Before disposing an old air conditioner that goes out of use, please make sure it's inop­erative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment.
It must be noticed that air conditioner system contains refrigerants, which require speciali­zed waste disposal. The valuable materials contained in an air conditioner can be recycled .Contact your local waste disposal center for proper disposal of an old air conditioner and contact your local authority or your dealer if you have any question. Please ensure that the pipework of your air conditioner does not get damagedprior to being picked up by the relevant waste disposal center, and contribute to environmental awareness by insisting on an appropriate, anti-pollution method of disposal.
Cautions
Disposal of the old air conditioner
All the packaging materials employed in the package of your new air conditioner may be disposed without any danger to the environment.
The cardboard box may be broken or cut into smaller pieces and given to a waste paper disposal service. The wrapping bag made of polyethylene and the polyethylene foam pads
contain no fluorochloric hydrocarbon.
All these valuable materials may be taken to a waste collecting center and used again after adequate recycling.
Consult your local authorities for the name and address of the waste materials collecting centers and waste paper disposal services nearest to your house.
Disposal of the packaging of your new air conditioner
Before starting the air conditioner, read the information given in the User's Guide caref­ully. The User's Guide contains very impor­tant observations relating to the assembly, operation and maintenance of the air conditioner.
The manufacturer does not accept respon­sibility for any damages that may arise due to non-observation of the following instruction.
Damaged air conditioners are not to be put into operation. In case of doubt, consult your supplier.
Use of the air conditioner is to be carried out in strict compliance with the relative instructions set forth in the User's Guide.
Installation shall be done by professional people, don't install unit by yourself.
For the purpose of the safety,the air con­ditioner must be properly grounded in acco­rdance with specifications.
Always remember to unplug the air conditioner before openning inlet grill. Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the outlet.
All electrical repairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditioner.
Safety Instructions and Warnings
Do not damage any parts of the air conditioner that carry refrigerant by piercing or performating the air conditioner's tubes with sharp or pointed items, crushing or twisting any tubes, or scraping the coatings off the surfaces. If the refrigerant spurts out and gets into eyes, it may result in serious eye injuries.
Do not damage any parts of the air conditioner that carry refrigerant by piercing or performating the air conditioner's tubes with sharp or pointed items, crushing or twisting any tubes, or scraping the coatings off the surfaces. If the refrigerant spurts out and gets into eyes, it may result in serious eye injuries.
1
3. If the fuse of indoor unit on PC board is broken,please change it with the type of T. 3.15A/ 250V. If the fuse of outdoor unit is broken,change it with the type of T.25A/250V
Do not obstruct or cover the ventilation grille of the air conditoner.Do not put fingers or any other things into the inlet/outlet and swing louver.
Do not allow children to play with the air conditioner.In no case should children be allowed to sit on the outdoor unit.
The refrigerating circuit is leak-proof.
1.Applicable ambient temperature range:
Cooling
Indoor
Maximum:D.B/W.B
32oC/23oC
24oC/18oC
-15oC
43oC/26oC 18oC
27oC 15oC
18oC/14oC
Maximum:D.B/W.B Maximum:D.B
Maximum:D.B Maximum:D.B
Minimum:D.B/W.B
Maximum:D.B/W.B Minimum:D.B/W.B
Outdoor
Indoor
Outdoor
Heating
Specifications
The machine is adaptive in following situation
10 .The power plug and connecting cable must have acquired the local attestation.
2. If the power supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person.
4. The wiring method should be in line with the local wiring standard.
5. After installation, the power plug should be easily reached.
6. The waste battery should be disposed properly.
7. The appliance is not intended for use by young children or infirm persons without supervision.
8. Young children should be supervised to ensure that they do not play with the applience.
9.Please employ the proper power plug, which fit into the power supply cord.
Cautions
11.In order to protect the units,please turn off the A/C first, and at least 30 seconds later, cutting off the power.
2
Cautions
STRICT ENFORCEMENT
Safety Instruction
Installation
WARNING
Please read the following Safety Instructions carefully prior to use.
The instructions are classified into two levels, WARNING and CAUTION according to the seriousness of possible risks and damages as follows. Compliance to the instructions are strictly required for safety use.
Please call Sales/Service Shop for the Installation.
Do not attempt to install the air conditioner by yourself because improper works may cause electric shock, fire, water leakage.
lnstallation in a inadequate place may cause accidents. Do not install in the following place.
Connect the earth cable.
earthing
Do not install in the place where there is any possibility of inflammable gas leakage around the unit.
Do not get the unit exposed to vapor or oil steam.
Check proper installation of the drainage securely
PROHIBITION PROHIBITION
CAUTION
3
Cautions
WARNING
When abnormality such as burnt-small found, immediately stop the operation button and contact sales shop.
OFF
Use an exclusive power source with a circuit breaker
ENFORCEMENT
Connect power supply cord to the outlet completely
Use the proper voltage
Do not use power supply cord in a bundle.
Take care not to damage
the power supply cord.
