Haier AC092ACBHA, AC122ACBHA, AU092AABHA, AU122AABHA, HCFU-09HA03/R1 Operation And Installation Manual

...
OPERATION & INSTALLATION MANUAL
AC092ACBHA AU092AABHA (HCFU-09HA03/R1(B)) AC122ACBHA AU122AABHA (HCFU-12HA03/R1(B))
No. 0010572437 A
Please read this operation manual before using the air conditioner. Please keep this manual carefully and safely.
Contents
Cautions
................................................................................
Safety Precautions
...................................................................
Features and Functions
............................................................
Name of Parts
..........................................................................
Installation
...............................................................................
Cleaning and Care
..................................................................
Trouble Shooting
..................................................................
Operation Tips
........................................................................
Installation Tools ....................................................................
Installation Procedures .....................................................
1-2
3 4 5 6 7
8-9
10 11
12-23
Cautions
1
For the purpose of safety, the air conditioner must be properly grounded in accordance with specifications.
Always remember to unplug the air conditioner before opening inlet grill. Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the outlet.
Disposal of the old air conditioner
Before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment.
It must be noticed that air conditioner system contains refrigerants, which require specialized waste disposal. The valuable materials contained in a air conditioner can be recycled. Contact your local waste disposal center for proper disposal of an old air conditioner and contact your local authority or your dealer if you have any question. Please ensure that the pipework of your air conditioner does not get damaged prior to being picked up by the relevant waste disposal center, and contribute to environmental awareness by insisting on an appropriate, anti-pollution method of disposal.
Disposal of the packaging of your new air conditioner
All the packaging materials employed in the package of your new air conditioner may be disposed without any danger to the environment.
The cardboard box may be broken or cut into smaller pieces and given to a waste paper disposal service. The wrapping bag made of polyethylene and the polyethylene foam pads contain no fluorochloric hydrocarbon.
All these valuable materials may be taken to a waste collecting center and used again after adequate recycling.
Consult your local authorities for the name and address of the waste materials collecting centers and waste paper disposal services nearest to your house.
Safety Instructions and Warnings
Before starting the air conditioner, read the information given in the User's Guide carefully. The User's Guide contains very important observations relating to the assembly, operation and maintenance of the air conditioner.
The manufacturer does not accept responsibility for any damages that may arise due to non-observation of the following instruction.
Damaged air conditioners are not to be put into operation. In case of doubt, consult your supplier.
Use of the air conditioner is to be carried out in strict compliance with the relative instructions set forth in the User's Guide.
Installation shall be done by professional people, don't install unit by yourself.
2
D
L
K1
Temperature Range
If the air conditioner is used under higher temperature condition than those listed, the built-in protection circuit may operate to prevent internal circuit damage. Also, during Cooling and Dry modes, if the unit is used under conditions of lower temperature than those listed above, the heat-exchanger may freeze, leading to water leakage and other damage. Do not use this unit for any other purposes except for the Cooling, (*) Heating, Dehumidifying, and air-circulation of rooms in ordinary dwellings. The wiring method should be in line with the local wiring standand. The waste battery should be disposed properly.
Cooling
Heating
Indoor
outdoor
Rated Maximum Minimum 27 32 18 19 23 14 35 43 -5 24 26 -­ 20 27 15
14.5 -- -­ 7 24 -7 6 18 --
DB C WB C DB C WB C
Indoor
outdoor
DB C WB C
DB C WB C
Cautions
´ Si le fusible de la carte ‡ circuit imprimÈ est cassÈ, veuillez le remplacer avec un fusible de type T 3,15A/250VAC pour líappareil installÈ ‡ líintÈrieur, et de type T1.0A/250VAC T2. 5A/250VAC T25A/250VAC pour líappareil installÈ en extÈrieur, ou remplacez la carte ‡ circuit imprimÈ. ª
Lorsque le climatiseur est installÈ en plafonnier, placer líinterrupteur ´ K1 ª de la carte ‡ circuit imprimÈ sur la position ´ D ª. Lorsque le climatiseur est installÈ au sol, placer cet interrupteur sur la position ´ L ª ó sur les appareils tout neufs, il se trouve par dÈfaut en position ´ D ª.
For this model, the all-pole discon-rexion connection method should be applied in the power supply. Such means for disconnection must be incorporation in the fixed wiring.
All electrical repairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditoiner.
Do not damage any parts of the air conditioner that carry refrigerant by piercing or perforating the air conditioner's tubes with sharp or pointed items, crushing or twisting any tubes, or scraping the coatings off the surfaces. If the refrigerant spurts out and gets into eyes, it may result in serious eye injuries.
Do not obstruct or cover the ventilation grille of the air conditioner. Do not put fingers or any other things into the inlet/outlet and swing louver.
Do not allow children to play with the air conditioner. In no case should children be allowed to sit on the outdoor unit.
Specifications
The refrigerating circuit is leak-proof.
3
Safety Precautions
WARNING!
If the power supply cord of this air conditioner is damaged, it must be replaced by the manufacturer its authorized service personnel only. Use copper wire only. All the cables shall have got the European authentication certificate. the power supply connects from the outdoor side. The power cable and connecting cable are self-provided. The parameter of connecting cable: H05RN-F 4G 0.75mm2. The requirement of the corss section area of the power supply cord: H07RN-F 3G 2.5mm2.
DANGER!
