Haier HSU-18CR03-Y user guide manual

Please read this operation manual before using the air conditioner.
SPLIT TYPE ROOM AIR CONDITIONER
OPERATION MANUAL
0010515222
HSU-12CR03-Y
HSU-18CR03-Y
It must be noticed that air conditioner system contains refrigerants, which require speciali­zed waste disposal. The valuable materials contained in an air conditioner can be recycled .Contact your local waste disposal center for proper disposal of an old air conditioner and contact your local authority or your dealer if you have any question. Please ensure that the pipework of your air conditioner does not get damagedprior to being picked up by the relevant waste disposal center, and contribute to environmental awareness by insisting on an appropriate, anti-pollution method of disposal.
Cautions
Disposal of the old air conditioner
All the packaging materials employed in the package of your new air conditioner may be disposed without any danger to the environment.
The cardboard box may be broken or cut into smaller pieces and given to a waste paper disposal service. The wrapping bag made of polyethylene and the polyethylene foam pads
contain no fluorochloric hydrocarbon.
All these valuable materials may be taken to a waste collecting center and used again after adequate recycling.
Consult your local authorities for the name and address of the waste materials collecting centers and waste paper disposal services nearest to your house.
Disposal of the packaging of your new air conditioner
Before starting the air conditioner, read the information given in the User's Guide caref­ully. The User's Guide contains very impor­tant observations relating to the assembly, operation and maintenance of the air conditioner.
The manufacturer does not accept respon­sibility for any damages that may arise due to non-observation of the following instruction.
Damaged air conditioners are not to be put into operation. In case of doubt, consult your supplier.
Use of the air conditioner is to be carried out in strict compliance with the relative instructions set forth in the User's Guide.
Installation shall be done by professional people, don't install unit by yourself.
For the purpose of the safety,the air con­ditioner must be properly grounded in acco­rdance with specifications.
Always remember to unplug the air conditioner before openning inlet grill. Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the outlet.
All electrical repairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditioner.
Safety Instructions and Warnings
Do not damage any parts of the air conditioner that carry refrigerant by piercing or performating the air conditioner's tubes with sharp or pointed items, crushing or twisting any tubes, or scraping the coatings off the surfaces. If the refrigerant spurts out and gets into eyes, it may result in serious eye injuries.
1
3. If the fuse of indoor unit on PC board is broken,please change it with the type of
T. 3.15A/ 250V.
Do not obstruct or cover the ventilation grille of the air conditoner.Do not put fingers or any other things into the inlet/outlet and swing louver.
Do not allow children to play with the air conditioner.In no case should children be allowed to sit on the outdoor unit.
The refrigerating circuit is leak-proof.
1.Applicable ambient temperature range:
Cooling
Indoor
Maximum:D.B/W.B
35oC/24oC
46oC/27oC
18oC/14oC
Maximum:D.B/W.B Minimum:
Minimum:D.B/W.B
Outdoor
Specifications
The machine is adaptive in following situation
10 .The power plug and connecting cable
must have acquired the local attestation.
2. If the power supply cord is damaged, it must be replaced by the manufacturer
or its service agent or a similar qualified person.
4. The wiring method should be in line with the local wiring standard.
5. After installation, the power plug should be easily reached.
6. The waste battery should be disposed properly.
7. The appliance is not intended for use by young children or infirm persons
without supervision.
8. Young children should be supervised to ensure that they do not play with the applience.
9.Please employ the proper power plug, which fit into the power supply cord.
Cautions
11.In order to protect the units,please turn
off the A/C first, and at least 30 seconds later, cutting off the power.
18oC
D.B
2
Cautions
STRICT ENFORCEMENT
Safety Instruction
Installation
WARNING
Please read the following Safety Instructions carefully prior to use.
The instructions are classified into two levels, WARNING and CAUTION according to the seriousness of possible risks and damages as follows. Compliance to the instructions are strictly required for safety use.
Please call Sales/Service Shop for the Installation.
Do not attempt to install the air conditioner by yourself because improper works may cause electric shock, fire, water leakage.
lnstallation in a inadequate place may cause accidents. Do not install in the following place.
Connect the earth cable.
earthing
Do not install in the place where there is any possibility of inflammable gas leakage around the unit.
Do not get the unit exposed to vapor or oil steam.
