Haier HSU-09RS03/R2(SDB), HSU-12RS03/R2(SDB) Service Manual

SERVICE MANUAL
Order No.$&69
S -Series
© (Qingdao Haier Air Conditioner General corp.,Ltd)
All right reserved .Unauthorized copying and distribution is a violation of law
Haier Group
This service information is designed for experienced repair technicians only and is not designed for use by the general public. It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting to service a product. Products powered by electricity should be serviced or repaired only by experienced professional technicians. Any attempt to service or repair the product or products dealt with in this service information by anyone else could result in serious injury or death
WARNING
Wall mounted Type
DC Inverter
Model No.
HSU-09RS03/R2(SDB)
HSU-12RS03/R2(SDB)
13
13
40
40
40
24
52
66
70
72
73
Removal of Front Grill
9
9.1
9.2
9.3
78
75
Removal of Vertical Blades and Swing Motor
79
81
9.4
9.6
9.7
9.8
9.9
5.3
26
5.4
20
5.2
70
Removal of Filter and Blade
Removal of Front Panel
Main function and control specification of outdoor unit
HSU-09/12RS03/R2(SDB)
77
Main function and control specification of indoor unit
7. Service Diagnosis
Removal of Drain Pan
76
9.5
Removal of Display Assembly
Function of Main thermistor
91
91
92
94
11 Description of Coding Rules of Unit Model.................................................. 98
89
87
86
82
85
9.10
9.12 Removal of Fan and Fan motor
9.11
9.13
9.14
........................................................................
........................................................................
..............................................................
HSU-09/12RS03/R2(SDB)
Removal of Outdoor Panel
Removal of Fan Motor Bracket and Partition
Removal of Compressor and Heat Exchanger
Introduction
Domestic Air Conditioner
1 Introduction
1.1 Safety Cautions
Be sure to read the following safety cautions before conducting repair work.
The caution items are classified into “Warning” and “Caution”. The “Warning” items are especially important
since they can lead to death or serious injury if they are not followed closely. The “Caution” items can also lead
to serious accidents under some conditions if they are not followed. Therefore, be sure to observe all the safety
caution items described below.
About the pictograms
This symbol indicates an item for which caution must be exercised.
The pictogram shows the item to which attention must be paid.
This symbol indicates a prohibited action.
The prohibited item or action is shown inside or near the symbol.
This symbol indicates an action that must be taken, or an instruction.
The instruction is shown inside or near the symbol.
After the repair work is complete, be sure to conduct a test operation to ensure that the equipment operates
normally, and explain the cautions for operating the product to the customer.
1.1.1 Caution in Repair
Warning
Be sure to disconnect the power cable plug from the plug socket before disassembling the equipment for
arepair.
Working on the equipment that is connected to a power supply can cause an electrical shook.
If it is necessary to supply power to the equipment to conduct the repair or inspecting the circuits, do not
touch any electrically charged sections of the equipment.
If the refrigerant gas discharges during the repair work, do not touch the discharging refrigerant gas.The
refrigerant gas can cause frostbite.
When disconnecting the suction or discharge pipe of the compressor at the welded section, release the
refrigerant gas completely at a well-ventilated place first.
If there is a gas remaining inside the compressor, the refrigerant gas or refrigerating machine oil
discharges when the pipe is disconnected, and it can cause injury.
If the refrigerant gas leaks during the repair work, ventilate the area. The refrigerant gas can generate
toxic gases when it contacts flames.
The step-up capacitor supplies high-voltage electricity to the electrical components of the outdoor unit.
Be sure to discharge the capacitor completely before conducting repair work.A charged capacitor can
cause an electrical shock.
Do not start or stop the air conditioner operation by plugging or unplugging the power cable plug.
Plugging or unplugging the power cable plug to operate the equipment can cause an electrical shock or
fire.
1
HSU-09/12RS03/R2(SDB)
Introduction
Domestic Air Conditioner
Warning
Do not repair the electrical components with wet hands. Working on the equipment with wet hands can
cause an electrical shock.
Do not clean the air conditioner by splashing water. Washing the unit with water can cause an electrical
shock.
Be sure to provide the grounding when repairing the equipment in a humid or wet place, to avoid electrical
shocks.
Be sure to turn off the power switch and unplug the power cable when cleaning the equipment. The
internal fan rotates at a high speed, and cause injury.
Do not tilt the unit when removing it. The water inside the unit can spill and wet the furniture and floor.
Be sure to check that the refrigerating cycle section has cooled down sufficiently before conducting repair
work. Working on the unit when the refrigerating cycle section is hot can cause burns.
