Haier HSU-18LH03 user guide manual

SPLIT TYPE ROOM AIR CONDITIONER
OPERATION MANUAL
HSU-07LEK03 HSU-09LEK03 HSU-12LEK03 HSU-09LEK13 HSU-12LEK13 HSU-07HEK03 HSU-09HEK03 HSU-12HEK03 HSU-18LEK13 HSU-24LEK13 HSU-12LEK13-M HSU-18HEK03 HSU-24HEK03 HSU-09LEK03-Y3 HSU-12LEK03-Y3 HSU-18LEK03-Y3 HSU-24LEK03-Y3
HSU-09LEK03-Y5 HSU-12LEK03-Y5 HSU-18LEK03-Y5 HSU-24LEK03-Y5
HSU-09CK2S3 HSU-12CK2S3 HSU-18LK2S3 HSU-24LK2S3 HSU-09CK2W3 HSU-09CK6B3 HSU-12CK2W3 HSU-12CK6B3
HSU-18LK2W3 HSU-18LK6B3 SAS-09HEK3 SAS-12HEK3 SAS-18HEK3 SAS-24HEK3
HSU-09LH03 HSU-12LH03 HSU-18LH03 HSU-24LH03 HSU-09HH03 HSU-12HH03 HSU-18HH03 HSU-24HH03 HSU-09HEG03 HSU-12HEG03 HSU-18HEG03 HSU-24HEG03
HSU-18LEK03-Y2 HSU-12LEK03-Y2 HSU-24LEK03-Y2 HSU-09LEK03-Y2 YKS-18HEK03 YKS-24HEK03 HSU-18LEK03
HSU-12LEK03-Y6 HSU-18LEK03-Y6
HSU-24LEK03-Y6 HSU-09LEK03-Y6
HSU-09LEK03-Y4 HSU-12LEK03-Y4 HSU-18LEK03-Y4 HSU-24LEK03-Y4 HSU-12CK6B2 HSU-18LK2W3 HSU-18LK6B2 HSU-24LK2S2 HSU-24LEK03 HSU-18LEK03EK1 HSU-26HEK03
Contents
PARTS AND FUNCTIONS
OPERATION
MAINTENANCE
CAUTIONS
TROUBLE SHOOTING
1 2-4
5
Please read this operation manual before using the air conditioner.
Keep this operation manual for future reference.
0010518786
Parts and Functions
TIMER
CLOCK
SET
SLEEP
Indoor Unit
1
2
3
4
5
5
6
1
1
Inlet
2
2
Inlet grille
4
5
Anion generator
6
6
Vertical blade
adjust left and right air flow
7
Power indicator
Timer mode indicator
8
(Lights up whenTimer operation is selected.)
9
Operation mode indicator
(lights up when the compressor is on.)
10
Remote signal receiver
(A beeping sound is generated when a signal from remote controller isreceived.)
11
Ambient temp display
When receiving the remote control signal, display the set temperature and in the rest time the room temperature is displayed and this room temperature is only for reference.
Horizontal flap
12
adjust up and down air flow Don't adjust it manually
3
3
Air Purifying Filter (inside)
5
4
Outlet
(inside)
(Lights up when unit starts.)
Actual inlet grille may vary from the one shown in the manual according to the product purchased
7
8
9
10 11
12
Remote controller
1
2
5
3
23
13
18
12
21
19
17
1. Mode display
HEALTH
TIMER
CLOCK
SET
LOCK
ON/OFF
FAN
MODE
SWING
SLEEP
RESET
AUTO COOL DRY HEAT
2. SWING display
3. FAN SPEED display
4. SLEEP display
5. LOCK display
NOTE:
Cooling only unit do not have displays and functions related with heating
If the unit which you purchased has healthy function,follow it.If not,please ignore.
FAN
LO MED HIAUTO
10
6. SIGNAL SENDING
6
7. TIMER OFF display
7
8. TIMER ON display
8
9. CLOCK display
9
10. TEMP display
4
11. POWER ON/OFF
11
15
20
14
16
22
Used for unit start and stop.
12. MODE Used to select AUTO run, COOL, DRY,HEAT and FAN operation.
13. FAN Used to select fan speed LO,
MED, HI, AUTO
14. HOUR
Used to set clock and timer setting.