Check proper installation of the drainage securely
PROHIBITION PROHIBITION
CAUTION
3
Cautions
WARNING
When abnormality such as burnt-small found, immediately stop the operation button and contact sales shop.
OFF
Use an exclusive power source with a circuit breaker
ENFORCEMENT
Connect power supply cord to the outlet completely
Use the proper voltage
Do not use power supply cord in a bundle.
Take care not to damage
the power supply cord.
Do not use power supply cord
extended or connected in halfway
STRICT
ENFORCEMENT
STRICT
STRICT
ENFORCEMENT
PROHIBITION
PROHIBITION
PROHIBITION
PROHIBITION
Do not start or stop the operation by disconnecting the power supply cord and so on.
Do not channel the air flow directly at people, especially at infants or the aged.
Do not try to repair or reconstruct by yourself.
Do not use for the purpose of storage of food, art work, precise equipment, breeding, or cultivation.
CAUTION
Take fresh air occasionally especially when gas appliance is running at the same time.
PROHIBITION
STRICT
ENFORCEMENT
Do not operate the switch with wet hand.
PROHIBITION
PROHIBITION
PROHIBITION
PROHIBITION
PROHIBITION
Do not install the unit near a fireplace or other heating apparatus.
Check good condition of the installation stand
Do not pour water onto the unit for cleaning
PROHIBITION
Do not place animals or plants in the direct path of the air flow
Do not place any objects on or climb on the unit.
Do not place flower vase or water containers on the top of the unit.
Do not insert objects into the air inlet or outlet.
PROHIBITION
PROHIBITION
PROHIBITION
4
Parts and Functions
Vitamin C layer+ Bacteria-killing medium sets
air ionization purify layer
Indoor unit
Outdoor unit
OUTLET CONNECTING PIPING AND ELECTRICAL
WIRING
INLET
1
2
3
4
DRAIN HOSE
Inlet
Horizontal flap (adjust up and down air flow Don't adjust it manually)
Vertical blade(inside)
Inlet grille
Power plug
(adjust left and right air flow)
Outlet
Anion generator
(inside)
Air filter(inside)
display board(inside)
(inside)
(inside)
5
Parts and Functions
33
34
16
21
17
11
15
22
Used to set air ionization purify and healthy function.
9. Purify button
Used for unit start and stop.
10. ON/OFF button
11. TIMER ON display
12. FAN SPEED display
LOW HI
MED AUTO
13. LOCK display
14. SWING UP/DOWN display
15. SLEEP display
16. HEALTH display
Used to select your desired temperature.
Operation mode
AUTO FANCOOL DRY
Remote controller
17. Operation mode display
Display board
19. POWER/SOFT display
20. Left/right air flow display
Remote controller: to display the TEMP. setting.
21. TEMP display
22. TIMER OFF display
23. CLOCK display
24. TEMP button
Used to select fan speed: LOW,MED, HI, AUTO.
25. FAN button
Used to set the health airflow mode.
26. HEALTH AIRFLOW button
27. SWING UP/DOWN button
Used to select up or down air sending direction.
28. SWING LEFT/RIGHT button
Used to select left/right air flow.
29.
FRESH
button(optional)
Used to confirm timer and clock settings.
30. SET button
31. POWER/SOFT button
Used to set power/soft function.
Use to set fresh air function.
Used to select CODE A or B with a press,A or B will be displa
yed on LCD.
Please select A without special explanation.
1.CODE
When the remote controller appears abnormal, use a shar
p pointed article to press this button
to reset the remote controller normal.
2.RESET
Used to select TIMER ON, TIMER OFF, TIMER ON-OFF
.
4. TIMER button
Used to set correct time.
5. CLOCK button
Used to select sleep mode.
6. SLEEP button
7. MODE button
Used to set clock and timer setting.
8. HOUR button
Used to lock buttons and LCD display. If pressed, the other b
uttons will be disabled and the lock condition display appears. Press it once again, lock will be canceled and lock condition display disappears.
32. LOCK
AUTO COOL DRY FAN
33.
Remote signal receiver
34. Emergency operation button(touch key)
Used to set emergency operation and test operation.
18.Singal sending display
NOTE:
1.Cooling only unit do not have functions and displays related with heating.
2.The CODE button on this remote controller is not available.
3.LIGHT button
Control the lightening and extinguishing of the indoor LED display board.
