Haier HSU-18LEG13(T3) user guide manual

SPLIT TYPE ROOM AIR CONDITIONER
OPERATION MANUAL
HSU-18LEG03(T3) HSU-18HEG03(T3) HSU-24LEG03(T3) HSU-24HEG03(T3) HSU-18LEG13(T3) HSU-18HEG13(T3) HSU-24LEG13(T3) HSU-24HEG13(T3) HSU-30HEG13(T3) HSU-30LEG13(T3)
HST-24HEG13(T3) HST-24LEG13(T3) HST-30LEG13(T3) HST-30HEG13(T3) HST-18LEG13(T3) HST-18HEG13(T3) HSU-12HEG13(T3) HSU-09HEG03 HSU-12HEG03 HSU-24HEG03
Contents
PARTS AND FUNCTIONS
OPERATION
MAINTENANCE
CAUTIONS
TROUBLE SHOOTING
1 2-4
5
HST-18LEG03(T3) HST-24LEG03(T3)
Please read this operation manual before using the air conditioner. Keep this operation manual for future reference.
0010539051
Parts and Functions
Indoor Unit
Inlet
Inlet grille
Outlet
Vertical blade
(adjust left and
Horizontal flap
(adjust up and down air flow
ight air fl
r
Don't adjust it manually)
Display board
1
Signal receiver hole
2
ON/OFF display
3
Ambient temp.display
When receiving the remote control signal, display the set temperature and in the rest time the room temperature is displayed.
1
4
Note to the power failure resume:
press the sleep button ten times in five seconds and enter function after hearing four sounds.And press the sleep button ten times within five seconds and leave this function after hearing
two sounds.
5
Actual inlet grille may vary from the one shown in the manual according to the product purchased
Loading of the battery
Remove the battery cover;
1
2
2 R-03 batteries, resetting key
(cylinder);
3
is in line with the
Load the battery,then put on the cover again.
4
Note:
The distance between the signal transmission head and the rece­iver hole should be within 7m without any obstacle as well.
When electronic-started type fluorescent lamp or change- over
type fluorescent lamp or room, the recei
ver is apt to be disturbed in receiving
so the distance to the indoor unit should be shorter.
Full display or unclear display during operation indicates the
ries have been used up.
batte
If the remote controller can't run normally during operation, please
remove the batteries and
Hint: Remove the batteries in case won't be in use for a long period. If there is any display after taking-out, just press reset key.
Outdoor Unit
1
wireless telephone is installed in the
Please change batteries.
reload several minutes later.
4
Air Purifying Filter
(inside)
Emergency
ow)
Switch
Display board
2
4
3
5
TIMER ON\OFF display TIMER ON-OFF display SLEEP display
COOL\HEAT\Dry\AUTO display
Load the batteries as illustrated.
Be sure that the loading
" + "/"-";
the signals,
OUTLET
INLET
CONNECTING PIPING AND ELECTRICAL WIRING
DRAIN HOSE
4
Remote controller
Remote controller A
1
2
3
4
5
9
10
11
12
13
14
15
16
17
1. Mode display
Operation mode
Remote controller
AUTO FANCOOL DRY
HEAT
2. Signal sending display
3. SWING display
4. FAN SPEED display
Display circulated
LO MED HI
AUTO
5. LOCK display
6. TIMER OFF display TIMER ON display
7.TEMP display
Remote controller B
1
2
3
4
5
9
10
11
12
13
14
15
16
17
HEAT
FAN
1. Mode display
Operation mode
Remote controller
AUTO FANCOOL DRY
HEAT
2. Signal sending display
3. SWING display
4. FAN SPEED display
Display circulated
LO MED HI
AUTO
5. LOCK display
6. TIMER OFF display
TIMER ON display
7.TEMP display
NOTE: Healthy function is not available for some units.
8
Additional functions display
.