15. SWING
Used to set auto fan direction.
16. SLEEP
Used to select sleep mode.
17. LOCK
Used to lock buttons and LCD display.
18. TEMP.SETTING
Used to select your desired temp.
19. SET / Used to confirm timer and clock settings.
20. TIMER Used to select TIMER ON, TIMER OFF,TIMER ON-OFF
21. CLOCK
22. RESET Used to reset the controller back
to normal condition.
23. HEALTH Used to operate the healthy function and LCD display.
unacailable on some models.)
LIGHT
Used to set correct time
(This function is
Outdoor Unit
OUTLET
INLET
Clock set
Press CLOCK button, "AM" or "PM" flashes. Press or to set correct time. Each press
or decrease 1min. If the
change quickly.
"AM "and "PM" stop flashing,while clock starts working.
After time setting is confirmed,press SET,
CONNECTING PIPING AND ELECTRICAL WIRING
DRAIN HOSE
14
will increase
button is kept pressed,time will
Loading of the battery
Remove the battery cover;
1
2
3
Load the battery,then put on the cover again.
4
Note:
The distance between the signal transmission head and the receiver hole should be within 7m without any obstacle as well.
When electronic-started type fluorescent lamp or change-over wireless telephone is installed in the type fluorescent lamp or room, the receiver is apt to be disturbed in receivingthe signals, so the distance to the indoor unit should be shorter.
Full display or unclear display during operation indicates the
ries have been used up.
batte
If the remote controller can't run normally during operation,
remove the batteries and
please
Hint:
Remove the batteries in case unit won't be in usage for a long period.
If there are any display
Load the batteries as
2
illustrated. 2 R-03 batteries,
1
resetting key(cylinder);
Be sure that the loading
3
is in line with th
Please change batteries.
reload several minutes later.
after taking-out, just need to press reset key
e" + "/"-";
1
Operation
Unit start / stop
Press ON/OFF button, unit starts or stops.
HEALTH
ON/OFF
FAN
Operation Mode
AUTO
COOL
DRY
HEAT
FAN
Select temp.setting
Remote
Controller
Under the mode of auto operation, air conditioner will automatically select Cool or Heat operation according to room temperature.
air conditioner
according to room
In DRY mode, when room temperature becomes lower than temp.setting+2 at LOW speed regardless of FAN setting.
In FAN operation mode, the unit will not operate in COOL or HEAT mode but only in FAN mode ,AUTO is not available in FAN mode.And temp.setting is disabled. In FAN mode,SLEEP operation is not available.
automatically adjusts the fan speed
Note
When FAN is set to AUTO, the
temperature.
FAN
MODE
SWING
o
C,unit will run intermittently
Auto Operation
According to the automatic choice system in temperature in indoors
cold or make the hot movement
Dry Operation
FAN
MODE
SWING
FAN
MODE
SWING
Cool Operation
FAN
MODE
SWING
Heat Operation
Note:
In DRY mode, when room temperature becomes lower than temp.
setting+2 C, unit will run intermittently at LOW speed regardless
of FAN setting.
o
Fan Operation
1.
When FAN is set to AUTO,
the air conditioner
automatically adjusts the fan speed according
temperature.
to room
2.In FAN operation mode the unit will not operate
in COOL mode but only
AUTO LO MED HI
HEALTH
ON/OFF
FAN
MODE
in FAN mode ,AUTO is not available in FAN mode.And temp.setting is disabled.
Air Flow Direction Adjustm
(1)
FAN
FAN
MODE
SWING
Note:
In HEAT mode,warm air will blow out after a short periodof the time
due to cold-draft prevention function.
When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.
Cooling only unit do not have displays and functions related with heating
MODE
SWING
Remote controller can memorize each operation status. When starting it next time,just press ON/OFF button and unit will run in previous status.
2
3
ON/OFF
HEALTH
FAN
Healthy Negative ions
To cancel TIMER mode
Just press TIMER button several times untilTIMER mode disappears.
The anio n generato r in the ai rcon ditione r can
generate a lot of
the air an d
also to ki ll ba cteria and sp eed u p the dust sedim ent
anion effectivel y balance th e
quantity of p ositi on and an ion i n
in the ro om an d finall y clean th e air in the room.
