Installation Manual of Room Air Conditioner
Read this manual before installation
Explain sufficiently the operating means to the user
according to this manual.
Necessary Tools for Installation
1.Driver
2.Hacksaw
3.Hole core drill
4.Spanner(17,19 and 26mm)
Accessory parts
No. Accessory parts
1
2
3
4
5
Remote controller
R-03 dry battery
Mounting plate
Drain hose
4X50
Steel nail, cement
Number
of
articles
1
2
1
1
6
5.Torque wrench(17mm,22mm,26mm)
6.Pipe cutter
7.Flaring tool
8.Knife
9.Nipper 12.Reamer
10.Gas leakage detector or
soap-and-water solution
11.Measuring tape
Drawing for the installation of indoor and outdoor units
Optional parts for piping
Mark
A
B
C
D
E
F
G
Parts name
Non-adhesive tape
Adhesive tape
Saddle(L.S) with screws
Connecting electric cable
for indoor and outdoor
Drain hose
Heating insulating material
Piping hole cover
more than 10cm
more than 5cm
Attention must be paid to
the rising up of drain hose
more than 10cm
6
7
8
4X25
Screw
9
Plastic cap
Cover
Cushion
Pipe supporting plate
No.0010515136
4
A
1
4
1
Arrangement of piping directions
Rear left
Below
Rear
right
Right
Left
more than 10cm
more than 60cm
A
The marks from to in the figure are the parts numbers.
G
more than 10cm
more than 15cm
The distance between the indoor unit and the floor should be
more than 2m.
C
D
E
HSU-05LEA03
HSU-07LEA03
HSU-09LEA03
HSU-09LEA13-W
HSU-12LEA13-W
HSU-09LEA13-F
HSU-07HEA03
HSU-09HEA03
HSU-12HEB03
HSU-09CRA03-T
AMS09H03-N
YKS-09HEA03
HSU-09LEA03-N
HSU-09LEN03
HSU-09CA2
140 140415
Floor fixing dimensions
of the outdoor unit
(Unit:mm)
280
HSU-12LEA03
HSU-18LEA03
HSU-18LEA13-W
HSU-10LEA03-T
HSU-13LEA03-T
HSU-09LEB13-H
HSU-09LEA13-H
HSU-12LEA13-H
HSU-14LEA13-H
HSU-12LEB13-H
HSU-14LEB13-H
HSU-18LEA13-H
HSU-12CRA03-T
HSU-18CRA03-T
AMS12H03-N
AMS18H03-N
PAS18L03-N(T3)
HSU-18HEA13(T3)
HSU-18HEA03(T3)
HSU-12LEN03
HSU-18LEN03
HSU-09HEC03
HSU-12HEC03
Selection of pipe
140
500
140
Floor fixing dimensions
of the outdoor unit
(Unit:mm)
HSU-09HEA03/(DB)
HSU-09HEA03/(BP)
HSU-12HEA03/(DB)
HSU-12HEA03/(BP)
HSU-12LEA13-M
HSU-18LEA13-M
HSU-18LEA03(T3)
HSU-18LEA13(T3)
HSU-12LEA13-F
HSU-12HEA03
HSU-18HEA03
YKS-12HEA03
YKS-18HEA03
HSU-10LED03-T
HSU-13LED03-T
HSU-12CA2
HSU-12CB2
HSU-18LB2
HSU-18LA2
HEC-18LEA03(T3)
256
HSU-22LEA03
HSU-24LEA03
HSU-22LEA13-W
HSU-18LEA03-T
AMS22H03-N
HSU-22HEA03
HSU-24HEA03
YKS-22HEA03
HSU-18LED03-T
HSU-18LED03-T1
HSU-24LA2
583
113.5
113.5
Floor fixing dimensions
of the outdoor unit
(Unit:mm)
9 5.1
3
To this unit, both liquid and gas pipes shall be insulated
as they become Iow temperature in operation.
Use optional parts for piping set or pipes covered with
equivalent insulation material.
For 5k,7k,9k,10k
Liquid pipe ( )
6.35mm(1/4")
Gas pipe ( ) 9.52mm(3/8")
For 12k,13k,18k
6.35mm(1/4")
12.7mm(1/2")
Indoor unit
1.Fitting of the Mounting Plate and Positioning of the wall Hole
When the mounting plate is first fixed
1.Carry out, based on the neighboring pillars or lintels, a proper leveling for the plate to be
fixed against the wall, then temporarily fasten the plate with one steel nail.
2. Make sure once more the proper level of the plate, by hanging a thread with a weight from
the central top of the plate, then fasten securely the plate with the attachment steel nail.
3. Find the wall hole location A using a measuring tape
B= 60mm
HSU-12LEA13-F
HSU-12HEA03
HSU-05LEA03
HSU-07LEA03
HSU-09LEA03
HSU-09LEA13-W
HSU-12LEA13-M
HSU-09LEB13-H
HSU-10LEA03-T
A=145mm
HSU-10LED03-T
HSU-09LEA03-N
A=145mm
30mm
HSU-09CA2
HSU-12CA2
HSU-12CB2
HSU-12LEN03
HSU-09LEN03
HSU-09HEA03
HSU-09LEA13-H
HSU-09LEA13-F
HSU-12LEA03
HSU-12LEA13-W
For 22k,24k
18LEA03-T,
18CRA03-T,
18LEA03-T1
18LED03-T
9.52mm(3/8")
15.88mm(5/8")
B= 60mm
HSU-09HEC03
HSU-12HEC03
30mm
2.Making a Hole on the Wall and Fitting the Piping Hole Cover
Make a hole of 60 mm in diameter,
slightly descending to outside the wall.
Install piping hole cover and seal it
off with putty after installation
Indoor side
(Section of wall hole)
2
Wall hole
60mm
G
Piping hole pipe
Outdoor side
Thickness
of wall