Haier HSU-12HEA03/R2-I, HSU-18HEA03/R2-I, HSU-09HEA03/R2 - annexe 1, HSU-12HEA03/R2 - annexe 2, HSU-18HEA03/R2 Installation Manual

INSTALLATION MANUAL
ROOM AIR CONDITIONER WALL MOUNTED TYPE
NO.0010523234
Read this manual before installation
Explain sufficiently the operating means to the user
according to this manual.
No.00105
1.Driver
2.Hacksaw
3.Hole core drill
4.Spanner(17,19 and 26mm)
5.Torque wrench(17mm,22mm,26mm)
6.Pipe cutter
7.Flaring tool
8.Knife
9.Nipper 12.Reamer
10.Gas leakage detector or soap-and-
water solution
11.Measuring tape
A
B
C
D
E
F
G
Optional parts for piping
Ma
rk
Parts name
Non-adhesi
ve tape
Adhesive tape
Saddle(L.S) with screws
Connecting elect
ric cable
for indoor and outdoor
Drain hose
Heating insulating mate
rial
Piping hole c
over
Arrangement of piping directions
Rear left
Rear right
Left
Bel
ow
Right
The marks from to in the figure are the parts numbers.
The distance bet
ween the indoor unit and the floor should be
more than 2m.
A
G
Attention must be paid to the rising up of drain hose
m c5n
a h t e ro
m
mc0
1
nah
t
e
r
o
m
m
c
0
1n
aht
e
r
o
m
A
C
No. Accessory parts
Remote controller
R-03 d
ry battery
Mounting plate
Drain hose
Steel nail, cement
Scr
ew
Plastic cap
Cover
Cushion
1
1
2
3
4
5
6
7
8
9
2
1
1
6
4
1
4
1
Number of articles
Accessory parts
4X50
4X25
Pipe supporting plate
m
c
0
1
na
h
t
e
r
om
m
c0
6
n
ah
t
er
om
m
c
5
1
n
a
h
ter
o
m
m
c
01
n
a
ht
er
o
m
D
E
Drawing for the installation of indoor and outdoor units
Necessary Tools for Installation
10
Drain-elbow
1
Liquid pipe ( )
For 09K .12K
6.35mm(1/4")
Gas pipe ( ) 9.52mm(3/8")
For 18K
6.35mm(1/4")
12.7mm(1/2")
Fixing of outdoor unit
Indoor Unit
Selection of Installation Place
Power Source
Selection of pipe
Outdoor Unit
Fix the unit to concrete or block with bolts( 10mm) and nuts firmly and horizontally.
When fitting the unit to wall surface, roof or rooftop, fix a supporter surely with nails or wires in consideration of earthquake and strong wind.
If vibration may affect the house, fix the unit by attaching a vibration-proof mat.
Place, robust not causing vibration, where the body can be supported sufficiently. Place, not affected by heat or steam generated in the vicinity, where inlet and outlet of the unit are not disturbed. Place, possible to drain easily, where piping can be connected with the outdoor unit. Place, where cold air can be spread in a room entirely. Place, nearby a power receptacle, with enough space around. (Refer to drawings). Place where the distance of more than lm from televisions, radios, wireless apparatuses and fluorescent lamps can be left. In the case of fixing the remote controller on a wall, place where the indoor unit can receive signals when the fluorescent lamps in the room are lightened.
Place, which is less affected by rain or direct sunlight and is sufficiently ventilated. Place, possible to bear the unit, where vibration and noise are not increased. Place, where discharged wind and noise do not cause a nuisance to the neighbors. Place, where a distance marked is available as illustrated in the above figure.
Before inserting power plug into receptacle, check the voltage without fail. The power source is the same as the corresponding name plate.
Install an exclusive branch circuit of the power.
A receptacle shall be set up in a distance where the power cable can be reached. Do not extend the cable by cutting it.
To this unit, both liquid and gas pipes shall be insulated
as they become Iow temperature in operation.
Use optional parts for piping set or pipes covered with
equivalent insulation material.
2
Floor fixing dimensions of the outdoor unit (Unit:mm)
HSU-12HEA03/R2-I
HSU-18HEA03/R2-I
HSU-09HEA03/R2-I
Floor fixing dimensions of the outdoor unit (Unit:mm)
580
115
115
319.5
Indoor unit
1.Fitting of the Mounting Plate and Positioning of the wall Hole
2.Making a Hole on the Wall and Fitting the Piping Hole Cover
When the mounting plate is first fixed
When the mounting plate is fixed side bar and lintel
1.Carry out, based on the neighboring pillars or lintels, a proper leveling for the plate to be fixed against the wall, then temporarily fasten the plate with one steel nail.
2. Make sure once more the proper level of the plate, by hanging a thread with a weight from the central top of the plate, then fasten securely the plate with the attachment steel nail.
3. Find the wall hole location A using a measuring tape
Refer to the previous article, " When the mounting plate is first fixed ", for the position of wall hole.
Fix to side bar and lintel a mounting bar, Which is separately sold, and then fasten
the plate to the fixed mounting bar.
Make a hole of 60 mm in diameter, slightly descending to outside the wall. Install piping hole cover and seal it off with putty after installation
(Section of wall hole)
Piping hole pipe
Outdoor side
Thickness of wall
Indoor side
Wall hole
60mm
3.Installation of the Indoor Unit
Drawing of pipe
[ Rear piping ]
Draw pipes and the drain hose, then fasten them with the adhesive tape
[ Left Left-rear piping ]
In case of left side piping, cut away, with a nipper, the lid for left piping. In case of left-rear piping, bend the pipes according to the piping direction to the mark of hole for left-rear piping which is marked on heat insulation materials.
3
G
A=145mm
B= 60mm
30mm
Loading...