Do not use power supply cord
extended or connected in halfway
STRICT
ENFORCEMENT
STRICT
STRICT
ENFORCEMENT
PROHIBITION
PROHIBITION
PROHIBITION
PROHIBITION
Do not start or stop the operation by disconnecting the power supply cord and so on.
Do not channel the air flow directly at people, especially at infants or the aged.
Do not try to repair or reconstruct by yourself.
Do not use for the purpose of storage of food, art work, precise equipment, breeding, or cultivation.
CAUTION
Take fresh air occasionally especially when gas appliance is running at the same time.
PROHIBITION
STRICT
ENFORCEMENT
Do not operate the switch with wet hand.
PROHIBITION
PROHIBITION
PROHIBITION
PROHIBITION
PROHIBITION
Do not install the unit near a fireplace or other heating apparatus.
Check good condition of the installation stand
Do not pour water onto the unit for cleaning
PROHIBITION
Do not place animals or plants in the direct path of the air flow
Do not place any objects on or climb on the unit.
Do not place flower vase or water containers on the top of the unit.
Do not insert objects into the air inlet or outlet.
PROHIBITION
PROHIBITION
PROHIBITION
4
Parts and Functions
Indoor unit
Outdoor unit
Inlet
Air Purifying Filter
Vertical flap (adjust up and down air flow. Don't adjust it manually)
Horizontal louver(inside)
Inlet grille
Power plug
(adjust left and right air flow)
(inside)
Outlet
Anion generator
(inside)
Air filter(inside)
display board(inside)
UV light degerming device (inside)
CHANGE-FOR-FRESH-AIR BOX
OUTLET
CONNECTING PIPING AND ELECTRICAL WIRING
INLET
1 2 3
4
CHANGE-FOR-FRESH-AIR TUBE
CHANGE FOR FRESH AIR SIGNAL WIRE
DRAIN HOSE
5 6
7
5
SWING
CODE
TEMP
LOCK RESETLIGHT
TIMER
SET
CLOCK
FRESHSLEEP
MODE
HEALTH FAN
H.AIR.
28
30
20
21
22
23 24
25
27
26
26
29
32
31
19
33
Parts and Functions
Used to set healthy operation.
10. HEALTH button
Used for unit start and stop.
11. ON/OFF button
12. TIMER ON display
13. FAN SPEED display
LOW HI
MED AUTO
14. LOCK display
15. SWING UP/DOWN display
16. SLEEP display
17. HEALTH display
Used to select your desired temperature.
Operation mode
AUTO HEAT FANCOOL DRY
Remote controller
19. Operation mode display
Display board
21. POWER/SOFT display
22. Left/right air flow display
Remote controller: to display the TEMP. setting.
23. TEMP display
24. TIMER OFF display
25. CLOCK display
26. TEMP button
Used to select fan speed: LOW,MED, HI, AUTO.
27. FAN button
Used to set the health airflow mode.
9. HEALTH AIRFLOW button
28. SWING UP/DOWN button
Used to select up or down air sending direction.
29. SWING LEFT/RIGHT button
Used to select left/right air flow.
30.
FRESH
button
Used to confirm timer and clock settings.
31. SET button
32. POWER/SOFT button
Use to set power/soft function.
Use to set fresh air function.
Used to select CODE A or B with a press,A or B will be displayed on LCD. Please select A without special explanation.
3.CODE
When the remote controller appears abnormal, use a sharp pointed article to press this button to reset the remote controller normal.
33. RESET
Used to select TIMER ON, TIMER OFF, TIMER ON-OFF.
4. TIMER button
Used to set correct time.
5. CLOCK button
Used to select sleep mode.
6. SLEEP button
7. MODE button
AUTO COOL DRY FAN HEAT
Used to set clock and timer setting.
8. HOUR button
Used to lock buttons and LCD display. If pressed, the other buttons will be disabled and the lock condition display appears. Press it once again, lock will be canceled and lock condition display disappears.
1. LOCK
18.FRESH AIR display
20.Singal sending display
NOTE: Cooling only unit do not have functions and displays related with heating.
2.LIGHT button
Control the lightening and extinguishing of the indoor LED display board.
The fresh function is optional.
6
Remove the batteries in case unit won't be in usage for a long period. If there are any display after taking-out, just need to press reset key.
Parts and Functions
Clock Set
When unit is started for the first time and after replacing batteries in remote controller, clock should be adjusted as follows:
Remote controller's operation
3. After time setting is confirmed, press SET, "AM" or "PM" stop flashing, while clock starts working.
2. Press or to set correct time. Each press will increase or decrease 1 min. If the button is kept depressed, time will change quickly.
1. Press CLOCK button,"AM" or "PM" flashes.
When in use, put the signal transmission head directly to the receiver hole on the indoor unit.
The distance between the signal transmission head and the receiver hole should be within 7m without any obstacle as well.
Don't throw or knock the remoter controller.
When electronic-started type fluorescent lamp or change-over type fluorescent lamp or wireless telephone is installed in the room, the receiver is apt to be disturbed in receiving the signals, so the distance to the indoor unit should be shorter.
