Haier AD182AMERA, AD28NAMBEA, AD36NAMBEA, AD422AMEAA, AD422AMERA Operation And Instruction Manual

...
Page 1
Operation & Instruction Manual
No. 0010577971
A
DUCT TYPE AIR CONDITIONER
AD182AMEAA AD242AMEAA AD282AMEAA AD362AMEAA AD422AMEAA AD482AMEAA AD522AMEAA
AD182AMERA AD242AMERA AD282AMERA AD362AMERA AD422AMERA AD522AMERA
Page 2
1
Table of Contents
Malfunction
7-8
Care and Maintenance
9
For Preparation of Heating("Hot Keep")
10
Is The Unit Installed Correctly
11
Installation Manual For Indoor Unit
12-18
Safety Precautions
3-5
Parts and Functions
6
Cautions
2
Trouble Shooting
19
Page 3
Cautions
2
All electrical repairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditoiner.
Do not damage any parts of the air conditioner that carry refrigerant by piercing or perforating the air conditioner's tubes with sharp or pointed items, crushing or twisting any tubes, or scraping the coatings off the surfaces. If the refrigerant spurts out and gets into eyes, it may result in serious eye injuries.
Do not obstruct or cover the ventilation grille of the air conditioner. Do not put fingers or any other things into the inlet/outlet and swing louver.
Do not allow children to play with the air conditioner. In no case should children be allowed to sit on the outdoor unit.
Disposal of the old air conditioner
Before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment.
It must be noticed that air conditioner system contains refrigerants, which require specialized waste disposal. The valuable materials contained in a air conditioner can be recycled. Contact your local waste disposal center for proper disposal of an old air conditioner and contact your local authority or your dealer if you have any question. Please ensure that the pipework of your air conditioner does not get damaged prior to being picked up by the relevant waste disposal center, and contribute to environmental awareness by insisting on an appropriate, anti-pollution method of disposal.
Disposal of the packaging of your new air conditioner
All the packaging materials employed in the package of your new air conditioner may be disposed without any danger to the environment.
The cardboard box may be broken or cut into smaller pieces and given to a waste paper disposal service. The wrapping bag made of polyethylene and the polyethylene foam pads contain no fluorochloric hydrocarbon.
Consult your local authorities for the name and address of the waste materials collecting centers and waste paper disposal services nearest to your house.
Safety Instructions and Warnings
important observations relating to the assembly, operation and maintenance of the air conditioner.
Installation shall be done by professional people, don't install unit by yourself.
All these valuable materials may be taken to a waste collecting center and used again after adequate recycling.
Damaged air conditioners are not to be put into operation. In case of doubt, consult your supplier.
Use of the air conditioner is to be carried out in strict compliance with the relative instructions set forth in the User's Guide.
For the purpose of safety , the air conditioner must be properly grounded in accordance with specifications.
Always remember to unplug the air conditioner before opening inlet grill. Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the outlet.
The manufacturer does not accept responsibility for any damages that may arise due to non-observation of the following instruction.
Before starting the air conditioner, read the information given in the User's Guide carefully. The User's Guide contains very
Page 4
Safety Precautions
Before starting to use the system, read carefully this"SAFETY PRECAUTIONS" to ensure a proper operation of the system. Safety precautions described here are classified to " WARNING" and " CAUTION". Precautions which are shown in the column of
" WANING" means that an improper handing could lead to a grave result like a death, serious injury, etc. However, even if precautions are shown in the column of " CAUTION", a very serious problem could occur depending on situation. Make sure to observe these safety precautions faithfully because they are very important information to ensure the safety.
Symbols which appear frequently in the text have following meanings.
Strictly prohibited.
Observe instructions faithfully.
Provide a positive grounding.
When you have read through the manual, keep it always at hand for read consultation. If the operator is replaced, make sure to hand over this manual to the new operator.
ON
OFF
WARNING
CAUTION
WARNING
CAUTION
CAUTIONS FOR INSTALLATION
The system should be applied to places as office, restaurant, residence and the like.
The system should be installed by your dealer or a professional installer.
When you need some optional devices such as a hu­midifier, electric heater, etc., be sure to use the products which are recommended by us. These devices should be attached by a professional installer.
Application to inferior environment such as an engi­neering shop, could cause equipment malfunction and serious injury or death.
Installation by yourself is not encouraged because it could cause such problems as water leakage, electrical shock or fire accident by some improper handing.