POWER SOFT
FRESH
28
19
PURIFY
6
Remove the batteries in case unit won't be in usage for a long period. If there are any display after taking-out, just need to press reset key.
Clock Set
When unit is started for the first time and after replacing batteries in remote controller, clock should be adjusted as follows:
Remote controller's operation
3. After time setting is confirmed, press SET, "AM" or "PM" stop flashing, while clock starts working.
2. Press or to set correct time. Each press will increase or decrease 1 min. If the button is kept depressed, time will change quickly.
1. Press CLOCK button,"AM" or "PM" flashes.
When in use, put the signal transmission head directly to the receiver hole on the indoor unit.
The distance between the signal transmission head and the receiver hole should be within 7m without any obstacle as well.
Don't throw or knock the remoter controller.
When electronic-started type fluorescent lamp or change-over type fluorescent lamp or wireless telephone is installed in the room, the receiver is apt to be disturbed in receiving the signals, so the distance to the indoor unit should be shorter.
Loading of the battery
Load the batteries as illustrated right 2 R-03 (7#) batteries
Remove the battery cover:
Slightly press" "area and push down the cover as illustrated.
Load the battery:
Be sure that the loading is in line with the "+" / "-". request as illustrated on the bottom of the case.
Put on the cover again.
Confirmation indicator:
After pressing power ON/OFF, if no display, reload the batteries.
Note:
Full display or unclear display during operation indicates the batteries have been used up. Please change batteries.
Used two new same-typed batteries when loading.
If the remote controller can't run normally during operation, please remove the batteries and reload several minutes later.
Hint:
Parts and Functions
POWER/SOFT
FRESH
7
Operation
2.The purification function of AIP: DC high voltage bring high voltage electrostatic field, which ionize air into positive and negative ion. a great deal of positive and negative ion adhere to dust passing by, so the dust become "particle with electric charge". so the dust passing by adheres to the AIP board under the force from the electric field, which purifies the unit.
3.When power off, press the purify button, the Remote controller shows "FAN, low, AIP, and negative ion", and the TIMER function is available.
2.Health anion function
BRIEF INTRODUCTION TO
AIR IONIZATION PURIFY AND
HEALTH ANION FUCTION
1.The anion generator in the air conditioner can generate a lot of anion effectively balance the quantity of position and anion in the air and also to kill bacteria and speed up the dust sediment in the room and finally clean the air in the room.
Press ON/OFF on the remote controller, unit starts.
Press Purify button. is displayed on the remote controller and is displayed on the display board .
Air conditioner starts
air ionization purify and
health anion function operation.
1.Unit start
Display board
Remote controller
When indoor fan motor is running, it has air ionization
purify and healthy process function.
For twice press, and disappear,the operation stops.
HEALTH operation
POWER/SOFT
FRESH
PURIFY
8
Then
Select Auto operation
LOW
MED
HI
AUTO
Operation
About Auto Operation Under the mode of auto operation, air conditioner will automatically select Cool, Dry or Fan operation according to room temperature.
5.Unit stop
Press ON/OFF button, the unit stops.
1. Unit start
Press ON/OFF on the remote controller, unit starts.
2.Select operation mode
Press MODE button. For each press, operation mode changes as follows:
Remote controller:
Press FAN button. For each press, fan speed changes as follows:
Remote controller:
Press TEMP. button
Every time the button is pressed, temp.setting increase 1oC,if kept depressed, it will increase rapidly
Every time the button is pressed, temp.setting decrease 1oC,if kept depressed, it will decrease rapidly
Select a desired temperature.
4.Fan speed selection
3.Select temp.setting
Air conditioner is running under displayed fan speed. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.
Display board
Remote controller
AUTO COOL DRY FAN
Auto Operation
POWER/SOFT
FRESH
PURIFY
9
Operation
2.Select operation mode
Press FAN button. For each press, fan speed changes as follows:
Press MODE button. For each press, operation mode changes as follows:
Remote controller:
Remote controller:
Then Select COOL operation
Press TEMP. button
Every time the button is pressed, temp.setting increase 1
o
C, if kept depressed, it will increase
rapidly Every time the button is pressed, temp.setting
decrease 1
o
C,if kept depressed, it will decrease
rapidly
Select a desired temperature.
4.Fan speed selection
3.Select temp.setting
5.Unit stop
Air conditioner is running under displayed fan speed. When F
AN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.
