Haier HSU-09RR103/R2, HSU-09RR103/R2(SDB), HSU-12RR103/R2(SDB) Operation Manual

Please read this operation manual before using the air conditioner.
0010531024
SPLIT TYPE ROOM AIR CONDITIONER
OPERATION MANUAL
Keep this operation manual for future reference.
Contents
2 3
6 7
1
PARTS AND FUNCTIONS OPERATION
MAINTENANCE
TROUBLE SHOOTING
HSU-09RR103/R2(SDB) HSU-12RR103/R2(SDB)
2
Outdoor Unit
Loading of the battery
1 2
3
4
Parts and Functions
Indoor Unit
OUTLET
INLET
CONNECTING PIPING AND ELECTRICAL WIRING
DRAIN HOSE
Remote controller
Remove the battery cover;
Load the batteries as illustrated.
2 R-03 batteries, resetting key
(cylinder);
Be sure that the loading
is in line with th
e" + "/"-";
Load the battery,then put on the cover again.
Clock set
Press CLOCK button, "AM" or "PM" flashes. Press or to set correct time. Each press
change quickly.
After time setting is confirmed,press SET,
"AM "and "PM" stop flashing,while clock starts working.
or decrease 1min. If the
button is kept pressed,time will
will increase
The distance between the signal transmission head and the rece­iver hole should be within 7m without any obstacle as well.
When electronic-sta rted type fluorescent lamp or change- over
wireless telephone is installed in the
ver is apt to be disturbed in receiving
the signals,
so the distance to the indoor unit should be shorter.
type fluorescent lamp or room, the recei
Note:
Full display or unclear display during operation indicates the
ries have been used up.
Please change batteries.
If the remote controller can't run normally during operation, please
reload several minutes later.
batte
remove the batteries and
Remove the batteries in case unit won't be in usage for a long period.
If there are any display
after taking-out, just need to press reset key.
Hint:
Please be subject to the actual produce purchased the above picture is just from your reference
Please be subject to the actual produce purchased the above picture is just from your reference
air ionization purify layer
Inlet
Horizontal louver(inside)
Inlet grille
Power plug
(adjust left and right air flow)
Outlet
Air filter(inside)
display board (inside)
(inside)
Anion generator
(inside)
Vertical flap (adjust up and down air flow
.
Don’t adjust it manually)
Vitamin C layer+Bacteria-killing medium sets(inside)
TEMP display
COOL display
HEAT display
Dry display
TIMER OFF display
TIMER ON display SLEEP display
AUTO display
Remote signal receiver
Emergenc
y operation
Used to set emergency operation and test operation.
button(touch key)
Used to set air ionization purify and healthy function.
9. Purify button
10. ON/OFF button 11
. TIMER ON display
13. LOCK display
14
. SWING UP/DOWN display
15
. SLEEP display
16
. HEALTH display
17. Operation mode display
19. POWER/SOFT display 20
. Left/right air flow display
21. TEMP display 22
. TIMER OFF display
23
. CLOCK display
24
. TEMP button
25. FAN button
26. HEALTH AIRFLOW button 27
. SWING UP/DOWN button
28. SWING LEFT/RIGHT button
29.
FRESH
button(optional)
30. SET button 31
. POWER/SOFT button
1.TEMP/HUM DISP
When the remote controller appears abno rmal, use a sharp pointed article to press this button to reset the remote controller normal.
2.RESET
4. TIMER button
5. CLOCK button
6. SLEEP button
7. MODE button
8.
button
32. LOCK
18.Singal sending display
3.LIGHT button
Control the lightening and extinguishing of the indoor LED display board.
28
19
A B
33
32
1
Used for the display panel to choose displaying the actual
present.
temperature or the actual humidity at
TEMP/HUM
Operation mode
AUTO
HEATFAN
COOL DRY
Remote controller
33.
10
ć
Low-Temperature Heating Operation Down to 10
ć
Used to lock buttons and LED display.If pressed,the other buttons will be disabled and the lock condition display appears. Press it once again,lock will be canceled and lock condition display disappears
12
.FAN SPEED display
LOW HI
MED
AUTO
Used for adjusting humidity or clock time and timed time.
NOTE: Humidity adjusting for this series is not available.
3
AUTO COOL DRY FAN HEAT
2.Select operation mode
Press FAN button. For each press, fan speed
follows:
Press MODE button. For each press, operation mode changes as follows:
Remote controller:
Remote controller:
Press button
Every time the button is pressed, temp.setting increase 1
o
C,if kept depressed, it will increase
rapidly
Every time the button is pressed, temp.setting
decrease 1
o
C,if kept depressed, it will
decrease rapidly
Select a desired temperature.
4.Fan speed selection
3.Select temp.setting
Air conditioner is running under displayed fan speed. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.
LOW
MED
HI
AUTO
1. Unit start
Press ON/OFF on the remote controller, unit starts.
Base Operation
Remote controller
Emergency Operation:
temperature is below 16
o
C, do not use it in the
Test operation:
Use this switch in the test operation when the room
normal operation.
your finger from the switch: the cooling
Continue to press the test operation
switch for more than 5 seconds . After
you hear the "Pi" sound twice,
release
Test ope ration switch is the same as emergency switch.
operation starts with the air flow speed "Hi".
Emergency operation and test operation
Use this operation only when the remote controller is defective or lost.
When the emergency ope
ration switch is
pressed,the" Pi "sound is heard once
, which
the start of this operation.
In this ope
ration, the system automatically selects
the
operation modes
,cooling or fan or heat,
according to the room temperature.
.
It is not possible to operate in dry mode.
Room
temperature
Operation mode
Designated temperature
Timer
mode
Air flow
ABOVE 23
O
C
BELOW 23
O
C
COOLING
HEAT
23
O
C
26
O
C
NO
NO
AUTOMATIC
AUTOMATIC
(C
ooling only uint˅
Room temperature
Operation
mode
Designated temperature
Timer mode
Air flow
BELOW 23
O
C
FAN
26
O
C
NO
AUTOMATIC
Pi
means
changes as
Unit won't restart until 3 minutes have
elapsed, due to
HEAT mode is not available on
cooling only unit.
It is advisable not to keep vertical flap at
downward position
or DRY mode, otherwise,
water might occur.
Cautions:
When humidity is high, condensate water
might occur at
louvers are adjusted to left or right.
for a long time in COOL
air outlet if all horizontal
system protection.
condensate
Vertical flap
Pos.1
Pos.2
Pos.3
Pos.4
Pos.5
Pos.6
(Auto swing)
1.Status display of air flow
2.Left and right air flow adjustment
(manual)
Pos. 1
Pos. 2
Pos. 3
Pos. 4
Pos. 5
Pos. 6
Pos. 7
Pos. 8
For each press of button, remote controller displays as follows :
remote controller:
Operation
Mode
AUTO
Display
Board
Remote
Controller
Note
COOL
DRY
HEAT
FAN
nothing
Under the mode of auto operation, air conditioner will automatically select Cool or Heat operation according to room temperature. air conditioner
automatically adjusts the fan speed
temperature.
When FAN is set to AUTO, the
according to room
In FAN operation mode, the unit will not operate in COOL or HEAT mode but only in FAN mode ,AUTO is not available in FAN mode.And temp.setting is disabled. In FAN mode,SLEEP operation is not available.
Operation
Air Flow Direction Adjustment
Pi
Pi
Loading...