Haier HSU-12HR03-R2-DB, HSU-09HRA103-R2, HSU-09HR03-R2-DB, HSM12HRAC03-R2-DB, HSM09HRAC03-R2-DB User Manual

...
SPLIT TYPE ROOM AIR CONDITIONER
OPERATION MANUAL
HSU-09HR03/R2(DB) HSU-12HR03/R2(DB) HSM09HRAC03/R2(DB) HSM12HRAC03/R2(DB) HSM18HRAC03/R2(DB) HSU-09HRA103/R2
HSU-12HRA103/R2 HSU-18HRA103/R2
Contents
CAUTIONS
MAINTENANCE
TROUBLE SHOOTING
1 2
3 6 7
Please read this operation manual before using the air conditioner.
Keep this operation manual for future reference.
0010523724
Parts and Functions
Indoor Unit
Inlet
Inlet grille
Outlet
Anion generator
(inside)
Horizontal flap
(adjust up and down air flow Don't adjust it manually)
Actual indoor unit may vary from the one shown
in the manual, according to the product purchased.
Display board
3
1
1
Signal receiver hole
2
COOL display
3
HEAT display
TEMP display
4
2
4
5
6 7
Outdoor Unit
Air Purifying Filter
(inside)
Vertical blade
(adjust left and
right air fl
Display board
5
HEALTH display
(If the unit which you purchased
has healthy function,follow it.
If not,please ignore.)
6
Dry display
TIMER OFF display
TIMER ON display SLEEP display
Emergency
Switch
ow)
7
Remote controller
16
15
14
13
12
11
2
1.CODE Used to select CODE A or B
which
will be displayed on
LCD.
Please select A without
special
explanation.
2.LIGHT button Control the lightening and extinguishing of
the indoor
LED display board.
3. TIMER button
4. CLOCK button
5. SLEEP button
6. MODE button
7. HOUR button
8. HEALTH button
The following functions and related displays are not LIGHT button is not available for HSU-09HRA103/R2 and
HSU-12HRA103/R2.
9. ON/OFF button
17
10. TIMER ON display
11. FAN SPEED display
18
19
20
21
22
LOW HI
MED AUTO
12. LOCK display
13. SWING display
14. SLEEP display
15. HEALTH display
16. Operation mode display
23
Operation mode
24
Remote controller
25
17.Signal sending display
26
18. POWER/SOFT display
27
19.
28
29
30
TEMP display
20.
TIMER OFF display
CLOCK display
21.
22.
TEMP button
23.
FAN button
24.
SWING button
HEALTH AIRFLOW button
25..
FRESH
26. SET button
27.
28.
POWER/SOFT button LOCK
29.
AUTO FANCOOL DRY
button
button
If pressed, the other buttons
be disa
will
.Press it once
bled
again,lock will be cancelled.
30.
RESET
button
When the remote controller
appears abnormal,use a
sharp pointed article to press
this button to reset the remote
controller normal.
avai
lable:
HEAT
1
26
OUTLET
INLET
CONNECTING PIPING AND ELECTRICAL WIRING
DRAIN HOSE
4
Clock set
Press CLOCK button, "AM" or "PM" flashes. Press or to set correct time. Each press
or decrease 1min. If the
change quickly.
"AM "and "PM" stop flashing,while clock starts working.
After time setting is confirmed,press SET,
2
button is kept pressed,time will
will increase
Loading of the battery
Remove the battery cover;
1
2
3
Load the battery,then put on the cover again.
4
Note:
The distance between the signal transmission head and the rece­iver hole should be within 7m without any obstacle as well.
When electronic-started type fluorescent lamp or change-over type fluorescent lamp or room, the recei so the distance to the indoor unit should be sho
Full display or unclear display during operation indicates the
ries have been used up.
batte
If the remote controller can't run normally during operation, please
remove the batteries and
Hint:
Remove the batteries in case unit won't be in usage for a long period.
If there are any display
ver is apt to be disturbed in receiving
Load the batteries as illustrated.
2
2 R-03 batteries, resetting key
1
(cylinder);
Be sure that the loading
3
is in line with th
wireless telephone is installed in the
Please change batteries.
reload several minutes later.
after taking-out, just need to press reset key.
e" + "/"-";
the signals,
rter.
Operation
Base Operation
Remote controller
1. Unit start
Press ON/OFF on the remote controller, unit starts.
2.Select operation mode
Press MODE button. For each press, operation mode changes as follows:
Remote controller:
AUTO COOL DRY FAN HEAT
3.Select temp.setting
/
nothing
TEMP-
o
C,if kept depressed, it will increase
o
C,if kept depressed, it will decrease
LOW
MED
Remote
Controller
HI
Under the mode of auto operation, air conditioner will automatically select Cool or Heat operation
according to room temperature. When FAN is set to AUTO, the air conditioner the fan speed according to room
In DRY mode, when room temperature becomes lower than temp.setting+2oC, unit will run intermittently at LOW speed regardless of FAN
setting.
In FAN operation mode , the unit will not operate in COOL or
HEAT mode AUTO is not available in setting is disabled. In FAN mode, sleep operation is not available.
Note
AUTO
automatically adjusts
temperature.
but only in
FAN mode ,
FAN mode.
Press button
TEMP+
TEMP+
Every time the button is pressed, temp.setting increase 1
rapidly
TEMP-
Every time the button is pressed, temp.setting decrease 1 rapidly
Select a desired temperature.
4.Fan speed selection
Press FAN button. For each press, fan speed changes as
follows:
Remote controller:
Air conditioner is running under displayed fan speed. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.
Operation
Mode
AUTO
COOL
DRY
HEAT
FAN
Display Board
And temp.
Emergency operation and test operation
Emergency Operation:
Use this operation only when the remote controller is defective or lost.
When the emergency ope pressed,the" Pi "sound is heard once means
the start of this operation.
In this ope
the according to the room temperature.
temperature
ABOVE 23
BELOW 23
(C
Room temperature
It is not possible to operate in dry mode.
ration, the system automatically selects
operation modes
Room
ooling only uint
BELOW 23
O
C
O
C
Operation mode
COOLING
HEAT
O
C
ration switch is
,cooling or fan or heat,
.
Designated temperature
26OC
23
Operation
mode
FAN
O
C
Designated temperature
, which
Timer
mode
NO
NO
O
26
C
Air flow
AUTOMATIC
AUTOMATIC
Timer mode
NO
Test operation:
Test ope ration switch is the same as emergency switch.
Use this switch in the test operation when the room
temperature is below 16 normal operation.
Continue to press the test operation
switch for more than 5 seconds . After
you hear the "Pi" sound twice,
your finger from the switch: the cooling
operation starts with the air flow speed "Hi".
o
C, do not use it in the
release
Pi
Air flow
AUTOMATIC
Pi Pi
Air Flow Direction Adjustment
1.Status display of air flow
Vertical flap
Pos.1
Pos.4
2.Left and right air flow adjustment
Move the vertical blade by a knob on air
to adjust left and right direction referring to Fig.
Cautions:
When adjusting the flap by hand,turn off the unit. When humidity is high,condensate water might occur
at air outlet if all vertical louvers are right.
It is advisable not to keep horizontal flap at downward position for a long time in COOLor DRY
otherwise, condensate water might occur.
Note: When restart after remote turning off, the remote
controller will automatically
set swing position.
Pos.2
Pos.5
Pos.3
Pos.6
(Auto swing)
(manual)
conditioner
adjusted to left or
mode ,
memorize the previous
3
Operation
Sleep Operation
Before going to bed,you can simply press the SLEEP button and unit will operate in SLEEP mode and bring you a sound sleep.
Use of SLEEP function
After the unit starts,set the operation status, then press SLEEP button before which the clock must be adjusted and time being set.
Operation Mode
1. In COOL,DRY mode
1 hours after SLEEP mode starts,temp.will become
O
1 higher than temp.setting.After another 1 hours,
C
temp.rises by 1 futher.The unit will run for further 6 hours then stops Temp. is higher than temp. setting so that room temperature won’t be too low for your sleep.
SLEEP operation starts SLEEP operation stops
Temp.setting
In HEAT mode
2.
1 hours after SLEEP mode starts,temp will become 2 lower than temp.setting.After another 1 hours,temp decrease by 2 futher.After more another 3hours,temp.rises
O
C
by 1 futher.The unit will run for further 3 hours then stops.Temp.is lower than temp. setting so that room temperature won’t be too high for your sleep.
O
C
Approx.6hrs
Rises 1
Rises 1OC
O
C
1 hr
1 hr
In COOL, DRY mode
O
C
Unit stop
O
C
In AUTO mode
3.
The unit operaters in corresponding sleep mode adapted to the automatically selected operation mode.
4. In FAN mode
It has no SLEEP function.
5.Set the wind speed change when sleeping
If the wind speed is high or middle before setting for the sleep, set for lowing the wind speed after sleeping. If it is low wind, no change.
Note
When TIMER function is set, the sleeping function can't be set up .After the sleeping function is set up
,
if user resets TIMER function, the sleeping function will be cancelled;the machine will be in the state of timing-on.
POWER/SOFT Operation
(1)
POWER Operation
When you need rapid heating or cooling, you can use this function.
high speed of AUTO fan mode. In HEAT mode, fan speed automatically takes medial speed of AUTO fan mode.
(2)
You can use this function when silence is needed for rest or reading. In SOFT operation mode, fan speed
In COOL mode, fan speed automatically takes
SOFT Operation
automatically takes low speed of AUTO fan mode.
Note
During POWER operation, in rapid HEAT or COOL mode ,the room will show inhomogeneous temperature distribution. Long period SOFT operation will cause effect of not too cool or not too warm.
To cancel POWER or SOFT operation
Press POWER/SOFT button again ,POWER or SOFT
disappear
The following functions and related displays are not available
HSU-09HRA103/R2
s.
HSU-12HRA103/R2
HEALTHY Operation
Temp.setting
1 hr
1 hr
SLEEP operation starts
Decreases 2OC
Decreases 2
3 hrs
In HEAT mode
Unit stop
O
C
3 hrs
Rises 1OC
SLEEP operation stops
Healthy Negative ions
The anion generator in the airconditioner can generate a lot of anion effectively balance the quantity of position and anion in the air and also to kill bacteria and speed up the dust sediment in the room and finally clean the air in the room.
4
Operation
EUROPEAN REGULATIONS CONFORMITY FOR THE MODELS
Timer On/Off On-Off Operation
Set clock correctly before starting TIMER operation.
1.After unit starts, select your desired operation mode.
2.Press TIMER button to change TIMER mode. Every time the button is pressed, display changes as follows: Remote controller:
BLANK
TIMER ON TIMER OFF TIMER ON-OFF
Then select your desired TIMER mode (TIMER ON or TIMER OFF or TIMER ON-OFF). " "or " "will flash.
3.Press TIME+ /TIME- button to set time. It can be adjusted within 24 hours.
4.After setting correct time, press SET button to confirm " "or" " on the remote controller stops flashing.
5.Cancel TIMER mode Just press TIMER button several times until TIMER mode disappears. Hints: After replacing batteries or a power failure happens, time setting should be reset. Remote controller possesses memory function,when use TIMER mode next time, just press SET button after mode selecting if time setting is the same as previous one. According to the Time setting sequence of TIMER ON or TIMER OFF, either Start-Stop or Stop-Start can be achieved.
Healthy airflow Operation
1.Press ON/OFF to starting
Setting the comfort work conditions.
2.The setting of healthy airflow function
1).Press the button of healthy airflow
display. Horizontal airflow sending.
blows direct to the body.
2).Press the button of healthy airflow again, appears on the displa
. Downward airflow sending.
y
blows direct to the body.
3.The cancel of the healthy airflow function Press the button of healthy airflow again, working under the condition before the setting of healthy
airflow function. Notice: Do not direct the flap by hand. Otherwise, the
grille will run incorrectly. If the grille is not run correctly, stop
for a minute and then start, adjusting by remote controller.
Note:
1.After setting the healthy airflow function, the position
grill is fixed.
2.In heating, it is better to select the
3.In cooling, it is better to select the
4.In cooling and dry, using the air conditioner for a long
time under the high air humidity, condensate water may occur at the grille .
, appears on the
Avoid the airflow
Avoid the airflow
the unit
goes on
mode. mode.
CE
All the products are in conformity with the following European provision:
- Low Voltage Directive 73/23/EEC
- Low Voltage Directive 2006/95/EC
-Electomagnetic CompatibilitY 89/336/EEC
-Electomagnetic CompatibilitY 2004/108/EC
ROHS
The products are fulfilled with the requirements in the directive 2002/95/EEC of the European parliament and of
council on the Restriction of the use of Certain Hazardous Substances in Electrical and Electronic Equipment (EU RoHS Directive)
WEEE
In accordance with the directive 2002/96/CE of the European parliament, herewith we inform the consumer about the dis-
posal requirements of the electrical and electronic products.
DISPOSAL REQUIREMENTS:
Your air conditioning product is marked with this symbol.This means that electrical and electronic
products shall not be mixed with unsorted household waste. Do not try to dismantle the
system yourself : the dismantling of the air conditioning system,treatment of the refrigerant, of oil and of other part must be done by a qualified installer in accordance with relevant local and national legislation. Air conditioners must be treated at a specialized treatment facility for reuse, recycling and recovery. By ensuring this product is disposed of correctly, you will help to prevent potential negative cons­equences for the environment and humen health. Please contact the installer or local authority for more information. Battery must be removed from the remote controller and dis­posed of separately in accordance with relevant local and nationl legislation.
IMPORTANT INFORMATION REGA­RDING THE REFRIGERANT USED
Contains fluorinated greenhouse gases covered by the Kyoto Protocol
R410A
2
F E
This product contains fluorinated greenhouse gases covered by the Kyoto Protocol. Do not vent into the atmosphere.
Refrigerant type:R410A GWP* value:1975 GWP=global warming potential Please fill in with indelible ink,
• 1 the factory refrigerant charge of the product
• 2 the additional refrigerant amount charged in the field and
• 1+2 the total refrigerant charge on the refrigerant charge label supplied with the product. The filled out label must be adhered in the proximity of the product charging port (e.g. onto the inside of the stop value cover). A contains fluorinated greenhouse gases covered by the Kyoto Protocol B factory refrigerant charge of the product: see unit name plate C additional refrigerant amount charged in the field D total refrigerant charge E outdoor unit F refrigerant cylinder and manifold for charging
1=
2=
1
1+2=
kg
kg
kg
A
B
C
D
5
Maintenance
For Smart Use of The Air Conditioner
Setting of proper room temperature
Proper
temperature
Close doors and windows during operation
During cooling operation prevent the penetration of
direct sunlight with
curtain or blind
If the unit is not to be used for a long time, turn off the power supply main switch.
OFF
Do not block the air inlet or outlet
Use the timer effectively
Use the louvers effectively
Remote Controller
Do not usewater,wipe the controller with a dry cloth.Do not use glass
cleaner or chemical cloth.
Indoor Body
wipe the air conditioner by using a soft and dry cloth.For serious stains,
use a neutral detergent diluted with water.Wring the water out of the cloth before wiping,then wipe off the detergent completely.
Do not use the following for cleaning
Gasoline,benzine, thinner or cleanser
damage the coating of the unit.
ay
m
Hot water over 40OC(104OF) may cause
discoloring or deformation.
Air Filter cleaning
Open the inlet grille by pulling it upward.
Remove the filter.
Push up the filter's center tab slightly until it is
released
Clean the filter.
Use a vacuum cleaner to remove dust, or wash the filter with water.After washing, dry the filter completely in the shade.
Attach the filter.
Attach the filter correctly so that the "FRONT" indication
is
completely
and left filters are not
may cause defects.
Close the inlet grille.
from the stopper, and remove the filter do
facing to the front.Make sure that the filter is
fixed behind the stopper.If the right
attached correctly, that
wnw
ard.
Once every two weeks
Replacement of Air Purifying Filter
1.Open the lnlet Grille
Prop up the inlet grille by using a
small device named grille-support
which located in the right side of the indoor unit.
2.Detach the standard air filter
Slide the knob slightly up release the filter, then withdraw it.
3.Attach Air Purifying Filter
Put air purifying filter appliances into the
right and left filter frames.
ward to
Detach old Air Purifying Filter
4.Attach the standard air filter
(Necessar
y installation)
ATTENTION:
The white side of the photocatalyst air purifying filter face outside,and the black side face the unit The green
side of the bacteria-killing medium air purifying filter face outside,and the white side face the unit.
5.Close the Inlet Grille
Close the Grille surely
NOTE:
The photocatalyst air purifying filter will be solarized in fixed time. In normal family,
The bacteria-killing medium air purifying filter will be used for a long time,no need for replacement. But in the period of using them ,you should remove the dust frequently by
using vacuum cleaner or flaping them lightly,otherwise ,
its performance will be affected.
Please keep the bacteria-killing medium air purifying filter in the cool and dry conditions when you stop using it,or its ability of sterilization will reduced.
it will be solarized every 6 months.
avoid long time directly sunshine
be
6
Cautions
WARNING
Please call Sales/Service Shop for the Installation.
Do not attempt to install the air conditioner by yourself because improper works may cause electric shock, fire, water leakage.
WARNING
When abnormality such as burnt-small found, immediately stop the operation button and contact sales shop.
Use an exclusive power source with a circuit breaker
Check proper installation of the drainage securely
OFF
Connect power supply cord to the outlet completely
STRICT
ENFORCEMENT
Do not use power supply cord in a bundle.
STRICT
ENFORCEMENT
Use the proper voltage
Take care not to damage
the power supply cord.
PROHIBITION
Do not start or stop the operation by disconnecting the power supply cord and so on.
PROHIBITION
Do not use for the purpose of storage of food, art work, precise equipment, breeding, or cultivation.
Do not channel the air flow directly at people, especially at infants or the aged.
1.Do not use power supply cord extended or connected in halfway
2.
Do not install in the place where there is any
possibility of inflammable gas leakage around the unit.
STRICT
ENFORCEMENT
PROHIBITION
PROHIBITION
3.Do not get the unit exposed
to vapor or oil steam.
Do not insert objects into the air inlet or outlet.
Do not try to repair or reconstruct by yourself.
CAUTION
Take fresh air occasionally especially when gas appliance is running at the same time.
STRICT ENFORCEMENT
PROHIBITION
PROHIBITION
Connect the earth cable.
earthing
Do not operate the switch with wet hand.
PROHIBITION
Do not install the unit near a fireplace or other heating apparatus.
PROHIBITION
Do not place animals or plants in the direct path of the air flow
PROHIBITION
STRICT
ENFORCEMENT
Check good condition of the installation stand
PROHIBITION
Do not place any objects on or climb on the unit.
PROHIBITION
PROHIBITION
Do not pour water onto the unit for cleaning
PROHIBITION
Do not place flower vase or water containers on the top of the unit.
PROHIBITION
7
Trouble shooting
Cautions
Before asking for service, check the following first.
Cause or check points
When unit is stopped, it won't restart
immediately until 3 minutes have
elapsed to protect the system. When the electric plug is pulled out
and reinserted, the protection circuit will work for 3 minutes to protect the
air conditioner.
During unit operation or at stop, a swishing or gurgling noise may be heard.At first 2-3 minutes after
unit start, this noise is more noticeable. (This noise is generated by refrigerant flowing in the system.)
During unit operation, a cracking noise may be heard.This noise is
generated by the casing expanding or shrinking because of temperature changes. Should there be a big noise from
air flow in unit operation, air
filter may be too dirty.
This is because the system circulates smells from the interior air such as the smell of furniture, paint, cigarettes.
During COOL or DRY operation,
indoor unit may blow out mist. This is due to the sudden cooling of indoor air.
In DRY mode, when room temperature becomes lower than temp. setting+2
intermittently at LOW speed
regardless of FAN setting.
Is power plug inserted? Is there a power failure? Is fuse blownout?
Is the air filter dirty?
Normally it should be cleaned
every 15 days. Are there any obstacles before inlet and outlet? Is temperature set correctly? Are there some doors or
windows left open? Is there any direct sunlight through the window during the
cooling operation?(Use curtain)
Are there too much heat sources or too many people in the room during cooling operation?
o
C,unit will run
Normal Performance inspection
Multiple
check
Phenomenon
The system does not restart immediately.
Noise is heard
Smells are generated.
Mist or steam are blown out.
In dry mode, speed can’t be changed.
Poor cooling
fan
Do not obstruct or cover the ventilation
conditoner.Do not put fingers
inlet/outlet and
Do not allow children to play with the air
case should children be
swing louver.
or any other things into the
allowed to sit on the outdoor unit.
grille of the air
conditioner
Specifications
The refrigerating circuit is leak-proo f.
The machine is adaptive in following
1.Applicable ambient temperature range:
Indoor
Cooling
Outdoor
Indoor
Heating
Outdoor
Outdoor
(INVERTER)
2. If the power supply cord is damaged, it manufacturer
3. If the fuse of indoor unit on PC board is
it with the type of
broken,change it with the type of
4. The wiring method should be in line with
5. After installation, the power plug should
6. The waste battery should be disposed
7. The appliance is not intended for use
persons
8. Young children should be supervised
the appliance.
with
9. Please employ the proper power plug, cord.
10. A breaker should be incorporated into
should be
contacts should be not less than
11 .The power plug and connecting cable
attestation.
12.In order to protect the units,please turn
30 seconds
13.Please don't insert any sensor on 3-way
or its service agent or a similar
without supervision.
all-pole switch and the distance
later, cutting off the power.
Maximum:D.B/W.B Minimum:D.B/W.B
Maximum:D.B/W.B Minimum:
Maximum:D.B Minimum:
Maximum:D.B/W.B Minimum:D.B/W.B
Maximum:D.B/W.B Minimum:D.B
T. 3.15A/ 250V
D.B
D.B
must be replaced
broken,please
. If the fuse of
T.25A/250V
the local wiring
be easily reached.
properly.
by young children or
to ensure that th
which fit into the
fixed wiring. The
3mm.
between
must have
off the A/C first,
stop valve pipe
situation
32oC/23oC
o
21
C/15oC
o
43
C/26oC
o
18
C
o
C
27 0oC
o
C/18oC
24
o
-
C/-8oC
7
o
C/18oC
24
o
C
-15
qualified
outdoor
its two
acquired the local
.In no
by the
person.
change
unit is
standard.
infirm
ey
do not play
p
ower supply
breaker
and at least
fitting.
HSU-09HRA103/R2
HSU-12HRA103/R2
X
0.415
0.317
Loading...