Hammerƽ
Nipperƽ
HacksawƽPipe cutterƽ
Hole core drillƽFlaring toolƽ
Spanner(17,19 and 26mm)ƽKnifeƽ
Gas leakage detector orƽ
soap-and-water solution
ƽ
(17mm,2 2mm, 26m m)
Measuring tapeƽ
Reamerƽ
Power Source
ƽ
Before inserting power plug into receptacle, check the voltage without fail.
The
Install an exclusive branch circuit of the power.
ƽ
A receptacle shall be set up in a distance where the power cable can be
ƽ
reached.
source is the same as the
power
Donotextendthecablebycuttingit.
corresponding name plate.
Drawing for the installation of indoor and outdoor units
ThemodelsadoptHCFCfreerefrigerantR410A
more than 10cm
(3 7/8)
more than
10cm
(3 7/8)
Selection of Installation Place
Indoor Unit - Select a plocation that is
Robust not causing vibration, where the body can be supported sufficiently.
ƽ
Not affected by heat or steam generated in the vicinity, where inlet and outlet of the
ƽ
unit are not disturbed.
Possible to drain easily, where piping can be connected with the outdoor unit.
ƽ
Where cold air can be spread in a room evenly.
ƽ
Nearby a power receptacle. (Refer to drawings).
ƽ
Place where the distance of more than lm from televisions, radios, wireless apparatuses
ƽ
and fluorescent lamps can be left.
In the case of fixing the remote controller on a wall, place where the indoor unit can
ƽ
receive signals when the fluorescent
lamps in the room are in use.
Outdoor Unit - Select a plocation that is
Not less affected by rain or direct sunlight and is sufficiently ventilated.
ƽ
ƽ
Strong enough to bear the unit, where vibration and noise are not increased.
Place, where discharged wind and noise do not cause a nuisance to the neighbors.ƽ
Place, where a distance markedƽ
Attention must be paid to
the pitch of drain hose
isavailableasillustratedintheabovefigure.
Q
Optional parts for piping
Non-adhesive tape
A
Adhesive tape
B
Saddle(L.S)withscrews
C
Connecting electric cable
D
for indoor and outdoor
E
Drain hose
F
Heating insulating material
Piping hole cover
G
Arrangement of piping
directions
Rear left
Left
Below
The marks fromto
G
in the
A
gure are the
parts numbers.
Thedistancebetween
theindoorunitandthe
oorshouldbemore
than 2m.
Rear
right
Right
more than 20cm
more than
(23 5/8)
(7 7/8)
60cm
more than 10cm
(3 7/8)
more than 15cm
(5 7/8)
more than 25cm
A
(9 7/8)
Floor xing dimensions of the
outdoor unit (Unit:mm /
For:HSU18VCK-W
113.5
C
(4 1/2)
184
(7 1/4)
(24 7/8)
For:
HSU24VCK-W
(22 7/8)
633
580
inch)
113.5
(4 1/2)
184
(7 1/4)
340
(13 1/2)
083
(14 15/16)
Fixing of outdoor unit
Fix the unit to concrete or block
with bolts (10mm) and nuts rmly
and horizontally.
tting the unit to wall
When
surface, roof or rooftop, x
asupportersurelywithnails
or wires in consideration of
earthquake and strong wind.
If vibration may affect the
house, x the unit by attaching a
vibration-proof mat.
Please be subject to the actual product purchased , the above picture is just for your reference.
Read this manual before installation
Explain suf
ciently the operating means to the user according to this manual.
NO.0010536243
Accessory parts
Remote controller (1)
AAA dry battery (2)
Mounting plate (1)
Plastic cap (4)
Ø4X25 Screw
(4)
Drain hose (1)
Cushion (4)
Drain-elbow (1)
Pipe supporting plate (1)
Selection of pipe
Type
Liquid pipe (Ø)
Gas pipe (Ø)
NOTE˖The thickness of the pipe must be 0.8mm(1/16”) at least.
For 18K
6.35mm(1/4”)
12.7mm
(1/2”)
For 24K
9.52mm(3/8”)
15.88mm
(5/8”)
Indoor unit
FittingoftheMountingPlateand
When the mounting plate is first fixed
1. Carry out, based on the neighboring pillars or lintels, a
to be fixed against the wall, then temporarily fasten the plate with one steel nail.
