Haier HSU-22H03/R2 User Manual

SPLIT TYPE ROOM AIR CONDITIONER
OPERATION MANUAL
HSU-18H03/R2(DB) HSU-22H03/R2(DB)
Please read this operation manual before using the air conditioner.
No.
Cautions
Disposal of the old air conditioner
Before disposing an old air conditioner that goes out of use, please make sure it's inop­erative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment.
It must be noticed that air conditioner system contains refrigerants, which require speciali­zed waste disposal. The valuable materials contained in an air conditioner can be recycled .Contact your local waste disposal center for proper disposal of an old air conditioner and contact your local authority or your dealer if you have any question. Please ensure that the pipework of your air conditioner does not get damagedprior to being picked up by the relevant waste disposal center, and contribute to environmental awareness by insisting on an appropriate, anti-pollution method of disposal.
Safety Instructions and Warnings
Before starting the air conditioner, read the information given in the User's Guide caref­ully. The User's Guide contains very impor­tant observations relating to the assembly, operation and maintenance of the air conditioner.
The manufacturer does not accept respon­sibility for any damages that may arise due to non-observation of the following instruction.
Damaged air conditioners are not to be put into operation. In case of doubt, consult your supplier.
Use of the air conditioner is to be carried out in strict compliance with the relative instructions set forth in the User's Guide.
Installation shall be done by professional people, don't install unit by yourself.
Disposal of the packaging of your new air conditioner
All the packaging materials employed in the package of your new air conditioner may be disposed without any danger to the environment.
The cardboard box may be broken or cut into smaller pieces and given to a waste paper disposal service. The wrapping bag made of polyethylene and the polyethylene foam pads
All these valuable materials may be taken to a waste collecting center and used again after adequate recycling.
Consult your local authorities for the name and address of the waste materials collecting centers and waste paper disposal services nearest to your house.
For the purpose of the safety,the air con­ditioner must be properly grounded in acco­rdance with specifications.
Always remember to unplug the air conditioner before openning inlet grill. Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the outlet.
All electrical repairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditioner.
Do not damage any parts of the air conditioner that carry refrigerant by piercing or performating the air conditioner's tubes with sharp or pointed items, crushing or twisting any tubes, or scraping the coatings off the surfaces. If the refrigerant spurts out and gets into eyes, it may result in serious eye injuries.
1
Cautions
Do not obstruct or cover the ventilation grille of the air conditoner.Do not put fingers or any other things into the inlet/outlet and swing louver.
Do not allow children to play with the air conditioner.In no case should children be allowed to sit on the outdoor unit.
Specifications
The refrigerating circuit is leak-proof.
The machine is adaptive in following situation
1.Applicable ambient temperature range:
Cooling
Heating
Indoor
Outdoor
Indoor
Outdoor
Maximum:D.B/W.B Minimum:D.B/W.B
Maximum:D.B/W.B Maximum:D.B
Maximum:D.B Maximum:D.B
Maximum:D.B/W.B Minimum:D.B/W.B
32oC/23oC 18oC/14oC
43oC/26oC 18oC
27oC 15oC
24oC/18oC
-7oC/-8oC
7. The appliance is not intended for use by young children or infirm persons without supervision.
8. Young children should be supervised to ensure that they do not play with the appliance.
9.Please employ the proper power plug, which fit into the power supply cord.
10 .The power plug and connecting cable must have acquired the local attestation.
Outdoor
(INVERTER)
Maximum:D.B/W.B Minimum:D.B/W.B
24oC/18oC
-15oC
2. If the power supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person.
3. If the fuse of indoor unit on PC board is broken,please change it with the type of T. 3.15A/ 250V.
4. The wiring method should be in line with the local wiring standard.
5. After installation, the power plug should be easily reached.
6. The waste battery should be disposed properly.
2
Cautions
Safety Instruction
Please read the following Safety Instructions carefully prior to use.
The instructions are classified into two levels, WARNING and CAUTION according to the seriousness of possible risks and damages as follows. Compliance to the instructions are strictly required for safety use.
Installation
WARNING
Please call Sales/Service Shop for the Installation.
