Please read this operation manual before using the air conditioner.
Keep this operation manual for future reference.
0010532977
Parts and Functions
Indoor Unit
Inlet
Inlet grille
Outlet
Negative Anion
generator
Horizontal flap
(adjust up and down air flow
Don’t adjust it manually)
(inside)
Intelligent
eye
Please be subject to the actual produce
purchased, the above picture is just from
your reference.
Display board
Signal receiver hole
iFP display
HEALTH display
(If the unit which you
purchased has healthy
function,follow it.
If not,please ignore.)
TIMER OFF display
TIMER ON display
SLEEP display
temp display
Temp display include two
displaying types.
Air Purifying Filter
(inside)
Vertical blade
(adjust left and
right air flow)
One is ambient temp
displaying ,the other
is set temp displaying.
The displaying temp can
be changed between
ambient temp and set
temp by some special
operation.
SMART display
COOL display
DRY display
HEAT display
Emergency
Switch
Display
board
Outdoor Unit
OUTLET
INLET
Remote controller
Outer side of the controller
SMARTCOOLHEAT
FANDRYCTD
POWERSOFT
ECO
iFP
SMARTON/OFF
COOL
HEAT
DRY
2
ECONOMYFAN SPEED
iFP
1.iFP button
Induce the movement of the
human body,so as to control
the airflow / energy saving
functioning.
2.ECONOMY button
Used to set ECONOMY
operation.
3.DRY button
Used to set DRY operation.
SETTEMP.
AUTOAUTO
FANSPEED
TIMER ONOFF
AMPM
ROOMTEMP.
AUTO
FOLLOW
EVADE
4
CONNECTING PIPING
AND ELECTRICAL WIRING
DRAIN HOSE
4.HEAT button
Used to set HEAT operation.
(Cooling only unit do not
have displays and functions
11
related with heating.)
5.COOL button
12
Used to set COOL operation.
6.SMART button
Used to set SMART operation.
13
(This function is unavailable
on some models.)
7.Display of each function
14
status
8.Operation mode display
9.Signal sending end
10.Signal sending display
15
11.TEMP display
12.FAN SPEED display
Swing up/down display
Left/right air flow display
16
13.TIMER ON display
17
TIMER OFF display
CLOCK display
14.ON / OFF button
15.TEMP. button
16.FAN SPEED button
Used to select fan speed:
LOW,MED,HI,AUTO
17.FOLLOW / EVADE button
Detect the location where
the human body is, adjust
the air deflector to blow/avoid
the body.
2
Operation
Inner side of the controller
SMART
SET TEMP.
AUTOAUTO
FAN
SPEED
TIMER ON OFF
AM
PM
ROOM TEMP.
AUTO
COOL
HEAT
FAN
DRY
CTD
POWER
SOFT
ECO
iFP
26
25
24
23
22
21
20
19
18
SMART
18.CODE button
Used to select CODE A or B
with a press, A or B will be
displayed on LCD.Please
select A without special
explanation.
19.RESET button
When the remote controller
appears abnormal,use a
sharp pointed article to
press this button to reset
the controller normal.
20.INQUIRE button
Inquire the external
environmental temperature
and the operating power of
the machine. (e.g. when the
panel display
“01”, the
This function unavailable on this models.
Loading of the battery
o
perating power is 100W;
when the panel display
the operating power
2
and so forth)
00W,
is
21.LIGHT button
Control the lightening and
extinguishing of the indoor
LED display board.
The manual of how to change
the default display temp
Press LIGHT button continuously
27
for ten times, the display temp on
display panel can be changed
28
between ambient temp and set
temp.
29
30
22.POWER / SOFT button
ć
23.
10
31
special heating set function:
10 degree heating maintaining
32
(valuable for RS)
24.HEALTH AIRFLOW
33
button
34
25.HEALTH button
26.SWING UP/DOWN
button
27.SWING LEFT/RIGHT
button
28.FRESH button
29.SLEEP button
30.TIMER ON / OFF button
31.HOUR button
32.CANCEL/CONFIRM
button
Used to confirm timer and
clock settings.
33.CLOCK button
34.LOCK button
If pressed, the other buttons
will be disabled. Press it once
again,lock will be cancelled.
“02”,
2
Load the batteries as illustrated. 2 R-03
batteries,resetting key(cylinder); Be sure
that the loading is in line with the" + "/"-";
3
Load the battery,then put on the cover
again.
Clock set
Press CLOCK button,
1
"AM" or "PM" flashes.
Press “+” or “-” to set
2
correct time.
AM
PM
SMART
Note:
The distance between the signal transmission head and the
receiver hole should be within 7m without any obstacle as well.
When electronic-started type fluorescent lamp or change-over
wireless telephone is installed in the type fluorescent lamp or
room, the receiver is apt to be disturbed in receivingthe signals,
so the distance to the indoor unit should be shorter.
Full display or unclear display during operation indicates the
batteries have been used up.Please change batteries.
If the remote controller can’t run normally during operation,
please remove the batteries and reload several minutes later.
Each press will increase or
decrease 1min.If the button
is kept pressed,time will
change quickly.
Remove the batteries in case unit won’t be in usage for a
long period.If there are any display after taking-out,just need
to press reset key.
3
Operation
SMART Operation
(This function is unavailable on
SMART
AM
SMART
some models)
One key can give you a comfortable
room!
The air conditioning unit can judge
the indoor temperature and humidity,
and make the adjustment accordingly.
SMART
Press ON/OFF button, unit starts.
Press SMART button“ ” is
displayed on the remote controller
and “ ” is displayed on the
display board,unit will run in SMART
SMART start
SMART
COOL,HEAT and DRY Operation
Unit start.
the remote controller
SMART
AM
1
Select operation mode.
2
Press COOL button“ ” is
displayed on
and “ ” is displayed on the
display board,unit will run in
COOL mode.
mode.
ƽ
SMART FRESH
ƽ
SMART Defrost
ƽ
SMART FAN SPEED
ƽ
SMART FAN HEALTH
ƽ
SMART DRY
ƽ
SMART SOFT
ƽ
SMART Control temperature
SMART
SMART stopsor
Under the cooling, heating and dehumidifying mode,
press the smart key to enter the smart function.
Under the smart running mode, when the air
conditioning is running, it will automatically select
cooling, heating, dehumidifying or blowing mode as
per the setting temperature.
When the smart function is running, press the “cooling”
“heating” or “dehumidifying” key to switch to the other
mode, you will exit from the smart function.
Press HEAT button“ ” is displayed on the remote
controller and “ ” is displayed on the display board,
unit will run in HEAT mode.
Press DRY button“ ” is displayed on the remote
controller and “ ” is displayed on the display board,
unit will run in DRY mode.
1.In DRY mode, when room temperature becomes lower
than temp.setting+2 unit will run intermittently ai
o
C,
LOW speed regardless of FAN setting.
2.Remote controller can memorize each operation status.
When starting it next time, just press ON/OFF button
and unit will run in previous status.
Loading...