Haier HRF-221FR, HRF-251FR, HRF-351FR, HRF-251FR/A, HRF-281FR/A Operation Manual

...
Operation Manual
HRF-221FR/A HRF-251FR/A
HRF-281FR/A HRF-351FR/A
Household Frost Free Refrigerator
Table of Contents
Before using the appliance
Diagram of parts-----------------------------------------1
Safety precautions-----------------------------------2~4
Preparation -----------------------------------------------6
Operation--------------------------------------------------7
Instructions for refrigerator storage
Refrigerating storage compartment-----------------8
Refrigerating storage precautions-------------------9
Suggestions---------------------------------------------10
Instructions for freezing storage
Freezing storage compartment----------------------11
Freezing storage precautions-----------------------12
Defrosting, cleaning and vacation
Defrosting------------------------------------------------13
Cleaning -------------------------------------------------13
Vacation---------------------------------------------14~15
Troubleshooting,after-sales service , Technical data and circuit
Troubleshooting-----------------------------------16~18
After-sales service and packing list----------19~20
Technical data and circuit---------------------------21
* Please read this operation manual carefully before
using the appliance.
* Keep this manual in a safe place.
* Appearance, color, layout of the door and position
of the lock(if the refrigerator has a lock)may vary.
Made in China
Technical Data and Circuit
HRF-221FR/A HRF-251FR/A HRF-281FR/A HRF-351FR/A
Climate Class ST ST ST ST
Protecion Class I I I I
Storage Volume(l) 197 217 237 257
Freezer Storage Volume(l) 56 66 56 66
Gross Volume(l) 221 251 281 351
Total Shelf Area(m
2
) 0.8 0.9 1 1.1
Voltage (V~/Hz) 165-220/50 165-220/50 165-220/50 165-220/50
Input Current(A) 1.7 1.7 1.7 1.7
Deforst Input power(W) 160 160 160 160
Deforst Input Current(A) 0.8 0.8 0.8 0.8
Lamp Watt(W) 15 15 15 15
Refrigerant(g) R134a,110 R134a,115 R134a,115 R134a,120
Energy Consumption(kw.h/24h)
1.2 1.3 1.3 1.4
Running Rate (%) 75 75 75 75
Dimension (DXWXH)(mm) 665X555X1400 640X605X1400 665X555X1600 640X605X1600
Net Weight(Kg) 53 58 57 63
Gross Weight(Kg) 57 62 61 67
A.PLUG
B.SWITCH1
C.LAMP
D.SWITCH2
E.FAN
F.THERMOSTAT
G.DEFROST TIMER
H.THERMOSTAT
I.HEATER 1
J.HEATER 2
K.FUSE
L.OVERLOAD PROTECTOR
M.COMPRESSOR
N.PTC
Model
21
1
Diagram of parts
Refrigerator
compartment
Freezer
compartment
Ice maker
Freezer shelf
Drawer chiller
Refrigerator food
shelves
Crisper
Bottle bin
Large bottle holder
Freezer thermostat
Light
Refrigerator
thermostat
Plug
The plug should be accessible after the appliance positioned.
If the supply cord is damaged;it must be replaced by the manufacture or its service agent or a
similary qualified person in order to avoid a hazard.
The appliance is not intended for use by young children or infirm persons without supervision.
Young children should be supervised to ensure that they do not play with the appliance.
Keep ventilation openings in the appliance enclosure or in the built-in structure;clear of
obstruction.
Do not use mechanical devices or other means to accelerate the dofrosting process, other
than those recommended by the manufacturer.
Do not damage the refrigerant circuit--(applicable only for appliances with refrigeration circuits
which are accessible to the user).
Do not use electrical appliances inside the food storage compartments, unless they are of the
type recommended by the manufacturer.
WARNING
WARNING WARNING WARNING
WARNING
WARNING
WARNING
Please determine the cause of the problem before making any repair.
Prolonged operation period of the compressor
* Initial operation.
* Large quantity of food loaded.
* Hot weather.
* Frequent opening of the refrigerator door.
* Door not properly closed.
* Improper setting of thermostat (see the section "Operation")
* Poor ventilation
Strange odor
* Failure to seal food properly
* Rotting food inside refrigerator
* Failure of regular cleaning of the
refrigerator
After-sales service and Packing List
20
Model
Operation Manual
Quality Certificate
Food shelves
Crisper
Egg holder
Drawers
Packing list
HRF-221FR/A
1
1
2
1
2
1
HRF-251FR/A
1
1
2
2
2
1
HRF-281FR/A
1
1
3
1
2
1
HRF-351FR/A
1
1
3
2
2
1
Safety precautions
2
Inflammable gas leakage in the vicinity of the
refrigerator
* Turn off any leaking valve;
* Open the doors and windows;
* Do not, under any circumstances, unplug
electrical appliances in the vicinity of the leak.
Care for external cable
* Hold the plug, not the electric cable, when
unplugging the refrigerator.
* Ensure that the electric cable is not trapped by
the refrigerator. Do not step on the cable.
* Avoid damage to the electric cable when moving
the refrigerator.
Damaged electric cable
When the electrical cable is damaged or worn, turn
off the refrigerator and consult to an authorized
service agent for replacement.
Unplug the refrigerator for the following:
* Cleaning or maintenance;
* Replacement of lamp
A separate earthed socket is required.
The refrigerator is supplied with a standard three-
pin plug, of which the one for grounding should
never be removed. Plug of installed refrigerator
shall be always accessible.
165-220V
50Hz
This refrigerator requires a 165-220V/50Hz supply
Failure in operation and damage to the control
panel, thermostat or the compressor will occur if
voltage is outside the range 165-242V unless a
regulator with a capacity of over 750W or higher is
installed.
In the event that the refrigerator does not work properly, please check out and solve problems according to
the following methods. If problems persist, contact the after-sales service center. Information of model,
accessory list and serial number of the refrigerator is required. (See the type plate of the refrigerator.)
Please determine the cause of the problem before making any repair.
The refrigerator does not operate.
Set temperature is not reached.
Contact between the
refrigerator and a wall or
other article.
Excessive noiseLamp does not illuminate.
Power supply is
not connected.
Disconnection to the power
supply (plug, socket or fuse).
Voltage is low;
The bulb is bad; Uneven placement.
Door is not properly
closed, or the door is
opened for long period;
The area is poorly ventilated, or
the two sides of the refrigerator
are covered by too much dust.
Refrigerator is in direct
sunlight, or close to a heat
source;
After-sales service
Automatic defrosting is activated. (Compressor
ceases operation for 30 minutes)
19
Loading...
+ 8 hidden pages