Do not attempt to install the air conditioner by yourself because improper works may cause electric shock, fire, water leakage.
lnstallation in a inadequate place may cause accidents. Do not install in the following place.
CAUTION
Connect the earth cable.
earthing
Do not install in the place where there is any possibility of inflammable gas leakage around the unit.
PROHIBITION PROHIBITION
Do not get the unit exposed to vapor or oil steam.
3
Check proper installation of the drainage securely
STRICT ENFORCEMENT
Cautions
When abnormality such as burnt-small found, immediately stop the operation button and contact sales shop.
WARNING
Use an exclusive power source with a circuit breaker
OFF
Connect power supply cord to the outlet completely
STRICT
ENFORCEMENT
Do not use power supply cord in a bundle.
PROHIBITION
Do not start or stop the operation by disconnecting the power supply cord and so on.
PROHIBITION
Do not use for the purpose of storage of food, art work, precise equipment, breeding, or cultivation.
STRICT
ENFORCEMENT
Use the proper voltage
STRICT
ENFORCEMENT
Take care not to damage
the power supply cord.
PROHIBITION
Do not channel the air flow directly at people, especially at infants or the aged.
PROHIBITION
CAUTION
Take fresh air occasionally especially when gas appliance is running at the same time.
Do not use power supply cord
extended or connected in halfway
PROHIBITION
Do not insert objects into the air inlet or outlet.
PROHIBITION
Do not try to repair or reconstruct by yourself.
Do not operate the switch with wet hand.
PROHIBITION
Do not install the unit near a fireplace or other heating apparatus.
PROHIBITION
Do not place animals or plants in the direct path of the air flow
PROHIBITION
STRICT
ENFORCEMENT
Check good condition of the installation stand
PROHIBITION
Do not place any objects on or climb on the unit.
PROHIBITION
4
PROHIBITION
Do not pour water onto the unit for cleaning
PROHIBITION
Do not place flower vase or water containers on the top of the unit.
PROHIBITION
Parts and Functions
Indoor unit
Test running switch(manual)
Used only for test running in cooling
Inlet grille
Air filter
when room temp. is below 16oC. Don't use it in normal operation.
Emergency switch(manual)
Used when remote controller is lost or defective. Unit will run temporarily.
Remote signal receiver
A beeping sound is generated when a signal from remote controller is received.
Vertical flap
Use remote controller to adjust up and down air flow. (Don't adjust it manually.)
Power indicator
Lights up when unit starts.
For model: HSU-18H03/R2(DB)
For model: HSU-22H03/R2(DB)
Outdoor unit
Timer mode indicator
Lights up when Timer operation is selected.
Operation mode indicator
Lights up during compressor running.
Running Indicator Timer Mode Indicator Power Indicator
4
HSU-18H03/R2(DB) HSU-22H03/R2(DB)
OUTLET INLET
CONNECTING PIPING AND ELECTRICAL WIRING DRAIN HOSE
5
Parts and Functions
10. SWING UP/DOWN display
11. LOCK display
12. FAN SPEED display
1. SWING button Used to select up or down air sending direction.
2. HOUR button Used to set clock and timer setting.
3. MODE button Used to select operation mode. AUTO, COOL,DRY, FAN,HEAT.
4. HEALTH button Used to set healthy operation.
5. CLOCK button Used to set correct time.
6. TIMER button Used to select TIMER ON, TIMER OFF, TIMER ON-OFF.
7. RESET When the remote controller appears abnormal, use a sharp pointed article to press this button to reset the remote controller normal
8. HEALTH display
9. SLEEP display
LOW
13. TIMER ON display
14. TEMP button Used to select your desired temperature.
15. Operation mode display
Operation mode AUTO HEAT FANCOOL DRY
Remote controller
16. SIGNAL SENDING display
17. POWER/SOFT display
18. Left/right air flow display
19. TEMP display Remote controller: to display the TEMP. setting.
20. TIMER OFF display
21. CLOCK display
22. FAN button Used to select fan speed: LOW,MED, HI, AUTO
23. ON/OFF button Used for unit start and stop.
24. SLEEP button Used to select sleep mode.
25. SET button Used to confirm timer and clock settings.
26. POWER/SOFT button
27. LOCK Used to lock buttons and LCD display. If pressed, the other buttons will be disabled and the lock condition display appears. Press it once again, lock will be canceled and lock condition display disappears.