6
Operation mode
Remote controller
7
9. TURBO button
QUIET
SLEEP
supplemental electrical heating
10. FAN button
11. COOL button
12. AUTO button
8
13. FAN SPEED button
14. TIMER button
18
15. SLEEP button
16. LOCK button
19
Used to lock buttons and LCD display.
20
17. LIGHT button
Control the lightening and extinguishing of the indoor LED display board.
21
18. POWER ON/OFF button
19. DRY button
22
20. TEMP button
21. SWING button
23
22. HOUR button
24
23. EXTRA FUNCTION button
25
Function: Health--- Healthy airflow position1--- Healthy airflow position 2
--- Restore the original flap position--­Right & left air airflow--- A-B yard---
Refresh air(
reserved function)--- QUIET
--- Fahrenheit/Celsius mode conversion
24.CANCEL/CONFIRM button
Function: Setting and cancel to the timer and other additional functions.
25. RESET button When the remote controller appears abnormal, use a sharp pointed article to press this button to reset the remote
8
Additional functions display
.
6
Operation mode
Remote controller
7
9. TURBO button
QUIET
SLEEP
Supplemented electrical heating
10. HEAT button
11. COOL button
12. AUTO button
8
13. FAN SPEED button
14. TIMER button
18
15. SLEEP button
16. LOCK button
19
Used to lock buttons and LCD display.
20
17. LIGHT button
Control the lightening and extinguishing of the indoor LED display board.
21
18. POWER ON/OFF button
19. DRY button
22
20. TEMP button
21. SWING button
23
22. HOUR button
24
23. EXTRA FUNCTION button
Function:
25
Healthy airflow
Health--- FAN---
position1---
--- Healthy airflow position 2--­Right & left air airflow--- A-B yard---
Low-Temperature Heating Operation Down to 10
--- Fahrenheit/Celsius mode conversion
reserved
24.CANCEL/CONFIRM button Function: Setting and cancel to the timer and other additional functions.
25. RESET button When the remote controller appears abnormal, use a sharp pointed article to press this button to reset the remote
HEALTH
HEALTH
function
TURBO
TURBO
)-- QUIET--- Refresh air(
Operation
Unit start / stop
Remote controller
2
1. Unit start
Press ON/OFF on the remote controller, unit starts.
2.Select temp.setting
Press
/
Every time the button is pressed, temp.setting increase 1 rapidly
Every time the button is pressed, temp.setting decrease 1 decrease rapidly
Select a desired temperature.
button
o
C,if kept depressed, it will increase
o
C,if kept depressed, it will
1
3
2
Air Flow Direction Adjustment
1.Status display of air flow
Press button to enter additional options, when cycle display to , will flash. And then press
enter to up and down air flow function.
Press button. For each press,changes as follows:
Remote controller:
COOL/DRY:
HEAT:
Initial state
2.Left and right air flow adjustment
(This function is unavailable on some models.)
Press button to enter additional options, when cycle display to , will flash. And then press
enter to Left and right air flow function.
Press button. For each press,changes as follows:
Remote controller:
COOL/DRY/HEAT:
3.Fan function
Remote controller A:
Remote controller B:
Press button to enter additional options, when cycle display to , will flash. And then press
enter to FAN function.
For each press button fan speed changes as follows: Remote controller:
LOW
Air conditioner is running under displayed fan speed. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.
Operation Mode
AUTO
COOL
HEAT
FAN
Display Board
DRY
nothing
Press FAN button.
MED HI
Remote Controller
Under the mode of auto operation, air conditioner will automatically select Cool or Heat operation according to room temperature. air conditioner according to room
Cooling only unit do not have displays and functions related with heating
In DRY mode, when room temperature becomes lower than temp.setting+2 at LOW speed regardless of FAN setting.
In HEAT mode,warm air will blow out after a short periodof the time due to cold-draft prevention function.
In FAN operation mode, the unit will not operate in COOL or HEAT mode but only in FAN mode ,AUTO is not available in FAN mode.And temp.setting is disabled.