2. Make sure once more the proper level of the plate, by
weight from the central top of the plate, then fasten securely the plate with the
attachment steel nail.
3. Find the wall hole location A using a measuring tape
PositioningofthewallHole
proper leveling for the plate
hanging a thread with a
1. Insert the drain hose into the dent of heat insulation materials of indoor unit.
2. Insert the indoor/outdoor electric cable from backside of indoor
outonthefrontside,thenconnect them.
In case of left side piping, cut away, with a nipper, the lid for left piping.
In case of left-rear piping, bend the pipes according to the piping direction to
ƽ
the mark of hole for left-rear piping which is marked on heat insulation materials.
2
Conduit holder
When connecting the cable, confirm the terminal number of indoor and
Note
outdoor units carefully. If wiring is not correct, proper operation can not
be carried out and will cause damage to the units.
Cut the 6 slit sear
HSU18VCK-W
HSU24VCK-W
1.IfthefuseonPCboardisbrokenpleasechangeitwiththe
T. 3.15A/250V (indoor unit), 25A/250V(outdoor unit).
2. The wiring method should be in line with the local wiring standard.
3. After installation, the power plug should be easily reached.
4. A breakershouldbeincorporatedintofixedwiring.Thebreakershouldbe
all-pole
switch.
Power cable:
Power cable:
2wire with ground 14AWG
2wire with ground 14AWG
type of
Ensure that on dirt or debris enters the pipe.
The standard pipe length is 7m(27 9/16). If it is over 7m(27 9/16), the function of
theunitwillbe
be charged,
be conducted
perform air
refrigerant,
affected. If the pipe has to be lengthened, the refrigerant should
accordin
g
to 50 g/m(0.045 oz/inch).
by professional
purging from the refrigerant pipes and indoor unit using a vacuum
pump,then
air conditioner servicer. Before adding additional
charge additional refrigerant.
But the ch
arge of refrigerant must
CAUTION
Outdoor unit
Indoor unit
B
A
Outdoor unit
Max.Elevation: Amax=15 m
●
Outdoor unit
Oil trap
B
A
Connection
ƽ
Take off the panel(top), by removing the 5 screws.
Remove the plugs on the conduit plate.
ƽ
Temporarily mount the conduit tubes on the conduit plate.
ƽ
Connect both the power supply and unit wire harness to
ƽ
Indoor unit
In case the elevation A is more●
than 5m, oil trap shoud be
installed every 5~7m
Max. Length: Bmax=
Incasethepipelength B is●
more than 10m, the refrigerant
should be charged, according
to 50 g/m.
B
Indoor unit
A
5m●
the corresponding terminals on the terminal board.
Ground the unit in accordance with local codes.
ƽ
Allow several extra inches of wire for making wiring
ƽ
connections.
ƽ
Use lock nuts to secure conduit tubes.
Outdoor unit
Installation of Outdoor Unit
Install according to Drawing for the installation of indoor and
Connection of pipes
To bend a pipe, be careful not to crush the pipe,
ƽ
and the bending radius should be 30(1 1/6) to 40
Connecting the pipe of gas side first makes working easier.
ƽ
TheconnectionpipeisspecializedforR410A.ƽ
Half union
Spanner
Flare nut
Torque wrench
Forced fastening without careful centering may
damage the threads and cause a leakage of gas.
Pipe Diameter(ǿ)Fastening torque
Liquid side6.35mm(1/4")18N.m
Liquid/Gas side9.52mm(3/8")42 N.m
Gas side 12.7mm(1/2")55N.m
Gas side 15.88mm(5/8")60 N.m
mm(1 4/7) or longer.
outdoor units
Attaching Drain-Elbow
If the drain-elbow is used,ƽ
please attach it as figure. (Note:
Onlyforheatpumpunit.)
Purging Method:To use vacuum pump
Detach the service port’s cap of
1.
and3-way’s,connecttheserviceportintothe
for gaugemanifold.
gemanifold into vacuum pump.
Open the handle at Iow in
2.
moves of gause (Iow) reach vacuum condition in a moment, check 1. again.
