Haier HSU-12LEA13-W user guide manual

SPLIT TYPE ROOM AIR CONDITIONER
OPERATION MANUAL
HSU-05LEA03 HSU-07LEA03 HSU-09LEA03 HSU-12LEA03 HSU-18LEA03 HSU-22LEA03 HSU-24LEA03 HSU-09LEA13-W HSU-10LEA03-T HSU-12LEA13-W HSU-18LEA13-W HSU-22LEA13-W HSU-13LEA03-T HSU-09LEB13-H HSU-14LEA13-H HSU-18CRA03-T HSU-12HEA03/(BP) HSU-09HEA03/(BP) HSU-09LEA13-H HSU-18HEA03(T3) HSU-18HEA13(T3) HSU-12CRA03-T HSU-12HEA03/(DB) HSU-09HEA03/(DB)
HSU-09LEA13-F HSU-12LEA13-H HSU-18LEA13-H HSU-12LEA13-F HSU-12LEA13-M HSU-18LEA13-M HSU-07HEA03 HSU-09HEA03 HSU-12HEA03 HSU-18HEA03 HSU-22HEA03 HSU-24HEA03 HSU-12LEB13-H HSU-14LEB13-H HSU-09CRA03-T AMS09H03-N AMS12H03-N AMS18H03-N AMS22H03-N PAS18L03-N(T3)
HSU-07HEA13-B HSU-09HEA13-B HSU-12HEA13-B HSU-18HEA13-B
HSU-18LEA03(T3) HSU-18LEA13(T3)
HSU-09CA2 HSU-12CA2 HSU-12CB2 HSU-18LB2 HSU-18LA2 HSU-24LA2 HSU-12HEB03
HEC-18LEA03(T3) HSU-09LM11 HSU-12LM11 HSU-07LEA13-B HSU-09LEA13-B
Contents
PARTS AND FUNCTIONS
OPERATION
MAINTENANCE
CAUTIONS
TROUBLE SHOOTING
1 2-4
5
6.7 7
Please read this operation manual before using the air conditioner.
Keep this operation manual for future reference.
0010515137
Parts and Functions
Parts and Functions
Indoor Unit
1
2
3
7
5
4
1
1
Inlet
2
2
Inlet grille
3
3
Air Purifying Filter (inside)
5
4
Outlet
Actual inlet grille may vary from the one shown in the manual according to the product purchased
8
Display board
3
1
1
Signal receiver hole
COOL display
2 3
HEAT display
Ambient temp.display
4
When receiving the remote control signal, display the set temperature and in the rest time the room temperature is displayed and this room temperature is only for reference.
2
5
Horizontal flap
(adjust up and down air flow Don't adjust it manually)
6
6
Vertical blade
(adjust left and right air flow)
7
Anion generator
4
5
HEALTH display
5
(If the unit which you purchased
has healthy function,follow it.
If not,please ignore.)
6
Dry display
TIMER OFF display
7
TIMER ON display SLEEP display
6
4
5
6
8
(inside)
7
Remote controller
7. SIGNAL SENDING display
8. TIMER OFF display
9. TIMER ON display
1
2 3 4
5
ON/OFF
12
13
14
15
16
17
18
Operation mode
Remote controller
MODE SET
FAN
SWING
SLEEP
LOCK RESET
1. Operation mode display
Display board
2. SWING display
3. FAN SPEED display
4. HEALTH display
5. SLEEP display
6. LOCK display
NOTE:
Cooling only unit do not have displays and functions related with heating
If the unit which you purchased has healthy function,follow it.If not,please ignore.
A U T O
HEALTH
AUTO
ON OFF
AM
o
PM
C
TEMP
TIMER
CLOCK
POWER/SOFT
COOLDRY
LO MED HIAUTO
HEAT
FAN
Loading of the battery
10. CLOCK display 1
1. TEMP display
6
12. POWER ON/OFF
7
8
13. MODE
9
10
14. FAN
26
11
19
20
21
22
25
24
23
Used to select fan speed LO, MED, HI, AUTO
(This function is unavailable on some models.)
15. HOUR
Used to set clock and timer setting.
16. SWING
Used to set auto fan direction.
17. SLEEP
Used to select sleep mode.
(This function is unavailable on some models.)
18. LOCK
Used to lock buttons and LCD
19. TEMP.
Used to select your desired temp.
20. SET
Used to confirm timer and clock settings.