28. LIGHT button Colorful display bar of the controlling indoor machine is on and extinguished.
29. CODE Used to select CODE A or B with a press,A or B will be displayed on LCD. Please select A without special explanation.
MED AUTO
HI
NOTE: (1)The following functions and related displays are not available and (2) Cooling only unit do not have functions and displays related with heating.
,
6
Parts and Functions
Clock Set
When unit is started for the first time and after replacing batteries in remote controller, clock should be adjusted as follows:
1. Press CLOCK button,"AM" or "PM" flashes.
2. Press or to set correct time. Each press will increase or decrease 1 min. If the button is kept depressed, time will change quickly.
3. After time setting is confirmed, press SET, "AM" or "PM" stop flashing, while clock starts working.
Remote controller's operation
When in use, put the signal transmission head directly to the receiver hole on the indoor unit.
The distance between the signal transmission head and the receiver hole should be within 7 m without any obstacle as well.
Don't throw or knock the remoter controller.
When electronic-started type fluorescent lamp or change-over type fluorescent lamp or wireless telephone is installed in the room, the receiver is apt to be disturbed in receiving the signals, so the distance to the indoor unit should be shorter.
Loading of the battery
Load the batteries as illustrated right 2 R-03 (7#) batteries
Remove the battery cover:
Slightly press" "area and push down the cover as illustrated.
Load the battery: Be sure that the loading is in line with the "+" / ".
request as illustrated on the bottom of the case. Put on the cover again.
Confirmation indicator:
After pressing power ON/OFF, if no display, reload the batteries. Note:
Full display or unclear display during operation indicates the batteries have been used up. Please change batteries.
Used two new same-typed batteries when loading. If the remote controller can't run normally during operation, please remove the batteries and
reload several minutes later.
Hint:
Remove the batteries in case unit won't be in usage for a long period. If there are any display after taking-out, just need to press reset key.
7
Operation
Health Operation
Remote controller
1. Unit start
Link with electronic power.
Press ON/OFF on the remote controller, unit starts.
The liquid crystal will display the working state of last time (Except Timer, Sleep, Power/Soft and Health airflow).
Then set up the comfortable working state.
2. Select operation mode
Press HEALTH button. For each press, is displayed. The pilot light of health process on the display board is on, hence healthy process begins.
When indoor wind machine is running, it has healthy process function. (It's available under any mode)
3. Unit stop
Press HEALTH button, the health function stops. The pilot light of healthy process on the display board is extinguished.
BRIEF INTRODUCTION TO HEALTH OPERATION
The anion generator in the air conditioner can generate a lot of anion to effectively balance the quantity of position and anion in the air and also to kill bacteria and speed up the dust sediment in the room and finally clean the air in the room.
Note
When the fan in the indoor unit does not work, the health lamp lights up, but the anion generator does not release anion.
8
Operation
Auto Operation
1. Unit start
Remote controller
2.Select operation mode
Link with electronic power.
Press ON/OFF on the remote controller, unit starts.
The liquid crystal will display the working state of last time (Except Timer, Sleep, Power/Soft and Health airflow).
Press MODE button. For each press, operation mode changes as follows:
Remote controller:
AUTO
Then Select Auto operation
COOL DRY FAN HEAT
3.Fan speed selection
Press FAN button. For each press, fan speed changes as follows:
Remote controller:
LOW
Air conditioner is running under displayed wind speed When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.
MED
HI
AUTO
4.Unit stop
Press ON/OFF button, the unit stops. About Auto Operation
Under the mode of auto operation, air conditioner will automatically select Cool or Heat operation according to room temperature.
9
Operation
Cool Operation
Remote controller
1. Unit start
Link with electronic power. Press ON/OFF on the remote controller, unit starts. The liquid crystal will display the working state of last
time (Except Timer, Sleep, Power/Soft and Health airflow).
