Haier HSU24VHG-G, HSU09VHG-W, HSU12VHG-W, HSU18VHG-W, HSU24VHG-W Operation Manual

...
Please read this operation manual before using the air conditioner.
Keep this operation manual for future reference.
SPLITTYPEROOMAIRCONDITIONER OPERATION MANUAL
HSU218VHG-W is variable-speed multi-split heat pump while others variable-speed mini-split.
6
1
2 5
Contents
8 9
12 13
Table des matières
15
20
16 19
PARTS AND FUNCTIONS OPERATION
MAINTENANCE CAUTIONS
TROUBLE SHOOTING
7
MANTENIMIENTO PRECAUCIONES RESOLUCIÓN DE PROBLEMAS
PARTES Y FUNCIONES FUNCIONAMIENTO
14
ÉLÉMENTS ET FONCTIONS UTILISATION
ENTRETIEN MISES EN GARDE DÉPANNAGE
21
HSU09VHG(DB)-G HSU12VHG(DB)-G HSU18VHG(DB)-G HSU24VHG(DB)-G
HSU09VHG(DB)-W HSU12VHG(DB)-W HSU18VHG(DB)-W HSU24VHG(DB)-W
HSU109VHG-G HSU-09HEG03/R2(DB)
HSU218VHG-W 2HUM18HC03/R2(DB)
Dual
HSU112VHG-G
AS12GS1ERA
The unit pictured above is for reference only. Your product may appear different.
4
Outdoor Unit
Inserting the Battery
Parts and Functions
Indoor Unit
OUTLET
INLET
CONNECTING PIPING AND ELECTRICAL WIRING
DRAIN HOSE
Remote Control
Hint: Remove the batteries if the unit won't be in use for a long period. If there is any display after taking-out the batteries, just press reset key.
The unit pictured above is for reference only. Your product may appear different.
Display board
(adjust left and
Vertical louvers
right air flow)
Air Purifying Filter
Inlet
(inside)
Emergency
Switch
Horizontal louver
Outlet
Front Cover
Display board
1
4
2
3
5
Signal receiver hole
ON/OFF display
4
2 3
1
5
TIMER ON display SLEEP display
Ambient temp.display
When receiving the remote
control signal, display the set
displayed and this room
display. The room temperature is
temperature will be shown in the
temperature is only for reference.
Note to the Auto restart function:
Press the sleep button ten times in five seconds and enter the function after hearing four sounds. Press the sleep button ten times within five seconds and leave this function after hearing
TIMER OFF display
COOL\HEAT\DRY\AUTO display
two sounds.
1. Mode display
2. Signal sending display
4.FAN SPEED display
5. LOCK display
6.TIMER OFF display TIMER ON display
LO MED HI
7.TEMP display
16. LOCK button
Used to lock buttons and LCD display.
25. RESET button If the remote is not functioning properly,
use a pen point or similar object to depress the button to reset the remote
22. HOUR button
Operation mode
NAFOTUA COOL DRY
Remote controller
HEAT
1
2 3
4 5 9
10 11
12 13
14 15 16
17
22 23
24
25
19 20
21
8
18
7
6
Control the lightening and extinguishing of the indoor LED display board.
3. SWING display
8
.
9. QUIET button
10. HEAT button
11. COOL button
12. AUTO button
13. FAN button
14. TIMER button
15. HEALTH button
17. LIGHT button
18. POWER ON/OFF button
19. DRY button
20. TEMP button
21. SWING button
23. EXTRA FUNCTION button
24.CANCEL/CONFIRM button
AUTO
Function: Setting and cancel to the timer and other additional functions.
Display circulated
Operation mode
Remote controller
QUITE
POWER
SLEEP
HEALTH
Additional functions display
Healthy function is not available for some units.
(adjust up and down air flow Don’t adjust it manually)
1
1 2
3
4
Remove the battery cover;
Insert the batteries as illustrated.
2 AAA batteries.
+ -.
Then put on the cover again.
Note:
Be sure battery polarity is correct
The distance from the remote to the receiver should be less than 23 feet (7 meters) with no obstructions. Fluorescent lights or cordless telephones will reduce the range of the remote. If the display is dim the remote batteries may need to be replaced. Remote malfunctions can sometimes be corrected by removing the batteries for a few minutes and then replacing them.
FunctionFan Mode— Healthy airflow upwarder — Healthy airflow downwarder— Reset the healthy airflow position — Right & left airflow setting— A-B yard— 10 low temperature heating— Sleep Mode— Electrical Heating— Refresh Air— Power — Fahrenheit/Celsius mode shift on unit and remote Remark:A-B yard, Right & left airflow setting, 10 low temperature heating, Electrical Heating, Refresh Air functions are not available for this mini split series.
Operation
Air Flow Direction Adjustment
Press FAN button. For each press, fan speed
follows:
Remote controller:
Press
button
Every time the button is pressed, temp.setting increase 1
o
C / 2 F, if kept depressed, it will
increase rapidly
Every time the button is pressed, temp.setting
decrease 1
o
C / 2 F, if kept depressed, it will
decrease rapidly
Select a desired temperature.