CAUTION!
Do not attempt to install this air conditioner by yourself. This unit contains no user-serviceable parts. Always consult authorized service personnel for repairs. When moving, consult authorized service personnel for disconnection and installation of the unit. Do not become excessively chilled by staying for lengthy periods in the direct cooling airflow. Do not insert fingers or objects into the outlet port or intake grills. Do not start and stop air conditioner operation by connecting and disconnecting the power supply cord and so on. Take care not to damage the power supply cord. In the event of a malfunction (burning smell, etc.), stop operation immediately, turn off the circuit breaker, and consult authorized service personnel.
Provide occasional ventilation during use. Do not direct air flow at fireplaces or heating apparatuses. Do not climb on place objects on the air conditioner. Do not hang objects from the indoor unit. Do not set flower vases or water containers on top of the air conditioner. Do not expose the air conditioner directly to water. Do not operate the air conditioner with wet hands. Do not pull power supply cord. Turn off power source when not using the unit for extended periods. Check the condition of the installation stand for damage. Do not place animals or plants in the direct path of the air flow. Do not drink the water drained from the air conditioner. Do not use in applications involving the storage of foods, plants or animals, precision equipment, or art works. Do not apply any heavy pressure to radiator fins. Operate only with air filters installed. Do not block or cover the intake grill and outlet port. Ensure that any electronic equipment is at least one metre away from either the indoor or outdoor unit. Avoid installing the air conditioner near a fireplace or other heating apparatuses. When installing the indoor and outdoor unit, take precautions to prevent access to infants. Do not use inflammable gases near the air conditioner.
4
Features and Functions
AUTOMATIC OPERATION
SLEEP
HEAT & COOL TYPE
Merely press the ON/OFF button, and the unit will begin automatic operation in any of the Heating, Cooling and Blow modes as appropriate, in accordance with the thermostat setting and the actual temperature of the room.
COOLING TYPE
When the SLEEP button is pressed during Cooling or Dry mode, the thermostat setting gradually rises during the period of operation. When the set time is reached, the unit automatically turns off.
HEAT & COOL TYPE
When the SLEEP button is pressed during Heating mode, the air conditioner's thermostat setting gradually lowers during the period of operation; When the set time is reached, the unit automatically turns off.
WIRELESS REMOTE CONTROL UNIT
The WIRELESS REMOTE CONTROL UNIT allows convenient control of air conditioner operation.
MILDEW-RESISTANT FILTER
The AIR FILTER has been treated to resist mildew growth, thus allowing cleaner use and easier care.
COOLING TYPE
Merely press the ON/OFF button, and the unit will begin automatic operation in the Cooling or dry modes as appropriate, in accordance with the thermostat setting and the actual temperature of the room.
Name of Parts
Fig.1 Indoor Unit
1
4
6 7
3
Fig.2
POWER OPER TIMER COMP
EMER
2
Fig.2 Outdoor Unit
1 Operating Control Panel (Fig.2) 2 Emergency switch 3 Remote Control Signal Receiver 4 Power Indicator Lamp (Red) 5 OPERATION Indicator Lamp (Green) 6 TIMER Indicator Lamp (Yellow) 7 Compressor Run Lamp (Green) 8 Intake Grill (Fig.3) 9 Air Filter
10
UP/DOWN Air Direction Flaps
11
RIGHT/LEFT Air Direction Louvers
(behind UP/DOWN Air Direction Flaps)
3
9
8
Fig.1
1110
1 2 3
4
5
1
3
4
2
5
Air inlet Air outlet
Drain hose
Connecting piping and electrical wiring
6
Installation
WARNING !
CAUTION !
Please ask the dealer or specialist to install, never try by the users themselves. After the installation please
Incorrect installation may cause water leaking, shock and fire hazard.
Please call dealer to install the air-conditioner.
Air-conditioner can't be installed in the envi­ronment with inflammable gases because the inflammable gases near to air-conditioner may cause fire hazard.
Installed electrical-leaking circuit breaker.
Connect earthing wire.
Use discharge pipe correctly to ensure efficient discharge.
[Location]
[Wiring]
[Operating noise]
It easily cause electrical shock without circuit breaker.
Air-conditioner should be located in well-vented and easily-accessible place. Air-conditioner should not be located in the following places: (a) Places with machine oils or other oil vapours. (b) Seaside with high salt content in the air. (c) Near to hot spring with high content of sulfide gases. (d) Area with frequent fluctuation of voltage e.g. factory, etc. (e) In vehicles or ships. (f) Kitchen with heavy oil vapour or humidity. (g) Near to the machine emitting electric-magnetic waves. (h) Places with acid, alkali vapuor. TV, radio, acoustic appliances etc are at least 1 m far away to the indoor unit, outdoor unit, power
Earthing wire should not be con­nected to the gas pipe, water pipe, lightning rod or phone line, in­correct earthing may cause shock.
Incorrect pipe use may cause water leaking.
supply wire, connecting wire, pipes, otherwise images may be disturbed or noises be created. As required, take measures against heavy snow.
Air-conditioner should be equipped with special power supply wire.
Choose the following locations: (a) Capable of supporting air-conditioner weight, don't increase operating noise and vibration. (b) Hot vapour from outdoor unit outlet and ope­ rating noise don't disturb neighbour. No obstacles around the outdoor unit outlet.
Earthing
be sure of the following conditions.