2.Select operation mode
Press MODE button. For each press, operation mode changes as follows:
Remote controller:
AUTO
Then Select COOL operation
COOL DRY FAN HEAT
3.Select temp.setting
Press TEMP. button
Every time the button is pressed, temp.setting increase 1 C,if kept depressed, it will increase rapidly
Every time the button is pressed, temp.setting increase 1 C,if kept depressed, it will decrease rapidly
Select a desired temperature.
4.Fan speed selection
Press FAN button. For each press, fan speed changes as follows:
Remote controller:
LOW
Air conditioner is running under displayed wind speed When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.
MED
HI
AUTO
5.Unit stop
Press ON/OFF button, the unit stops.
10
Operation
Dry Operation
1. Unit start
Remote controller
2.Select operation mode
Link with electronic power.
Press ON/OFF on the remote controller, unit starts. The liquid crystal will display the working state of last
time (Except Timer, Sleep, Power/Soft and Health airflow).
Press MODE button. For each press, operation mode
changes as follows: Remote controller:
COOL operation starts when room temp.is higher than temp.setting.
Temp.setting+2oC Temp.setting
On reaching temp.setting +2oC unit will run in mild DRY mode.
Ultra-low air flow
AUTO
COOL DRY FAN HEAT
Then Select DRY operation
3.Select temp.setting
Press TEMP. button
Every time the button is pressed, temp.setting increase 1 C,if kept depressed, it will increase rapidly
Every time the button is pressed, temp.setting increase 1 C,if kept depressed, it will decrease rapidly
Select a desired temperature.
4.Fan speed selection
Press FAN button. For each press, fan speed changes as
follows: Remote controller:
LOW
MED
HI
AUTO
Air conditioner is running under displayed wind speed In DRY mode, when room temperature becomes 2OC higher than temp.setting,unit will run intermittently at LOW speed regardless of FAN setting.
5.Unit stop
Press ON/OFF button, the unit stops.
11
Operation
Fan Operation
1. Unit start
Remote controller
2.Select operation mode
Link with electronic power. Press ON/OFF on the remote controller, unit starts.
The liquid crystal will display the working state of last time (Except Timer, Sleep, Power/Soft and Health airflow).
Press MODE button. For each press, operation mode changes as follows:
Remote controller:
AUTO
Then Select FAN operation
COOL DRY FAN HEAT
3.Fan speed selection
Press FAN button. For each press, fan speed changes as follows:
Remote controller:
LOW
MED
HI
4.Unit stop
Press ON/OFF button, the unit stops.
About FAN operation
In FAN operation mode, the unit will not operate in COOL or HEAT mode but only in FAN mode ,AUTO is not available in FAN mode.And temp.setting is disabled. In FAN mode,SLEEP operation is not available.
12
Operation
Heat Operation
Remote controller
6
1. Unit start
Link with electronic power.
Press ON/OFF on the remote controller, unit starts. The liquid crystal will display the working state of last time (Except Timer, Sleep, Power/Soft and Health airflow).
2.Select operation mode
Press MODE button. For each press, operation mode changes as follows:
Remote controller:
AUTO
Then Select HEAT operation
COOL DRY FAN HEAT
3.Select temp.setting
Press TEMP. button
Every time the button is pressed, temp.setting increase 1 C,if kept depressed, it will increase rapidly.
Every time the button is pressed, temp.setting increase 1 C,if kept depressed, it will decrease rapidly.
Select a desired temperature.
4.Fan speed selection
Press FAN button. For each press, fan speed changes as follows:
Remote controller:
LOW
MED
Air conditioner is running under displayed wind speed IN HEAT mode, warm air will blow out after a short period of the time due to cold-draft prevention function.
When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.
HI
AUTO
13
Operation
(5)Air flow direction adjustment
After operation mode is selected, vertical flap will open automatically according to the mode. Referring to the Fig.
COOL
About 10
o
Up and down (Use remote controller)
Press SWING button, vertical flap will move within the range shown in the Fig. Press SWING button stop it at a fixed position.
o
o
o
COOL
HEAT
About 10
About 45
About 60
Cautions:
It is advisable not to keep vertical flap at downward position for a long time in COOL or DRY mode, otherwise, condensate water might occur.
