time. Each press will increase or decrease 1min. If the button is kept depressed, time will change quickly. After time setting is confirmed, press SET, "AM "and "PM" stop flashing, while clock starts working.
Hints
After replacing with new batteries, remote controller will conduct self-check, displaying all information on LCD. Then, it will become normal.
NOTE: Cooling only unit do not have displays and functions related with heating
Buttons and display of the remote controller.
LO MED HIAUTO
ON/OFF
TEMP
MODE SET
FAN
TIMER
SWING
CLOCK
SLEEP
LOCK RESET
5 6
7
8
9
10
18 19
20
21
22
4
1
2 3
11
12
13 14
15
16
17
A U T O
ON OFF
AM PM
o
C
3
AUTO
LO
MED
HI
Parts and Functions
Operation
Buttons and display of the remote controller.
like the following figure:
If the unit which you purchased has healthy function, Remote controller should
BRIEF INTRODUCTION TO HEALTH OPERATION
The anion generator in the air conditioner can generate a lot of anion to effectively balance the quantity of position and anion in the air and also to kill bacteria and speed up the dust sediment in the room and finally clean the air in the room.
Hints
After replacing with new batteries, remote controller will conduct self-check, displaying all information on LCD. Then, it will become normal.
6. SIGNAL SENDING
7. TIMER OFF display
8. TIMER ON display
9. CLOCK display
10. TEMP display
11. POWER ON/OFF Used for unit start and stop.
12. MODE Used to select AUTO run, COOL, DRY, HEAT and FAN operation
13. FAN Used to select fan speed LO, MED, HI, AUTO
14. HOUR Used to set clock and timer setting.
15. SWING Used to set auto fan direction.
16. SLEEP Used to select sleep mode.
17. LOCK Used to lock buttons and LCD display.
18. TEMP. Used to select your desired temp.
19. SET Used to confirm timer and clock settings.
20. TIMER Used to select TIMER ON, TIMER OFF,
TIMER ON-OFF
21. CLOCK Used to set correct time
22. RESET
Used to reset the controller back to normal condition.
23. HEALTH
1. Mode display
AUTO
COOL
DRY
HEAT
FAN
2. SWING display
3. FAN SPEED display
4. SLEEP display
5. LOCK display
Used to set healthy operation
NOTE: Cooling only unit do not have displays and functions related with heating
HEALTH
ON/OFF TEMP
MODE SET
FAN TIMER
SWING CLOCK
SLEEP
LOCK RESET
4
1
2 3
11
12
13 14
15
16
17
5 6
7 8 9
10
19
21
22
18
20
A U T O
ON
OFF
AM PM
o
C
4
ÇëÑ¡ÓÃͬһƷÅÆÁ½½Ú 7# µç³Ø,³¤Ê±¼ä²»ÓÃʱ,Ϊ
·АЦ¹В©Т¹Зл½«µз³ШИ¡ ³ц¡£ ФЪК¹УГЦРИзУцТм³£,Зл ½«µз³ШИ¡³ц,6·ЦЦУºуФЩ Ч°ИлРВµз³Ш¡£
º£¶ы¼¯НЕЗаµºº£¶ы ¿ХµчЖчУРПЮЧЬ¹«Л¾
ÇëÑ¡ÓÃͬһƷÅÆÁ½½Ú 7# µç³Ø,³¤Ê±¼ä²»ÓÃʱ,Ϊ
·АЦ¹В©Т¹Зл½«µз³ШИ¡ ³ц¡£ ФЪК¹УГЦРИзУцТм³£,Зл ½«µз³ШИ¡³ц,6·ЦЦУºуФЩ Ч°ИлРВµз³Ш¡£
º£¶ы¼¯НЕЗаµºº£¶ы ¿ХµчЖчУРПЮЧЬ¹«Л¾
ÇëÑ¡ÓÃͬһƷÅÆÁ½½Ú 7#
µç³Ø,³¤Ê±¼ä²»ÓÃʱ,Ϊ
·АЦ¹В©Т¹Зл½«µз³ШИ¡ ³ц¡£ ФЪК¹УГЦРИзУцТм³£,Зл ½«µз³ШИ¡³ц,6·ЦЦУºуФЩ
×°Èëеç³Ø¡£
º£¶ы¼¯НЕЗаµºº£¶ы ¿ХµчЖчУРПЮЧЬ¹«Л¾
Operation
Remote controller's operation
When in use, put the signal transmission head directly to the receiver hole on the indoor unit.