Installation by yourself is not encouraged because it could cause such problems as water leakage, electrical shock or fire accident by some improper handing.
Do not install nearby the place where may have leakage of flammable gas.
Depending on the place of installation, a circuit breaker may be necessary.
Drain pipe should be arranged to provide a positive draining.
If the gas leakes and gathers around, it may cause the fire.
Unless the circuit breaker is installed, it could cause elecrical shocks.
Where strong winds may prevail, the system should be fixed securely to prevent a collapse.
Install on the place where can endure the weight of air conditioner.
Make sure the system is grounded.
If the pipe is arranged improperly, furniture or the likes may be damaged by leaked water.
Bodily injury could result by a collapse.
Bodily injury could result by a careless installation.
Grounding cable should never be connected to a gas pipe, city water pipe, lightning conductor rod or grounding cable of telephone. If the grounding cable is not set properly, it could cause electric shocks.
CAUTIONS FOR OPERATION
You should refrain from exposing your body directly to cool wind for a long time.
Do not poke the air inlet or outlet with a bar, etc.
When any abnormal condition (scorching smell or oth­ers) is found, stop the operation immediately and turn off the power switch. Then consult your dealer.
It could affect your physical condition or cause some health problems.
Since the internal fan is operating with a high speed, it could cause an injury.
If you continue the operation without removing the cause, it could result in a trouble, electric shock or fire.
The system should never be used for any other purposes than intended such as for preservation of food, flora and fauna, pre­cision deices or work of art.
Do not handle switches with a wet hand.
Combustion apparatus should not be placed allowing a direct exposure to wind of air con­ditioner.
Incomplete combustion could occur on the apparatus.
It could cause electric shocks.
It could cause deterioration of food or other problems.
3
Page 5
4
CAUTION
Do not wash the air conditioner with water.
Do not install the system where the air outlet reaches directly the flora and fauna.
Make sure to use a fuse of proper electric rating.
Do not operate the system while the air outlet grill is removed.
It is strictly prohibited to place a container of combustible gas or liquid near the air condi­tioner or to spray it directly with the gas or liquid.
Neither stand on the air conditioner nor place something on it.
Do not use the power switch to turn on or off the system.
Do not touch the air outlet section while the swing louver is operating.
Do not use such equipment as a water heater, etc. around the indoor unit or the wire controller.
ON
OFF
It could cause electric shocks.
It will not be good for their health.
Use of steel or copper wire in place of a fuse is strictly prohibited because it could result in a trouble or fire accident.
There is a risk of injury.
It could cause a fire accident.
There are risks of falling or injury by collapsed object.
It could cause a fire or water leakage. There is a risk of injury.
If the system is operated at the vicinity of such equip­ment which generates steam, condensed water may drip during cooling operation or it could cause a fault current or short-circuit.
When operating the system simultaneously with a combustion apparatus, indoor air must be ventilated frequently.
Check occasionally the support structure of the unit for any damage after a use of long period of time.
Insufficient ventilation could cause an oxygen deficiency accident. If the structure is not repaired immediately, the unit could topple down to cause
a personal injury.
When cleaning the system, stop the operation and turn off the power switch.
Do not put water containers on the unit such as a flower vase, etc.
Cleaning should never be done while the internal fans are running with high speed.
If the structure is not repaired immediately, the unit could topple down to cause apersonal injury.
WARNING
CAUTIONS FOR TRANSFER OR REPAIR
Modification of the system is strictly prohibited. When the system needs a repair, consult your dealer.
When the air conditioner is relocated, contact your dealer or a pro­fessional installer.
Improper practice of repair could cause water leakage, electric shock or fire. Improper practice of installation could cause water leakage, electric shock or fire.
Safety Precautions
Page 6
5
2. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person.
3. If the fuse on PC board is broken please change it with the type of T 3.15A /250VAC.
4. The wiring method should be in line with the local wiring standard.
1. Applicable ambient temperature range:
The machine is adaptive in following situation
5. The power cable should be: H07RN-F 5G 4.0mm2 ( For series 522 (380-400V, 3N~, 50Hz)) ; H07RN-F 5G 2.5mm2 ( For series 482, 422, 362 282 (380-400V, 3N~, 50Hz)) ; H05RN-F 3G 6.0mm2 (For series 282 (1PH,220-230V~,50Hz)) ; H05RN-F 3G 4.0mm2 (For series 242 (1PH,220-230V~,50Hz)) ; H05RN-F 3G 2.5mm2 (For series 182 (1PH,220-230V~,50Hz)) ; The connecting cable should be H05RN-F 4G 0.75mm
2
All the cables shall have got the European authentication certificate. During installation, when the connecting cables break off, it must be assured that the grouding wire is the last one to be broken off.
