Haier HSU-09RK03/R2, HSU-12RK03/R2 User Manual

Installation Manual of Room Air Conditioner
Preparation
Necessary Tools for Installation
Torque wrench
Driver Nipper Hacksaw Pipe cutter Hole core drill Flaring tool Spanner(17,19 and 26mm) Knife Gas leakage detector or soap-and-water solution
(17mm,22mm,26mm)
Measuring tape Reamer
Power Source
Before inserting power plug into receptacle, check the voltage without fail. The power
Install an exclusive branch circuit of the power.
A receptacle shall be set up in a distance where the power cable can be
reached.
source is the same as the
Do not extend the cable by cut ting it.
corresponding name plate.
Drawing for the installation of indoor and outdoor units
The models adopt HFC free refrigerant R410A
more than 5cm
more than 10cm
Indoor Unit
Place, robust not causing vibration, where the body can be supported sufciently. Place, not affected by heat or steam generated in the vicinity, where inlet and outlet of the
unit are not disturbed. Place, possible to drain easily, where piping can be connected with the outdoor unit. Place, where cold air can be spread in a room entirely. Place, nearby a power receptacle, with enough space around. (Refer to drawings). Place where the distance of more than lm from televisions, radios, wireless apparatuses
and uorescent lamps can be left. In the case of xing the remote controller on a wall, place where the indoor unit can
receive signals when the uorescent
Outdoor Unit
Place, which is less af fected by rain or direct sunlight and is sufciently ventilated. Place, possible to bear the unit, where vibration and noise are not increased. Place, where discharged wind and noise do not cause a nuisance to the neighbors. Place, where a distance marked
Attention must be paid to
the rising up of drain hose
G
Selection of Installation Place
lamps in the room are lightened.
is available as illustrated in the above gure.
Optional parts for piping
Non-adhesive tape
A
Adhesive tape
B
Saddle (L.S) with screws
C
Connecting electric cable
D
for indoor and outdoor
E
Drain hose
F
Heating insulating material
Piping hole cover
G
Arrangement of piping directions
Rear left
Left
Below
The marks from to
G
in the gure are the
parts numbers. The distance between
the indoor unit and the oor should be more than 2m.
A
Rear right
Right
more than 10cm
more than 60cm
more than 10cm
more than 10cm
more than15cm
F
A
C
Floor xing dimensions of the
outdoor unit (Unit:mm)
106.5
566
106.5
7 31
Fixing of outdoor unit
Fix the unit to concrete or block with bolts (10mm) and nuts rmly
and horizontally. When tting the unit to wall surface, roof or rooftop, x
D
E
a supporter surely with nails
or wires in consideration of
earthquake and strong wind. If vibration may affect the house, x the unit by attaching a
vibration-proof mat.
Please be subject to the actual product purchased , the above picture is just for your reference.
Read this manual before installation Explain sufciently the operating means to the user according to this manual.
NO.0010519573
Accessory parts
Remote controller (1)
R-03 dry battery (2)
Mounting plate (1)
Plastic cap (4)
Ø4X25 Screw
(4)
Drain hose (1)
Cushion (4)
Drain-elbow (1)
Pipe supporting plate (1)
Selection of pipe
Liquid pipe (Ø) 6.35mm(1/4”)
Gas pipe (Ø) 9.52mm(3/8”)
NOTEThe thickness of the pipe must be 0.8mm at least.
Indoor unit
1
Fitting of the Mounting Plate and
When the mounting plate is rst xed
1. Carry out, based on the neighboring pillars or lintels, a
to be xed against the wall, then temporarily fasten the plate with one steel nail.
2. Make sure once more the proper level of the plate, by weight from the central top of the plate, then fasten securely the plate with the attachment steel nail.
3. Find the wall hole location A using a measuring tape
Positioning of the wall Hole
proper leveling for the plate
hanging a thread with a
B= 60mm
3
Installation of the Indoor Unit
Drawing of pipe
[ Rear piping ]
Draw pipes and the drain hose, then fasten them with the adhesive tape
[ Left·Left-rear piping ]
In case of left side piping, cut away, with a nipper, the lid for left piping. In case of left-rear piping, bend the pipes according to the piping direction to
the mark of hole for lef t-rear piping which is marked on heat insulation materials.
1. Insert the drain hose into the dent of heat insulation materials of indoor unit.
2. Insert the indoor/outdoor electric cable from backside of indoor out on the front side, then connect them.
3. Coat the aring seal face with refrigerant oil and connect pipes.
Cover the connection part with heat insulation materials closely, and make sure
xing with adhesive tape
Heat insulation
Lid for right piping
Lid for under piping pipe
Fix with adhesive tape
Indoor/outdoor electric cable and drain hose must be bound with refrigerant
piping by protecting tape.
Lid for left piping
material
Drain hose
unit, and pull it
Indoor/outdoor electric c able
Piping
Pipe supporting plate
[ Other direction piping ]
Cut away, with a nipper, the lid for piping according to the piping direction and
then bend the pipe acc ording to theposition of wall hole. When bending, be
careful not to crash
Connect beforehand the indoor/outdoor electric cable,
connected to the heat insulation of connecting part specially.
pipes.
and then pull out the
A=145mm
60mm
Ø
B=
A=145mm
Ø
60mm
B=
A=135mm
Ø
60mm
B=
A=135mm
When the mounting plate is xed side bar and lintel
Fix to side bar and lintel a mounting bar, Which is separately sold, and then
fasten the plate to the xed mounting bar.
Refer to the previous article, “ When the mounting plate is
position of wall hole.
2
Making a Hole on the Wall and Fitting the Piping Hole Cover
Make a hole of 60 mm in diameter, slightly descending to outside the wall.
Install piping hole cover and seal it of f with putty af ter installation
Wall hole
Ø60mm
Indoor side
(Section of wall hole)
Thickness of wall
Piping hole pipe
G
rst xed “, for the
Outdoor side
30mm
30mm
30mm
30mm
Fixing the indoor unit body
Hang surely the unit body onto the upper notches of the
mounting plate. Move the body from side to side to verify its secure xing.
In order to x the body onto the mounting plate,hold up
the body aslant from the underside and then put it down perpendicularly.
Unloading of indoor unit body
When you unload the indoor unit,please use
your hand to arise the body to leave agraffe,
then lift the bottom of the body outward slightly and lift the unit aslant until it leaves the mounting plate.
agraffe
4
Connecting the indoor/outdoor Electric Cable
Removing the wiring cover
Remove terminal cover at right bot tom corner of indoor unit, then take
off wiring cover by removing its screws.
When connecting the cable after installing the indoor unit
1. Insert from outside the room cable into lef t side of the wall hole, in which the pipe has already existed.
2. Pull out the cable on the front side, and connect the cable
making a loop.
When connecting the cable before installing the indoor unit
Insert the cable from the back
Loosen the screws and insert
tighten the screws.
Pull the cable slightly to
tightened.
side of the unit, then pull it out the cable ends fully into
make sure the cables have
been properly inserted and
mounting plate
mounting plate
on the front side.