Use the welder in a well-ventilated place. Using the welder in an enclosed room can cause oxygen
deficiency.
1.1.2 Cautions Regarding Products after Repair
Warning
Be sure to use parts listed in the service parts list of the applicable model and appropriate tools to
conduct repair work. Never attempt to modify the equipment. The use of inappropriate parts or tools can
cause an electrical shock, excessive heat generation or fire.
When relocating the equipment, make sure that the new installation site has sufficient strength to
withstand the weight of the equipment.
If the installation site does not have sufficient strength and if the installation work is not conducted
securely, the equipment can fall and cause injury.
Be sure to install the product correctly by using the provided standard installation frame.
Incorrect use of the installation frame and improper installation can cause the equipment to fall, resulting
in injury.
For
integral
units only
Be sure to install the product securely in the installation frame mounted on a window frame.
If the unit is not securely mounted, it can fall and cause injury.
For
integral
units only
2
HSU-09/12RS03/R2(SDB)
Introduction
Domestic Air Conditioner
Warning
Be sure to use an exclusive power circuit for the equipment, and follow the technical standards related to
the electrical equipment, the internal wiring regulations and the instruction manual for installation when
conducting electrical work.
Insufficient power circuit capacity and improper electrical work can cause an electrical shock or fire.
Be sure to use the specified cable to connect between the indoor and outdoor units. Make the
connections securely and route the cable properly so that there is no force pulling the cable at the
connection terminals.
Improper connections can cause excessive heat generation or fire.
When connecting the cable between the indoor and outdoor units, make sure that the terminal cover does
not lift off or dismount because of the cable.
If the cover is not mounted properly, the terminal connection section can cause an electrical shock,
excessive heat generation or fire.
Do not damage or modify the power cable.
Damaged or modified power cable can cause an electrical shock or fire. Placing heavy items on the
power cable, and heating or pulling the power cable can damage the cable.
Do not mix air or gas other than the specified refrigerant (R-410A / R22) in the refrigerant system.
If air enters the refrigerating system, an excessively high pressure results, causing equipment damage
and injury.
If the refrigerant gas leaks, be sure to locate the leak and repair it before charging the refrigerant. After
charging refrigerant, make sure that there is no refrigerant leak.
If the leak cannot be located and the repair work must be stopped, be sure to perform pump-down and
close the service valve, to prevent the refrigerant gas from leaking into the room. The refrigerant gas itself
is harmless, but it can generate toxic gases when it contacts flames, such as fan and other heaters,
stoves and ranges.
When replacing the coin battery in the remote controller, be sure to disposed of the old battery to prevent
children from swallowing it.
If a child swallows the coin battery, see a doctor immediately.
3
HSU-09/12RS03/R2(SDB)
Introduction
Domestic Air Conditioner
1.1.3 Inspection after Repair
Warning
Check to make sure that the power cable plug is not dirty or loose, then insert the plug into a power outlet
all the way.
If the plug has dust or loose connection, it can cause an electrical shock or fire.
If the power cable and lead wires have scratches or deteriorated, be sure to replace them.
Damaged cable and wires can cause an electrical shock, excessive heat generation or fire.
Warning
Do not use a joined power cable or extension cable, or share the same power outlet with other electrical
appliances, since it can cause an electrical shock, excessive heat generation or fire.
Caution
Installation of a leakage breaker is necessary in some cases depending on the conditions of the
installation site, to prevent electrical shocks.
Do not install the equipment in a place where there is a possibility of combustible gas leaks.
If a combustible gas leaks and remains around the unit, it can cause a fire.
Be sure to install the packing and seal on the installation frame properly. If the packing and seal are not
installed properly, water can enter the room and wet the furniture and floor.
For
integral
units only
4
HSU-09/12RS03/R2(SDB)
Introduction
Domestic Air Conditioner
Caution
Check to see if the parts and wires are mounted and connected properly, and if the connections at the
soldered or crimped terminals are secure. Improper installation and connections can cause excessive
heat generation, fire or an electrical shock.
If the installation platform or frame has corroded, replace it. Corroded installation platform or frame can
cause the unit to fall, resulting in injury.
Check the grounding, and repair it if the equipment is not properly grounded. Improper grounding can
cause an electrical shock.
Be sure to measure the insulation resistance after the repair, and make sure that the resistance is 1 M