The distance between the signal transmission head and the receiver hole should be within 7m without any obstacle as well.
Don't throw the controller, prevent it from being damaged. When electronic-started type fluorescent lamp or change-over
type fluorescent lamp or wireless telephone is installed in the room, the receiver is apt to be disturbed in receivering the signals so the distance to the indoor unit should be shorter.
Loading of the battery
Load the batteries as illustrated. 2 R-03 batteries, resetting key (cylinder)
Remove the battery cover:
Slightly press " " and push down the cover.
Load the battery:
Be sure that the loading is in line with the" + "/"-" pole request as illustrated.
Put on the cover again Confirmation indicator:
In disorderation, reload the batteries or load the new batteries after 6mins.
Note:
Use two new same-typed batteries when loading. If the remote controller can't run normally or doesn't work at all, use a sharp pointed item to press the reset key.
Hint:
Remove the batteries in case unit won't be in usage for a long period. If there are any display after taking-out just need to press reset key.
Power failure resume(please set and apply as necessary)
If sudden power failure occurs, the unit will resume original operation when power is supplied again.
Note:
When sudden power failure happens during unit operation in power failure resume mode, if the air conditioner is not desired for use in a long period, please shut off the power supply in case that the unit automatically resume operation when power is re-supplied, or press ON/OFF to turn off the unit when power resumes.
5
(4) Unit stop
(1) Unit start
Auto run, Fan operation
Enjoy yourself by just a gentle press.
Operation
mode changes as follows:
Press ON/OFF button, unit starts. Previous operation status appears on display. (Not Timer setting) Power indicator on indoor unit lights up.
(2) Select operation mode
Press MODE button. For each press, operation
AUTO COOL DRY HEAT FAN
Unit will run in selected mode. Stop display at " " AUTO or " "FAN.
(3) FAN
Press FAN button. For each press, fan speed changes as follows:
AUTO LO MED HI
Unit will run at selected fan speed. Note:AUTO is not available in FAN mode.
Press ON/OFF button. Only time remains on LCD. All indicators on indoor unit go out. Vertical flap closed automatically.
Hints
Remote controller can memorize settings in each operation mode. To run it next time just select the operation mode and it will start with the previous setting. No reelecting is needed.(TIMER ON/OFF needs reelecting)
Cautions: Note: On cooling only unit, heating mode is not available, The above information is the
After replacing batteries, press ON/OFF, and display explanation of the displayed becomes as follows: information therefore varies Operation mode: AUTO, Temp. No with those displayed in actual Timer mode: No, Fan speed :AUTO operation.
ON/OFF TEMP
SET
TIMER
CLOCKSWING
SLEEP
LOCK
RESET
FAN
MODE
1
2
3
4
6
Press MODE button. For each press, operation
Recommendations:
Operation
COOL,HEAT and DRY operation
Use COOL in summer. Use HEAT in winter Use DRY in spring, autumn and in damp climate.
(1) Unit start
mode changes as follows:
Press ON/OFF button, unit starts. Previous operation status appears on display.(Not Timer setting) Power indicator on indoor unit lights up.
(2) Select operation mode
AUTO COOL DRY HEAT FAN
Unit will run in operation mode displayed on LCD. Stop display at your desired mode.
(3) Select temp. setting
Press TEMR button.
Every time the button is pressed, temp. setting increases 1oC Every time the button is pressed, temp. setting decreases 1oC
Unit will start running to reach the temp. setting on LCD.
