Haier HSU-09LEK13/R2, HSU-24LEK13/R2, HSU-12LEK13/R2, HSU-18LEK13/R2, HSU-18LEK13/R2-B3 Operation Manuals

...
Please read this operation manual before using the air conditioner. Keep this operation manual for future reference.
SPLITTYPEROOMAIRCONDITIONER OPERATION MANUAL
HSU-09LEK13/R2 HSU-12LEK13/R2 HSU-18LEK13/R2 HSU-24LEK13/R2 HSU-12LEK13/R2-B3 HSU-18LEK13/R2-B3
0010584050
Contents
PARTS AND FUNCTIONS OPERATION MAINTENANCE CAUTIONS TROUBLE SHOOTING
13
8 9
12
14
Índice
PRECAUCIONES
COMPONENTES Y FUNCIONES FUNCIONAMIENTO MANTENIMIENTO
RESOLUCIÓN DE PROBLEMAS
Outdoor Unit
OUTLET
INLET
CONNECTING PIPING AND ELECTRICAL WIRING
DRAIN HOSE
4
Actual inlet grille may vary from the one shown in the manual according to the product purchased
Parts and Functions
Indoor Unit
Remote controller
10.
12.
SWING LEFT/RIGHT button
13.
15. SLEEP button
14. HEALTH button
16.
18. POWER/SOFT button
20. TEMP button
21. TIME OFF/ON
22.
1. Mode display
1 2
3 4 5
15 16
HEALTH
SLEEP
TIME OFF
TIME ON
/QUIET
9
10 11
12 13
14
17
8
22 23 24
25
19 20
21
18
7
6
SWING
Operation mode
AUTO
FAN
COOL DRY
Remote controller
2. Signal sending display
4.FAN SPEED display
5. LOCK display
6. TIMER OFF display TIMER ON display
7. TEMP display
3. SWING display
LO MED HI
AUTO
Display circulated
8.
Additional functions display
Operation mode
Remote controller
QUIET
TURBO
SLEEP
Supplemented electrical heating
HEALTH
9. TURBO/QUIET button FAN button
11. COOL button
FAN SPEED button
LOCK
button
Control the lightening and extinguishing of the indoor LED display board.
17. LIGHT button
19. DRY button
button
SWING UP/DOWN
button
23.HEALTH AIR FLOW
button
24.CANCEL/CONFIRM button Function: Setting and cancel to the
timer and other additional functions.
25. RESET button When the remote controller appears abnormal, use a sharp pointed article to press this button to reset the remote.
Healthy function is not available for some units.
Loading of the battery
1 2
3
4
Remove the battery cover;
Load the batteries as illustrated.
2 R-03 batteries, resetting key
(cylinder);
Be sure that the loading
is in line with th
e" + "/"-";
Load the battery,then put on the cover again.
The distance between the signal transmission head and the rece­iver hole should be within 7m without any obstacle as well.
When electronic-started type fluorescent lamp or change-over
wireless telephone is installed in the
ver is apt to be disturbed in receiving
the signals,
so the distance to the indoor unit should be shorter.
type fluorescent lamp or room, the recei
Note:
Full display or unclear display during operation indicates the
ries have been used up.
Please change batteries.
If the remote controller can't run normally during operation, please
reload several minutes later.
batte
remove the batteries and
TURBO
Display board
(adjust left and
ow)
Vertical blade
right air fl
Air Purifying Filter
Inlet
(inside)
Emergency
Switch
Horizontal flap
(adjust up and down air flow Don't adjust it manually)
Outlet
Inlet grille
Display board
1
4
2
3
5
Signal receiver hole
ON/OFF display
4
2 3
1
5
TIMER ON\OFF display SLEEP display
Ambient temp.display
When receiving the remote
control signal, display the set
displayed.
time the room temperature is
temperature and in the rest
Note to the power failure resume:
press the sleep button ten times in five seconds and enter function after hearing four sounds.And press the sleep button ten times within five seconds and leave this function after hearing
TIMER ON-OFF display
COOL\HEAT\Dry\AUTO display
two sounds.
1
Operation
Air Flow Direction Adjustment
Base Operation
Remote controller
Emergency operation and test operation
Emergency Operation:
Use this operation only when the remote controller is defective or lost, and with function of emergency running, air conditoner can run automatically for a while. When the emergency operation switch is pressed, the " Pi " sound is heard once, which means the start of this operation. When power switch is turning on for the first time and emergency operation starts, the unit will run automatically in the following modes:
It is impossible to change the settings of temp. and fan speed,It is also not possible to operate in timer or dry mode.
Pi
HEALTH
SLEEP
TIME OFF
TIME ON
TURBO
/QUIET
SWING
Press FAN button. For each press, fan speed
follows:
Remote controller:
Press
button
Every time the button is pressed, temp.setting increase 1
o
C,if kept depressed, it will increase
rapidly
Every time the button is pressed, temp.setting
decrease 1
o
C,if kept depressed, it will
decrease rapidly
Select a desired temperature.
4.Fan speed selection
3.Select temp.setting
Air conditioner is running under displayed fan speed. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.
1. Unit start
Press ON/OFF on the remote controller, unit starts.
2. Select operation mode
COOL button:Cooling mode FAN button: Faning mode DRY button: Dehumidify mode
Display
circulated
changes as
LOW
MED HI
AUTO
Remote
Controller
Note
In DRY mode, when room temperature becomes lower than temp.setting+2
o
C, unit will run intermittently at LOW
speed regardless of FAN setting.
Under the mode of auto operation, air conditioner will automatically select Cool or Heat operation according to
room temperature. When FAN is set to AUTO the air conditioner automatically adjusts the fan speed according to room temperature.
In FAN operation mode, the unit will not operate in COOL or
HEAT mode but only in
FAN mode, AUTO is not available in FAN mode. And temp. setting is disabled. In FAN mode, sleep operation is not available.
Operation
Mode
DRY
COOL
AUTO
FAN
temperature.
according to room
temperature is below 16
o
C, do not use it in the
Test operation:
Use this switch in the test operation when the room
normal operation.
your finger from the switch: the cooling
Continue to press the test operation
switch for more than 5 seconds. After
you hear the "Pi" sound twice,
release
Test operation switch is the same as emergency switch.
operation starts with the air flow speed "Hi".
Under this operation mode,the fan motor of indoor
unit will run in high speed.
Pi Pi
Room temperature
Designated temperature
Timer mode
Fan
speed
Operation
mode
Above 23oC 26oC AUTO COOL
No
When restart after remote turning off, the remote controller
When adjusting the flap by hand,turn off the unit.
When humidity is high,condensate water might occur It is advisable not to keep horizontal flap at downward
position for a long time in COOLor DRY
otherwise, condensate water might occur.
adjusted to left or at air outlet if all vertical louvers are right.
mode ,
controller will automatically memorize the previous set swing position.
Note:
Vertical flap
Pos.1
(Auto
swing)
1.Status display of air flow
2.Left and right air flow adjustment
Pos.1
Pos.2
Pos.3
Pos.4
Pos.5
Pos.6
For each press of button, remote controller displays as follows :
remote controller:
Cautions:
Initial state
Pos.2 No initial state disaplayed on remote controller, the
vertical flap will be fixed on the current position
2
Operation
Sleep Operation
If the wind speed is high or middle before setting for the sleep, set for lowing the wind speed after sleeping.
If it is low wind, no change.
4.Set the wind speed change when sleeping
Operation Mode
1. In COOL,DRY mode
SLEEP operation starts SLEEP operation stops
Approx.6hrs
1 hr
Rises 1
O
C
Rises 1
O
C
Temp.setting
Unit stop
In COOL, DRY mode
1 hr
2.
In AUTO mode
3. In FAN mode
It has no SLEEP function.
Note
When TIMER function is set, the sleeping function can’t be set up .After the sleeping function is set u
p
,
TIMER function, the sleeping function will be cancelled; the machine will be in the state of
timing-on.
TURBO/QUIET Operation
1 hours after SLEEP mode starts,temp.will become
higher than temp.setting.After another 1 hours,temp.rises
by 1 futher.The unit will run for further
6 hours then stops
T
emp. is higher than temp.setting so that room temperature
won’t be too low for your sleep.
The unit operaters in corresponding sleep mode adapted to the automatically selected operation
mode.
O
C
1
O
C
if user resets
Before going to bed,you can simply press the SLEEP button and unit will operate in SLEEP mode and bring you a sound sleep.
TURBO
/QUIET
TURBO
/QUIET
Press the
TURBO
/QUIET
cancel
TURBO
QUIET
When you need fast cool or fast dehumidification,you can choose the Turob function; when you sleep, read, you can choose Quiet function
bu on, you can switch the “Turbo” and “Quiet”
will swith as below
When running in Turbothe fan speed is the highest, when running in Quiet, the fan speed is super slow
HEALTH Operation
Nano-Aqua generator adopt two high voltage pole to ionize the water molecule into nanometer water ion,and release these ions to the air to kill the bacterium and refresh the air. as well as the nanometer water inon can be easily absorbed by skin,keeping moisture anytime.