ohm or higher.
Faulty insulation can cause an electrical shock.
Be sure to check the drainage of the indoor unit after the repair.
Faulty drainage can cause the water to enter the room and wet the furniture and floor.
5
HSU-09/12RS03/R2(SDB)
HSU-09/12RS03/R2(SDB)
6
2 List of fuctions
N/YyrogetaC
Healthy negative ion
Make your room full of an abundance natural negative
ions
Y
Left&right flow
With specialized motor and flaps, the airflow can be adjusted .
Y
Child lock
Avoid the child's wrong operation on the remote
Y
3D air flow
The 3D airflow is able to deliver the airflow horizontally and vertically.
Y
24Hour timer
Use the timer function to set on,or off,or from on to off,or from off to on
Y
Auto restart
Automatic return to previous operation conditions after asundden power blackout
Y
Easy clean design
The panel is easy to wash and the airflow vents can be detached easily
Y
Intelligent air
With twin-blade technology ,the airflow can be adjusted not to blow directly
Y
Anti-mold filter
Catches most small particles and remove unpleasant odors effectively.
Y
Sleep mode
The setting temprature and the indoor noise can be adjusted to a more comfortable level when you set the "sleep mode"during night sleep
Y
YOTUA,IH,DEM,OLdeepsnafehttcelSgnittesnaF4
Entire auto mode
When air-con is in auto mode, it decides the running mode according to temperature difference between setting temperature and indoor temperature.
Y
ESF filter Trap harmful dust and remove unpleasant odors effectivel
yY
Ygnitaehrogniloo
ckciuQedomrewoP
YnoitidnocnoitarepoesionrewoLedomtfoS
Y.retlifehtybsnoievitagenetareneGretlifnoievitage
N
human perceptible
By detecting number and location of people indoor, airflow, air speed and temperature can be adjusted
automatically
Y
Hidden Display
When the air-con is off, you can't see the display screen, which looks like part of the panel.
Y
electric deicer
Automatically clean ice on outdoor unit and make the unit work normally.
Y
10ć control
Indoor temperature can be controlled at 10ć by pressing the 10ć button when leaving room.
Y
Note: Y: Holding Functions
N : No Functions
Functions
11250(3050~20450)
9200(2350~13650)
5
20(160~1100) 630(180-1710)
5.19 5.24
4.57
-
-
--
0.15
0.15
0.15
0.15
40
40
40
40
3.3(0.9 ~6.0)
12.5.
14.5
4
4
2322(602~3440)
7
2.6
3.2
830
(160~1460) 920(180
~2030)
3.7
4.2
1.2
10
10
10
10
5151
0202
390X888X335
2838(774~5160)
14300
(2050~22150)
12000(2350~15000)
4.2
(0.9~6.5)
3.5(0.7~4.4)
3010(602
~3784) 3612
(774~5590)
4.22
1.6
9.52
9.52
298x800X243
390X888X335
298x800X243
12.5
14.5
37/25/23
36/24/22
47
46
HSU-09/12RS03/R2(SDB)
HSU-09RS03/R2(SDB) HSU-12RS03/R2(SDB)
2.7(0.7~4.0)
87 86
95
11.7
10.4
9.2
12.7
11.4
10.2
11.7
10.4
9.2
12.7
11.4
10.2
3 Specifications
98
LSL
0.50.5
R410aR410a
1.15
33.3
1175.5 1175.5 1175.5 1175.5
33.3
33.3
33.3
36.5
33.5
36.5
33.5
47
783X255643X
714X930X340
783X255643X
714X930X340
830 920
3.7
4.2
47
8.0
52
52
5
7
57
48
48
58 58
900
5
HSU-09/12RS03/R2(SDB)
SNB130FGYM2 SNB130FGYM2
HSU-09RS03/R2(SDB) HSU-12RS03/R2(SDB)
1.15
900
2.6
3.2
520 630
8.0
8
FV50S FV50S
9
Domestic air conditioner
HSU-09/12RS03/R2(SDB)
Connector Wring Diagram
3ULQWHG&LUFXLW%RDUG&RQQHFWRU:LULQJ'LDJUDP
4.1Indoor unit Connectors
Connectors
PCB(1) (Control PCB) PCBď
1Đďcontrol PCBĐ
1) CN12,CN13 connector for L&R step motor
2) CN11 connector for Up&down step motor
3) CN26 connector for DC fan motor
4) CON7 connector for communication line between the indoor and outdoor
5) CN1 connector for ambient temp. sensor and piping temp. sensor
6) CH1 connector for power L wire
7) CON12 connector for L in terminal block
8) CON2 connector for N in terminal block
8) CN32 connector for display board
9) CON6 CON8 connector for ions generator
Note: Other designations
PCB(1) (INdoor Control PCB)
1) CN48 Connector for Forced operation ON / OFF switch
2) J1 Select 25 or 35
3) RV1 Varistor
4) FUSE1 Fuse 3.15A/250VAC
PCB1
CN11 CN26 CN13
CN48
CN32 CN12
CN1
CON7 CON6
CON8
CH1
CON2
CON12
10
Domestic air conditioner
HSU-09/12RS03/R2(SDB)
Connector Wring Diagram
4.2: outdoor unit
Connectors
PCB(1) (Control PCB)
1) CN1ǃCN2 Connector for power N and L
2) CN3 Connector for ground
3) CN22 Connector for DC POWER 15V and 5V to the module board
4) CN22ǃCN23 Connector for CN10,CN11 on the module board
5) CN21 Connector for fan motor
6) CN10 Connector for four way valve coil
7) CN17ǃCN18ǃCN19ǃCN20 Connector for thermistors
8) CN23 Connector for communicate between the control board and the module board
9) CN26ǃCN24 Connector to P and N of the module board
10) CN4 Connector for communicate between indoor and outdoor unit
11) CN16 Connector for electric expansion valves
12) CN9ǃCN8 Connector to L and N of the module board
PCB(2) (module PCB)
CN10 Connector for the DC power 5V and 15V form the control PCB
CN11 Connector for communicate between the control board and the module board
P( CN1), N(CN5) Connector for capacitance board
LI (CN7),LO(CN6) Connector for reactor
Note: Other Designations
PCB(1) (Control PCB)
1) FUSE 1, (25A,250VAC) FUSE 2(1A,250VAC)
2)LED 1 keep light representative normal ,if keep flash interval representative trouble Alarm
3)RV1,RV2,RV3 Varistor
HSU-09/12RS03/R2(SDB)