6. The power cable and connect cable should be self-provided.
7. The breaker of the air conditioner should be all-pole switch; and the distance between its two contacts should be no less 3mm.
8. The indoor unit installation height is at least 2.5m.
9. A leakage breaker must be installed.
Safety Precautions
Rated Maximum Minimum 27 32 18 19 23 14 35 43 10 24 26 6 20 27 15
14.5 -- -­ 7 24 -7 6 18 --
Cooling
Heating
Indoor
outdoor
Rated Maximum Minimum 27 32 18 19 23 14 35 43 -5 24 26 -­ 20 27 15
14.5 -- -­ 7 24 -7 6 18 --
DB C WB C DB C WB C
Indoor
outdoor
DB C WB C
DB C WB C
For *.EAA :
For *.ERA :
Cooling
Heating
Indoor
outdoor
DB C WB C DB C WB C
Indoor
outdoor
DB C WB C
DB C WB C
Page 7
Parts and Functions
6
Air outlet
Air inlet
Duct
Air outlet
Air inlet
Duct
For series 182, 242, 282
For series 362, 422, 482, 522
Page 8
please check the following things about your air conditioner before making a servie call.
Unit fails to start
ON
OFF
Is the power source switch adjust cut in?
Is city supply power in normal?
Power stoppage?
Isn't the signal receiving section exposed to the direct sunlight or strong illumination?
Isn't the earth leakage breaker in action?
It is dangerous. Turn off the power supply switch immediately and contact the sales dealer.
Power supply switch is not ON.
Cooling or heating is not sufficient
Is the thermostat adjust as required?
Isn't the air filter dirty?
Isn't any doors or windows left open?
Doesn't any obstacle exist at the air inlet or outlet?
Cooling is not sufficient
Isn't sun-shine invading direct?
Isn't any unexpected heating load generated?
Isn't the room much crowded?
Isn't the swing louver horizontal? (At HEATING mode)
If swing louver is horizontal, the blow wind does not reach floor.
The wind does not blow during heating operation
Isn't it warming up?
When the air conditioner does not operate properly after you have checked the above mentioned items or when the following phenomenon is observed, stop the operation of the air conditioner and contact your sales dealer.
The fuse or breaker often shuts down. Water drops off during cooling operation. There is a irregularity in operation or abnormal sound is audible. When the CHECK LED (red) flickers of wired controller, an irregularity has occurred in the air conditioner.
Malfunction
7
Page 9
8
The followings are not malfunction
Shuru
Shuru
When the air conditioner is started, when the compressor starts or stops during operation or when the air conditioner is stopped, it sometimes sounds "shuru shuru" or "gobo gobo". It is the flowing sound of the refrigerant, and it is not a trouble.
Water flowing sound is heard.
This is caused by heat expansion or contraction of plastics.
Cracking sound is heard.
It smells.
Air which blows out from the indoor unit sometimes smells. The smell results from residents of tobacco smoke or cosmetics stuck inside of unit.
When the air conditioner is used at restaurant etc. where dense edible oil fume is always exists, white fog sometimes blows out of air outlet during operation. In this case consult sales dealer for cleaning the heat exchanger.
During operation, white fog comes out of indoor unit.
Unit does not start
Wait for three minutes
It is switched into the FAN mode during cooling.
To prevent frost from being accumulated on the indoor unit heat exchanger, it is sometimes automatically switched to the FAN mode but it will soon return to the cooling mode.
Even if the operation switch is turned on, cooling, dehumidifying or heating is not operable for three minutes after the conditioner is stopped. Because the protecting circuit is activated. (During this time air conditioner operates in fan mode.)
The air conditioner can not be restarted soon after it stops.
Air does not blow or the fan speed can not be changed during dehumidifying
During operation, operation mode has changed over automatically.
Water or steam generates from the outdoor unit during heating.
When it is excessively cooled during dehumidifying, the blower automatically repeats reducing and lowering the fan speed.