Press FAN button. For each press, fan speed changes
(4) Fan speed selection
as follows:
AUTO LO MED HI
just press ON/OFF button and unit will run in previous status.
Unit runs at the speed displayed on LCD. In DRY mode, when room temp. becomes 2oC higher than temp. setting, unit will run intermittently at LO speed regardless of FAN setting.
Hints
On cooling only unit, heating mode is not available. Remote controller can memorize each operation status. When starting it next time,
COOL operation starts when room temp. is higher than temp. setting.
Ultra-low air flow
Temp. setting+2oC
Temp. setting
On reaching temp. setting, unit will run in mild DRY mode.
ON/OFF TEMP
SET
TIMER
CLOCKSWING
SLEEP
LOCK
RESET
FAN
MODE
1
2
3
4
3
5
6
7
Operation
(5) Air flow direction adjustment
After operation mode is selected, vertical flap will open automatically according to the mode. Referring to the Fig.
COOL
HEAT
COOL
HEAT
About 10
o
About 10
o
better set a temp. difference of 3-5oC between indoor and outdoor temp. in COOL mode.
Hints
As cold air flows downward in COOL mode, adjusting air flow horizontally will be much more helpful for a better air circulation. As warm air flows upward in HEAT mode, adjusting air flow downward will be much more helpful for a better air circulation. Be careful not to catch a cold when cold air blows downward. It is harmful to your health in summer to go frequently in and out of places where temp. difference is above 7oC. Temp. difference of 3-5oC will remove your fatigue. More than this, unit's load can be reduced and power consumption cut down as well. So, you'd
(6) Unit stop
Press ON/OFF button. Only time remains on LCD. Vertical flap closes automatically.
Cautions:
Unit won't restart until 3 minutes have elapsed, due to system protection. HEAT mode is not available on cooling only unit.
It is advisable not to keep vertical flap at downward position for a long time in COOL or DRY mode, otherwise, condensate water might occur.
Cautions:
Cautions:
When humidity is high, condensate water might occur at air outlet if all horizontal louvers are adjusted to left or right.
Move the horizontal blade by a knob on air conditioner to adjust left and right direction referring to Fig.
Left and right air flow adjustment (manual)
Press SWING button, vertical flap will move within the range shown in the Fig. Press SWING button stop it at a fixed position.
Up and down (Use remote controller)
About 45
o
About 60
o
About 60
o
8
Operation
TIMER Operation
You can let unit start or stop automatically at following times: Before you wake up in the morning, or get back from outside or after you fall asleep at night.
Set Clock correctly before starting Timer operation
TIMER ON/OFF
Power indicator on indoor unit lights up.
(1)After unit start, select your desired operation mode. Operation mode will be displayed on LCD.
(2)TIMER mode selection
Press TIMER button to change TIMER mode. Every time the button is pressed, display changes as follows:
ON OFF ON OFF
TIMER ON TIMER OFF TIMER ON-OFF
blank
Select your desired TIMER mode (TIMER ON or TIMER OFF) ON or OFF will flash.
(3)Timer setting
Press HOUR / button.
Every time the button is pressed, time increases 10 min.
If button is kept depressed, time will change quickly.
Every time the button is pressed, time decreases 10 min. If button is kept depressed, time will change quickly. Time will be shown on LCD. It can be adjusted within 24 hours.
Timer mode indicator on indoor unit lights up.
(4)Confirming your setting
After setting correct time, press SET button to confirm, "ON" or "OFF" stops flashing Time displayed: Unit starts or stops at x hour x min. (TIMER ON or TIMER OFF).
To cancel TIMER mode
Just press TIMER button several times until TIMER mode disappears.
Hints
After replacing batteries or a power failure happens, Time setting should be reset.
Remote controller possesses memory function, when use TIMER mode next time, just
press SET button after mode selecting if timer setting is the same as previous one.
ON/OFF TEMP
SET
TIMER
CLOCKSWING
SLEEP
LOCK
RESET
FAN
MODE
ON
1
2
3
4
3
9
Loading...
+ 22 hidden pages