Loading of the battery
Load the batteries as illustrated right 2 R-03 (7#) batteries
Remove the battery cover:
Slightly press" "area and push down the cover as illustrated.
Load the battery: Be sure that the loading is in line with the "+" / "-".
request as illustrated on the bottom of the case. Put on the cover again.
Confirmation indicator:
After pressing power "
", if no display, reload the batteries.
Note:
Full display or unclear display during operation indicates the batteries have been used up. Please change batteries.
Used two new same-typed batteries when loading. If the remote controller can't run normally during operation, please remove the batteries and
reload several minutes later.
Hint:
7
SWING
CODE
TEMP
LOCK RESETLIGHT
TIMER
SET
CLOCK
FRESHSLEEP
MODE
HEALTH
FAN
H.AIR.
Operation
Remote controller
8
2.Health anion function
Air conditioner starts health anion function operation. For twice press, disappears,the operation stops.
3.Change-for-fresh-air function(optional)
Press FRESH button , "
"displayed on the remote controller and the change-for-fresh-air function operation begins. For twice press , the display "
"disappears and the
change-for-fresh-air function operation is canceled
BRIEF INTRODUCTION TO HEALTH ANION FUCTION
UV light emitted by the UV light device of the indoor unit catalytically activates the nano TiO2 on the multi-lights touching intermediary, and the degerming effect is highly efficient and lasting. Note: when the function is running, don't open the inlet grille.
About UV light degerming function
1.After the change-for-fresh-air function is initiated, the outside air can enter the indoors through the change-for-fresh-air tube thereby keeping the indoor air fresh.
About change-for-fresh-air function(optional)
Health function includes health anion function, UV light degerming function.
The anion generator in the air conditioner can generate a lot of anion effectively balance the quantity of position and anion in the air and also to kill bacteria and speed up the dust sediment in the room and finally clean the air in the room.
When the fan in the indoor unit does not work, the health lamp lights up, but the anion generator does not release anion.
When indoor fan motor is running, it has healthy process function. (It's available under any mode)
Press HEALTH button. For each press, is displayed.
1.Unit start
2.Setting the change-for-fresh-air function under the shutdown status: Under shutdown status, press the fresh key and the remote controller displays the on status of air flow, low wind, and change­ for-fresh-air functions, and now can set the timing open, timing close and time control switch. Press on/off button (" ") to cancel the change-for-fresh-air function.
Press on/off button (" ") on the remote controller, unit starts.
HEALTH operation
SWING
CODE
TEMP
LOCK RESETLIGHT
TIMER
SET
CLOCK
FRESHSLEEP
MODE
HEALTH FAN
H.AIR.
Auto Operation
Operation
Remote controller
About Auto Operation Under the mode of auto operation, air conditioner will automatically select Cool or Heat operation according to room temperature.
5.Unit stop
Press on/off button (" "), the unit stops.
1. Unit start
2.Select operation mode
Press MODE button. For each press, operation mode changes as follows:
Remote controller:
Then
Select Auto operation
AUTO COOL DRY FAN HEAT
Press FAN button. For each press, fan speed changes as follows:
Remote controller:
Press TEMP. button
Every time the button is pressed, temp.setting increase 1oC,if kept depressed, it will increase rapidly
Every time the button is pressed, temp.setting decrease 1oC,if kept depressed, it will decrease rapidly
Select a desired temperature.
4.Fan speed selection
3.Select temp.setting
Air conditioner is running under displayed fan speed. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.
LOW
MED
HI
AUTO
Press on/off button (" ") on the remote controller, unit starts.
9
SWING
CODE
TEMP
LOCK RESETLIGHT
TIMER
SET
CLOCK
FRESHSLEEP
MODE
HEALTH FAN
H.AIR.
Cool Operation
Remote controller
2.Select operation mode
Press FAN button. For each press, fan speed changes as follows:
Press MODE button. For each press, operation mode changes as follows:
Remote controller:
Remote controller:
Then Select COOL operation
Press TEMP. button
Every time the button is pressed, temp.setting increase 1oC,if kept depressed, it will increase rapidly
Every time the button is pressed, temp.setting decrease 1oC,if kept depressed, it will decrease rapidly
Select a desired temperature.
4.Fan speed selection
3.Select temp.setting
5.Unit stop
Air conditioner is running under displayed fan speed. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.
Press on/off button (" "), the unit stops.
AUTO
LOW
MED
HI
AUTO
COOL DRY FAN HEAT
1. Unit start
Operation
Press on/off button (" ") on the remote controller, unit starts.
10
SWING
CODE
TEMP
LOCK RESETLIGHT
TIMER
SET
CLOCK
FRESHSLEEP
MODE
HEALTH FAN
H.AIR.
2.Select operation mode
Press FAN button. For each press, fan speed changes as follows:
Press MODE button. For each press, operation mode changes as follows:
Remote controller:
Remote controller:
Then Select DRY operation
Press TEMP. button
Every time the button is pressed, temp.setting increase 1oC,if kept depressed, it will increase rapidly
Every time the button is pressed, temp.setting decrease 1oC,if kept depressed, it will decrease rapidly
Select a desired temperature.
4.Fan speed selection
3.Select temp.setting
5.Unit stop
Press on/off button (" "), the unit stops.
COOL operation starts when room temp.is higher than temp.setting.
On reaching temp.setting +2oC unit will run in mild DRY mode.
Ultra-low air flow
Temp.setting+2oC Temp.setting
AUTO
LOW
MED
HI
AUTO
COOL DRY FAN HEAT
Operation
Dry Operation
1. Unit start
Remote controller
Air conditioner is running under displayed fan speed. In DRY mode, when room temperature becomes lower than temp.setting+2oC,unit will run intermittently at LOW speed regardless of FAN setting.
Press on/off button (" ") on the remote controller, unit starts.
11
SWING
CODE
TEMP
LOCK RESETLIGHT
TIMER
SET
CLOCK
FRESHSLEEP
MODE
HEALTH FAN
H.AIR.
Fan Operation
2.Select operation mode
Press FAN button. For each press, fan speed changes as follows:
Press MODE button. For each press, operation mode changes as follows:
Remote controller:
Remote controller:
Then Select FAN operation
3.Fan speed selection
4.Unit stop
About FAN operation
In FAN operation mode, the unit will not operate in COOL or HEAT mode but only in FAN mode ,AUTO is not available in FAN mode.And temp.setting is disabled. In FAN mode,SLEEP operation is not available.
Press on/off button(" "), the unit stops.
AUTO
LOW
MED
HI
COOL DRY FAN HEAT
Remote controller
Operation
1. Unit start
Press on/off button (" ") on the remote controller, unit starts.
12
SWING
CODE
TEMP
LOCK RESETLIGHT
TIMER
SET
CLOCK
FRESHSLEEP
MODE
HEALTH FAN
H.AIR.
Operation
2.Select operation mode
Press FAN button. For each press, fan speed changes as follows:
Press MODE button. For each press, operation mode changes as follows:
Remote controller:
Remote controller:
Then Select HEAT operation
Press TEMP. button
Every time the button is pressed, temp.setting increase 1oC,if kept depressed, it will increase rapidly
Every time the button is pressed, temp.setting decrease 1oC,if kept depressed, it will decrease rapidly
Select a desired temperature.
4.Fan speed selection
3.Select temp.setting
5.Unit stop
Press on/off button (" "), the unit stops.
AUTO
LOW
MED
HI
AUTO
COOL DRY FAN HEAT
Heat Operation
Remote controller
1. Unit start
Air conditioner is running under displayed fan speed IN HEAT mode, warm air will blow out after a short period of the time due to cold-draft prevention function.
When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.
Press on/off button (" ") on the remote controller, unit starts.
13
SWING
CODE
TEMP
LOCK RESETLIGHT
TIMER
SET
CLOCK
FRESHSLEEP
MODE
HEALTH FAN
H.AIR.
2.Up and down air flow direction
Vertical flap
Pos.1
Pos.1 Pos.2 Pos.3 Pos.4 Pos.6
Pos.5 Pos.4 Pos.3 Pos.2 Pos.1 Pos.6
Pos.1 Pos.2 Pos.3 Pos.4 Pos.5 Pos.6
Pos.2
Pos.3
Pos.4
Pos.5
Pos.6
(Auto swing)
For each press of button, air flow direction on remote controller displays as follows according to different operation modes:
remote controller:
COOL/DRY/FAN :
remote controller:
remote controller:
The vertical flap will swing according to the above positions
HEAT:
AUTO:
1.Status display of air sending
Horizontal louvers
Pos.1
Pos.2
Pos.3
Pos.4
Pos.5
Pos.6
Pos.7
Pos.8
3.Left and right air flow direction
For each press of button, remote controller displays as follows :
remote controller:
Pos.1 Pos.2 Pos.3 Pos.4 Pos.5 Pos.6 Pos.7 Pos.8
The horizontal louvers will swing according to the above positions.
Note:When restart after remote turning off, the remote controller will automatically memorize the previous set swing position.
Air Flow Direction Adjustment
Operation
14
SWING
CODE
TEMP
LOCK RESETLIGHT
TIMER
SET
CLOCK
FRESHSLEEP
MODE
HEALTH FAN
H.AIR.
If the wind speed is high or middle before setting for the sleep, set for lowing the wind speed after sleeping. If it is low wind, no change.
5.Set the wind speed change when sleeping
Before going to bed, you can simply press the SLEEP button and unit will operate in SLEEP mode and bring you a sound sleep. Use of SLEEP function After the unit starts, set the operation status, then press SLEEP button before which the clock must be adjusted and time being set. Operation Mode
1. In COOL,DRY mode 1 hours after SLEEP mode starts, temp. will become 1OC higher than temp. setting. After another 1 hours, temp. rises by 1OC further. The unit will run for further 6 hours then stops. Temp. is higher than temp. setting so that room temperature won't be too Iow for your sleep.
Remote Controller
SLEEP operation starts SLEEP operation stops
SLEEP operation starts
SLEEP operation stops
Approx.6hrs
1 hr
1 hr
1 hr
3 hrs
3 hrs
Rises 1OC
Rises 1OC
Rises 1OC
Temp.setting
Temp.setting
Unit stop
Unit stop
In COOL, DRY mode
In HEAT mode
Decreases 2OC
Decreases 2OC
1 hr
Sleep Operation
2.
3.
In HEAT mode 1 hours after SLEEP mode starts, temp will become 2 OC lower than temp. setting. After another 1 hours, temp decrease by 2 OC further. After more another 3 hours, temp. rises by 1OC further. The unit will run for further 3 hours then stops. Temp. is lower than temp. setting so that room temperature won't be too high for your sleep.
In AUTO mode The unit operates in corresponding sleep mode adapted to the automatically selected operation mode.
4. In FAN mode It has no SLEEP function.
Operation
15
SWING
CODE
TEMP
LOCK RESETLIGHT
TIMER
SET
CLOCK
FRESHSLEEP
MODE
HEALTH FAN
H.AIR.
Remote Controller
Timer On/Off Operation
Operation
Hints: After replacing batteries or a power failure happens, time setting should be reset. Remote controller possesses memory function, when use TIMER mode next time, just press SET button after mode selecting if time setting is the same as previous one.
Set clock correctly before starting TIMER operation.
1. After unit starts, select your desired operation mode Operation mode will be displayed on LCD.
2. Timer mode selection Press TIMER button to change TIMER mode. Every time the button is pressed, display changes as follows: Remote controller:
BLANK
TIMER ON TIMER OFF TIMER ON-OFF
Then select your desired TIMER mode (TIMER ON or TIMER OFF). " "or " "will flash.
3.Time setting
Press HOUR button. Every time the button is pressed, time setting increases 1 min, if kept depressed, it will increase rapidly. Every time the button is pressed, time setting decreases 1 min, if kept depressed, it will decrease rapidly. It can be adjusted within 24 hours.
4.Confirming your setting
After setting correct time, press SET button to confirm " "or" "on the remote controller stops flashing. Time displayed: Unit starts or stops at x hour x min. (TIMER ON or TIMER OFF).
5.Cancel TIMER mode
Just press TIMER button several times until TIMER mode disappears.
16
SWING
CODE
TEMP
LOCK RESETLIGHT
TIMER
SET
CLOCK
FRESHSLEEP
MODE
HEALTH FAN
H.AIR.
Remote Controller
Timer On-Off Operation
Operation
Just press TIMER button several times until TIMER de disappears. According to the Time setting sequence of TIMER ON or TIMER OFF, either Start-Stop or Stop-Start can be achieved.
Set clock correctly before starting TIMER operation.
1. After unit starts, select your desired operation mode Operation mode will be displayed on LCD.
2. Timer mode selection Press TIMER button to change TIMER mode. Every time the button is pressed, display changes as follows: Remote controller:
BLANK
TIMER ON TIMER OFF TIMER ON-OFF
Then select your desired TIMER mode (TIMER ON - OFF). " "will flash.
3.Time setting
Press HOUR button. Every time the button is pressed, time setting increases 1 min, if kept depressed, it will increase rapidly. Every time the button is pressed, time setting decreases 1 min, if kept depressed, it will decrease rapidly. It can be adjusted within 24 hours.
4.Timer confirming for TIMER ON
After setting correct time, press TIMER button to confirm " " on the remote controller stops flashing. " " starts flashing. Time displayed: Unit starts or stops at x hour x min.
5.Time setting for TIMER OFF
6.Time confirming for TIMER OFF
To cancel TIMER mode
Just press HOUR button ,follow the same procedure in "Time setting for TIMER ON"
After time setting,press SET button to confirm. " " on the remote controller stops blinking. Time displayed:Unit stops at x hour x min.
17
SWING
CODE
TEMP
LOCK RESETLIGHT
TIMER
SET
CLOCK
FRESHSLEEP
MODE
HEALTH FAN
H.AIR.
POWER/SOFT Operation
POWER
Operation
POWER Operation
SOFT Operation
When you need rapid heating or cooling, you can use this function.
You can use this function when silence is needed for rest or reading.
Selecting of POWER operation
Press POWER/SOFT button. Every time the button is pressed,display
In HEAT or COOL mode, compressor runs in high frequency for 15 min then returns to original status setting.
Press POWER/SOFT button twice ,POWER/SOFT disappears.
In SOFT operation mode, fan speed automatically takes"ultra-low"
changes as follows:
Stop the display at
SOFT
BLANK
POWER
Press POWER/SOFT button. Every time the button is pressed,display
changes as follows:
Stop the display at
SOFT
BLANK
In POWER operation status:
Selecting of SOFT operation
To cancel POWER operation
Press POWER/SOFT button twice ,POWER/SOFT disappears.
To cancel SOFT operation
Hints: During POWER operation, in rapid HEAT or COOL mode, the room will show inhomogeneous temperature distribution. Long period SOFT operation will cause effect of not too cool or not too warm.
Remote controller
18
SWING
CODE
TEMP
LOCK RESETLIGHT
TIMER
SET
CLOCK
FRESHSLEEP
MODE
HEALTH FAN
H.AIR.
1.Press ON/OFF button (" ") to starting
Operation
The liquid crystal will display the working state of last time (Except timer, sleeping, power/soft and health airflow). Setting the comfort work conditions.
2.The setting of health airflow function
1).Press the button of health airflow, appears on the display. The nether inlet and outlet grills of the air condit­ioner are closed and the airflow is blown horizontally from the above inlet and outlet grills. Avoid the strong airflow blows direct to the body.
2).Press the button of health airflow again, appears on the display. The above inlet and outlet grills of the air cond­itioner are closed and the airflow is blown vertically from the nether inlet and outlet grills. Avoid the strong airflow blows direct to the body.
Note: 1 .After setting the health airflow function, the position of inlet and outlet grills is fixed.
2.In heating, it is better to select the mode.
3.In cooling, it is better to select the mode.
4.In cooling and dry, using the air conditioner for a long time under the high air humidity, a phenomenon falling drips of water occurs at the outlet grille .
5.Select the appropriate fan direction according to the actual conditions.
3.The cancel of the health airflow function
Press the button of health airflow again, both the inlet and outlet grills of the air conditioner are opened, and the unit goes on working under the condition before the setting of health airflow function. After stopping, the outlet grille will close automatically. Notice: Cannot pull direct the outlet grille by hand. Otherwise, the grille will run incorrectly. If the grille is not run correctly, stop for a minute and then start, adjusting by remote controller.
Health airflow Operation
Remote controller
19
When the remote controller is manipulated, it gets the system back to the normal operation mode.
Emergency and Test Operation
Operation
Emergency operation:
Use this operation only when the remote controller is defective or lost.
When the emergency operation switch is pressed,the" Pi "sound is heard once, which means the start of this operation.
In this operation, the system automatically selects the operation modes, cooling or heating, according to the room temperature.
Test operation:
Test operation switch is the same as emergency switch.
Use this switch in the test operation when the room temperature is below 16OC, do not use it in the normal operation.
Continue to press the test operation switch for more than 5 seconds. After you hear the "Pi" sound twice, release your finger from the switch: the cooling operation starts with the air flow speed "Hi".
Removal of the restriction of emergency or test operation
Press the emergency operation switch once more, or manipulate through the remote controller; the "Pi" sound, the emergency or test operation is terminated.
It is not possible to operate in dry mode.
Temperature
Operation mode
Designated temperature
Timer mode
Air flow
ABOVE 23OC BELOW 23OC
COOLING HEATING
23OC
26OC
NO
NO
AUTOMATIC
AUTOMATIC
After 30 minutes, test operation ends automatically.
20
For Smart Use of The Air Conditioner
Setting of proper room temperature
Close doors and windows during operation
If the unit is not to be used for a long time, turn off the power supply main switch.
Use the timer effectively
Use the louvers effectively
Do not block the air inlet or outlet
Maintenance
Proper temperature
During cooling operation prevent the penetration of direct sunlight with curtain or blind
OFF
21
For Smart Use of The Air Conditioner
WARNING
Air Filter cleaning
Open the inlet grille by pulling it upward.
Remove the filter.
Clean the filter.
Attach the filter.
Close the inlet grille.
Push up the filter's center tab slightly until it is released from the stopper, and remove the filter downward.
Use a vacuum cleaner to remove dust, or wash the filter with water.After washing, dry the filter completely in the shade.
Attach the filter correctly so that the "FRONT" indication is facing to the front.Make sure that the filter is completely fixed behind the stopper.If the right and left filters are not attached correctly, that may cause defects.
Remote Controller
Do not use the following for cleaning
Do not use water, wipe the controller with a dry cloth.Do not use glass cleaner or chemical cloth.
Gasoline,benzine, thinner or cleanser may damage the coating of the unit.
Hot water over 40OC(104OF) may cause discoloring or deformation.
Wipe the air conditioner by using a soft and dry cloth.For serious stains,use a neutral detergent diluted with water.Wring the water out of the cloth before wiping.then wipe off the detergent completely.
Indoor Body
Before maintenance,be sure to turn off the system and the circuit breaker.
Maintenance
Once every two weeks
22
The green aspect of the bacteria-killing medium air purifying filter will face outside, the white aspect will face to the machine.
1.For the units with UV light degerming function,the air purifying filter of the bacteria-killing medium and the multi-lights touching intermediary is effective for a long time and don't need to be changed (UV light emitted by the UV light device of the indoor unit catalytically activates the nano TiO2 on the multi-lights touching intermediary, and the degerming effect is highly efficient and lasting. multi-lights touching intermediary don't need to be exposed to the sunlight.).
2.For the units without UV light degerming function,the air purifying filter of the multi-lights touching intermediary will be solarized in fixed time. In normal family,it will be solarized every 6 months. The solarization time will last no less than 8 hours under the state of abundant sun.
3.But in the use, please note to clean the filter frequently (take off the back suction cleaner or lightly pat it) to avoid the operating effect is lowered due to the dust covering the filter. Multi-lights touching intermediary and bacteria-killing medium filter is strictly prohibited from being cleaned by water.
Common sense:
The the bacteria-killing medium filter not in use should be stored in shade, cool and dry place. Please don't expose it to the sunlight for a long time otherwise the degerming performance will drop.
Note: the bacteria-killing mediums placed on the right side. the multi-lights touching intermediary is placed on the left side.
Maintenance
1.Open the lnlet Grille
2.Detach the standard air filter
3.Attach old Air Purifying Filter
4.Attach the standard air filter
(Necessary installation)
5.Close the Inlet Grille
Close the Grille surely
Open the inlet grille by pushing each ends of the inlet grille upward.(use thumbs to push up)
Slide the knob slightly upward to release the filter, then withdraw it.
Put air purifying filter appliances into the right and left filter frames.
Detach old Air Purifying Filter
Replancement of Air Purifying Filter
23
To Keep Your Air conditioner in Good Condition after Season.
Operate in cooling mode for 2-3 hours.
Put off the power supply cord.
Take out the batteries from the wireless remote controller.
Cleaning the body.
To prevent breeding mold or bad smell, be sure to operate at the designated temperature or 30OC,cooling mode and High speed fan mode for 2-3 hours.
Maintenance
24
Before Setting in High season
Cleaning the standard air filter.
Connecting the earthing cable.
Do not block the air inlet or outlet.
Plug-in
Caution
Caution
After brush away dust at the plug, insert the plug of the power supply cord into the outlet completely.In case of suing exclusive circuit breaker,switch on the circuit breaker.
NO WET HAND
EARTHING
Operation without filter may cause troubles.Be sure to attach both right and left filters prior to the operation. Each of them are of different shapes.
Incomplete earthing may cause an electric shock.
Maintenance
25
Is the air filter dirty? Normally it should be cleaned every 15 days. Are there any obstacles before inlet and outlet? Is temperature set correctly? Are there some doors or windows left open? Is there any direct sunlight through the window during the cooling operation?(Use curtain) Are there too much heat sources or too many people in the room during cooling operation?
Cause or check points
Phenomenon
The system does not restart immediately.
Noise is heard:
Smells are generated.
Mist or steam are blown out.
Does not work at all.
Multiple check
Normal Performance inspection
Poor cooling
Before asking for service, check the following first.
When unit is stopped, it won't restart immediately until 3 minutes have elapsed to protect the system. When the electric plug is pulled out and reinserted, the protection circuit will work for 3 minutes to protect the air conditioner.
During unit operation or at stop, a swishing or gurgling noise may be heard. At first 2-3 minutes after unit start, this noise is more noticeable. (This noise is generated by refrigerant flowing in the system.) During unit operation, a cracking noise may be heard. This noise is generated by the casing expanding or shrinking because of temperature changes. Should there be a big noise from air flow in unit operation, air filter may be too dirty.
This is because the system circulates smells from the interior air such as the smell of furniture, cigarettes.
During COOL or DRY operation, indoor unit may blow out mist. This is due to the sudden cooling of indoor air.
Is power plug inserted? Is there a power failure? Is fuse blown out?
Trouble shooting
26
Antes de eliminar un aire acondicionado que se ha dejado de utilizar, verificar que está inoperativo y seguro. Desenchufar el aire acondicionado con el fin de evitar el riesgo de que quede atrapado algún niño.
Hay que señalar que el sistema de aire acondicionado contiene refrigerantes, que requieren una eliminación especializada en vertederos. Los materiales valiosos contenidos en un aire acondicionado pueden reciclarse. Ponerse en contacto con el centro local de eliminación de residuos para desechar adecuadamente el aire acondicionado viejo y ponerse en contacto con el proveedor o la autoridad local en caso de duda. Verificar que los conductos del aire acondicionado no están dañados antes de que éste sea recogido por el centro de eliminación de residuos correspondiente y contribuir a la concienciación medioambiental insistiendo en un método de eliminación apropiado contra la contaminación.
Eliminación del aire acondicionado viejo
Todos los materiales de embalaje utilizados en el embalaje de su aire acondicionado nuevo pueden eliminarse sin peligro para el medio ambiente.
La caja de cartón puede romperse o cortarse en trozos más pequeños y enviarse a un servicio de reciclaje de papel. La bolsa del envoltorio está formada de polietileno y bloques de espuma de polietileno.
Todos estos materiales valiosos pueden llevarse a un centro de recogida de residuos y volver a utilizarse después de un reciclaje adecuado.
Consultar a las autoridades locales el nombre y la dirección de los centros de recogida de materiales residuales y los servicios de reciclaje de papel más cercanos al domicilio.
Eliminación del embalaje del aire acondicionado nuevo
Antes de poner en marcha el aire acondicionado, leer detenidamente la información que aparece en la Guía del Usuario. La Guía del Usuario contiene observaciones muy importantes en relación con el montaje, la utilización y el mantenimiento del aire acondicionado.
El fabricante no acepta ninguna responsabilidad por los daños que puedan surgir debido al incumplimiento de la siguiente instrucción.
Instrucciones de seguridad y advertencias
Los aires acondicionados dañados no deben ponerse en marcha. En caso de duda, consultar al proveedor.
La utilización del aire acondicionado debe
efectuarse cumpliendo estrictamente las instrucciones correspondientes señaladas en la Guía del Usuario.
La instalación debe ser efectuada por profesionales; no instalar la unidad por propia cuenta y riesgo.
Por razones de seguridad, el aire acondicionado debe disponer de una toma de tierra adecuada conforme a las especificaciones.
No olvidar desenchufar el aire acondicionado antes de abrir la rejilla de entrada. No desenchufar jamás el aire acondicionado tirando del cable de alimentación. Sujetar siempre con firmeza el enchufe y tirar de él recto en relación con la toma.
Todas las reparaciones eléctricas deben ser efectuadas por electricistas cualificados. Las reparaciones inadecuadas pueden constituir una fuente importante de peligro para el usuario del aire acondicionado.
No dañar ninguna pieza del aire acondicionado que lleve refrigerante ni perforando ni agujereando los tubos del aire acondicionado con elementos afilados o puntiagudos, ni aplastando ni retorciendo ningún tubo, ni descascarillando los recubrimientos de las superficies. Si se produce una fuga de refrigerante y entra en contacto con los ojos, puede provocar graves lesiones oculares.
Precauciones
27
1.Rango aplicable de temperatura ambiente:
Refrigeración
Interior
Máximo:D.B/W.B
Máximo:D.B/W.B Mínimo:D.B
Máximo:D.B Mínimo:D.B
Mínimo:D.B/W.B
Máximo:D.B/W.B Mínimo:D.B/W.B
Exterior
Interior
Exterior
Calefacción
Especificaciones
La máquina puede adaptarse a las siguientes condiciones
32oC/23oC
24oC/18oC
-15oC
43oC/26oC 18oC
27oC 15oC
18oC/14oC
No obstaculizar ni tapar la rejilla de ventilación del aire acondicionado. No poner los dedos ni ningún otro elemento en la entrada/salida ni en la lama giratoria.
No dejar que los niños jueguen con el aire acondicionado. En ningún caso se debe permitir a los niños que se sienten sobre la unidad exterior.
El circuito de refrigeración es a prueba de fugas.
7. El electrodoméstico no está diseñado para ser utilizado por menores o personas discapacitadas sin supervisión de un adulto
8. Debe controlarse a los menores para que no jueguen con el aparato de aire acondicionado.
9. Utilizar el enchufe de corriente adecuado que se ajuste al cable de alimentación a la red.
10 El enchufe y el cable de red deben cumplir
la legislación local aplicable
2. Si el cable de alimentación está dañado, debe ser sustituido por el fabricante o su distribuidor autorizado o una persona con cualificación similar.
4. El método de cableado debe ser conforme a la norma local sobre cableado.
5. Después de la instalación, se debe poder llegar con facilidad al enchufe de red.
6. La pila agotada debe eliminarse de forma adecuada.
11 Para proteger los equipos, por favor apagar primero el acondicionador de aire y al menos 30 segundos después, cortar
la red.
Precauciones
3. Si el fusible de la unidad interior de la placa PC está roto, cambiarlo por uno del tipo T
3.15A /250V. Si el fusible de la unidad exterior
está roto, cambiarlo por uno del tipo T.25A/250V.
28
CUMPLIMIENTO
ESTRICTO
Instalación
Se ruega leer detenidamente las instrucciones de seguridad siguientes antes de su uso.
La instalación en un lugar no adecuado puede provocar accidentes. No instalar en los siguientes lugares.
Conectar el cable de tierra.
a tierra
No instalar en un lugar donde exista la más mínima posibilidad de fugas de gas inflamable alrededor de la unidad.
No exponer la unidad a chorros de vapor o de aceite
Comprobar la instalación correcta de las tuberías de desagüe
PROHIBICIÓN
PRECAUCIÓN
Las instrucciones están clasificadas en dos niveles, ADVERTENCIA y PRECAUCIÓN según la gravedad de los posibles riesgos y lesiones que pueden provocar. Es absolutamente necesario el cumplimiento de las instrucciones para un uso seguro.
Póngase en contacto con el tienda/servicio técnico para la instalación. No intente realizar la instalación del aire acondicionado por su cuenta ya que una instalación incorrecta puede provocar descargas eléctricas, incendios o fugas de agua.
PROHIBICIÓN
ADVERTENCIA
Precauciones
Instrucciones de Seguridad
29