(6)Unit stop
Press ON/OFF button. Only time remains on LCD. All indicators on indoor unit go out. Vertical flap closes automatically.
HEAT
About 60
o
Left and right air flow adjustment (manual)
Move the horizontal blade by a knob on air conditioner to adjust left and right direction referring to Fig.
Cautions:
When humidity is high, condensate water might occur at air outlet if all horizontal louvers are adjusted to left or right.
Cautions:
Unit won't restart until 3 minutes have elapsed, due to system protection. HEAT mode is not available on cooling only unit.
Hints
As cold air flows downward in COOL mode, adjusting air flow horizontally will be much more helpful for a better air circulation. As warm air flows upward in HEAT mode, adjusting air flow downward will be much more helpful for a better air circulation. Be careful not to catch a cold when cold air blows downward. It is harmful to your health in summer to go frequently in and out of places where temp. difference is above 7oC. Temp. difference of 3-5oC will remove your fatigue. More than this, unit's load can be reduced and power consumption cut down as well. So, you'd better set a temp. difference of 3-5oC between indoor and outdoor temp. in COOL mode.
14
Operation
Sleep Operation
Before going to bed, you can simply press the SLEEP button and unit will operate in SLEEP mode and bring you a sound sleep. Use of SLEEP function After the unit starts, set the operation status, then press SLEEP button before which the clock must be adjusted and time being set. Operation Mode
1. In COOL,DRY mode 1 hours after SLEEP mode starts, temp. will become 1OC higher than temp. setting. After another 1 hours, temp. rises by 1OC further. The unit will run for further 6 hours then stops. Temp. is higher than temp. setting so that room temperature won't be too Iow for your sleep.
Remote Controller
SLEEP operation starts SLEEP operation stops
Approx.6hrs
Rises 1OC
1 hr
Rises 1OC
1 hr
Temp.setting
In HEAT mode
2.
In COOL, DRY mode
Unit stop
1 hours after SLEEP mode starts, temp will become 2 OC lower than temp. setting. After another 1 hours, temp decrease by 2 OC further. After more another 3 hours, temp. rises by 1OC further. The unit will run for further 3 hours then stops. Temp. is lower than temp. setting so that room temperature won't be too high for your sleep.
Temp.setting
SLEEP operation starts
In AUTO mode
3.
1 hr
Decreases 2OC
1 hr
Decreases 2OC
3 hrs
In HEAT mode
Unit stop
3 hrs
Rises 1OC
SLEEP operation stops
The unit operates in corresponding sleep mode adapted to the automatically selected operation mode.
4. In FAN mode It has no SLEEP function.
Note
The sleeping hours lasts 8 hours and couldn't be adjusted. When timing on function is set, the sleeping function can't be set up After the sleeping function is set up, if user resets timing on function, the sleeping function will be cancelled; the machine will be in the state of timing-on. If the sleeping function and timing-on function are set up at the same time, no matter which one is operated earlier, the machine will be off automatically, and the other function will also be cancelled.
15
Operation
Timer On/Off Operation
Set clock correctly before starting TIMER operation.
Remote Controller
1. After unit starts, select your desired operation mode Operation mode will be displayed on LCD.
2. Timer mode selection Press TIMER button to change TIMER mode. Every time the button is pressed, display changes as follows: Remote controller:
Then select your desired TIMER mode (TIMER ON or TIMER OFF). " "or " "will flash.
3.Time setting Press HOUR button.
Every time the button is pressed, time setting increases 1 min, if kept depressed, it will increase rapidly. Every time the button is pressed, time setting decreases 1 min, if kept depressed, it will decrease rapidly. It can be adjusted within 24 hours.
4.Confirming your setting
After setting correct time, press SET button to confirm " "or" "on the remote controller stops flashing. Time displayed: Unit starts or stops at x hour x min. (TIMER ON or TIMER OFF).
BLANK
TIMER ON TIMER OFF TIMER ON-OFF
5.Cancel TIMER mode
Just press TIMER button several times until TIMER mode disappears.
Hints: After replacing batteries or a power failure happens, time setting should be reset. Remote controller possesses memory function, when use TIMER mode next time,just press SET button after mode selecting if time setting is the same as previous one.
