Haier HSU-12RM03/R2, HSU-18RM03/R2, HSU-24RM03/R2, HSU-09RM03, HSU-12RM03 Operation Manual

...
No.0010561788
Please read this operation manual before using the air conditioner.
SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL
HSU-09RM03/R2 HSU-12RM03/R2 HSU-18RM03/R2 HSU-24RM03/R2
1 2-5
6-14
15-17
18
Contents
Parts and functions Operation
Maintenance Trouble shooting
1.Applicable ambient temperature range:
The machine is adaptive in following situation
1
Cautions
3. If the fuse on PC board is broken please change it with the type of T. 3.15A/250V.
4. The distance between the indoor unit and the floor should be more than 2m.
5. The wiring method should be in line with the local wiring standard.
6. After installation, the power plug should be easily reached.
7. The waste battery should be disposed properly.
8. The appliance is not intended to use by young children or infirm persons without supervision.
9.Young children should be supervised ensure that they do not play with the appliance.
10.The appliance must be installed on strong enough supporter.
11.The wiring diagram is attached inside the machine.
12.For model HSU-24RM03/R2, the breaker of the air conditioner should be an air gap contact. Such means for disconnection must be incorporation in the fixed wiring according to the wiring rules.
2. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. The type of connecting wire is H05RN-F or H07RN-F
Cooling
Heating
Indoor
Outdoor
Indoor
Outdoor
Maximum: D.B / W.B Minimum: D.B / W.B
Maximum: D.B Minimum: D.B
Maximum: D.B Minimum: D.B
Maximum: D.B / W.B Minimum: D.B / W.B
32oC/23oC 18oC/14oC
43oC/26oC 18oC
27oC 15oC
24oC/18oC
-7oC/-8oC
2
Parts and Functions
Indoor Unit
HSU-09RM03/R2For models:
HSU-24RM03/R2For models:
HSU-12RM03/R2 HSU-18RM03/R2
Inlet grille
Air filter
Vertical flap
Use remote controller to adjust up and down air flow. (Don't adjust it manually.)
Power indicator
Lights up when unit starts.
Timer mode indicator
Lights up when Timer operation is selected.
Operation mode indicator
Remote signal receiver
Emergency switch(manual)
Test running switch(manual)
Lights up during compressor running.
A beeping sound is generated when a signal from remote controller is received.
Used when remote controller is lost or defective. Unit will run temporarily.
Used only for test running in cooling when room temp. is below 16oC. Don't use it in normal operation.
Actual inlet grille may vary from the one shown in the manual according to the product purchased.
Inlet grille
Air filter(inside)
Vertical flap
Use remote controller to adjust up and down air flow. (Don't adjust it manually.)
Remote signal receiver
A beeping sound is generated when a signal from remote controller is received.
Operation mode indicator
Lights up during compressor running.
Timer mode indicator
Lights up when Timer operation is selected.
Power indicator
Lights up when unit starts.
Parts and Functions
Outdoor Unit
3
OUTLET
INLET
CONNECTING PIPING AND ELECTRICAL WIRING DRAIN HOSE
HSU-24RM03/R2
HSU-09RM03/R2 HSU-12RM03/R2 HSU-18RM03/R2
4
Parts and Functions
FAN
DRY HEAT
COOL
AUTO
AUTO
LO
MED
HI
Operation
1. Mode display
2. SWING display
3. FAN SPEED display
4. SLEEP display
5. LOCK display
6. SIGNAL SENDING
7. TIMER OFFdisplay
8. TIMER ON display
9. CLOCK display
10. TEMP display
11. POWER ON/OFF
Used for unit start and stop.
12. MODE
Used to select AUTO run, COOL, DRY, HEAT and FAN operation
13. FAN
Used to select fan speed LO, MED, HI, AUTO
14. HOUR
Used to set clock and timer setting.
15. SWING
Used to set auto fan direction.
16. SLEEP
Used to select sleep mode.
17. LOCK
Used to lock buttons and LCD display.
18. TEMP.
Used to select your desired temp.
19. SET
Used to confirm timer and clock settings.
20. TIMER
Used to select TIMER ON, TIMER OFF, TIMER ON-OFF
21. CLOCK
Used to set correct time
22. RESET
normal condition.
Used to reset the controller back to
Clock set
When unit is started for the first time and after replacing batteries in remote controller, clock should be adjusted as follows: Press CLOCK button, "AM" or "PM" flashes. Press or to set correct time. Each press will increase or decrease 1min. If the button is kept depressed, time will change quickly. After time setting is confirmed, press SET, "AM "and "PM" stop flashing, while clock starts working.
Hints
After replacing with new batteries, remote controller will conduct self-check, displaying all information on LCD. Then, it will become normal.
ON/OFF
TEMP
MODE SET
FAN
TIMER
SWING
CLOCK
SLEEP
LOCK RESET
NOTE: Cooling only unit do not have displays and functions related with heating
4
1
2 3
11
12
13 14
15
16
17
18
20
5 6
7
8
9
10
19
21
22
ON OFF
AM PM
o
C
A U T O
Buttons and display of the remote controller.
Loading...
+ 14 hidden pages