Operation
(1)
TIMER ON
TIMER
CLOCK
SET
SLEEP
TIMER
CLOCK
SET
SLEEP
TIMER
CLOCK
SET
SLEEP
TIMER
CLOCK
SET
SLEEP
TIMER
CLOCK
SET
SLEEP
You can let unit start or stop automatically a following times:
Before you wake up in the morning, or get back from outside
Set Clock correctly before starting Timer operation
(3)
TIMER Operation
TIMER ON-OFF
TIMER
CLOCK
SET
SLEEP
TIMER
CLOCK
SET
SLEEP
TIMER
CLOCK
SET
SLEEP
TIMER
CLOCK
SET
SLEEP
or after you fall asleep at night.
Emergency Operation:
temperature is below 16
o
C, do not use it in the
Test operation:
Use this switch in the test operation when the room
normal operation.
your finger from the switch: the cooling
Continue to press the test operation switch for more than 5 seconds. After
you hear the "Pi" sound twice,
release
Test operation switch is the same as emergency switch.
operation starts with the air flow speed "Hi".
Emergency operation and test operation
Use this operation only when the remote controller is defective or lost.
When the emergency operation switch is pressed,the" Pi "sound is heard once, which means the start of this operation.
In this operation, the system automatically selects the operation modes,cooling or fan or heat,according to the room temperature.
It is not possible to operate in dry mode.
Room temperature
Operation mode
Designated temperature
Timer mode
Air flow
ABOVE 23
O
C
BELOW 23
O
C
COOLING
HEAT
23
O
C
26
O
C
NO
NO
AUTOMATIC
AUTOMATIC
Pi
(Cooling only uint
Room temperature
Operation mode
Designated temperature
Timer mode
Air flow
BELOW 23
O
C
FAN
26
O
C
NO
AUTOMATIC
Pi Pi
HEALTH Operation
(This function is unavailable on some models.)
TIMER
CLOCK
SET
SLEEP
(2)
TIMER OFF
TIMER
CLOCK
SET
SLEEP
Operation
Comfortable SLEEP
Before going to bed,you can simply press the SLEEP
button
you a sound sleep.
and unit will operate in SLEEP mode and bring
SLEEP Operation
In HEAT mode
2.
1 hours after SLEEP mode starts, temp will
O
become 2 another 1 hours, temp decrease by 2 C
C lower than temp.setting. After
O
further. After more another 3 hours, temp. rises by 1 C further. The unit will run for
O
further 3 hours then stops. Temp. is lower than
p. setting so that room temperature
tem
won't be too high for your sleep.
Temp.setting
1 hr
Decreases 2
1 hr
Decreases 2
Unit stop
O
C
O
C
3 hrs
3 hrs
SLEEP
operation starts
Rises 1OC
SLEEP
operation stops
In HEAT mode
Operation Mode
1. In COOL,DRY mode
1 hours after SLEEP mode starts, temp. will
O
become 1 another 1 hours, temp. rises by 1
The unit will run for further 6 hours then stops Temp. is higher than temp. setting so that room
temperature won't be too Iow for your sleep.
SLEEP operation starts
Temp.setting
C higher than temp. setting. After
O
C further.
SLEEP operation stops
ox.6hrs
Appr
O
C
1 hr
1 hr
Rises1
Rises 1
O
C
Unit stop
In COOL, DRY mode
3.In AUTO mode
The unit operates in corresponding sleep mode
corresponding sleep mode adapted to the automatically selected operation mode.
4. In FAN mode
It has no SLEEP function.
5.
When quiet sleeping function is set to 8 hours
the quiet sleeping time can not be adjusted.When
TIMER function is set,the quiet sleeping function
can't be set up.After the sleeping function is set
up,if user resets TIMER function, the sleeping
function will be cancelled; the machine will be in
the state of timing-on,if the two at the same time,
either of their operation time is
modes are set up
ended first ,the unit will stop automatically,and the other mode will be cancelled.
Power Failure Resume Function
If the unit is started for the first time, the compressor will not start running unless 3 minutes have elapsed. When the power resumes after power failure, the unit will run automatically,
and 3 minutes later the compressor starts running.
