Driverƽ
Nipperƽ
HacksawƽPipe cutterƽ
Hole core drillƽFlaring toolƽ
Spanner(17,19 and 26mm)ƽKnifeƽ
Gas leakage detector orƽ
soap-and-water solution
ƽ
(17mm,2 2mm, 26mm)
Measuring tapeƽ
Reamerƽ
Power Source
ƽ
Before inserting power plug into receptacle, check the voltage without fail.
The power
Install an exclusive branch circuit of the power.
ƽ
Areceptacleshallbesetupin a distancewherethepowercablecanbe
ƽ
reached.
sourceisthesameasthe
Donotextendthecablebycuttingit.
correspondingnameplate.
Drawing for the installation of indoor and outdoor units
ThemodelsadoptHFCfreerefrigerantR410A
more than 5cm
more than
10cm
Selection of Installation Place
Indoor Unit
Place, robust not causing vibration, where the body can be supported sufficiently.ƽ
Place, not affected by heat or steam generated in the vicinity, where inlet and outlet of the
ƽ
unit are not disturbed.
Place, possible to drain easily, where piping can be connected with the outdoor unit.ƽ
Place,wherecoldaircanbespreadin a roomentirely.ƽ
Place, nearby a power receptacle, with enough space around. (Refer to drawings).ƽ
Place where the distance of more than lm from televisions, radios, wireless apparatuses
ƽ
and fluorescent lamps can be left.
In the case of fixing the remote controller on a wall, place where the indoor unit can
ƽ
receivesignalswhenthefluorescent
lampsintheroomarelightened.
Outdoor Unit
Place, which is less affected by rain or direct sunlight and is sufficiently ventilated.ƽ
Place,possibletobeartheunit,wherevibrationandnoisearenotincreased.ƽ
Place, where discharged wind and noise do not cause a nuisance to the neighbors.ƽ
Place, where a distance markedƽ
Attention must be paid to
the rising up of drain hose
is available as illustrated in the above figure.
Optional parts for piping
Non-adhesive tape
A
Adhesive tape
B
Saddle (L.S) with screws
G
C
Connecting electric cable
D
for indoor and outdoor
E
Drain hose
F
Heating insulating material
Piping hole cover
G
Arrangement of piping
directions
Left
Rear left
Rear
more than 10cm
A
F
Floor fixing dimensions of the
outdoor unit (Unit:mm)
right
Right
Below
C
more than
10cm
Fixing of outdoor unit
ƽ
D
The marks fromto
ƽ
G
inthefigurearethe
parts numbers.
Thedistancebetween
ƽ
the indoor unit and the
more than 10cm
A
floor should be more
than 2m.
more than
E
ƽ
60cm
more than15cm
Please be subject to the actual product purchased , the above picture is just for your reference.
Read this manual before installation
Explain sufficiently the operating means to the user according to this manual.
NO.0010531116
Fix the unit to concrete or blockƽ
with bolts (10mm) and nuts firmly
and horizontally.
When fitting the unit to wall
surface, roof or rooftop, fix
a supporter surely with nails
or wires in consideration of
earthquakeandstrongwind.
If vibration may affect the
house, fix the unit by attaching a
vibration-proof mat.
Accessory parts
Remote controller (1)
R-03 dry battery (2)
Mounting plate (1)
Plastic cap (4)
Ø4X25 Screw
(4)
Drainhose(1)
Cushion (4)
Drain-elbow (1)
Pipe supporting plate (1)
Selection of pipe
Liquid pipe (Ø)6.35mm(1/4”)
Gas pipe (Ø)
NOTE˖The thickness of the pipe must be 0.8mm at least.
12.7mm(1/2”)
Indoor unit
FittingoftheMountingPlateand
When the mounting plate is first fixed
1. Carry out, based on the neighboring pillars or lintels, a
to be fixed against the wall, then
2. Make sure once more the proper level of the plate, by
weight from the central top of the plate, then fasten securely the plate with the
attachment steel nail.
3. Find the wall hole location A using a measuring tape
temporarilyfastentheplatewithonesteelnail.
Positioning of the wall Hole
proper leveling for the plate
hanging a thread with a
1. Insert the drain hose into the dent of heat insulation
2. Insert the indoor/outdoor electric cable from backside of
out on the front side, then connect them.
3.Coattheflaringsealfacewithrefrigerantoilandconnect
Cover the connection part with heat insulation materials closely, and make sure
fixing with adhesive tape
In case of left side piping, cut away, with a nipper, the lid for left piping.
In case of left-rear piping, bend the pipes according to the piping direction to
ƽ
the mark of hole for left-rear piping which is marked on heat insulation materials.
2
When connecting the cable, confirm the terminal number of indoor and
Note
outdoor units carefully. If wiring is not correct, proper operation can not
Install according to Drawing for the installation of indoor and
Connection of pipes
Tobend a pipe,givetheroundnessaslargeaspossiblenottocrushthepipe,
ƽ
andthebendingradiusshouldbe30to40
ƽ
Connecting the pipe of gas side first makes working easier.
TheconnectionpipeisspecializedforR410A.ƽ
Half union
Spanner
Becarefulthatmatters,suchaswastesofsands,etc.shallnotenterthepipe.
Thestandardpipelengthis5m.Ifitisover7m,thefunctionoftheunitwillbe
affected. If the pipe has
accordingto20g/m.Butthechargeofrefrigerantmust
sional air conditioner engineer. Before adding additional refrigerant, perform air
purgingfromtherefrigerantpipesandindoorunitusing a vacuum
charge additional refrigerant.
CAUTION
Outdoor unit
Outdoor unit
Flare nut
Tor qu e w ren ch
Indoor unit
B
A
Oil trap
B
A
Forced fastening without careful centering may
damage the threads and cause a leakage of gas.
Liquid side6.35mm(1/4")18N.m
Liquid/Gas side9.52mm(3/8")42 N.m
Gas side 12.7mm(1/2")55N.m
Gas side 15.88mm(5/8")60 N.m
to be lengthened, the refrigerant should be charged,
Outdoor unit
Max.Elevation: Amax=15m
●
In case the elevation A is more●
than 5m, oil trap shoud be
installed every 5~7m
●
Indoor unit
Max. Length: Bmax=25m
In case the pipe length B is●
more than 10m, the refrigerant
should be charged, according
to 20 g/m.
mm or longer.
Pipe Diameter(ǿ)Fastening torque
B
Indoor unit
A
outdoor units
beconductedbyprofes-
pump,then
Connection
Use the same method on indoor unit. Loosen the screws onƽ
insert the plugs fully into terminal block, then tighten the screws.
Insert the cable according to terminal number in the same manner as the indoor
ƽ
unit.
If wiring is not correct, proper operation can not be carried out and controller
ƽ
may be damaged.
Fix the cable with a clamp.ƽ
Attaching Drain-Elbow
If the drain-elbow is used,ƽ
please attach it as figure. (Note:
Only for heat pump unit.)
Purging Method:To use vacuum pump
Detach the service port’s cap of
1.
and 3-way’s, connect the service port into the
for gaugemanifold.
gemanifold into vacuum pump.
Open the handle at Iow in
2.
moves of gause (Iow) reach vacuum condition in a moment, check 1. again.
If the refrigerant of the air conditioner leaks, it is necessary to discharge all the
refrigerant. Vacuumize first, then
neraccordingtotheamountmarkedonthenameplate.
ƽ
Please do not let other cooling medium, except specified one (R410A), or air
enter into the cooling circulation system. Otherwise, there will be abnormal
highpressureinthesystemtomakeitcrackandleadtopersonalinjuries.
Power Source Installation
ƽ
The power source must be exclusively used for air
ƽ
In the case of installing an air conditioner in a moist place,
rth leakage breaker.
ƽ
For installation in other places, use a circuit breaker as far
Cutting and Flaring Work of Piping
ƽ
Pipecuttingiscarriedoutwith a pipecutterandbursmust
ƽ
After inserting the flare nut, flaring work is carried out.
FlaretoolforR410AConventionalflaretool
Clutch-typeclutch-type(Rigid-type) Wing-nut type (Imperial-type)
Please pour water in the drain pan of the indoor unit, and confirm that drainage
ƽ
is carried out surely to outdoor.
In case that the attached drain hose is in a room, please
ƽ
it without fail.
The end is immersed in water.
It waves.
The gap with the
ground is too small.
There is the bad
smell from a ditch
applyheatinsulationto
Refrigerant charge labelƵ
Contains fluorinated greenhouse gases
covered by the Kyoto Protocol
R410A
2
1=
2=
1
1+2=
FE
kg
kg
kg
A
B
C
D
This product contains fluorinated greenhouse gases covered by
the Kyoto Protocol. Do not vent into the atmosphere.
Refrigerant type:R410A
GWP* value:1975
GWP=global warming potential
Please fill in with indelible ink,
• 1 the factory refrigerant charge of the product
• 2 the additional refrigerant amount charged in the field and
• 1+2 the total refrigerant charge
on the refrigerant charge label supplied with the product.
The filled out label must be adhered in the proximity of the product
charging port (e.g. onto the inside of the stop value cover).
A contains fluorinated greenhouse gases covered by the Kyoto
Protocol
B factory refrigerant charge of the product: see unit name plate
C additional refrigerant amount charged in the field
D total refrigerant charge
E outdoor unit
F refrigerant cylinder and manifold for charging
Check for Installation and Test Run
Ƶ
Please kindly explain to our customers how to operate
Ƶ
throughtheinstructionmanual.
Check Items for Test Run
Put check mark
Gasleakfrompipeconnecting?
Heat insulation of pipe connecting?
Are the connecting wirings of indoor and outdoor firmly
inserted to the terminal block?
Is the connecting wiring of indoor and outdoor firmly fixed?
Is drainage securely carried out?
Is the earth line securely connected?
Is the indoor unit securely fixed?
Is power source voltage abided by the code?
Is there any noise?
Isthelampnormallylighting?
Arecoolingandheating(wheninheatpump)performednormally?
Is the operation of room temperature regulator normal?
in boxes
CorrectIncorrect
Lean
Damage of flare CrackPartial Too outside
4
Manual de instalación de aparato de aire acondicionado
j
nóicaraperP
Herramientas necesarias para realizar la instalación
Destornillador Llave dinamométrica (17mm, 22mm,
Alicate Sierra de tubos
Sierra para metales Herramienta de conicidad
Broca de tubo Cuchilla
Llave (17, 19 y 26 mm) Metro
Detector de fugas de gas o agua
jabonosa
26mm)
Avellanador
Fuente de alimentación
Antes de insertar el enchufe de alimentación en la toma, compruebe que el voltaje
no falla. La fuente de alimentación es la que figura en la placa de datos nominales.
Instale el aparato en un circuito dedicado de alimentación.
Debe existir una toma al alcance del cable de alimentación. No trate de prolongar el
cable cortándolo.
Diagrama para la instalación de aparatos interiores y exteriores
Los modelos cumplen la norma R410A sobre refrigerantes libres de HFC
más de 5cm
más de 10cm
Organización de la dirección
de los tubos
Izquierda trasera
Izquierda
Derecha
trasera
Selección del lugar de instalación
Unidad interior
Coloque la unidad sobre una superficie que pueda soportarla correctamente y no
provoque vibraciones.
Asegúrese de que el lugar no se ve afectado por calor o vapor generado en las
cercanías y donde la unidad pueda funcionar sin perturbaciones.
Asegúrese de que el lugar permita un drenaje sencillo y en el que puedan
conectarse los tubos a la unidad exterior.
Asegúrese de que el aire frío pueda distribuirse uniformemente por la sala.
Coloque la unidad interior cerca de una toma de suministro eléctrico con espacio
suficiente alrededor. (Consulte los diagramas).
Coloque la unidad interior de modo que se encuentre a más de 1m de televisiones,
radios, aparatos inalámbricos y lámparas fluorescentes.
En el caso de fijar el control remoto a una pared, colóquelo donde la unidad interior
pueda recibir su señal mientras estén encendidas las lámparas fluorescentes de la
sala.
Unidad exterior
Seleccione el lugar menos afectado por la lluvia o la luz solar directa y
suficientemente ventilado.
Elija un lugar que permita soportar el peso de la unidad y que no amplifique el ruido
y las vibraciones.
Seleccione un lugar en el que los residuos y el viento generado por la unidad no
cause una molestia a los vecinos.
Coloque la unidad en un lugar en el que pueda disponerse de la distancia de
separación marcada con el símbolo , como se muestra en la figura anterior
Debe prestarse
atención a la pendiente
de la manguera de
drena
e
Componentes opcionales para
la instalación de los tubos
A Cinta no adhesiva
○
B Cinta adhesiva
○
C Soporte (L.S) con tornillos
○
D Conexión de cable eléctrico
○
para interior y exterior
E Manguera de drenaje
○
F Material aislante de calor
○
G Cubierta de orificio de
○
entubación
más de 10cm
Dimensiones de fijación al suelo
de la unidad exterior (Unidad:mm)
.
Derecha
Inferior
más de 10cm
más de 10cm
Las marcas comprendidas
A y G en la
entre
ilustración corresponden a
los números de las piezas.
La distancia entre la unidad
interior y el suelo debe ser
superior a 2m.
más de 60cm
más de 15cm
Recuerde que la ilustración anterior podría no reflejar fielmente el producto adquirido y debe utilizarse únicamente como referencia.
Lea este manual antes de la instalación
Explique el uso del aparato al usuario siguiendo las instrucciones de este manual.
Fijación de la unidad exterior
Fije la unidad a un bloque de
cemento con pernos (10mm) y
tuercas firme y
horizontalmente.
Si instala la unidad sobre una
pared, techo o tejado, instale
un soporte con clavos o cables
considerando la posibilidad de
terremotos o viento fuerte.
Si la vibración afectase a la
casa, fije la unidad instalando
una alfombra de absorción de
vibraciones.
5