16
Operation
Timer On-Off Operation
Set clock correctly before starting TIMER operation.
1. After unit starts, select your desired operation mode Operation mode will be displayed on LCD.
Remote Controller
2. Timer mode selection Press TIMER button to change TIMER mode. Every time the button is pressed, display changes as follows: Remote controller:
Then select your desired TIMER mode (TIMER ON - OFF). " "will flash.
3.Time setting Press HOUR button.
Every time the button is pressed, time setting increases 1 min, if kept depressed, it will increase rapidly. Every time the button is pressed, time setting decreases 1 min, if kept depressed, it will decrease rapidlly. It can be adjusted within 24 hours.
BLANK
TIMER ON TIMER OFF TIMER ON-OFF
4.Timer confirming for TIMER ON
After setting correct time, press TIMER button to confirm " " on the remote controller stops flashing. " " starts flashing. Time displayed: Unit starts or stops at x hour x min.
5.Time setting for TIMER OFF
Just press HOUR button ,follow the same procedure in "Time setting for TIMER ON"
6.Time confirming for TIMER OFF
After time setting,press SET button to confirm. " " on the remote controller stops blinking. Time displayed:Unit stops at x hour x min.
To cancel TIMER mode
Just press TIMER button several times until TIMER mode disappears. According to the Time setting sequence of TIMER ON or TIMER OFF, either Start-Stop or Stop-Start can be achieved.
17
Operation
POWER/SOFT Operation
POWER Operation
When you need rapid heating or cooling, you can use this funciton.
Selecting of POWER operation
Press POWER/SOFT button. Every time the button is pressed,display
changes as follows:
Stop the display at
In POWER operation status:
In HEAT or COOL mode, fan speed automatically runs in HI mode for 15 min then returns to original status setting.
To cancel POWER operation
Press POWER/SOFT button twice ,POWER/SOFT disappears.
POWER
BLANK
SOFT
SOFT Operation
You can use this function when silence is needed for rest or reading.
Selecting of SOFT operation
Press POWER/SOFT button. Every time the button is pressed,display
changes as follows:
POWER
Stop the display at
In SOFT operation mode, fan speed automatically takes"LOW"
To cancel POWER operation
Press POWER/SOFT button twice ,POWER/SOFT disappears. Hints:
During POWER operation, in rapid HEAT or COOL mode, the roor will show inhomogeneous temperature distribution. Long period SOFT operation will cause effect of not too cool or not too warm.
SOFT
BLANK
18
Operation
Emergency and Test Operation
Emergency operation:
Use this operation only when the remote controller is defective or lost.
When the emergency operation switch is pressed,the" Pi "sound is heard once, which means the start of this operation.
In this operation, the system automatically selects the operation modes, cooling or heating, according to the room temperature.
When machine is running in emergency, the set value of temperature and wind speed couldn't be altered; meanwhile, it can't operate for dehumidifying or under timing mode.
Pi
Test operation:
Test operation switch is the same as emergency switch.
Use this switch in the test operation when the room temperature is below 16OC, do not use it in the normal operation.
Continue to press the test operation switch for more than 5 seconds. After you hear the "Pi" sound twice, release your finger from the switch: the cooling operation starts with the air flow speed "Hi".
Removal of the restriction of emergency or test operation
Press the emergency operation switch once more, or manipulate through the remote controller; the "Pi" sound, the emergency or test operation is terminated.
When the remote controller is manipulated, it gets the system back to the normal operation mode.
19
Pi...Pi Pi
Maintenance
For Smart Use of The Air Conditioner
Setting of proper room temperature
Proper temperature
Close doors and windows during operation
During cooling operation, prevent the penetration of direct sunlight with curtain or blind.
Do not block the air inlet or outlet
Use the timer effectively
If the unit is not to be used for a long time, turn off the power supply main switch.
OFF
Use the louvers effectively
20
Maintenance
For Smart Use of The Air Conditioner
WARNING
Before maintenance,be sure to turn off the system and the circuit breaker.
Remote Controller
Do not use water, wipe the controller with a dry cloth.Do not use glass cleaner or chemical cloth.