Press ON/OFF button, the unit stops.
AUTO
LOW
MED
HI
AUTO
COOL DRY FAN
1. Unit start
Press ON/OFF on the remote controller, unit starts.
Cool Operation
Remote controller
Display board
POWER SOFT
FRESH
PURIFY
10
Operation
2.Select operation mode
Press FAN button. For each press, fan speed changes as f
ollows:
Press MODE button. For each press, operation mode changes as f
ollows:
Remote controller:
Remote controller:
Then Select DRY operation
Press TEMP. button
Every time the button is pressed, temp.setting increase 1
o
C,if kept depressed, it will increase
rapidly Every time the button is pressed, temp.setting
decrease 1
o
C,if kept depressed, it will decrease
rapidly
Select a desired temperature.
4.Fan speed selection
3.Select temp.setting
5.Unit stop
Press ON/OFF button, the unit stops.
COOL operation starts when room temp
.is higher than temp.set ing.
On reaching temp.setting +2oC unit will run in mild DRY mode.
Ultra-low air flow
Temp.setting+2oC Temp.setting
AUTO
LOW
MED
HI
AUTO
COOL DRY FAN
Dry Operation
1. Unit start
Press ON/OFF on the remote controller, unit starts.
Air conditioner is running under displayed fan speed. In DR
Y mode, when room temperature becomes lower than temp.setting+2oC,unit will run intermittently at LOW speed regardless of FAN setting.
Display board
Remote controller
POWER/SOFT
FRESH
PUR FY
11
Fan Operation
2.Select operation mode
Press FAN button. For each press, fan speed changes as follows:
Press MODE button. For each press, operation mode changes as follows:
Remote controller:
Remote controller:
Then Select FAN operation
3.Fan speed selection
4.Unit stop
About FAN operation
In FAN operation mode, the unit will not operate in COOL mode but only in FAN mode ,AUTO is
not
available in FAN mode.And temp.setting is disabled.
In FAN mode,SLEEP operation is
not available.
Press ON/OFF button, the unit stops.
AUTO
LOW
MED
HI
COOL DRY FAN
Operation
1. Unit start
Press ON/OFF on the remote controller, unit starts.
Remote controller
POWER SOFT
FRESH
Display board
12
PURIFY
2.Up and down air flow direction
Horizontal flap
Pos.1
Pos.1 Pos.2 Pos.3 Pos.4 Pos.6
Pos.1 Pos.2 Pos.3 Pos.4 Pos.5 Pos.6
Pos.2
Pos.3
Pos.4
Pos.5
Pos.6
(Auto swing)
For each press of button, air flow direction on remote controller displays as follows according to different operation modes:
remote controller:
COOL/DRY/FAN
remote controller:
The horizontal flap will swing according to the above positions
AUTO:
1.Status display of air sending
Vertical blade
Pos.1
Pos.2
Pos.3
Pos.4
Pos.5
Pos.6
Pos.7
Pos.8
3.Left and right air flow direction
For each press of button, remote controller displays as follows :
remote controller:
Pos.1 Pos.2 Pos.3 Pos.4 Pos.5 Pos.6 Pos.7 Pos.8
The vertical blade will swing according to the above positions.
Note:When restart after remote turning off, the remote controller will automatically memorize the previous set swing position.
Air Flow Direction Adjustment
OWERSO
RESH
URI
Operation
13
Operation
Sleep Operation
Remote Controller
Display board
POWER/SOFT
FRESH
PURIFY
Power Failure Resume Function
If the unit is started for the first time, the compressor will not start running unless 3
minutes have elapsed. When the power resumes after power failure, the unit will run automatically, and 3 minutes later the compressor starts running
2.
In AUTO mode
The unit operates in corresponding sleep mode adapted to the automatically selected
operation mode.
3. In FAN mode
It has no SLEEP function.
When TIMER function is set, the sleeping function can't be set up .After the sleeping function is set up, if user resets TIMER function, the sleeping function will be cancelled; the machine will be in the state of
timing-on.
4.
5.Note to the power failure resume:
press the sleep button ten times in five seconds and enter this function after hearing four sounds. And press the sleep button ten times within five seconds and leave this function after hearing two sounds.
Before going to bed, you can simply press the SLEEP button and unit will operate in SLEEP mode and bring you a sound sleep.
Use of SLEEP function
After the unit starts, set the operation status, then press SLEEP button before which the clock must be adjusted and time being set.
Operation
Operation Mode
1. In COOL,DRY mode
1 hours after SLEEP mode starts, temp. will become 1OC higher than temp. setting. After another 1 hours, temp. rises by 1OC further.
The unit will run for further 6 hours then stops. Temp. is higher than temp. setting so that room
temperature won't be too Iow for your sleep.
SLEEP operation starts SLEEP operation stops
Approx.6hrs
1 hr
Rises 1OC
Rises 1OC
Temp.setting
Unit stop
In COOL, DRY mode
1 hr
14
BLANK
TIMER ON TIMER OFF TIMER ON-OFF
Then select your desired TIMER mode (TIMER ON or TIMER OFF). " "or " "will flash.
Press HOUR button. Every time the button is pressed, time setting increases 1 min, if kept depressed, it will increase rapidly
. Every time the button is pressed, time setting decreases 1 min, if kept depressed, it will decrease rapidly. It can be adjusted within 24 hours.
After setting correct time, press SET button to confirm " "or" "on the remote controller stops flashing. T
ime displayed: Unit starts or stops at x hour x min.
(TIMER ON or TIMER OFF).
Operation
Timer On/Off Operation
Hints: After replacing batteries or a power failure happens, time setting should be reset. Remote controller possesses memory function, when use TIMER mode next time, just press SET button after mode selecting if time setting is the same as previous one.
Set clock correctly before starting TIMER operation.
1.
After unit starts, select your desired operation mode
Operation mode will be displayed on LCD.
2. Timer mode selection Press TIMER button to change TIMER mode. Every time the button is pressed, display changes as follows: Remote controller:
3.Time setting
4.Confirming your setting
5.Cancel TIMER mode
Just press TIMER button several times until TIMER mode disappears.
Display board
Remote Controller
ER
FRESH
15
BLANK
T MER ON T MER OFF TIMER ON-OFF
Then select your desired TIMER mode (TIMER ON - OFF). " "will flash.
Press HOUR button. Every time the button is pressed, time setting increases 1 min, if kept depressed, it will increase rapidly
. Every time the button is pressed, time setting decreases 1 min, if kept depressed, it will decrease rapidly. It can be adjusted within 24 hours.
After setting correct time, press TIMER button to confirm " " on the remote controller stops flashing. " " starts flashing. T
ime displayed: Unit starts or stops at x hour x min.
After time setting,press SET button to confirm. " " on the remote controller stops blinking. T
ime displayed:Unit stops at x hour x min.
Operation
Remote Controller
Timer On-Off Operation
Just press TIMER button several times until TIMER mode disappears. According to the
Time setting sequence of TIMER ON or TIMER OFF, either Start-Stop or Stop-Start can be achieved.
Set clock correctly before starting TIMER operation.
1.
After unit starts, select your desired operation mode . Operation mode will be displayed on LCD.
2. Timer mode selection Press TIMER button to change TIMER mode. Every time the button is pressed, display changes as follows: Remote controller:
3.Time setting
4.Timer confirming for TIMER ON
5.Time setting for TIMER OFF
6.Time confirming for TIMER OFF
To cancel TIMER mode
Just press HOUR button ,follow the same procedure in "T
ime setting for TIMER ON"
Display board
WER
FRESH
16
Operation
POWER
SOFT
BLANK
Stop the display at
Stop the display at
POWER
SOFT
BLANK
POWER/SOFT Operation
SOFT Operation
You can use this function when silence is needed for rest or reading.
In COOL mode, compressor runs in high frequency for 15 min then returns to original status setting.
In POWER operation status:
Hints:
During POWER operation, in rapid COOL mode, the room will show inhomogeneous temperature distribution. Long period SOFT operation will cause effect of not too cool.
Remote controller
Selecting of POWER operation
POWER Operation
When you need rapid cooling, you can use this function.
Press POWER/SOFT button twice ,POWER/SOFT disappears.
To cancel SOFT operation
Press POWER/SOFT button. Every time the button is pressed, display changes as follows:
Selecting of SOFT operation
In SOFT operation mode, fan speed automatically takes"ultra-low"
Press POWER/SOFT button. Every time the button is pressed, display changes as follows:
Press POWER/SOFT button twice ,POWER/SOFT disappears.