Isn't the AUTO mode selected? In the case of AUTO mode, operation mode is changed automati­cally from cooling to heating or vise-versa according to the room temperature.
This results when frost accumulated on the outdoor unit is removed (during defrosting operation).
Malfunction
Page 10
9
Care and Maintenance
Points to observe
Turn off the power supply switch. Do not touch with wet hand.
Do not use hot water or volatileliquid.
ON
OFF
Thinner
Do not use!
Benzine
Tooth powder
Cleaning
CAUTION
Do not dry the air filter with fire. Do not run the air conditioner without the air filter.
Do not open the inlet grill until fan stops completely. Fan will continue rotating for a while by the law of inertia after operation is being stopped.
CAUTION
Pre-Season Care
See that there are no obstacles blocking the air inlet and air outlet of both indoor and outdoor units. Make sure that the air filter is not dirty. Cut in the power supply switch 12 hours before starting run.
Post-Season Care
Operate the unit with FAN mode on a fair day for about half a day to dry the inside of the unit well. Stop operation and turn off the power supply switch. Electric power is consumed even the air conditioner is in stop. Clean the air filter and set it in the place.
Care and Cleaning of the unit
Clean with soft and dry cloth. If it is very dirty, dissolve neutral detergent in the lukewarm water and make the cloth wet with the water. After wiping, clean off the detergent using clean water.
Page 11
10
For Preparation of Heating("Hot Keep")
"HOT KEEP"is operated in the following cases.
When heating is started:
In order to prevent blowing out of cool wind, the indoor unit fan stopped according to the room temperature which heating operation is started. Wait for approx. 2 to 3 minute, and the operation will be automatically changed to the ordinary heating mode.
Defrosting operation (in the heating mode):
When it is liable to frost. the heating operation is stopped automatically for 5 to 12 minutes once per approx. one hour, and defrosting is operated. After defrosting is completed, operation mode is automatically changed to ordinary heating operation.
When the room thermostat is actuated:
When room temperature increases and room temperature controller actu­ates, the fan speed is automatically changed to stop under low temperature condition of indoor heat exchanger. When room temperature decreases, air conditioner automatically changes over to ordinary heating operation.
WARMING OPERATION
Heat pump type warming
Defrosting operation
Atmospheric temperature and warming capacity
Period of warm-up
With the heat pump type warming, the mechanism of heat pump that concentrate heat of outdoor air with the help of refrigerant to warm the indoor space, is utilized.
When a room is warmed with a heat pump type air conditioner, frost accumulates on the heat ex­changer of outdoor unit along with the drop of indoor temperature. Since the accumulated frost re­duces the effect of warming, it is necessery to automatically switch the operation to the defrosting mode. During the defrosting operation, heating operation is interrupted.
Warming capacity of heat pump type air conditioner decreases along with the drop of outdoor temperature. When the warming capacity is not sufficient, it is recommended to use another heating implement.
Since the heat pump type air conditioner employs a method to circulate warm winds to warm the entire space of a room, it takes time before the room tem­perature rises. It is recommendable to start the operation a little earlier in a very cold morning.
Page 12
11
Is The Unit Installed Correctly
For inspection and maintenance
When you change your address or the installation place
Electric work
Confirm the following items for safe and comfortable use of air conditioner. The installation work is to be burden on the sales dealer, and do not conduct it by yourself.
Installation place
Avoid installing the air conditioner near the place where possibility of inflammable gas leakage exists.
Install the unit at well ventilated place.
Install the air conditioner firmly on the foundation that can fully support the weight of the unit.
If not, it may cause vibration or noise.
If some obstacle exist, it may cause capacity reduction or noise increase.
Explosion (Ignition) may occur.
Select the place so as not to annoy neighbor with the hot air or noise.
Snow protection work is necessary where outdoor unit is blocked up by snow.
It is advisable not to install the air con­ditioner at the following special place. It may cause malfunction, consult the sales dealer when you have to install the unit on such a place.
The place where corrosive gas generates (Hot spring area etc.) The place where salt breeze blows (Seaside etc.) The place where dense soot smoke exists The place where humidity is extraordina­rily high The place where near the machine which radiates the electromagnetic wave The place where voltage variation is con­siderably large
For details consult your sales dealer.
The electric work must be burden on the authorized engineer with qualification for electric work and grounding work, and the work must be conducted in accordance with electric equipment technical standard.
The power source for the unit is to be of exclusive use. An earth leakage breaker should be installed.(This is necessary to prevent electric shock.) The unit must be grounded.
Special technology is required for removal or reinstallation of air conditioner, consult the sales dealer. Besides, construction expense is charged for removal or reinstallation.
The capacity of air conditioner will decrease by contamination of inside of unit when it is used for about three years although depending upon the circumstances under which it is used, and so in addition to the usual maintenance service, special inspection/maintenance service is necessary. It is recommended to make a maintenance contract (charged) by consulting your sales dealer.
Page 13
12
Installation Manual For Indoor Unit
1. Safety precautions
WARNING
Please read these "Safety Precautions" first then accurately execute the installation work. Though the precautionary points indicated herein are divided under two headings, and , those points which are related to the strong possibility of an installation done in error resulting in death or serious injury are listed in the section. However, there is also a possibility of serious consequences in relationship to the points listed in the section as well. In either case, important safety related information is indicated, so by all means, properly observe all that is mentioned. After completing the installation, along with confirming that no abnormalities were seen from the operation tests, please explain operating methods as well as maintenance methods to the user (customer) of this equipment, based on the owner's manual. Moreover, ask the customer to keep this sheet together with the owner's manual.
This system should be applied to places as office, restaurant, residence and the like. Application to inferior environment such as engineering shop could cause equipment malfunction. Please entrust installation to either the company which sold you the equipment or to a professional contractor. Defects from improper installations can be the cause of water leakage, electric shocks and fires. Execute the installation accurately, based on following the installation manual. Again, improper installations can result in water leakage, electric shocks and fires. When a large air-conditioning system is installed to a small room, it is necessary to have a prior planned countermeasure for the rare case of a refrigerant leakage, to prevent the exceeding of threshold concentration. In regards to preparing this countermeasure, consult with the company from which you perchased the equipment, and make the installation accordingly. In the rare event that a refrigerant leakage and exceeding of threshold concentration does occur, there is the danger of a resultant oxygen deficiency accident. For installation, confirm that the installation site can sufficiently support heavy weight. When strength is insufficient, injury can result from a falling of the unit. Execute the prescribed installation construction to prepare for earthquakes and the strong winds of typhoons and hurricanes, etc. Improper installations can result in accidents due to a violent falling over of the unit. For electrical work, please see that a licensed electrician executes the work while following the safety standards related to electrical equipment, and local regulations as well as the installation instructions, and that only exclusive use circuits are used. Insufficient power source circuit capacity and defective installation execution can be the cause of electric shocks and fires. Accurately connect wiring using the proper cable, and insure that the external force of the cable is not conducted to the terminal connection part, through properly securing it. Improper connection or securing can result in heat generation or fire. Take care that wiring does not rise upward, and accurately install the lid/service panel. Its improper installation can also result in heat generation or fire. When setting up or moving the location of the air conditioner, do not mix air etc. or anything other than the designated refrigerant (R407C) within the refrigeration cycle. Rupture and injury caused by abnormal high pressure can result from such mixing. Always use accessory parts and authorized parts for installation construction. Using parts not authorized by this company can result in water leakage, electric shock, fire and refrigerant leakage.
CAUTION
WARNING
WARNING
CAUTION
CAUTION
Execute proper grounding. Do not connect the ground wire to a gas pipe, water pipe, lightning rod or a telephone ground wire. Improper placement of ground wires can result in electric shock. The installation of an earth leakage breaker is necessary depending on the established location of the unit. Not installing an earth leakage breaker may result in electric shock. Do not install the unit where there is a concern about leakage of combustible gas. The rare event of leaked gas collecting around the unit could result in an outbreak of fire. For the drain pipe, follow the installation manual to insure that it allows proper drainage and thermally insulate it to prevent condensation. Inadequate plumbing can result in water leakage and water damage to interior items.
Page 14
13
NOTICE
All Wiring of this installation must comply with NATIONAL, STATE AND LOCAL REGULATIONS. These instructions do not cover all variations for every kind of installation circumstance. Should further information be desired or should particular problems occur, the matter should be referred to your local distributor.
WARNING
BE SURE TO READ THESE INSTRUCTIONS CAREFULLY BEFORE BEGINNING INSTALLATION. FAI­LURE TO FOLLOW THESE INSTRUCTIONS COULD CAUSE SERIOUS INJURY OR DEA TH, EQUIPMENT MALFUNCTION AND/OR PROPERTY DAMAGE.
(1) Preparation of indoor unit
Before or during the installation of the unit, assemble necessary optional panel etc. depending on the specific type.
(2) Select places for installation satisfying following conditions and at the same time obtain the consent on the part of your client user.
(a) Places where chilled or heated air circulates freely. When the installation height exceeds 3m warmed air stays close to the ceiling. In such cases, suggest your client users to install air circulators. (b) Places where perfect drainage can be prepared and sufficient drainage. (c) Places free from air disturbances to the suction port and blowout hole of the indoor unit, places where the fire alarm may not malfunction or short-circuit. (d) Places with the environmental dew-point temperature is lower than 28 and the relative humidity is less than 80 %. (When installing at a place under a high humidity environment, pay sufficient attention to the prevention of dewing such as thermal insulation of the unit. ) (e) Ceiling height shall have the following height.
50 or more
Obstacle
100 or more
100 or more
1000 or more
Unit: mm
Installation space
C
Installation Manual For Indoor Unit
Combination with silent panel
416mm 366mm
For series 362 422 482 522 For series 182 242 282
Page 15
14
(4) Preparation for suspending the unit
(a) Size of hole at ceiling and position of hanging bolts
<Combination with silent panel>
57
A
B
C
(Hanging bolt position)
(Ceiling hole size)
(Panel dimensions)
137
30
30
(Ceiling ~ panel wrap dimensions)
(Ceiling ~ panel
wrap dimensions)
(Hanging bolt position)
(Ceiling hole size)
(Panel dimensions)
75
545
690
750
70
(Pipe co-
nnection side)
(b) Hanger bolts installation
Use care of the piping direction when the unit is installed.
Hanging bolt M10
Hole-in anchor Hole-in plug
Insert
Concrete
Dimensions
A
Unit: mm
B C
1406 1600
1660
1000 1180
1240
Model
Installation Manual For Indoor Unit
For series 362 422 482 522
For series 182 242 282
(3) Avoid installation and use at those places listed below.
(a) Places exposed to oil splashes or steam (e.g. kitchens and machine plants). Installation and use at such places incur deteriorations in the performance or corrosion with the heat exchanger or damage in molded synthetic resin parts. (b) Places where corrosive gas (such as sulfurous acid gas) or inflammable gas (thinner, gasoline, etc) in generated or remains. Installation and use at such places cause corrosion in the heat exchanger and damage in molded synthetic resin parts. (c) Places adjacent to equipment generating electromagnetic waves or high-frequency waves such as in hospitals. Generated noise may cause malfunctioning of the controller.
Page 16
15
(5) Installation of indoor unit
Fix the indoor unit to the hanger bolts. If required, it is possible to suspend the unit to the beam, etc. Directly by use of the bolts without using the hanger bolts.
When the dimensions of main unit and ceiling holes does not match, it can be adjusted with the slot holes of hanging bracket.
Note
Adjusting to the levelness
(a) Adjust the out-of levelness using a level or by the following method.
Make adjustment so that the relation between the lower surface of the unit proper and water level in the hose becomes as given below.
(b) Unless the adjustment to the levelness is made properly, malfunctioning or failure of the float switch may occur.
Tap selection on blower unit
(When the high performance filter is used.)
Taps of blower unit are set at the standard selection at the shipping from factory. Where the static pressure is raised by employing such option as the high performance filter, etc., change the connection of connectors provided at the flank of control box as shown below.
(6) Drain Piping
(a) Drain piping should always be in a downhill grade (1/50~1/100) and avoid riding across an elevation or making traps.
When connecting the drain pipe to unit, pay suffcient attention not to apply excess force to the piping on the unit side. Also, fix the piping at a point as close as possible to the unit.
For drain pipe, use hard PVC general purpose pipe VP-25(I.D.1") which can be purchased locally. When connecting, insert a PVC pipe end securely into the drain socket before tightening securely using the attached drain hose and clamp. Adhesive must not be used connection of the drain socket and drain hose (accessory).
Drain hose
Stage difference part
Drain socket
Drain socket
Main unit
VP 25 joint (field purchased)
Pipe cover(large) [for insulation] (accessory)
VP 25 (field purchased)
Pipe cover [for insulation] (field purchased)
Drain hose (accessory)
Pipe cover(small) [for insulation] (accessory)
Clamp (accessory)
Adhesion
PVC hose
Piping side
Supply water
Water level
0~5 mm
(0~0.2")
Bring the piping side slightly lower.
Hanging bolt
M10 nut
Main unit
M10 washer
M10 spring washer
Do not pipe under water
Keep free from traps
Avoid riding across an elevation
Air vent
Inproper pipingGood piping
1.5m ~ 2m
Suspension bolts
Heat insulation
A downhill grade of 1/100 or more
(b)
(c)
Red
Yellow
White
Standard tap (at shipping) High speed tap
Black
White
Connector white
Connector white
Control box side
Moter side
Moter side
Red
Blue
Red
Yellow
White Blue
Red
Yellow
White Blue
White Blue Red
Installation Manual For Indoor Unit
Page 17
16
VP 30
Secure the elevation as high as possible (approx. 100 mm)
A downhill grade of 1/100 or more
Drain hose
Joint for VP 25 (Local procurement)
600
(Maximum local drain up dimension)
Right overhead
290~325mm
Attached drain hose clamp
Drain piping
Main unit
Drain situation can be checked with transparent socket
Remove grommet. Make sure to install it back after test.
Insert water supply hose for 20 mm ~ 30 mm to supply water. (Insert hose facing toward bottom.)
Pour water into a convex joint.
When constructing drain piping for several units, position the common pipe about 100 mm below the drain outlet of each unit as shown in the sketch. Use VP-30(11/4") or thicker pipe for this purpose. Be sure to provide heat insulation to hard PVC pipes of indoor placement. Do not ever provide an air vent. The height of the drain head can be elevated up to a point 500 mm above the ceiling, and when an obstacle exists in the ceiling space, elevate the piping to avoid the obstacle using an elbow or corresponding gadget. When doing this, if the stretch for the needed height is higher than 500 mm, the back­flow quantity of drain at the event of interruption of the operation gets too much and it may cause overflow at the drain pan. Therefore, make the height of the drain pipe within the distance given in the sketch below. Avoid positioning the drain piping outlet at a place where generation of odor may be stimulated. Do not lead the drain piping direct into a sewer from where sulfur gas may generate.
Drainage Test
Conduct a drainage test after completion of the electrical work. During the trial, make sure that drain flows properly through the piping and that no water leaks from connections. In case of a new building, conduct the test before it is furnished with the ceiling. Be sure to conduct this test even when the unit is installed in the heating season.
Procedures
Supply about 1000 cc of water to the unit through the air outlet using a feed water pump. Check the drain while cooling operation.
(d)
(e)
(f)
(h)
(g)
1 2
3 4
1 2
(In the electrical work has not been completed, connect a convex joint in the drain pipe connection to provide a water inlet. Then, check if water leaks from the piping system and that drain flows through the drain pipe normally.)
Installation Manual For Indoor Unit
Page 18
17
(7) Installation work for air outlet ducts
Calculate the draft and external static pressure and select the length, shape and blowout.
A Blowout duct
2-spot, 3-spot and 4-spot with 200 type duct are the standard specifications. Determine the number of spots based on following table.
Note (1) Shield the central blowout hole for 2-spot. (2) Shield the blowout hole around the center for 3-spot.
Limit the difference in length between spots at less than 2:1. Reduce the length of duct as much as possible. Reduce the number of bends as much as possible. (Corner R should be as larger as possible.)
Use a band. etc. to connect the main unit and the blowout duct flange. Conduct the duct installation work before finishing the ceiling.
(8) Connection of suction, exhaust ducts
(a) Duct connection position
i) Fresh air inlet
Inlet can be selected from the side or rear faces depending on the working conditions. Use the rear fresh air inlet when the simultaneous intake and exhaust is conducted. (Side inlet cannot be used.)
ii) Exhaust (Make sure to use also the suction.)
Use the side exhaust port.
Good exampleBad exampleBad example
Ceiling surface
Heat
insulation
Suction panel (Silent panel)
Air conditioner main unit
B Special blowout (Option)
A Blowout duct (Optional or marketed item)
C
Hole for check
special inlet (option) (with air filter)
inlet duct
(optional or
marketat item)
Exhaust hole
State seeing from top of unit
Side fresh air inlet
Rear fresh air inlet
Fig.1
Fig.2
Installation Manual For Indoor Unit
Page 19
18
5. Electric wiring
WARNING
DANGER OF BODILY INJURY OR DEATH
TURN OFF ELECTRIC POWER AT CIRCUIT BREAKER OR POWER SOURCE BEFORE MAKING ANY ELECTRIC CONNECTIONS. GROUND CONNECTIONS MUST BE COMPLETED BEFORE MAKING LINE VOLTAGE CONNECTIONS.
(1) Selection of size of power supply and interconnecting wires.
Precautions for Electric wiring
Electric wiring work should be conducted only by authorized personnel. Do not connect more than three wires to the terminal block. Always use round type crimped terminal lugs with insulated grip on the ends of the wires. Use copper conductor only.
Select wire sizes and circuit protection from table below. (This table shows 20 m length wires with less than 2% voltage drop.)
(2) Wiring connection
Make wiring to supply power to the indoor unit, so that the power for the outdoor unit is supplied by terminals.
Item
Model
Phase
Switch breaker
(A)
Circuit breaker
Overcurrent protector
rated capacity (A)
Power source
wire size
(minimum)
(mm2)
30 20 2.5
Switch
breaker(A)
Earth leakage breaker
Leak
current(mA)
30
Installation Manual For Indoor Unit
30
1
40 26 2.5 40
For series 242 282
3
L N
1 2 3
Y/G
INDOOR UNIT TERMINAL BLOCK
POWER
1PH, 220-230V~, 50Hz
SUPPLY:
Y/G
1 2 3
OUTDOOR UNIT
TERMINAL BLOCK
For series 182
1
40 26 6.0 40
For series 282 For series
282 362 422 482
30 20 4.0 30
3
For series522
30
30 30
30
1
40 26 4.0 40
For series 242
1 2 3 N L
1 2 3
POWER
1PH, 220-230V~, 50Hz
SUPPLY:
For series 182
For series 282 362 422 482 522
OUTDOOR UNIT TERMINAL BLOCK
INDOOR UNIT TERMINAL BLOCK
POWER SUPPLY:
380-400V, 3N~, 50Hz
R S T
N 1 2 3
1 2 3
Y/G
Y/G
Make wiring to supply power to the outdoor unit, so that the power for the indoor unit is supplied by terminals.
INDOOR UNIT TERMINAL BLOCK
OUTDOOR UNIT TERMINAL BLOCK
Page 20
19
For remote
type, flash
times12
3
4
5
6
7
8
9
10111213141516
171819
20
Failure description
Indoor ambient temp. sensor failure
Indoor coil temp. sensor failure
Outdoor ambient temp. sensor failure
Outdoor coil temp. sensor failure
Over-current protection
High pressure abnormal
Power supply abnormal
Communication between wired
controller and indoor abnormal
Communication between indoor and outdoor abnormal
Drainage system abnormal
Outside alarm signal input
Gas pipe temp. sensor abnormal
Temperature protection malfunction
Discharging temp. sensor abnormal
EEPROM abnormal
Pressure abnormal(low pressure)
Compressor overheat
Abnormal mode
Outdoor coil B(suction temp sensor-for MRV II)
Outdoor discharging B(oil temp sensor-for MRV II)
Reason
Sensor broken down or short circuit for more than 2m continuously
Sensor broken down or short circuit for more than 2m continuously
Sensor broken down or short circuit for more than 2m continuously
Sensor broken down or short circuit for more than 2m continuously
CT check abnormal 3 times in 30m
High pressure switch acts 3 times in 30m
Fault phase, short of phase, out of balance greatly
Communication abnormal for more than 4m continuously
Communication abnormal for more than 4m continuously
Float switch broken down for more than 25m continuously
Outside signal broken down for more than 10s
Sensor broken down or short circuit for more than 2m continuously
Solenoid valve act incorrectly 3 times continuously
Sensor broken down or short circuit for more than 2m continuously
EEPROM data missing
Low pressure switch acts in normal running
The discharging temperature is higher than 120degree
Indoor operation mode is different with the running indoor unit.
Sensor broken down or short circuit for more than 2m continuously
Sensor broken down or short circuit for more than 2m continuously
Remarks
shows resumable fault, * shows it is not resumable fault.
Resumable if
lower than 100
degree
Trouble Shooting
Page 21
HAIER GROUP Qingdao Haier Air Conditioner Electric Co., Ltd. Address: Haier Garden ,Qianwangang Road , Economic Development Zone, Qingdao ,Shandong 266500, P.R.China Web Site: http://www.haier.com
Loading...