Do not use the following for cleaning
Gasoline,benzine, thinner or cleanser may damage the coating of the unit.
Air Filter cleaning
Open the inlet grille by pulling it upward.
Indoor Body
Wipe the air conditioner by using a soft and dry cloth.For serious stains,use a neutral detergent diluted with water.Wring the water out of the cloth before wiping.then wipe off the detergent completely.
Hot water over 40OC(104OC) may cause discoloring or deformation.
Remove the filter.
Push up the filter's center tab slightly until it is released from the stopper, and remove the filter downward.
Clean the filter.
Use a vacuum cleaner to remove dust, or wash the filter with water.After washing, dry the filter completely in the shade.
Attach the filter.
Attach the filter correctly so that the "FRONT" indication is facing to the front.Make sure that the filter is completely fixed behind the stopper.If the right and left filters are not attached correctly, that may cause defects.
Close the inlet grille.
21
Air Filter
Once every two weeks
Maintenance
Replacement of Air Purifying Filter
1.Open the lnlet Grille
Open the inlet grille by pushing each ends of the inlet grille upward.(use thumbs to push up)
2.Detach the standard air filter
Slide the knob slightly upward to release the filter, then withdraw it.
3.Detach the Air Purifying Filter
Replace the old filter with new one into the frame.
4.Attach new Air Purifying Filter
Attaching each of the Air Purifying Filter to the indoor unit as its white side faces to the front .
5.Attach the standard air filter as its front side faces to the front
Operating without standard air filter may cause troubles with the machine.
6.Close the Inlet Grille
Close the Grille surely
NOTE:
Please replace the air Purifying Filter when color of the filter become same levle of sample attached in the indoor unit.
Please replace the air Purifying Filter in 3-6 months as standard. Stuffed filter are not usable even washing.Please purchase new one at sales shop.
22
Maintenance
To Keep Your Air conditioner in Good Condition after Season.
Operate in cooling mode for 2-3 hours.
To prevent breeding mold or bad smell, be sure to operate at the designated temperature or 30OC,cooling mode and High speed fan mode for 2-3 hours.
Put off the power supply cord.
Cleaning the body.
Take out the batteries from the wireless remote controller.
23
Maintenance
Before Setting in High season
Cleaning the standard air filter.
Operation without filter may cause troubles.Be sure to attach both right and left filters prior to the operation. Each of them are of different shapes.
Connecting the earthing cable.
Caution
Incomplete earthing may cause an electric shock.
Do not block the air inlet or outlet.
Plug-in
Caution
After brush away dust at the plug, insert the plug of the power supply cord into the outlet completely.In case of suing exclusive circuit breaker,switch on the circuit breaker.
EARTHING
NO WET HAND
24
Trouble shooting
Before asking for service, check the following first.
Normal Performanc e inspection
Phenomenon
The system does not restart immediately.
Noise is heard:
Smells are generated.
Mist or steam are blown out.
Cause or check points
When unit is stopped, it won't restart immediately until 3 minutes have elapsed to protect the system. When the electric plug is pulled out and reinserted, the protection circuit will work for 3 minutes to protect the air conditioner.
During unit operation or at stop, a swishing or gurgling noise may be heard. At first 2-3 minutes after unit start, this noise is more noticeable. (This noise is generated by refrigerant flowing in the system.) During unit operation, a cracking noise may be heard. This noise is generated by the casing expanding or shrinking because of temperature changes. Should there be a big noise from air flow in unit operation, air filter may be too dirty.
This is because the system circulates smells from the interior air such as the smell of furniture, cigarettes.
During COOL or DRY operation, indoor unit may blow out mist. This is due to the sudden cooling of indoor air.
Multiple check
Does not work at all.
Poor cooling
Is power plug inserted? Is there a power failure? Is fuse blown out?
Is the air filter dirty? Normally it should be cleaned every 15 days. Are there any obstacles before inlet and outlet? Is temperature set correctly? Are there some doors or windows left open? Is there any direct sunlight through the window during the cooling operation?(Use curtain) Are there too much heat sources or too many people in the room during cooling operation?
25
Loading...