To cancel POWER operation
FRESH
17
Operation
1.Press ON/OFF to starting
The liquid crystal will display the working state of last time (Except timer
, sleeping, power/soft and health airflow).
Setting the comfort work conditions.
2.The setting of health airflow function
1).Press the button of health airflow, appears on the display
. The nether inlet and outlet grills of the air condit­ioner are closed and the airflow is blown horizontally from the above inlet and outlet grills. Avoid the strong airflow blows direct to the body.
2).Press the button of health airflow again, appears on the display. The above inlet and outlet grills of the air cond­itioner are closed and the airflow is blown vertically from the nether inlet and outlet grills. Avoid the strong airflow blows direct to the body.
Note:
1 .After setting the health airflow function, the position of inlet and outlet grills is fixed.
2.In cooling, it is better to select the mode.
3.In cooling and dry
, using the air conditioner for a long time under the high air humidity, a phenomenon falling drips of water occurs at the outlet grille .
4.Select the appropriate fan direction according to the actual conditions.
3.The cancel of the health airflow function
Press the button of health airflow again, both the inlet and outlet grills of the air conditioner are opened, and the unit goes on working under the condition before the setting of health airflow function. After stopping, the outlet grille will close automatically
. Notice: Cannot pull direct the outlet grille by hand. Otherwise, the grille will run incorrectly. If the grille is not run correctly, stop for a minute and then start, adjusting by remote controller.
Health airflow Operation
Remote controller
POWER/SOFT
RES
18
Operation
When the remote controller is manipulated, it gets the system back to the nor
mal operation mode.
Removal of the restriction of emergency or test operation
Press the emergency operation switch once more, or manipulate through the remote controller
; the "Pi" sound, the emergency or test operation is terminated.
Emergency operation
Test operation
Emergency and Test Operation (wall-mounted type)
Use this operation only when the remote controller is def
ective or lost.
When the emergency operation switch is pressed,the" Pi "sound is heard once
, which means
the start of this operation.
In this operation, the system automatically selects the oper
ation modes, cooling or fan, according
to the room temperature.
It is not possible to operate in dry mode.
Temperature
Operation mode
Designated temperature
Timer mode
Air flow
ABOVE 21OC BELOW 21OC
COOLING
FAN
24OC
24OC
NO
NO
AUTOMATIC
AUTOMATIC
Test operation switch is the same as emergency switch.
Use this switch in the test operation when the room temper
ature is below 16OC, do not use it in the normal
operation.
Continue to press the test operation switch for more than 5 seconds
. After you hear the "Pi" sound twice, release your finger from the switch: the cooling operation starts with the air flow speed "Hi".
After 30 minutes, test operation ends automatically.
eme g­en
emerg­en
19
Maintenance
Setting of proper room temperature
Close doors and windows during operation
If the unit is not to be used for a long time, turn off the power supply main switch.
Use the timer effectively
Use the louvers effectively
Do not block the air inlet or outlet
Proper temperature
During cooling operation prevent the penetration of direct sunlight with curtain or blind
OFF
For Smart Use of The Air Conditioner
20
Maintenance
For Smart Use of The Air Conditioner
WARNING
Remote Controller
Do not use the following for cleaning
Do not use water, wipe the controller with a dry cloth.Do not use glass cleaner or chemical cloth.
Gasoline,benzine, thinner or cleanser may damage the coating of the unit.
Hot water over 40OC(104OF) may cause discoloring or deformation.
Wipe the air conditioner by using a soft and dry cloth.For serious stains,use a neutral detergent diluted with water.Wring the water out of the cloth before wiping.then wipe off the detergent completely.
Indoor Body
Before maintenance,be sure to turn off the system and the circuit breaker.
Air Filter cleaning
Open the inlet grille by pulling it upward.
Remove the filter.
Clean the filter.
Attach the filter.
Close the inlet grille.
Push up the filter's center tab slightly until it is released from the stopper, and remove the filter downward.
Use a vacuum cleaner to remove dust, or wash the filter with water.After washing, dry the filter completely in the shade.
Attach the filter correctly so that the "FRONT" indication is facing to the front.Make sure that the filter is completely fixed behind the stopper.If the right and left filters are not attached correctly, that may cause defects.
Once every two weeks
21
Maintenance
The inlet grill is supported by its top plate at the right side.