When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.
In FAN mode,SLEEP operation is not available.
Display circulated
AUTO
Note
When FAN is set to AUTO, the
automatically adjusts the fan speed
temperature.
o
C,unit will run intermittently
Cautions:
When adjusting the flap by hand,turn off the unit.
When humidity is high,condensate water might occur at air outlet if all vertical louvers are
adjusted to left or
right. It is advisable not to keep horizontal flap at downward position for a long time in COOLor DRY
mode ,
otherwise, condensate water might occur.
Note: When restart after remote turning off, the remote
controller will automatically
return to the previous
set swing position.
HEALTH Operation
(This function is unavailable on some models.)
Press button to enter additional options, when cycle display to , will flashand then press ,enter to
health function. When cancel the function, please enter additional options again and to cancel health function.
The an i o n g e nerator i n the a i rc o n d iti o n e r can generate a lot of anion effectivel y b a l a n c e the q u a ntity of po s iti o n and an i o n i n th e a i r a n d also to kill bacteria and speed
up the dust sediment in the room and fin a l l y c l ean th e air in th e r o om.
2
Operation
Timer On/Off On-Off Operation
1.After unit starts, select your desired operation mode.
2.Press TIMER button to change TIMER mode. Every
time the button is pressed, display changes as follows:
Remote controller:
0.5h
TIMER ON TIMER OFF TIMER ON-OFF
0.5h 0.5h
0.5h
TIMER OFF-ON
Then select your desired TIMER mode (TIMER ON or
TIMER OFF or TIMER ON-OFF). " "or " "will flash.
3.Press / button to set time.
Press the button for each time, setting time in the first
12 hours increased by 0.5 hour every time, after 12
hours,increased by 1 hour every time.
Press the button for each time, settiing time in the first
12 hours decreased by 0.5 hour every time, after 12
hours,decreased by 1 hour every time.
BLANK
TURBO/QUIET Operation
(This function is unavailable on some models.)
(1)
TURBO Operation
When you need rapid heating or cooling, you can use this function.
Press TURBO button, the remote controller will show ,
and then achieve to the turbo function. Press again this
TURBO button , the turbo function will be cancelled.
(2)
QUIET Operation
Press button to enter additional options, when cycle display to , will flashand then press ,enter to
quiet function. When cancel the function, please enter
additional options again and to cancel quiet function.
Note
During TURBO operation, in rapid COOL mode ,
will show inhomogeneous temperature distribution.
Long period QUIET operation will cause effect of not too
cool or not too warm.
the room
It can be adjusted within 24 hours.
4.Confirm timer setting
After adjust the time,press button and confirm the
time ON or OFF button will not flash any more.
5.Cancel timer setting
Press the timer button by times until the time display
eliminated.
Hints:
After replacing batteries or a power failure happens, time
setting should be reset.
According to the Time setting sequence of TIMER ON or
TIMER OFF, either Start-Stop or Stop-Start can be achieved.
Emergency operation and test operation
Emergency Operation:
Use this operation only when the remote controller is defective or lost.
When the emergency operation switch is pressed,the" Pi "sound is heard once, which means the start of this operation.
In this operation, the system automatically selects the operation modes,cooling or fan or heat,according to the room temperature.
O
O
FAN
C
C
Timer mode
NO
NO
Designated temperature
O
C
26
AUTOMATIC
AUTOMATIC
Room temperature
ABOVE 23
BELOW 23
(Cooling only uint
Room temperature
It is not possible to operate in dry mode.
O
C
O
C
BELOW 23
Operation mode
COOLING
HEAT
O
C
Designated temperature
26
23
Operation mode
Air flow
Timer mode
NO
Pi
Air flow
AUTOMATIC
Test operation:
Test operation switch is the same as emergency switch.
Use this switch in the test operation when the room temperature is below 16 normal operation.