4.Fan speed selection
3.Select temp.setting
The air conditioner will be running at the speed shown in the display. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.
1. Unit start
Press ON/OFF on the remote controller, unit starts.
Basic Operation
Remote controller
1.Status display of air flow
When restarting the unit after it has been turned off, the unit will keep the swing position before it stops working.
2.Left and right air flow adjustment
(manual)
Cautions:
When adjusting the louver by hand,turn off the unit. When humidity is high,condensate water might occur
adjusted to left or
It is advisable not to keep horizontal louver at downward position for a long time in COOL or DRY
mode ,otherwise, condensate water might occur.
Emergency Operation and Test Operation
at air outlet if all vertical louvers are right.
Note:
changes as
Operation
Mode
Remote
Controller
Note
In DRY mode, when room temperature is 2 C/4 F degrees
o
less than the temperature set point, the unit will run intermittently at LOW speed regardless of FAN setting.
Under the mode of auto operation, air conditioner will automatically select Cool or Heat operation according to
room temperature. When FAN is set to AUTO the air conditioner automatically adjusts the fan speed according to room temperature.
In FAN operation mode, the unit will not operate in COOL or HEAT mode but only in
FAN mode, AUTO is not available in FAN mode. And temp. setting is disabled. In FAN mode, sleep operation is not available.
Emergency Operation:
Use this operation only when the remote controller is defective or lost, and with function of emergency running, air conditoner can run automatically in few seconds.
When power switch is turned on for the first time and emergency operation starts, the unit will run automatically in the following modes:
Room temperature
Designated temperature
Timer mode
Fan
speed
Operation
mode
Above 23ą/73ȯ26ą/ 79ȯ Below 23ą/73ȯ23ą/ 73ȯ
No
AUTO AUTO
COOL HEAT
No
During emergency operation it is impossible to change the settings of temp. and fan speed,It is also not possible to
operate in Timer or Dry mode.
the room
temperature is below 16
ą/ 60ȯ
,
Test Operation:
Use this switch in the test operation when
do not use it in the normal operation.
Test operation switch is the same as emergency switch.
Under this operation mode,the fan motor of indoor unit will run in high speed.
LOW
MED HI
COOL/DRY:
HEAT:
Initial state
AUTO
2.Select operation mode
COOL button:Cooling mode HEAT button: Heating mode DRY button: Dehumidify mode
Beep
DRY
COOL
AUTO
HEAT
FAN
In HEAT mode, warm air will blow out after a short period of the time due to cold-draft prevention function. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.
2
When the emergency operation switch is pressed, the unit beeps once, which starts the operation.
from the switch: the cooling operation
Continue to press the test operation
switch for more than 5 seconds.After
you hear two beeps, release your finger
starts with the air flow speed "HI".
Move the vertical louver by a knob on air to adjust left and right direction to achieve stereoscopic air flow as the figure below.
conditioner
o
o
A U T O
o
Beep-Beep
stereoscopic air flow
Operation
Sleep Operation
5.Fan Speed in Sleep Mode
When the unit is set to sleep mode, the fan speed will be set to low speed and it cannot be changed.
Operation Mode
1. In COOL,DRY mode
SLEEP operation starts SLEEP operation stops
SLEEP operation starts
SLEEP operation stops
Approx.6hrs
1 hr
1 hr
1 hr
3 hrs
3 hrs
Rises 1OC/ 2 F
Rises 1
O
C/ 2 F
Rises 1OC/ 2 F
Temp.setting
Temp.setting
Unit stop
Unit stop
In COOL, DRY mode
In HEAT mode
Decreases 2OC/ 4 F
Decreases 2
O
C/ 4 F
1 hr
2.
3.
In HEAT mode
In AUTO mode
4. In FAN mode
It has no SLEEP function.
Note
When TIMER function is set, the sleep function can’t be set up .After the sleep function is set up, if user set up TIMER function, the sleep function will be cancelled; the machine will be in the state of timing-on.
Power/Quiet Operation
1 hour after SLEEP mode starts,temp.will become higher than temp.setting.After another 1 hour,temp.rises by 1 / 2 F futher. The unit will run for an additional 6 hours then stops Temp. is higher than temp.setting so that room temperature won’t be too low for your sleep.
1 hour after SLEEP mode starts,temp will become 2 4 F lower than temp.setting.After another 1 hour,temp decrease by 2
C / 4 F futher.After more another 3 hours,
temp.
rises by 1 C / 2 F futher.The unit will run for an additional 3 hours then stops.Temp.is lower than temp. setting so that room temperature won’t be too high for your sleep.
If the unit is running cooling, the sleep mode will follow the function as in cool mode, while follow as in heat mode.
O
C
O
O
1
O
C/2 F
O
C /
Press button to enter additional options, cycle the display to , will flash. And then press enter for sleep function.
(1)
Power Operation
(2)
Quiet Operation
Note
When you need rapid heating or cooling, you can use this function.
You can use this function when silence is needed for rest or
Running the unit in QUIET mode for a long period may cause the room temperature to not reach the set temperature. If this occurs, cancel QUITE mode and set the fan speed to a higher setting.
reading.Press QUIET button, the remote controller will show , and then achieve to the quiet function. To cancel this function, press the QUIET button.
