Indoor unit
Fix to side bar and lintel a mounting bar, Which is separately sold, and then
ƽ
fasten the plate to the xed mounting bar.
Refer to the previous article, “ When the mounting plate is
ƽ
position of wall hole.
Make a hole of 60 mm in diameter, slightly descending to outside the wall.
ƽ
Install piping hole cover and seal it off with putty after installation
ƽ
When the mounting plate is rst xed
1.Carryout,basedontheneighboringpillarsorlintels, a
to be xed against the wall, then temporarily fasten the plate with one steel nail.
2. Make sure once more the proper level of the plate, by
hanging a thread with a
weight from the central top of the plate, then fasten securely the plate with the
attachment steel nail.
3. Find the wall hole location A using a measuring tape
A=145mm
B= 60mm
30mm
When themountingplateisxedside barandlintel
FittingoftheMountingPlateand
PositioningofthewallHole
Lid for right
piping
Lid for under piping pipe
Fix with adhesive tape
Lid for left piping
Indoor/outdoor electric cable and drain hose must be bound with refrigerant
ƽ
piping by protecting tape.
[ Other direction piping ]
Cut away, with a nipper, the lid for piping according to the piping direction and
ƽ
then bend the pipe according to theposition of wall hole. When bending, be
careful not to crash
pipes.
Connect beforehand the indoor/outdoor electric cable,
ƽ
andthenpulloutthe
connected to the heat insulation of connecting part specially.
proper leveling for the plate
rst xed “, for the
Making a Hole on the Wall and Fitting the Piping Hole Cover
Drawingofpipe
Installation of the Indoor Unit
[Rearpiping ]
Drawpipesandthedrainhose,thenfastenthemwiththeadhesivetape
ƽ
[Left·Left-rear piping ]
In case of left side piping, cut away, with a nipper, the lid for left piping.
ƽ
In case of left-rear piping, bend the pipes according to the piping direction to
ƽ
the mark of hole for left-rear piping which is marked on heat insulation materials.
1. Insert the drain hose into the dent of heat insulation materials of indoor unit.
2.Inserttheindoor/outdoorelectriccablefrombackside of indoor
unit, and pull it
out on the front side, then connect them.
3.Coatthearingsealfacewithrefrigerantoilandconnect pipes.
Covertheconnectionpartwithheatinsulationmaterialsclosely,andmakesure
xingwithadhesivetape
Fixing the indoor unit body
Hang surely the unit body onto the upper notches of the
ƽ
mounting plate. Move the body from side to side to verify its
secure xing.
Inordertoxthebodyontothemountingplate,holdup
ƽ
thebodyaslantfromtheundersideandthenputitdown
perpendicularly.
Connectingtheindoor/outdoorElectricCable
Removingthewiringcover
Remove terminal cover at right bottom corner of indoor unit, then takeƽ
offwiringcoverbyremovingitsscrews.
1.Insertfromoutsidetheroomcableintoleftside of thewall
hole, in which the pipe has already existed.
2.Pulloutthecableonthefrontside,andconnectthecable
making a loop.
Note
When connecting the cable, conrm the terminal number of indoor and
outdoorunitscarefully.Ifwiringisnotcorrect,properoperationcannot
becarriedoutandwillcausedefect.
Insert the cable from the back
ƽ
side of the unit, then pull it out
on the front side.
Loosenthescrewsandinsert
ƽ
the cable ends fully into
terminal block, then
tighten the screws.
Pull the cable slightly to
ƽ
make sure the cables have
been properly inserted and
tightened.
Afterthecableconnection,
ƽ
neverfailtofastentheconnectedcablewiththe
wiring cover.
mounting plate
When connecting the cable after installing the indoor unit
When connecting the cable before installing the indoor unit
When you unload the indoor unit,please use
then lift the bottom of the body outward
slightly and lift the unit aslant until it
leaves the mounting plate.
agraffe
mounting plate
Unloading of indoor unit body
ƽ
your hand to arise the body to leave agraffe,
Remote controller (1)
R-03 dry battery (2)
Mounting plate (1)
Drainhose(1)
Ø4X25 Screw
(4)
Plastic cap (4)
Drain-elbow (1)
Cushion (4)
Pipe supporting plate (1)
Accessory parts
Liquid pipe (Ø) 6.35mm(1/4”)
Gas pipe (Ø) 9.52mm(3/8”)
NOTE˖Thethickness of thepipemustbe0.8mm at least.
Selection of pipe
2
Indoor side
Outdoor side
Ø60mm
Wall hole
Thickness of wall
(Section of wall hole)
Piping hole pipe
G
Heat insulation
material
Drain hose
Piping
Pipe supporting
plate
Indoor/outdoor electric cable
A=145mm
B=
60mm
Ø
30mm
A=80mm
B=
60mm
Ø
30mm