21. TIMER
Used to select TIMER ON,
TIMER OFF,
22. CLOCK
Used to set correct time
23. RESET
Used to reset the controller back to normal condition.
24. HEALTH
Used to operate the healthy function
25.
POWER/SOFT button
This function is unavailable on some models.
26.
POWER/SOFT display
This function is unavailable on
some models.
Used for unit start and stop.
Used to select HEAT DRY and FAN operation
AUTO run, COOL,
TIMER ON-OFF
displa
y.
Outdoor Unit
OUTLET
INLET
Clock set
Press CLOCK button, "AM" or "PM" flashes. Press or to set correct time. Each press
or decrease 1min. If the
change quickly.
"AM "and "PM" stop flashing,while clock starts working.
MODE SET
FAN
SWING
After time setting is confirmed,press SET,
TIMER
CLOCK
CONNECTING PIPING AND ELECTRICAL WIRING
DRAIN HOSE
14
will increase
button is kept pressed,time will
Remove the battery cover;
1
2
3
Load the battery,then put on the cover again.
4
Load the batteries as
2
illustrated. 2 R-03 batteries,
1
resetting key(cylinder);
Be sure that the loading
3
is in line with th
e" + "/"-";
Note:
The distance between the signal transmission head and the receiver hole should be within 7m without any obstacle as well.
When electronic-started type fluorescent lamp or change-over wireless telephone is installed in the type fluorescent lamp or room, the receiver is apt to be disturbed in receivingthe signals,
so the distance to the indoor unit should be shorter.
Full display or unclear display during operation indicates the
ries have been used up.
batte
Please change batteries.
If the remote controller can't run normally during operation,
please
remove the batteries and
reload several minutes later.
Hint:
Remove the batteries in case unit won't be in usage for a long period.
If there are any display
after taking-out, just need to press reset key
1
Operation
Unit start / stop
Press ON/OFF button, unit starts or stops.
Operation Mode
AUTO
COOL
DRY
HEAT
FAN
O
ON/OFF
TEMP
MODE SET
Select temp.setting
Display Board
nothing
Remote Controller
ON/OFF
Under the mode of auto operation, air conditioner will automatically select Cool or Heat operation according to room temperature. air conditioner according to room
In DRY mode, when room temperature becomes lower than temp.setting+2 at LOW speed regardless of FAN setting.
In FAN operation mode, the unit will not operate in COOL or HEAT mode but only in FAN mode ,AUTO is not available in FAN mode.And temp.setting is disabled. In FAN mode,SLEEP operation is not available.
TEMP
MODE SET
Note
When FAN is set to AUTO, the
automatically adjusts the fan speed
temperature.
o
C,unit will run intermittently
Cool Operation
Auto Operation
According to the automatic choice system in temperature in indoors
cold or make the hot movement
ON/OFF
TEMP
MODE SET
Dry Operation
ON/OFF
Note:
In DRY mode, when room temperature becomes lower than temp. setting+2 C, unit will run intermittently at LOW speed regardless
of FAN setting.
TEMP
MODE SET
o
ON/OFF
TEMP
MODE SET
Heat Operation
ON/OFF
Note:
In HEAT mode,warm air will blow out after a short periodof the time
due to cold-draft prevention function.
When FAN is set to AUTO, the air conditioner automatically adjusts
the fan speed according to room temperature.
Cooling only unit do not have displays and functions related with heating
TEMP
MODE SET
Fan Operation
(This function is unavailable on some models.)
1.
When FAN is set to AUTO,
the air conditioner automatically adjusts
the fan speed according
to room
2.In FAN operation mode
temperature.
the unit will not operate in COOL mode but only in FAN mode ,AUTO is not available in FAN mode.And temp.setting is disabled.
AUTO LO MED HI
MODE SET
FAN
SWING
TIMER
CLOCK
Air Flow Direction Adjustm
(1)
FAN
SWING
SLEEP HEALTH
Remote controller can memorize each operation status. When starting it next time,just press ON/OFF button and unit will run in previous status.
TIMER
CLOCK
2
HEALTH Operation
(This function is unavailable on some models.)
Healthy Negative ions
To cancel TIMER mode
Just press TIMER button several times untilTIMER mode disappears.
The anion generator in the airconditioner can generate a lot of
the air and
also to kill bacteria and speed up the dust sediment
anion effectively balance the
quantity of position and anion in
in the room and finally clean the air in the room.
Operation
POWER/SOFT Operation
(1)
TIMER ON
(2)
TIMER OFF
You can let unit start or stop automatically a following times:
Before you wake up in the morning, or get back from outside
Set Clock correctly before starting Timer operation
(3)
TIMER Operation
TIMER ON-OFF
(This function is unavailable on some models.)
MODE SET
FAN
TIMER
MODE SET
FAN
TIMER
MODE SET
FAN
TIMER
MODE SET
FAN
TIMER
or after you fall asleep at night.
Emergency Operation:
temperature is below 16
o
C, do not use it in the
Test operation:
Use this switch in the test operation when the room
normal operation.
your finger from the switch: the cooling
Continue to press the test operation switch for more than 5 seconds. After
you hear the "Pi" sound twice,
release
Test operation switch is the same as emergency switch.
operation starts with the air flow speed "Hi".
When you need rapid heating or cooling,
You can use this function when silence
In SOFT operation mode, fan speed
automatically takes low speed of AUTO fan mode.
Press POWER/SOFT button again ,POWER/SOFT disappears.
To cancel SOFT operation
(1)
POWER Operation
(2)
SOFT Operation
you can use this function.
is needed for rest or reading.
Press POWER/SOFT button twice ,POWER/SOFT disappears.
To cancel POWER operation
In COOL mode, fan speed automatically takes high speed of AUTO fan mode.
In HEAT mode, fan speed automatically takes medial speed of AUTO fan mode.
Emergency operation and test operation
Use this operation only when the remote controller is defective or lost.
When the emergency ope
ration switch is pressed,the" Pi "sound is heard once, which means the start of this operation.
In this ope
ration, the system automatically selects the operation modes,cooling or fan or heat,according to the room temperature.
It is not possible to operate in dry mode.
Room temperature
Operation mode
Designated temperature
Timer mode
Air flow
ABOVE 23
O
C
BELOW 23
O
C
COOLING
HEAT
23
O
C
26OC
NO
NO
AUTOMATIC
AUTOMATIC
Pi
(Cooling only uint
Room temperature
Operation mode
Designated temperature
Timer mode
Air flow
BELOW 23
O
C
FAN
26
O
C
NO
AUTOMATIC
Pi Pi
SWING
CLOCK
SLEEP
HEALTH
POWER/SOFT
MODE SET
FAN
TIMER
MODE SET
FAN
TIMER
MODE SET
FAN
TIMER
MODE SET
FAN
TIMER
MODE SET
FAN
TIMER
SWING
CLOCK
SLEEP
HEALTH
POWER/SOFT
SWING
CLOCK
SLEEP
HEALTH
POWER/SOFT
After 30 minutes, test operation ends automatically(Only for 22K,24K unit).
(This function is unavailable on some models.)
3
Operation
SWING
CLOCK
SLEEP
LOCK RESET
HEALTH
POWER/SOFT
Comfortable SLEEP
(This function is unavailable on some models.)
Before going to bed,you can simply press the SLEEP button
you a sound sleep.
and unit will operate in SLEEP mode and bring
SLEEP Operation
In HEAT mode
2.
1 hours after SLEEP mode starts, temp will become 2 OC lower than temp.setting. After another 1 hours, temp decrease by 2 C
O
further. After more another 3 hours, temp.
rises by 1 C further. The unit will run for
O
further 3 hours then stops. Temp. is lower than
temp. setting so that room temperature
won't be too high for your sleep.
Operation Mode
1. In COOL,DRY mode
1 hours after SLEEP mode starts, temp. will
O
become 1 another 1 hours, temp. rises by 1
The unit will run for further 6 hours then stops Temp. is higher than temp. setting so that room
temperature won't be too Iow for your sleep.
SLEEP operation starts
Temp.setting
C higher than temp. setting. After
O
C further.
SLEEP operation stops
Approx.6hrs
O
C
1 hr
1 hr
Rises1
Rises 1
O
C
Unit stop
In COOL, DRY mode
Temp.setting
1 hr
Decreases 2
1 hr
Decreases 2
Unit stop
O
C
O
C
3 hrs
3 hrs
SLEEP
operation starts
Rises 1OC
SLEEP
operation stops
In HEAT mode
3.In AUTO mode The unit operates in corresponding sleep mode
corresponding sleep mode adapted to the
automatically selected operation mode.
4. In FAN mode
It has no SLEEP function.
5.
When quiet sleeping function is set to 8 hours
the quiet sleeping time can not be adjusted.When
TIMER function is set,the quiet sleeping function
can't be set up.After the sleeping function is set
up,if user resets TIMER function, the sleeping
function will be cancelled; the machine will be in
the state of timing-on,if the two at the same time,
either of their operation time is
ended first ,the unit will stop automatically,and the other mode will be cancelled.
modes are set up
Power Failure Resume Function
If the unit is started for the first time, the compressor will not start running unless 3 minutes have elapsed. When the power resumes after power failure, the unit will run automatically,
and 3 minutes later the compressor starts running.
Note to the power failure resume:
press the sleep button ten times in five seconds and enter
function after hearing four sounds.And press the sleep button
ten times within five seconds and leave this function after
hearing two sounds.
4
Maintenance
For Smart Use of The Air Conditioner
Setting of proper room temperature
Proper temperature
Close doors and windows during operation
During cooling operation prevent the penetration of direct sunlight with curtain or blind
If the unit is not to be used for a long time, turn off the power supply main switch.
OFF
Do not block the air inlet or outlet
Use the timer effectively
Use the louvers effectively
Remote Controller
Do not use water ,wipe the controller with a dry cloth.Do not use glass cleaner or chemical cloth.
Do not use the following for cleaning
Gasoline,benzine, thinner or cleanser may damage the coating of the unit.
Air Filter cleaning
Open the inlet grille by pulling it upward.
Remove the filter.
Push up the filter's center tab slightly until it is released from the stopper, and remove the filter downward.
Clean the filter.
Use a vacuum cleaner to remove dust, or wash the filter with water.After washing, dry the filter completely in the shade.
Attach the filter.
Attach the filter correctly so that the "FRONT" indication is facing to the front.Make sure that the filter is completely fixed behind the stopper.If the right and left filters are not attached correctly, that may cause defects.
Close the inlet grille.
Indoor Body
Wipe the air conditioner by using a soft and dry cloth.For serious stains,use a neutral detergent diluted with water.Wring the water out of the cloth before wiping.then wipe off the detergent completely.
Hot water over 40OC(104OF) may cause discoloring or deformation.
Once every two weeks
Replacement of Air Purifying Filter
1.Open the lnlet Grille
Prop up the inlet grille by using a
small device named grille-support
which located in the right side of
the indoor unit.
2.Detach the standard air filter
Slide the knob slightly upward to release the filter, then withdraw it.
Detach old Air Purifying Filter
3.Attach Air Purifying Filter
Put air purifying filter appliances into the right and left filter frames.
(NOTE: Air purifying filter is optional part)
4.Attach the standard air filter
(Necessary installation)
ATTENTION: The white side of the photocatalyst air purifying
filter face outside,
The green side of the bacteria-killing medium air
purifying filter face outside,
5.Close the Inlet Grille
Close the Grille surely
NOTE:
The photocatalyst air purifying filter will be solarized in fixed time. In normal family,
The bacteria-killing medium air purifying filter will be used for a long time,no need for replacement. But in the period of using them ,you should remove the dust frequently by
using vacuum cleaner or flaping them lightly,otherwise ,
its performance will be affected.
and the black side face the unit.
and the white side face the unit.
it will be solarized every 6 months.
Please keep the bacteria-killing medium air purifying filter in the cool and dry conditions when you stop using it,or its ability of sterilization will
avoid long time directly sunshine
be
reduced.
5
Cautions
WARNING
Please call Sales/Service Shop for the Installation. Do not attempt to install the air conditioner by yourself because improper works
may cause electric shock, fire, water leakage.
Connect the earth cable.
earthing
WARNING
When abnormality such as burnt-small found, immediately stop the operation button and contact sales shop.
OFF
Use an exclusive power source with a circuit breaker
ENFORCEMENT
Connect power supply cord to the outlet completely
Use the proper voltage
Do not use power supply cord in a bundle.
Take care not to damage
the power supply cord.
1.Do not use power supply cord extended or connected in halfway
STRICT
ENFORCEMENT
STRICT
STRICT
ENFORCEMENT
PROHIBITION
PROHIBITION
PROHIBITION
PROHIBITION
Do not start or stop the
operation by disconnecting
Do not channel the air flow directly at people, especially at infants or the aged.
Do not try to repair or reconstruct by yourself.
Do not use for the purpose of storage of food, art work, precise equipment, breeding, or cultivation.
CAUTION
Take fresh air occasionally especially when gas appliance is running at the same time.
PROHIBITION
STRICT
ENFORCEMENT
Do not operate the switch with wet hand.
PROHIBITION
PROHIBITION
PROHIBITION
PROHIBITION
PROHIBITION
Do not install the unit near a fireplace or other heating apparatus.
Check good condition of the installation stand
Do not pour water onto the unit for cleaning
PROHIBITION
Do not place animals or plants in the direct path of the air flow
Do not place any objects on or climb on the unit.
Do not place flower vase or water containers on the top of the unit.
Do not insert objects into the air inlet or outlet.
PROHIBITION
PROHIBITION
PROHIBITION
STRICT ENFORCEMENT
Check proper installation of the drainage securely
the power supply cord and so on.
2.
Do not install in the place where there is any
possibility of inflammable gas leakage around the unit.
3.Do not get the unit exposed
to vapor or oil steam.
6
Trouble shooting
Before asking for service, check the following first.
Cause or check points
When unit is stopped, it won't restart
immediately until 3 minutes have
elapsed to protect the system. When the electric plug is pulled out
and reinserted, the protection circuit will work for 3 minutes to protect the
air conditioner.
During unit operation or at stop, a swishing or gurgling noise may
be heard.At first 2-3 minutes after
unit start, this noise is more noticeable.
(This noise is generated by
refrigerant flowing in the system.)
During unit operation, a cracking noise may be heard.This noise is
generated by the casing expanding or shrinking because of temperature changes.
Should there be a big noise from
air flow in unit operation, air
filter may be too dirty.
This is because the system circulates smells from the interior air such as the smell of furniture, paint, cigarettes.
During COOL or DRY operation,
indoor unit may blow out mist. This is due to the sudden cooling of indoor air.
In DRY mode, when room temperature becomeslower than temp.setting+2oC,unit will run intermittently at LOW speed regardless of FAN setting.
Is power plug inserted? Is there a power failure? Is fuse blownout?
Is the air filter dirty?
Normally it should be cleaned
every 15 days. Are there any obstacles before inlet and outlet? Is temperature set correctly? Are there some doors or
windows left open? Is there any direct sunlight through the window during the cooling operation?(Use curtain)
Are there too much heat sources or too many people in the room during cooling operation?
Normal Performance inspection
Multiple
check
Phenomenon
The system does not restart immediately.
Noise is heard
Smells are generated.
Mist or steam are blown out.
In dry mode,
speed can’t be changed.
Poor cooling
fan
Cautions
The machine is adaptive in following situation
1.Applicable ambient temperature range:
For: T1
For: T3
Indoor
Cooling
Outdoor
Indoor
Heating
Outdoor
Indoor
Cooling
Outdoor
Indoor
Heating
Outdoor
Maximum: D.B / W.B 32 Minimum: D.B / W.B Maximum: D.B Minimum: D.B Maximum: D.B Minimum: D.B Maximum: D.B / W.B Minimum: D.B / W.B
Maximum: D.B / W.B Minimum: D.B / W.B
Maximum: D.B / W.B Minimum: D.B
Maximum: D.B Minimum: D.B
Maximum: D.B / W.B Minimum: D.B / W.B
29oC/19oC 18oC/14oC
54oC/24oC 18oC
27oC 15oC
24oC/18oC
-7oC/-8oC
2. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified
The type of connecting wire is H05RN-F or H07RN-F
3. If the fuse on PC board is broken please change it with a fuse
type T. 3.15A/250V.
If the fuse of outdoor unit on PC board is broken, please change it with the type of T. 25A/250V.
4.The distance between the indoor unit and the floor should be
more than 2m.
5.The wiring method should be in line with the local wiring standard.
6.
After installation, the power plug should be easily reached..
7.The used batteries should be disposed of properly.
8.The appliance is not intended to use by young children or infirm persons without supervision.
9.Young children should be supervised ensure that they do not
play with the appliance.
10.The appliance must be installed on a strong enough support.
11.The wiring diagram is attached inside the machine.
18 43 18 27
15 24
-7
o
C/23
o
C/14
o
C/26
o
C
o
C
o
C
o
C/18
o
C/-8
person.
o
C
o
C
o
C
o
C
o
C
Application temp. range of air conditioner -7
T1: T3:
Application temp. range of air conditioner -7
7
o
C~43oC.
o
C~54oC.
Loading...