Connector Wring Diagram
Domestic Air Conditioner
11
PCB(1)
CN2
CN1
CN3
CN26 CN24
CN4
CN23
CN22
CN21
CN17
CN18
CN19
CN20
CN10
CN9
CN8
CN16
12
Domestic air conditioner
HSU-09/12RS03/R2(SDB)
Connector Wring Diagram
PCB(2)
CN6 CN7
CN11
CN10
CN5
CN1
13
Domestic air conditioner
HSU-09/12RS03/R2(SDB)
Function and control
5.Funcitions and Control
5.1 Main functions and control specification of indoor unit
This specification use for HSU-09/12RS03/R2(SDB) frequency conversion air condition are
manufactured by Haier air condition parent company. "Setting value" (express in parameter) in
this specification means is a parameter that is stored in EEPROM. Refer to [EEPROM parameter
table].
5.1.1 Temperature Adjusting function
5.1.1.1 Temperature adjusting of different levels.
(DASH operation conditions under different modes)
5.1.1.2 Select the wind volume when it is set automatic
When the wind volume is automatic, it can be switched between strong, medium and weak according
to the temperature adjusting levels.
Wind volume under the automatic wind volume mode
Temperature adjusting levels
A B C D E F G H I
Heating
Strong Strong Strong Strong Strong Medium Weak Weak SLO
cooling
Strong Strong Strong Medium Medium Weak Weak Weak
Moisture
removing
Strong Medium Medium Medium Weak Weak SLO SLO
&22/

 



+($7'$6+


%





0,187(63527(&7,21
&22/'$6+
'5<'$6+
7
 







 

&20367$576$*$,1
(
*
)
+
'
&




  

 

&22/'5< +($7
(
%/2&.
$
+($7

'5<
V
HSU-09/12RS03/R2(SDB)

Function and control
Domestic Air Conditioner
14
5.1.1.3 Wind volume limit
When the compressor is working and the max setting for indoor fan motor is medium or weak, the
upper limit of indicated frequency is as follows:
Frequency control form for wind volume in cooling mode
Limited frequency
variables
Limited frequency
Medium wind volume FQLIMMD 40Hz
Weak wind volume FQLIMLO 36Hz
Limited frequency for
up/down health wind
FUPHEAL 80Hz
5.1.2 Main functions
5.1.2.1 Warm boot
When the heat running starts or the frost removing ends and the compressor starts again, in order to
avoid cold wind, warm boot wind volume control should be done.
Heat exchange temperature
THHOT337ć˅
THHOT235ć
THHOT125ć
THHOTR23ć˅
4 minutes
Stop weak setting weak stop
To control the indoor fan motor as shown in the table above according to the heat exchange
temperature The fan motor stops when the heat exchange temperature is below 25ć The fan motor is working slightly weak when the heat exchange temperature is above25 ć and below 35ć The fan motor is working weak when the heat exchange temperature is above35 ć and below 37ć
The fan motor works as set if the he heat exchange temperature remains above 38ć
slightly
weak
slightly
weak
15
Domestic air conditioner
HSU-09/12RS03/R2(SDB)
Function and control
5.1.2.2 When the compressor stops and remains idle for 3 minutes
1. Turn off the air conditioner by remote control; the indoor fan stops operation.
2. The temperature sensing device stops running and the indoor fan operates under wind mode.
3. When the air conditioner turns to the heating mode from other modes and the compressor fails to
start, the indoor fan will operate under wind mode.
5.1.2.3 Dehumidification running
Under the dehumidification mode the fan motor stops as the compressor stops
The operation is weak after 3 minutes’ idle mode
After stand by for 3 minutes, the compressor is on.
The compressor operates as the set wind volume when the wind volume is set to be strong, medium
or weak
The wind volume is decided according to the temperature adjusting when the wind volume is set to be
automatic.
Moisture removing running
Level H 3minutes idle mode
Compressor
OFF
Setting slightly OFF weak weak setting
weak
5.1.2.4 Automatic running
When the running mode is turned to automation after starting the system, the system will first
determine the running mode according to the current room temperature and then will run according to
the determined mode. Tr in the following selection conditions means room temperature, Ts means
setting temperature, Tp means temperature of indoor coil pipe Tr23 Choose Cooling Modeć Tr˘23 Choose Heating Modeć
After turning to the automation mode, the running mode can be switched between cooling mode, fan
mode and heating mode according to the change of the indoor ambient temperature. But the
automatic conversion between cooling mode and heating mode must be conducted after 15 minutes.
5.1.3 Special functions
5.1.3.1 Powerful running
The mode switch ends the powerful running
Enter into the silent mode, normal running mode or timed switching on mode to end the powerful
running
When in automatic mode, there are powerful and silent functions for your choice. When the main unit
is in cooling mode, it operates with powerful cooling or silent cooling. When the main unit is in heating
mode, it operates with powerful heating or silent heating. When the main unit is in wind-sending mode,
16
Domestic air conditioner
HSU-09/12RS03/R2(SDB)
Function and control
there are no powerful or silent modes.
There is no powerful mode for wind-sending and moisture removing
Powerful heating˖
Change the set temperature. With temperature adjusting function
The wind volume is the automatic medium
When in frost removing mode, the outdoor unit does not accept the communication signal for powerful
running
Powerful cooling˖
Change the set temperature. With temperature adjusting function
The wind volume is the automatic strong
After the compressor starts, there will be no low-intense running protection within 3 minutes
5.1.3.2 Silent running
Send the silent running signal to the outdoor unit
Under the Silent hearing mode,The wind volume is SSLO after the compressor is on,The wind volume
will be kept SSLO within 20 seconds after the compressor stops and then changes to weak
Under the Silent cooling mode the wind volume is SSLO
There is no silent mode for moisture removing and wind-sending.
5.1.3.3 Air cleaning
If the fan motor starts working after receiving the remote-control order, the aion generator starts
working and sends out ions.
The ion generator stops as the fan motor stops.
When the ion generator is OFF and the air cleaning function is on, the fan motor starts running and
the ion generator starts working again.
5.1.3.4 Timed running
Set the time duration according to the time difference between the clock for
timing and the current clock
In timing mode, the display panel will flash the light at fixed times
Timed When this function is set, operation modes on the panel display will not
OFF change. The timing icon will show and the operation stops when the set time comes.
Timed When this function is on, the panel display will only display a question mark.
ON The unit will operate as the set mode when the time comes.
Timed The unit will start operating or stop according to the order of your setting.
ON/OFF
17
Domestic air conditioner
HSU-09/12RS03/R2(SDB)
Function and control
5.1.3.5 Sleeping function
a.After setting the sleeping function, the refrigerating mode and dehumidification mode will run as per
the following rules:
1 hour 1 hour 6hours
T()
Ts+2
Ts+1
Ts Sleep OFF t(hour)
b.After setting the sleeping function, the heating mode will run as per the following rules:
T() 1 hour 1 hour 3hours 3hours
Ts
Ts-2
Ts-4
Ts-5
Ts Sleep OFF t(hour)
As shown in the above diagram, after running for 1 hour under refrigerating mode and
dehumidification mode, the setting temperature will increase about1
; after another 1 hour, it will
increase about1
again, and after 6 hours, it will cease; after running for 1 hour under heating
mode, the setting temperature will decrease about2
, after another 1 hour, it will decrease the
about 2
again, and after 3 hours, it will increase about 1 , and after other 3 hours, it will cease.ć
5.1.3.6 Trial running
The indicated frequency for trial running is 58Hz, wind volume is strong.
The trial running will last for 30 minutes and then the unit will be powered off. The unit will exit the trial
running if it receives any remote-control signal during the trial running period.
There is no low-intense running protection.
5.1.3.7 Power failure compensation
To enter into the function please press the sleep key 10 times with 4 beeps in 7 seconds
Under the power failure compensation mode, unplug and plug again ,the indoor unit will resume
original operation
Under the power failure compensation mode, unplug and plug again, the unit will be on OFF state.
Mode, Fan speed, Healthy, Set temperature can be memoried. Swing, Timer, Sleep cannot be
memoried
Press the sleep key for 10 times with 2 beeps in 7 seconds to exit.
HSU-09/12RS03/R2(SDB)

Function and control
Domestic Air Conditioner
18
5.1.3.8 Rated Operation
Rated Cooling:
When receiving the instruction of indoor unit rated operation, the unit will start rated cooling operation.
Rated Heating:
When receiving the instruction of indoor unit rated operation, the unit will start rated heating operation.
5.1.3.9 IFP ˄Optional Function
˅
Press the remote control to select and enter the human perception mode; the panel will display the
human perception symbol. Two wind velocity modes are available: fixed velocity and adjustable
velocity. The specific options and control functions are as follows:
Judge the position of the human being to have air flow control.
Follow or Avoid may be set by the remote controller. When signals are detected for 10 seconds
continuously in any area, humans are determined to be in the area and the air conditioner will enter
auto control.
(1) When signals are detected in a certain zone: ķ Wind direction following  Detect the area where human beings are and adjust the deflector to
blow conditioned air towards the human body;
When humans are detected in Zone A: See Position 4
When humans are detected in Zone C: See Position 7.
ĸ Wind direction avoiding  Detect the area where human beings are and adjust the deflector to
blow air away from the human body.
When humans are detected in Zone A: See Position 6
When humans are detected in Zone C: See Position 5.
(2) When humans are detected in both areas: