Haier HSU-12RK03, HSU-09RK03/R2(SDB), HSU-12RK03/R2(SDB), HSU-12HQA03/R2(DB) Installation Manual

Drawing for the installation of indoor and outdoor units
Necessary Tools for Installation
Driver
Torque wrench
(17mm,22mm,26mm)
Nipper
Reamer
Gas leakage detector or soap-and-water solution
Hole core drill Flaring tool Spanner(17,19 and 26mm) Knife
Measuring tape
Indoor Unit
Place, robust not causing vibration, where the body can be supported sufciently. Place, not affected by heat or steam generated in the vicinity, where inlet and outlet of the unit are not disturbed.
Place, possible to drain easily, where piping can be connected with the outdoor unit. Place, where cold air can be spread in a room entirely. Place, nearby a power receptacle, with enough space around. (Refer to drawings). Place where the distance of more than lm from televisions, radios, wireless apparatuses and uorescent lamps can be left.
In the case of xing the remote controller on a wall, place where the indoor unit can receive signals when the uorescent
lamps in the room are lightened.
Outdoor Unit
Place, which is less af fected by rain or direct sunlight and is sufciently ventilated. Place, possible to bear the unit, where vibration and noise are not increased. Place, where discharged wind and noise do not cause a nuisance to the neighbors. Place, where a distance marked
is available as illustrated in the above gure.
Before inserting power plug into receptacle, check the voltage without fail. The power
source is the same as the
corresponding name plate.
Install an exclusive branch circuit of the power.
A receptacle shall be set up in a distance where the power cable can be reached.
Do not extend the cable by cut ting it.
Power Source
Preparation
Please be subject to the actual product purchased , the above picture is just for your reference.
Read this manual before installation Explain sufciently the operating means to the user according to this manual.
NO.0010519573
Installation Manual of Room Air Conditioner
F
A
C
E
D
Optional parts for piping
Non-adhesive tape
Adhesive tape
Saddle (L.S) with screws
Connecting electric cable
for indoor and outdoor
Drain hose
Heating insulating material
Piping hole cover
Floor xing dimensions of the
outdoor unit (Unit:mm)
Fixing of outdoor unit
Fix the unit to concrete or block with bolts (10mm) and nuts rmly
and horizontally. When tting the unit to wall surface, roof or rooftop, x
a supporter surely with nails
or wires in consideration of
earthquake and strong wind. If vibration may affect the house, x the unit by attaching a
vibration-proof mat.
The marks from to
in the gure are the
parts numbers. The distance between the indoor unit and the oor should be more than 2m.
The models adopt HFC free refrigerant R410A
more than 10cm
more than 5cm
more than 10cm
more than 10cm
more than 10cm
more than15cm
more than 60cm
A
G
106.5
106.5
566
31
7
A
F
C
E
D
G
B
Arrangement of piping directions
Rear left
Left
Rear right
Right
Below
G
Attention must be paid to
the rising up of drain hose
Selection of Installation Place
Indoor unit
Fix to side bar and lintel a mounting bar, Which is separately sold, and then
fasten the plate to the xed mounting bar.
Refer to the previous article, “ When the mounting plate is
position of wall hole.
Make a hole of 60 mm in diameter, slightly descending to outside the wall.
Install piping hole cover and seal it of f with putty af ter installation
When the mounting plate is rst xed
1. Carry out, based on the neighboring pillars or lintels, a
to be xed against the wall, then temporarily fasten the plate with one steel nail.
2. Make sure once more the proper level of the plate, by
hanging a thread with a weight from the central top of the plate, then fasten securely the plate with the attachment steel nail.
3. Find the wall hole location A using a measuring tape
A=145mm
B= 60mm
30mm
When the mounting plate is xed side bar and lintel
1
Fitting of the Mounting Plate and
Positioning of the wall Hole
Lid for right piping
Lid for under piping pipe
Fix with adhesive tape
Lid for left piping
Indoor/outdoor electric cable and drain hose must be bound with refrigerant
piping by protecting tape.
[ Other direction piping ]
Cut away, with a nipper, the lid for piping according to the piping direction and
then bend the pipe acc ording to theposition of wall hole. When bending, be
careful not to crash
pipes.
Connect beforehand the indoor/outdoor electric cable,
and then pull out the
connected to the heat insulation of c onnecting par t specially.
proper leveling for the plate
rst xed “, for the
2
Making a Hole on the Wall and Fitting the Piping Hole Cover
Drawing of pipe
3
Installation of the Indoor Unit
[ Rear piping ]
Draw pipes and the drain hose, then fasten them with the adhesive tape
[ Left·Left-rear piping ]
In case of left side piping, cut away, with a nipper, the lid for left piping.
In case of left-rear piping, bend the pipes according to the piping direction to
the mark of hole for lef t-rear piping which is marked on heat insulation materials.
1. Insert the drain hose into the dent of heat insulation materials of indoor unit.
2. Insert the indoor/outdoor electric cable from backside of indoor
unit, and pull it
out on the front side, then connect them.
3. Coat the aring seal face with refrigerant oil and connect pipes.
Cover the connection part with heat insulation materials closely, and make sure
xing with adhesive tape
Fixing the indoor unit body
Hang surely the unit body onto the upper notches of the
mounting plate. Move the body from side to side to verify its secure xing.
In order to x the body onto the mounting plate,hold up
the body aslant from the underside and then put it down perpendicularly.
4
Connecting the indoor/outdoor Electric Cable
Removing the wiring cover
Remove terminal cover at right bot tom corner of indoor unit, then take
off wiring cover by removing its screws.
1. Insert from outside the room cable into lef t side of the wall hole, in which the pipe has already existed.
2. Pull out the cable on the front side, and connect the cable
making a loop.
Insert the cable from the back
side of the unit, then pull it out
on the front side.
Loosen the screws and insert
the cable ends fully into
terminal block, then
tighten the screws.
Pull the cable slightly to
make sure the cables have
been properly inserted and
tightened.
mounting plate
When connecting the cable after installing the indoor unit
When connecting the cable before installing the indoor unit
When you unload the indoor unit,please use
then lift the bottom of the body outward slightly and lift the unit aslant until it leaves the mounting plate.
agraffe
mounting plate
Unloading of indoor unit body
your hand to arise the body to leave agraffe,
Remote controller (1)
R-03 dry battery (2)
Mounting plate (1)
Drain hose (1)
Ø4X25 Screw
(4)
Plastic cap (4)
Drain-elbow (1)
Cushion (4)
Pipe supporting plate (1)
Accessory parts
Liquid pipe (Ø) 6.35mm(1/4”)
Gas pipe (Ø) 9.52mm(3/8”)
NOTEThe thickness of the pipe must be 0.8mm at least.
Selection of pipe
2
Indoor side
Outdoor side
Ø60mm
Wall hole
Thickness of wall
(Section of wall hole)
Piping hole pipe
G
Heat insulation material
Drain hose
Piping
Pipe supporting plate
Indoor/outdoor electric c able
A=145mm
B=
60mm
Ø
30mm
A=135mm
B=
60mm
Ø
30mm
A=135mm
B=
60mm
Ø
30mm