Haier HSU-22HA03/Z1, HSU-22H03I User Manual

SPLIT TYPE ROOM AIR CONDITIONER
OPERATION MANUAL
HSU-09C03/Z1 HSU-12C03/Z1 HSU-09H03/Z1 HSU-12H03/Z1 HSU-12HA03/Z1
HSU-22HA03/Z1
Please read this operation manual before using the air conditioner.
No.0010552113A
Contents
Cautions Parts and functions Operation
Maintenance Trouble shooting
5-12 13-14
15
Cautions
The machine is adaptive in following situation
I. Applicable ambient temperature range:
Indoor
Cooling
Outdoor
Indoor
Heating
Outdoor
2. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. The type of connecting wire is H05RN-F or H07RN-F
3. If the fuse on PC board is broken please change it with the type of T. 3.15A/250V.
4. The distance between the indoor unit and the floor should be more than 2m.
5. The wiring method should be in line with the local wiring standard.
6. After installation, the power plug should be easily reached.
7. The waste battery should be disposed properly.
8. The appliance is not intended to use by young children or infirm persons without supervision.
9.Young children should be supervised ensure that they do not play with the appliance.
10.The appliance must be installed on strong enough supporter.
11.The wiring diagram is attached inside the machine.
Maximum: D.B / W.B 32oC/23oC Minimum: D.B / W.B
Maximum: D.B Minimum: D.B Maximum: D.B
Minimum: D.B Maximum: D.B / W.B Minimum: D.B / W.B
18oC/14oC 43oC/26oC
18oC 27oC
15oC 24oC/18oC
-7oC/-8oC
1
Parts and Functions
Indoor Unit
Test running switch(manual)
Inlet grille
Inlet
Air Purifying Filter
(inside)
Horizontal louver(inside)
(adjust left and right air flow)
Used only for test running in cooling when room temp. is below 16oC. Don't use it in normal operation.
Emergency switch(manual)
Used when remote controller is lost or defective. Unit will run temporarily.
Remote signal receiver
A beeping sound is generated when a signal from remote controller is received.
Vertical louver
Use remote controller to adjust up and down air flow. (Don't adjust it manually.)
Actual inlet grille may vary from the one shown in the manual according to the product purchased
Outdoor Unit
Power indicator
Lights up when unit starts.
Timer mode indicator
Lights up when Timer operation is selected.
Operation mode indicator
Lights up during compressor running.
HSU-09C03/Z1 HSU-09H03/Z1 HSU-12HA03/Z1
HSU-12C03/Z1 HSU-12H03/Z1
OUTLET
INLET
HSU-22HA03/Z1
CONNECTING PIPING AND ELECTRICAL WIRING DRAIN HOSE
2
Parts and Functions
Operation
1
2 3
4
11
12
13 14
15
16
17
Clock set
ON/OFF
MODE SET
FAN
SWING
SLEEP
LOCK RESET
A U T O
Buttons and display of the remote controller.
1. Mode display AUTO
COOL DRY HEAT FAN
2. SWING display
3. FAN SPEED display
4. SLEEP display
5. LOCK display
6. SIGNAL SENDING
7. TIMER OFF display
8. TIMER ON display
9. CLOCK display
10. TEMP display
11. POWER ON/OFF
Used for unit start and stop.
12. MODE
Used to select AUTO run, COOL, DRY, HEAT and FAN operation
13. FAN
Used to select fan speed LO, MED, HI, AUTO
14. HOUR
Used to set clock and timer setting.
15. SWING
Used to set auto fan direction.
16. SLEEP
Used to select sleep mode.
17. LOCK
Used to lock buttons and LCD display.
18. TEMP.
Used to select your desired temp.
19. SET
Used to confirm timer and clock settings.
20. TIMER
Used to select TIMER ON, TIMER OFF, TIMER ON-OFF
21. CLOCK
Used to set correct time
22. RESET
Used to reset the controller back to
normal condition.
AM
o
PM
C
TEMP
TIMER
CLOCK
ON OFF
5 6
7
8
9
10
18 19
20
21
22
When unit is started for the first time and after replacing batteries in remote controller, clock should be adjusted as follows: Press CLOCK button, "AM" or "PM" flashes. Press or to set correct time. Each press will increase or decrease 1min. If the button is kept depressed, time will change quickly. After time setting is confirmed, press SET, "AM "and "PM" stop flashing, while clock starts working.
NOTE: Cooling only unit do not have displays and functions related with heating
LO MED HIAUTO
Hints
After replacing with new batteries, remote controller will conduct self-check, displaying all information on LCD. Then, it will become normal.
3
Parts and Functions
Operation
Buttons and display of the remote controller.
If the unit which you purchased has healthy function, Remote controller should
like the following figure:
1
ON
2 3
A U T O
OFF
AM
o
PM
C
4
ON/OFF TEMP
11
MODE SET
12
13 14
15
16
17
FAN TIMER
SWING CLOCK
SLEEP
HEALTH
LOCK RESET
BRIEF INTRODUCTION TO HEALTH OPERATION
The anion generator in the air conditioner can generate a lot of anion to effectively balance the quantity of position and anion in the air and also to kill bacteria and speed up the dust sediment in the room and finally clean the air in the room.
NOTE: Cooling only unit do not have displays and functions related with heating
5 6
7 8 9
10
18 19
20
21
22
1. Mode display AUTO
COOL
DRY
HEAT
FAN
2. SWING display
3. FAN SPEED display
4. SLEEP display
5. LOCK display
6. SIGNAL SENDING
7. TIMER OFF display
8. TIMER ON display
9. CLOCK display
10. TEMP display
11. POWER ON/OFF
Used for unit start and stop.
12. MODE
Used to select AUTO run, COOL, DRY, HEAT and FAN operation
13. FAN
Used to select fan speed LO, MED, HI, AUTO
14. HOUR
Used to set clock and timer setting.
15. SWING
Used to set auto fan direction.
16. SLEEP
Used to select sleep mode.
17. LOCK
Used to lock buttons and LCD display.
18. TEMP.
Used to select your desired temp.
19. SET
Used to confirm timer and clock settings.
20. TIMER
Used to select TIMER ON, TIMER OFF, TIMER ON-OFF
21. CLOCK
Used to set correct time
22. RESET
Used to reset the controller back to normal condition.
23. HEALTH
Used to set healthy operation
AUTO
MED
LO
HI
Hints
After replacing with new batteries, remote controller will conduct self-check, displaying all information on LCD. Then, it will become normal.
4
Loading...
+ 11 hidden pages