3.Take the VC layer + Bacteria-killing medium sets
Take out Take the VC layer or the Bacteria-killing medium sets from the filter. Push the bottom frame of AIP layer, and push up the handle at the same time in order take out the AIP layer board in turns.
4. The installation of AIP layer,VC layer + Bacteria-killing medium sets (must be installed)
Put down the inlet grill’s top plate, and close the inlet grill.
(AIP board)
****
In order to keep the AIP layer having a highly work effect ,it should be cleaned regularly or aperiodically just according to the working environment.
1. Turn off the A/C electricity supply and make sure that AIP layer is not working.Then clean the AIP layer after turning off it five minutes later.
2. Please brush off the dust on AIP board,then steep it into cleaning agent water and wash it.
3. After cleaning AIP board pleas put it on a dry place until it is totally dry.
4. Ensure AIP board is dry enough then install it in the its position along the slide way . Make sure it is as before and could work well.
Note:the green aspect of the bacteria-killing medium air purifying filter will face outside, the white aspect will face to the machine. The yellow aspect of the VC layer will face outside, the white aspect will face to the machine.
Common sense:
1.Open the lnlet Grille
2.Detach the standard air filter
5.Close the Inlet Grille
inlet grill’s top plate
The installation and cleanout AIP layer, VC layer + Bacteria-killing medium sets
Push up the filter's center tab slightly until it is released from the stopper, and remove the filter downward.
In the use, please note to clean the filter frequently (take off the back suction cleaner or lightly pat it) to avoid the operating effect is lowered due to the dust covering the filter. AIP layer and bacteria-killing medium filter is strictly prohibited from being cleaned by water.
AIP(air ionization purify)
(bottom frame)
The the bacteria-killing medium filter not in use should be stored in shade, cool and dry place. Please don't expose it to the sunlight for a long time otherwise the degerming performance will drop.
The AIP layer will be replaced in fixed time. In normal family, it will be replaced every 6 months.
22
Maintenance
To Keep Your Air conditioner in Good Condition after Season.
1. Operate in cooling mode for 2-3 hours.
2. Put off the power supply cord.
4. Take out the batteries from the
wireless remote controller.
3. Cleaning the body.
To prevent breeding mold or bad smell, be sure to operate at the designated temperature or 30
O
C,cooling
mode and High speed fan mode for 2-3 hours.
23
Caution
Before Setting in High season
1. Cleaning the standard air filter.
2. Connecting the earthing cable.
3. Do not block the air inlet or outlet.
4. Plug-in
Caution
After brush away dust at the plug, insert the plug of the power supply cord into the outlet completely.In case of suing exclusive circuit breaker,switch on the circuit breaker.
NO WET HAND
EARTHING
Operation without filter may cause troubles.Be sure to attach both right and left filters prior to the operation. Each of them are of different shapes.
Incomplete earthing may cause an electric shock.
Maintenance
24
Trouble shooting
Is the air filter dirty? Normally it should be cleaned e
very 15 days. Are there any obstacles before inlet and outlet? Is temperature set correctly? Are there some doors or windows left open? Is there any direct sunlight through the window during the cooling operation?(Use curtain) Are there too much heat sources or too many people in the room during cooling operation?
Cause or check points
Phenomenon
The system does not restart immediately
.
Noise is heard:
Smells are generated.
Mist or steam are blown out
Does not work at all.
Multiple chec
k
Normal Performance inspection
Poor cooling
Before asking for service, check the following first.
When unit is stopped, it won't restart immediately until 3 min
utes have elapsed to protect the system. When the electric plug is pulled out and reinserted, the protection circuit will work for 3 minutes to protect the air conditioner.
During unit operation or at stop, a swishing or gurgling noise ma
y be heard. At first 2-3 minutes after unit start, this noise is more noticeable. (This noise is generated by refrigerant flowing in the system.) During unit operation, a cracking noise may be heard. This noise is generated by the casing expanding or shrinking because of temperature changes. Should there be a big noise from air flow in unit operation, air filter may be too dirty.
This is because the system circulates smells from the inter
ior air such as the smell of
furniture, cigarettes.
During COOL or DRY operation, indoor unit ma
y blow out mist. This is due to the sudden
cooling of indoor air.
Is power plug inserted? Is there a po
wer failure?
Is fuse blown out?
25
Loading...