Press button to enter additional options, cycle the display to , will flashand then press ,enter to power function. To cancel this function, please select a different option.
3
O
O
O
O
O
O
O
O
O
O
Operation
1.After unit starts, select your desired operation mode.
2.Press TIMER button to change TIMER mode. Every time the button is pressed, display changes as follows: Remote controller:
BLANK
TIMER ON TIMER OFF TIMER ON-OFF
Then select your desired TIMER mode (TIMER ON or TIMER OFF or TIMER ON-OFF). " "or " "will flash.
3.Press / button to set time.
It can be adjusted within 24 hours.
Hints:
After replacing batteries or a power failure happens, time
setting should be reset. According to the Time setting sequence of TIMER ON or TIMER OFF, either Start-Stop or Stop-Start can be achieved.
Timer On/Off On-Off Operation
Healthy Airflow Operation
1.Press to start
Setting for comfortable conditions.
2.The setting of healthy airflow function
Note:
1.After setting the healthy airflow function, the position
louver is fixed.
4.In cooling and dry, using the air conditioner for a long time under the high air humidity, condensate water may occur at the grille .
3.To cancel of the healthy airflow function
Notice: Do not direct the horizontal louver by hand. This may cause the louver to run incorrectly and not match the display. If the louver is not running correctly, stop the unit
for a minute and then restart and adjust remote controller.
2.In heating, it is better to select the
3.In cooling, it is better to select the
mode.
mode.
TIMER OFF-ON
0.5h
0.5h 0.5h
0.5h
Press the button for each time, setting time in the first 12 hours increased by 0.5 hour every time, after 12 hours,increased by 1 hour every time.
Press the button for each time, setting time in the first 12 hours decreased by 0.5 hour every time, after 12 hours,decreased by 1 hour every time.
After adjusting the time,press button and confirm the time the ON or OFF button will not flash any more.
4.Confirm timer setting
5.Cancel timer setting Press the timer button until the time display eliminated.
Press button to enter additional options,Press this button continuously, the louvers location will cycle between the following three locations, to choose the swing location what you want, then button to confirm.
Press button to enter additional options,Press this button continuously, the louvers location will cycle between the three locations again, then button to cancel.
Healthy airflow upwarder
Healthy airflow downwarder
Present position
4
Maintenance
Setting of proper room temperature
Close doors and windows during operation
If the unit is not to be used for a long time, turn off the power supply mainswitch.
Use the timer effectively
Use the louvers effectively
Do not block the air inlet or outlet
Proper
temperature
During cooling operation
prevent the penetration of
direct sunlight with
curtain or blind
OFF
Remote Controller Indoor Unit
1.Open the lnlet Grille
2.Detach the Standard Air Filter
3.Attach Air Purifying Filter
4.Attach the standard air filter
(Necessar
y installation)
5.Close the Inlet Grille
Close the inlet grille securely
Slide the knob slightly up
ward to
release the filter, then withdraw it.
Put air purifying filter into the
right and left filter frames.
NOTE:
The photocatalyst air purifying filter will be solarized in fixed time. In normal use, it will be solarized every 6 months.
Prop up the inlet grille by using the
grille-support located an the right
ATTENTION:
Please keep the bacteria-killing medium air purifying filter
The bacteria-killing medium air purifying filter will be used for a long time,no need for replacement. But in the period of using them ,you should remove the dust frequently by
side of the indoor unit.
using vacuum cleaner or flapping them lightly,otherwise ,
its performance will be affected.
cool and dry. Avoid long term exposure to sunlight when not in use as its ability to sterilize will be reduced.
For Smart Use ofThe Air Conditioner
Replacement of Air Purifying Filter
The white side of the photocatalyst air purifying filter faces outside,and the black side faces the unit The green
side of the bacteria-killing medium air purifying filter faces outside,and the white side faces the unit.
Do not use water, wipe the remote with a dry cloth. Do not use glass cleaner or a chemicals.
Wipe the air conditioner by using a soft and dry cloth.For serious stains,
use a neutral detergent diluted with water.Wring the water out of the cloth before wiping,then wipe off the detergent completely.
Air Filter Cleaning
Open the inlet grille by pulling it upward.
Remove the filter.
Clean the filter.
Attach the filter.
Close the inlet grille.
Push up the filter's center tab slightly until it is
from the stopper, and remove the filter do
wnw
ard.
Use a vacuum cleaner to remove dust, or wash the filter with water.After washing, dry the filter completely before putting it back in
Attach the filter correctly so that the "FRONT" indication
facing to the front.Make sure that the filter is
fixed behind the stopper.If the right
attached correctly, that
Do not use the following for cleaning
Gasoline,benzine, thinner or cleanser
ay
damage the coating of the unit.
Hot waterover 40
O
C(104OF) may
discoloring or deformation.
Once every two weeks
m
cause
released
is
completely
and left filters are not may cause defects.
Detach old Air Purifying Filter
5
the unit.
Loading...
+ 15 hidden pages