Note to the power failure resume:
press the sleep button ten times in five seconds and enter
function after hearing four sounds.And press the sleep button ten times within five seconds and leave this function after
hearing two sounds.
4
Maintenance
For Smart Use of The Air Conditioner
Setting of proper room temperature
Proper temperature
Close doors and windows during operation
During cooling operation prevent the penetration of direct sunlight with curtain or blind
If the unit is not to be used for a long time, turn off the power supply main switch.
OFF
Do not block the air inlet or outlet
Use the timer effectively
Use the louvers effectively
Remote Controller
Do not use water ,wipe the controller with a dry cloth.Do not use glass cleaner or chemical cloth.
Do not use the following for cleaning
Gasoline,benzine, thinner or cleanser may damage the coating of the unit.
Air Filter cleaning
Open the inlet grille by pulling it upward.
Remove the filter.
Push up the filter's center tab slightly until it is released from the stopper, and remove the filter downward.
Clean the filter.
Use a vacuum cleaner to remove dust, or wash the filter with water.After washing, dry the filter completely in the shade.
Attach the filter.
Attach the filter correctly so that the "FRONT" indication is facing to the front.Make sure that the filter is completely fixed behind the stopper.If the right and left filters are not attached correctly, that may cause defects.
Close the inlet grille.
Indoor Body
Wipe the air conditioner by using a soft and dry cloth.For serious stains,use a neutral detergent diluted with water.Wring the water out of the cloth before wiping.then wipe off the detergent completely.
O
Hot water over 40 discoloring or deformation.
C(104OF) may cause
Once every two weeks
Replacement of Air Purifying Filter
1.Open the lnlet Grille
Prop up the inlet grille by using a
small device named grille-support
which located in the right side of the indoor unit.
2.Detach the standard air filter
Slide the knob slightly upward to release the filter, then withdraw it.
Detach old Air Purifying Filter
3.Attach Air Purifying Filter
Put air purifying filter appliances into the right and left filter frames.
(NOTE: Air purifying filter is optional part)
4.Attach the standard air filter
(Necessary installation)
ATTENTION: The white side of the photocatalyst air purifying
filter face outside,
The green side of the bacteria-killing medium air
purifying filter face outside,
5.Close the Inlet Grille
Close the Grille surely
NOTE:
The photocatalyst air purifying filter will be solarized in fixed time. In normal family,
The bacteria-killing medium air purifying filter will be used for a long time,no need for replacement. But in the period of using them ,you should remove the dust frequently by
using vacuum cleaner or flaping them lightly,otherwise ,
its performance will be affected.
and the black side face the unit.
and the white side face the unit.
it will be solarized every 6 months.
Please keep the bacteria-killing medium air purifying filter in the cool and dry conditions when you stop using it,or its ability of sterilization will
avoid long time directly sunshine
be
reduced.
5
Cautions
WARNING
Please call Sales/Service Shop for the Installation. Do not attempt to install the air conditioner by yourself because improper works
may cause electric shock, fire, water leakage.
WARNING
When abnormality such as burnt-small found, immediately stop the operation button and contact sales shop.
Use an exclusive power source with a circuit breaker
Check proper installation of the drainage securely
OFF
Connect power supply cord to the outlet completely
STRICT
ENFORCEMENT Do not use power supply cord in a bundle.
PROHIBITION
Do not start or stop the operation by disconnecting the power supply cord and so on.
PROHIBITION
STRICT
ENFORCEMENT
Use the proper voltage
STRICT
ENFORCEMENT
Take care not to damage
the power supply cord.
PROHIBITION
Do not channel the air flow directly at people, especially at infants or the aged.
PROHIBITION
STRICT ENFORCEMENT
1.Do not use power supply cord extended or connected in halfway
2.
Do not install in the place where there is any
possibility of inflammable gas leakage around the unit.
3.Do not get the unit exposed
to vapor or oil steam.
PROHIBITION
Do not insert objects into the air inlet or outlet.
PROHIBITION
Do not try to repair or reconstruct by yourself.
Connect the earth cable.
earthing
Do not use for the purpose of storage of food, art work, precise equipment, breeding, or cultivation.