Continue to press the test operation switch for more than 5 seconds. After
you hear the "Pi" sound twice,
your finger from the switch: the cooling operation starts with the air flow speed "Hi".
After 30 minutes, test operation ends automatically(Only for 22K,24K unit).
o
C, do not use it in the
Pi Pi
release
3
Operation
Comfortable SLEEP
Press button , the remote controller will
show , and then achieve to the Press again this button , the be cancelled.
Operation Mode
1. In COOL,DRY mode
1 hours after SLEEP mode starts,temp.will become
O
C
1
temp.risesby 1 futher .The unit will run for further 6 hours then stops Temp. is higher than temp.setting so that room temperature won’t be too low for your
sleep.
SLEEP
sleep function.
SLEEP
sleep function will
higher than temp.setting.After another 1 hours,
O
C
SLEEP operation starts SLEEP operation stops
Approx.6hrs
O
C
1 hr
Rises 1
5. When quiet sleeping function is set to 8 hours the quiet sleeping time can not be adjusted.When TIMER function is
set,the quiet sleeping function can't be set up.After the sleeping function is set up,if user resets TIMER function, the sleeping function will be cancelled; the machine will be in the state of timing-on,if the two
either of their operation time is ended first,the unit will
time,
modes are set up at the same
stop automatically,and the other mode will be cancelled.
Note
When TIMER function is set, the sleeping function can’t be set up .After the sleeping function is set up
,if user resets
TIMER function, the sleeping function will be cancelled; the machine will be in the state of timing-on.
Note to the power failure resume:
press the sleep button ten times in five seconds and enter
function after hearing four sounds.And press the sleep button ten times within five seconds and leave this function after
hearing two sounds.
Power Failure Resume Function
If the unit is started for the first time, the compressor will not
start running unless 3 minutes have elapsed. When the power
resumes after power failure, the unit will run automatically,
and 3 minutes later the compressor starts running.
O
C
1 hr
Temp.setting
Rises 1
Unit stop
In COOL, DRY mode
2.In HEAT mode
1 hours after SLEEP mode starts, temp will become
O
2 C lower than temp.setting. After another 1 hours,
temp decrease by 2 C further. After more another
3 hours, temp.risesby 1 C further.The unit will run
O
O
for further 3 hours then stops.Temp. is lower than
temp. setting so that room temperature won't be too
high foryour sleep.
Temp.setting
1 hr
Decreases 2
1 hr
Decreases 2
Unit stop
O
C
O
C
3 hrs
3 hrs
SLEEP
operation starts
Rises 1OC
SLEEP
operation stops
In HEAT mode
3.In AUTO mode
The unit operates in corresponding sleep mode
corresponding sleep mode adapted to the automatically selected operation mode.
4. In FAN mode
It has no SLEEP function.
Healthy airflow Operation
1.Press to starting
Setting the comfort work conditions.
2.The setting of healthy airflow function
Press button to enter additional options,Press this button continuously, the louvers location will cycle between
in the following three locations, to choose the swing location
what you needed,and then press button to confirm.
Healthy airflow upwarder
3.The cancel of the healthy airflow function
Press button to enter additional options,Press this button continuously, the louvers location will cycle between
in the following three locations again,and then press button to cancel.
Notice: Do not direct the flap by hand. Otherwise, the grille will run incorrectly. If the grille is not run correctly, stop
for a minute and then start, adjusting by remote
controller.
Note:
1.After setting the healthy airflow function, the position
grill is fixed.
2.In cooling, it is better to select the
3.In cooling and dry, using the air conditioner for a long
time under the high air humidity, condensate water may
occur at the grille .
Healthy airflow downwarder
Present position
mode.
4
Maintenance
For Smart Use of The Air Conditioner
Setting of proper room temperature
Proper temperature
Close doors and windows during operation
During cooling operation prevent the penetration of direct sunlight with curtain or blind
If the unit is not to be used for a long time, turn off the power supply main switch.
OFF
Do not block the air inlet or outlet
Use the timer effectively
Use the louvers effectively
Remote Controller
Do not use water ,wipe the controller with a dry cloth.Do not use glass cleaner or chemical cloth.
Do not use the following for cleaning
Gasoline,benzine, thinner or cleanser may damage the coating of the unit.
Air Filter cleaning
Open the inlet grille by pulling it upward.
Remove the filter.
Push up the filter's center tab slightly until it is released from the stopper, and remove the filter downward.
Clean the filter.
Use a vacuum cleaner to remove dust, or wash the filter with water.After washing, dry the filter completely in the shade.
Attach the filter.
Attach the filter correctly so that the "FRONT" indication is facing to the front.Make sure that the filter is completely fixed behind the stopper.If the right and left filters are not attached correctly, that may cause defects.
Close the inlet grille.
Indoor Body
Wipe the air conditioner by using a soft and dry cloth.For serious stains,use a neutral detergent diluted with water.Wring the water out of the cloth before wiping.then wipe off the detergent completely.
O
Hot water over 40 discoloring or deformation.
C(104OF) may cause
Once every two weeks
Replacement of Air Purifying Filter
1.Open the lnlet Grille
Prop up the inlet grille by using a
small device named grille-support
which located in the right side of
the indoor unit.
2.Detach the standard air filter
Slide the knob slightly upward to release the filter, then withdraw it.
Detach old Air Purifying Filter
3.Attach Air Purifying Filter
Put air purifying filter appliances into the right and left filter frames.
(NOTE: Air purifying filter is optional part)
4.Attach the standard air filter
(Necessary installation)
ATTENTION: The white side of the photocatalyst air purifying
filter face outside,
The green side of the bacteria-killing medium air
purifying filter face outside,
5.Close the Inlet Grille
Close the Grille surely
NOTE:
The photocatalyst air purifying filter will be solarized in fixed time. In normal family,
The bacteria-killing medium air purifying filter will be used for a long time,no need for replacement. But in the period of using them ,you should remove the dust frequently by
using vacuum cleaner or flaping them lightly,otherwise ,
its performance will be affected.
and the black side face the unit.
and the white side face the unit.
it will be solarized every 6 months.
Please keep the bacteria-killing medium air purifying filter in the cool and dry conditions when you stop using it,or its ability of sterilization will
avoid long time directly sunshine
be
reduced.
5
Cautions
WARNING
Please call Sales/Service Shop for the Installation. Do not attempt to install the air conditioner by yourself because improper works
may cause electric shock, fire, water leakage.
WARNING
When abnormality such as burnt-small found, immediately stop the operation button and contact sales shop.
Use an exclusive power source with a circuit breaker
Check proper installation of the drainage securely
OFF
Connect power supply cord to the outlet completely
STRICT
ENFORCEMENT Do not use power supply cord in a bundle.
PROHIBITION
Do not start or stop the operation by disconnecting the power supply cord and so on.
PROHIBITION
STRICT
ENFORCEMENT
Use the proper voltage
STRICT
ENFORCEMENT
Take care not to damage
the power supply cord.
PROHIBITION
Do not channel the air flow directly at people, especially at infants or the aged.
PROHIBITION
STRICT ENFORCEMENT
1.Do not use power supply cord extended or connected in halfway
2.
Do not install in the place where there is any
possibility of inflammable gas leakage around the unit.
3.Do not get the unit exposed
to vapor or oil steam.
PROHIBITION
Do not insert objects into the air inlet or outlet.
PROHIBITION
Do not try to repair or reconstruct by yourself.
Connect the earth cable.
earthing
Do not use for the purpose of storage of food, art work, precise equipment, breeding, or cultivation.
PROHIBITION
Do not install the unit near a fireplace or other heating apparatus.
PROHIBITION
Do not place animals or plants in the direct path of the air flow
PROHIBITION
CAUTION
Take fresh air occasionally especially when gas appliance is running at the same time.
STRICT
ENFORCEMENT
Check good condition of the installation stand
PROHIBITION
Do not place any objects on or climb on the unit.
PROHIBITION
Do not operate the switch with wet hand.
PROHIBITION
Do not pour water onto the unit for cleaning
PROHIBITION
Do not place flower vase or water containers on the top of the unit.
PROHIBITION
6
Trouble shooting
Before asking for service, check the following first.
Cause or check points
When unit is stopped, it won't restart immediately until 3 minutes have elapsed to protect the system. When the electric plug is pulled out and reinserted, the protection circuit
will work for 3 minutes to protect the air conditioner.
During unit operation or at stop, a swishing or gurgling noise may
be heard.At first 2-3 minutes after unit start, this noise is more noticeable.
(This noise is generated by refrigerant flowing in the system.)
During unit operation, a cracking noise may be heard.This noise is
generated by the casing expanding or shrinking because of temperature changes.
Should there be a big noise from
air flow in unit operation, air filter may be too dirty.
This is because the system circulates smells from the interior air such as the smell of furniture, paint, cigarettes.
During COOL or DRY operation, indoor unit may blow out mist.
This is due to the sudden cooling of indoor air.
In DRY mode, when room
temperature becomeslower
than temp.setting+2 run intermittently at LOW speed regardless of FAN setting.
Is power plug inserted? Is there a power failure? Is fuse blownout?
Is the air filter dirty?
Normally it should be cleaned
every 15 days.
Are there any obstacles before inlet and outlet? Is temperature set correctly? Are there some doors or
windows left open?
Is there any direct sunlight through the window during the cooling operation?(Use curtain)
Are there too much heat sources or too many people in the room during cooling operation?
o
C,unit will
Normal Performance inspection
Multiple
check
Phenomenon
The system does not restart immediately.
Noise is heard
Smells are generated.
Mist or steam are blown out.
In dry mode,
speed can’t be changed.
Poor cooling
fan
Cautions
The machine is adaptive in following situation
1.Applicable ambient temperature range:
For: T1
For: T3
Indoor
Cooling
Outdoor
Indoor
Heating
Outdoor
Indoor
Cooling
Outdoor
Indoor
Heating
Outdoor
Maximum: D.B / W.B 32 Minimum: D.B / W.B Maximum: D.B Minimum: D.B Maximum: D.B Minimum: D.B Maximum: D.B / W.B Minimum: D.B / W.B
Maximum: D.B / W.B Minimum: D.B / W.B
Maximum: D.B / W.B Minimum: D.B
Maximum: D.B Minimum: D.B
Maximum: D.B / W.B Minimum: D.B / W.B
29oC/19oC 18
54 18
27 15
24
-7
2. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified
The type of connecting wire is H05RN-F or H07RN-F
3. If the fuse on PC board is broken please change it with a fuse
type T. 3.15A/250V.
If the fuse of outdoor unit on PC board is broken, please change it with the type of T. 25A/250V.
4.The distance between the indoor unit and the floor should be
more than 2m.
5.The wiring method should be in line with the local wiring standard.
6.
After installation, the power plug should be easily reached..
7.The used batteries should be disposed of properly.
8.The appliance is not intended to use by young children or infirm persons without supervision.
9.Young children should be supervised ensure that they do not
play with the appliance.
10.The appliance must be installed on a strong enough support.
11.The wiring diagram is attached inside the machine.
o
C/23
o
C/14
18
o
43
C/26
o
C
18
o
C
27
o
C
15
o
C/18
24
o
C/-8
-7
o
C/14oC
o
C/24oC
o
C
o
C
o
C
o
C/18oC
o
C/-8oC
o
C
o
C
o
C
o
C
o
C
person.
Application temp. range of air conditioner -7
T1: T3:
Application temp. range of air conditioner -7
7
o
C~43oC.
o
C~54oC.
Loading...