Vacuum for over 15min. And check the gauge which should read -0.1MPa
3.
(76 cm Hg) at Iow
handle ‘Lo’ in gaugemanifold and stop the operation of the vacuum pump. Check
condition of the scale and hold it for 1-2min. If the scale-moves back in spite of
tightening, make flaring work again, the return to the beginning of 3 .
Open the valve rod for the 2-way valve counterclockwise to 90 degrees.4.
After 6 seconds, close the
Then connect the projection of charge hose (center) for gau-
pressure side. After the
3-way valve, the valve rod’s cap for 2-way valve
gaugemanifold, operate vacuum pump. If the scale-
2-way valve and make the
projection of charge hose (Iow)
completion of vacuuming, close the
inspection of gas leakage.
3
5.
No gas leakage?
In case of gas leakage, tighten parts of pipe connection. If
then proceed
leakage check and flare tubes again. Repeat vacuum and leak and if no
leakage, proceed to step 6.
step 6. If leak continues, remove the refrigerant used for the
high pressure in the system casuing damage and possibly personal injuries.
Power Source Installation
ƽ
The power source must be exclusively used for air
In the case of installing an air conditioner in a moist place,
ƽ
rth leakage breaker (GFCI).
ƽ
For installation in other places, use a circuit breaker as far
CuttingandFlaringWorkofPiping
Pipecuttingiscarriedoutwith a pipecutterandbursmust
ƽ
Afterinsertingtheflarenut,flaring workiscarriedout.
ƽ
FlaretoolforR410AConventionalflaretool
Clutch-typeclutch-type(Rigid-type) Wing-nut type (Imperial-type)
0~0.5mm
A
0~1/51 inch
Flare tooling die
charge the liquid refrigerant into air conditioner
conditioner. (Over I0A)
please install an ea-
as possible.
be removed.
1.0~1.5mm
3/76 ~1/17 inch
1.Cut pipe
3.Inserttheflarenut
1.5~2.0mm
1/17 ~1/8 inch
2.Remove burs
4.Flare pipe
Less than
5cm
ay
l
y.
It becomes
high midway.
Pleasepourwaterinthedrainpan of theindoorunit,and
ƽ
is carried out surely to outdoor.
In case that the attached drain hose is in a room, please
ƽ
it without fail.
The end is immersed in water.
It waves.
The gap with the
ground is too small
Thereisthebad
smell from a ditch
confirm that drainage
applyheatinsulationto
Refrigerant charge labelƵ
Contains fluorinated greenhouse gases
covered by the Kyoto Protocol
R410A
2
1=
2=
1
1+2=
FE
kg
kg
kg
A
B
C
D
This product contains fluorinated greenhouse gases covered by
the Kyoto Protocol. Do not vent into the atmosphere.
Refrigerant type:R410A
GWP* value:1975
GWP=global warming potential
Please fill in with indelible ink,
• 1 the factory refrigerant charge of the product
• 2 the additional refrigerant amount charged in the field and
• 1+2 the total refrigerant charge
on the refrigerant charge label supplied with the product.
The filled out label must be adhered in the proximity of the product
charging port (e.g. onto the inside of the stop valve cover).
A contains fluorinated greenhouse gases covered by the Kyoto
Protocol
B factory refrigerant charge of the product: see unit name plate
C additional refrigerant amount charged in the field
D total refrigerant charge
E outdoor unit
F refrigerant cylinder and manifold for charging
Check for Installation and Test Run
Ƶ
Pleasekindlyexplaintoourcustomershowtooperate
Ƶ
through the instruction manual.
CheckItemsforTestRun
Put check mark
Gasleakfrompipeconnecting?
Heat insulation of pipe connecting?
Are the connecting wirings of indoor and outdoor firmly
inserted to the terminal block?
Is the connecting wiring of indoor and outdoor firmly fixed?
Is drainage securely carried out?
Is the earth line securely connected?
Is the indoor unit securely fixed?
Is power source voltage abided by the code?
Is there any noise?
Isthelampnormallylighting?
Are cooling and heating (when in heat pump) performed normally?
Is the operation of room temperature regulator normal?
in boxes
CorrectIncorrect
Lean
Damage of flare CrackPartial Too outside
4