PROHIBITION
Do not install the unit near a fireplace or other heating apparatus.
PROHIBITION
Do not place animals or plants in the direct path of the air flow
PROHIBITION
CAUTION
Take fresh air occasionally especially when gas appliance is running at the same time.
STRICT
ENFORCEMENT
Check good condition of the installation stand
PROHIBITION
Do not place any objects on or climb on the unit.
PROHIBITION
Do not operate the switch with wet hand.
PROHIBITION
Do not pour water onto the unit for cleaning
PROHIBITION
Do not place flower vase or water containers on the top of the unit.
PROHIBITION
6
Trouble shooting
7
Before asking for service, check the following first.
Normal Performance inspection
Noise is heard
Phenomenon
Cause or check points
The system does not restart immediately.
Smells are generated.
Mist or steam are blown out.
Multiple
check
Poor cooling
Application temp. range of air conditioner -7
o
C~43oC.
When unit is stopped, it won't restart
elapsed to protect the system. When the electric plug is pulled out
and reinserted, the protection circuit
During unit operation or at stop, a swishing or gurgling noise may
(This noise is generated by refrigerant flowing in the system.)
During unit operation, a cracking noise may be heard.This noise is
temperature changes. Should there be a big noise from
filter may be too dirty.
This is because the system circulates smells from the interior
During COOL or DRY operation,
This is due to the sudden cooling
Is power plug inserted? Is there a power failure? Is fuse blownout?
Is the air filter dirty?
Are there any obstacles before
Is temperature set correctly? Are there some doors or
Is there any direct sunlight through the window during the
Are there too much heat sources or too many people in the room
In dry mode,
fan
speed can’t be changed.
In DRY mode, when room
than temp.setting+2
o
C,unit will
regardless of FAN setting.
Maximum: D.B
10.The appliance must be installed on a strong enough support.
9.Young children should be supervised ensure that they do not play with the appliance.
8.The appliance is not intended to use by young children or infirm
persons without supervision.
7.The used batteries should be disposed of properly.
6.
After installation, the power plug should be easily reached..
5.The wiring method should be in line with the local wiring standard.
4.The distance between the indoor unit and the floor should be more than 2m.
3. If the fuse on PC board is broken please change it with a fuse
type T. 3.15A/250V.
11.The wiring diagram is attached inside the machine.
2. If the supply cord is damaged, it must be replaced by the
manufacturer or its service agent or a similar qualified
person.
The type of connecting wire is H05RN-F or H07RN-F
Cautions
The machine is adaptive in following situation
1.Applicable ambient temperature range:
Cooling
Heating
Indoor
Outdoor
Outdoor
Indoor
Maximum: D.B / W.B 32
o
C/23
o
C
18
o
C/14
o
C
43
o
C/26
o
C
18
o
C
27
o
C
15
o
C
24
o
C/18
o
C
-7
o
C/-8
o
C
Minimum: D.B / W.B
Minimum: D.B Maximum: D.B Minimum: D.B Maximum: D.B / W.B Minimum: D.B / W.B
For: T3
Cooling
Heating
Indoor
Outdoor
Indoor
Outdoor
Maximum: D.B / W.B Minimum: D.B / W.B
Maximum: D.B / W.B Minimum: D.B
Maximum: D.B Minimum: D.B
Maximum: D.B / W.B Minimum: D.B / W.B
29oC/19oC 18
o
C/14oC
54
o
C/24oC
18
o
C
27
o
C
15
o
C
24
o
C/18oC
-7
o
C/-8oC
For: T1
during cooling operation?
cooling operation?(Use curtain)
windows left open?
inlet and outlet?
Normally it should be cleaned every 15 days.
run intermittently at LOW speed
temperature becomeslower
indoor unit may blow out mist.
of indoor air.
air such as the smell of furniture, paint, cigarettes.
air flow in unit operation, air
generated by the casing expanding
or shrinking because of
be heard.At first 2-3 minutes after
unit start, this noise is more noticeable.
will work for 3 minutes to protect the
air conditioner.
immediately until 3 minutes have
If the fuse of outdoor unit on PC board is broken, please change it with the type of T. 25A/250V.
Application temp. range of air conditioner -7
o
C~54oC.
T1: T3: