Haier HC18-60A1VAR-S, HC18-60D1VAR, HC18-60C1VAR User Manual

Installation & Operation Manual
Central Air Conditioner
10 to 13 SEER 1.5 to 5 Tons Models: HC18-60A1VAR/S HC18-60C1VAR HC18-60D1VAR
No.0010572324 K
The information contained in this booklet is subject to change without notice.
These instructions are intended as an aid to qualified, licensed service personnel for proper installation, adjustment and operation of this unit. Read these instructions thoroughly before attempting installation or operation. Failure to follow these instructions may result in improper installation, adjustment,
service or maintenance possibly resulting in fire, electrical shock, pr operty damage, personal injury or death. This product is designed and manufactured to permit installation in accordance with National Codes. It is the installer's responsibility to install the product in accordance with National Codes and/or prevailing local codes and regulations. The manufacturer assumes no responsibility for equipment installed
in violation of any codes or regulations.
The United States Environmental Protection Agency (EPA) has issued various regulations r egarding the introduction and disposal of refrigerants in this unit. Failure to follow these regulations may harm
the environment and can lead to the imposition of substantial fines. Because these regulations may vary due to the passage of new laws we suggest that any work on this unit be done by a certified technician. Should you have any questions please contact the local EPA office. The manufacturer's warranty does not cover any damage or defect to the air conditioner caused by the attachment or use of any components, accessories or devices (other than those authorized by the manufacturer) into, onto, or in conjunction with the air conditioner. You should be aware that the use of unauthorized
components, accessories or devices may adversely affect the operation of the air conditioner and may also endanger life and property. The manufacturer disclaims any responsibility for such loss or
injury resulting from the use of such unauthorized components, accessories or devices. Attach the service panel to the outdoor unit securely. If the service panel is not attached securely, it could result in a fire or an electric shock due to dust, water, etc. These instructions are intended as an aid to qualified, licensed service personnel for proper installation, adjustment and operation of this unit. Read these instructions thoroughly before attempting installation or operation. Failure to follow these instructions may result in improper installation, adjustment,
service or maintenance possibly resulting in fire, electrical shock, pr operty damage, personal injury or death. This product is designed and manufactured to permit installation in accordance with National Codes. It is the installer's responsibility to install the product in accordance with National Codes and/or prevailing local codes and regulations. The manufacturer assumes no responsibility for equipment installed
in violation of any codes or regulations.
The United States Environmental Protection Agency (EPA) has issued various regulations r egarding the introduction and disposal of refrigerants in this unit. Failure to follow these regulations may harm
the environment and can lead to the imposition of substantial fines. Because these regulations may vary due to the passage of new laws we suggest that any work on this unit be done by a certified technician. Should you have any questions please contact the local EPA office. The manufacturer's warranty does not cover any damage or defect to the air conditioner caused by the attachment or use of any components, accessories or devices (other than those authorized by the manufacturer) into, onto, or in conjunction with the air conditioner. You should be aware that the use of unauthorized
components, accessories or devices may adversely affect the operation of the air conditioner and may also endanger life and property. The manufacturer disclaims any responsibility for such loss or
injury resulting from the use of such unauthorized components, accessories or devices. Attach the service panel to the outdoor unit securely. If the service panel is not attached securely, it could result in a fire or an electric shock due to dust, water, etc.
Message to Owner
These instructions should be carefully read and kept near the product for future reference. While the instructions are addressed primarily to the installer, useful maintenance information is included. Have your installer acquaint you with the operating characteristics of the product and periodic maintenance requirements.
TABLE OF CONTENT
1.Introduction ---------------------------------------------------------------------------------------
2.Nomenclature for Model Number -------------------------------------------------------------
3.Specification -------------------------------------------------------------------------------------
4.Unit Inspection -----------------------------------------------------------------------------------
5.Equipment Protection From Environment ----------------------------------------------------
6.Installation ----------------------------------------------------------------------------------------
6.1. General ---------------------------------------------------------------------------------------
6.2.Unit clearances ------------------------------------------------------------------------------
6.3.Refrigerant piping ---------------------------------------------------------------------------
6.4.Electrical wiring -----------------------------------------------------------------------------
7.System Startup -----------------------------------------------------------------------------------
8.Operation ----------------------------------------------------------------------------------------
9.Miscellaneous -----------------------------------------------------------------------------------
9.1.Replacement parts --------------------------------------------------------------------------
9.2.Troubleshooting guide ---------------------------------------------------------------------
1 1 2 5 5 5 5 6
6 10 11 12 12 12 12
9.3.Wiring diagram -----------------------------------------------------------------------------
1.INTRODUCTION
This manual contains the installation and operating instructions for your new air conditioner. Improper installation can result in unsatisfactory operation or dangerous conditions. Carefully read this manual and any instructions packaged with separate equipment required to make up the system prior to installation. Give this manual to the owner and explain its provisions. The owner should retain this manual for future reference.
2.NOMENCLATURE FOR MODEL NUMBER
H Brand symbol - H: Haier C System type - C: Air conditioner; R: Heat pump. 24 Nominal capacity in (000) Btuh A SEER designation. A=10, B=11, C=12, D=13, E=14 1 Design series. 1 - 1st Generation V Electric: V=208/230-1-60; C=208/230-3-60, D=460-3-60, Y=575-3-60 A Body style
12
R Compressor type Example: HC24A1VAR
1
3.SPECIFICATION
The dimensions for the condensing unit are illustrated in Figure 1. Physical and electrical specifications are provided in Table 1 for 10 SEER systems respectively.
Table 1:
Model:HC18-60A1VAR/S
HC60A1VARHC48A1VARHC42A1VARHC36A1VASHC30A1VARHC24A1VARHC18A1VAR
208/230-1-60
H29A
Bristol
H20R
Sanyo Bristol Sanyo Bristol Sanyo
197 - 253
50
22.6
40 35 45 50 60
18.3 15.8 21.3 24.4 26.9 28.9
147
130 90 130 140 149 165
1.43 1.43 1.43
1/3 1/3 1/3
1075 1075 1075
3/8" [9.52] 3/8"[9.52] 3/8"[9.52]
3/4"[19.05] 3/4"[19.05] 7/8"[22.2]
115.19[3260] 122.97[3480] 128.27[3630] 137.81[3900] 141.34[4000]
30 1/4*30 1/4*31 1/2 30 1/4*30 1/4*31 1/2 30 1/4*30 1/4*35 1/2
[770 *770*805] [ 770 *770*805] [ 770 *770*905]
32 3/4*32 3/4*36 32 3/4*32 3/4*36 32 3/4*32 3/4*40 1/2
[832*832*930] [ 832*832*930] [832*832*1030]
209[95] 198[90] 209[95] 200[91] 220[100] 216[98]
231[105] 222[101] 231[105] 222[101] 246[112] 242[110]
MODEL:
Unit Supply Voltage
Normal Voltage Range
Bristol
12.9 16.2 19.4 24.3 21.2 28.1 31.9 35.1 37.6 29.7
10.1
15 20 25 30
Compressor Brand
Max Fuse or Max CKT. BKR.
Minimum Circuit Amps
Rated Load Amps 7.4 9.6 11.8 14.4
(HACR per NEC )
Compressor Locked Running
Amps 48 60 73 88
Full Load Amps 0.86 0.86 1.4 1.4
Fan Motor Rated HP 1/8 1/8 1/5 1/5
Nominal RPM 850 1000 1075 1075
Liquid Line OD - In (mm) 3/8"[9.52] 3/8"[9.52] 3/8"[9.52] 3/8"[9.52]
Vapor Line OD - In (mm) 5/8"[15.88] 5/8"[15.88] 3/4"[19.05] 3/4"[19.05]
R-22 Charge -Oz (g) 49.47[1400] 63.60[1800] 88.34[2500] 93.64[2650]
Net Dimensions - In (mm) 23*23*24 23*23*24 23*23*31 1/2 23*23*31 1/2
W*D*H [585 *585*605] [585 *585*605] [ 585 *585*805] [ 585 *585*805]
Shipping Dimensions - In (mm) 25*25*28 1/4 25*25*28 1/4 25*25*36 25*25*36
W*D*H [632*632*719] [632*632*719] [632* 632*919] [632* 632*919]
Net Weight - Lbs (kg) 123[56] 125[57] 134[61] 141[64]
Approx Shipping Weight - Lbs (kg) 141[64] 143 [65] 158[72] 165[75]
2
D
W
Figure 1
Table 2:System Cooling Capacity
Outdoor Unit With This Indoor Air handler Model Number
Air Handler
HC18A1VAR HB2400VA1M20 HC24A1VAR HB2400VA1M20 HC30A1VAR HB3000VA1M20 HC36A1VAS HB3600VA1M20 HC42A1VAR HB4200VA1M25
HC48A1VAR HB4800VA1M25
HC60A1VAR HB6000VA1M25
Compressor brand
Bristol Bristol
Bristol Bristol
Sanyo
Bristol
Sanyo
Bristol
Sanyo
Bristol
Cooling Capacity (Btu/h) SEER Rated Sensible Total CFM(Outdoor)
13000 17000 20000
24000 28400 29160 33120
33120 40170
40180
18000 24000 28000 34000 40000 40500 46000
46000 55800
56000
10 10 10 10
10 10 10 10
10 10
1850 1850 1950 1950
2700 2700 2900 2900
2900 2900
The dimensions for the condensing unit are illustrated in Figure 1. Physical and electrical specifications are provided in Table 3 for 12 SEER systems respectively.
H
Table 3:
Model:HC18-60C1VAR
MODEL: HC18C1VAR HC24C1VAR HC30C1VAR HC36C1VAR HC42C1VAR HC48C1VAR HC60C1VAR Unit Supply Voltage
Normal Voltage Range
208/230-1-60 197 - 253
Bristol Compressor Brand Minimum Circuit Amps
Bristol
H29A
H20J
10.1 13.4 16.2 17.7 22.3 21.2
H29A H23R
34.724.8 37.6 38.5
H20R
H23R
Max Fuse or Max CKT. BKR. (HACR per NEC )
15 25 25 30 40 35 40 60 60 Rated Load Amps 7.4 9.6 11.8 13.0 16.7 15.8 18.7 26.6 28.9
60
28.8 Compressor Locked Running Amps 48 60 73 85 105 90 135 155 165 Full Load Amps 0.86 1.4 1.4 1.43 1.43 1.43 1.43 Fan Motor Rated HP 1/8 1/5 1/5 1/3 1/3 1/3 1/3
145
2.5
1/2 Nominal RPM 850 1075 1075 1075 1075 1075 1075 Liquid Line OD - In (mm) 3/8"[9.52] 3/8"[9.52] 3/8"[9.52] 3/8"[9.52] 3/8" [9.52] 3/8"[9.52] 3/8"[9.52] Vapor Line OD - In (mm) 5/8"[15.88] 3/4"[19.05] 3/4"[19.05] 3/4"[19.05] 7/8"[22.2] 7/8"[22.2] 7/8"[22.2] R-22 Charge -Oz (g) 74.2 [2100] 91.87[2600] 88.34[2500] 102.47[2900] 132.51[3750] 125.44[3550]
120.14[3400] 127.21[3600]
171.38[4850]
183.75[5200] Net Dimensions - In (mm) 23*23*27 3/4 23*23*27 3/4 23*23*31 1/2 30 1/4*30 1/4*27 3/4 30 1/4*30 1/4*35 1/2 301/4*30 1/4*35 1/2 30 1/4*30 1/4*31 1/2 W*D*H [585* 585*705] [585* 585*705] [585* 585*805] [770 *770*705] [770 *770*905] [770 *770*905] [ 770 *770*805] Shipping Dimensions - In (mm) 25*25*32 1/4 25*25*32 1/4 25*25*36 32 3/4*32 3/4*32 1/2 32 3/4*32 3/4*40 1/2 32 3/4*32 3/4*40 1/2 32 3/4*32 3/4*36 W*D*H [632* 632*819] [632* 632*819] [632* 632*919] [832*832*830] [832*832*1030] [832*832*1030] [832* 832*930] Net Weight - Lbs (kg) 123[56] 125[57] 139[63] 196[89] 231[105] 238[108] 298[135] Approx Shipping Weight - Lbs (kg) 141[64] 143[65] 152[69] 222[101] 257 [117] 264[120] 321[146]
3
Table 4:System Cooling Capacity
Outdoor Unit With This Indoor Air handler Model Number
HC18C1VAR HB2400VC1M20 HC24C1VAR HB2400VC1M20 HC30C1VAR HB3600VA1M20 HC36C1VAR HB3600VC1M25 HC42C1VAR HB4800VA1M25 HC48C1VAR HB4800VA1M25 HC60C1VAR HB6000VC1M25
Air Handler
Compressor brand
Bristol Bristol
Bristol Bristol
Bristol Bristol Bristol
Cooling Capacity (Btu/h) SEER Rated Sensible Total CFM(Outdoor)
14820 18720 23400
25920 30240 34560 41800
19000 24000 30000 36000 42000 48000 58000
12 12 12 12
12 12 12
1950 1950 1950 2700
2900 2900 2900
The dimensions for the condensing unit are illustrated in Figure 1. Physical and electrical specifications are provided in Table 5 for 13 SEER systems respectively.
Table 5:
MODEL: HC18D1VAR HC24D1VAR HC30D1VAR HC36D1VAR HC42D1VAR HC48D1VAR HC60D1VAR Unit Supply Voltage
Normal Voltage Range Compressor Brand
Minimum Circuit Amps Max Fuse or Max CKT. BKR.
(HACR per NEC )
15 20 20 25 30 35 55 Rated Load Amps 6.2 8.6 9.2 11.7 13.0 15.8 25.0 Compressor Locked Running Amps 41 60 60 73 85 90 150 Full Load Amps 0.86 0.86 0.86 1.3 1.43 2.0 2.0 Fan Motor Rated HP 1/8 1/6 1/6 1/4 1/3 1/3 1/3 Nominal RPM 1000 840 840 850 1075 960 880 Liquid Line OD - In (mm) 3/8"[9.52] 3/8"[9.52] 3/8"[9.52] 3/8"[9.52] 3/8" [9.52] 3/8"[9.52] 3/8"[9.52] Vapor Line OD - In (mm) 3/4"[19.05] 3/4"[19.05] 3/4"[19.05] 7/8"[22.2] 7/8"[22.2] 7/8"[22.2] 7/8"[22.2] R-22 Charge -Oz (g) 93.64[2650] 102.47[2900] 121.91[3450] 134.28[3800] 148.41[4200] 178.45[5050] 196.11[5550] Net Dimensions - In (mm) 23*23*31 1/2 30 1/4*30 1/4*27 3/4 30 1/4*30 1/4*31 1/2 30 1/4*30 1/4*31 1/2 30 1/4*30 1/4*35 1/2 30 1/4*30 1/4*31 1/2 30 1/4*30 1/4*35 1/2 W*D*H Shipping Dimensions - In (mm) 24 3/4*24 3/4*36 32 3/4*32 3/4*32 1/2 32 3/4*32 3/4*36 32 3/4*32 3/4*36 32 3/4*32 3/4*40 1/2 32 3/4*32 3/4*36 32 3/4*32 3/4*40 1/2 W*D*H Net Weight - Lbs (kg) 156[71] 194[88] 198[90] 203[92] 231[105] 244[111] 258[117] Approx Shipping Weight - Lbs (kg) 167[76] 209[95] 216[98] 220[100] 249 [113] 262[119] 282[128]
Model:HC18-60D1VAR
8.6 11.6 12.4 15.9
[585* 585*805]
[632* 632*919]
[770* 770*705]
[832* 832*830]
[
[770* 770*805]
832* 832*930]
208/230-1-60
197 - 253 Bristol
17.7 21.8 33.3
[770 *770*805] [770 *770*905] [770 *770*805] [ 770 *770*905]
[832*832*930] [832*832*1030] [832*832*930] [832*832*1030]
Table 6:System Cooling Capacity
Outdoor Unit With This Indoor Air handler Model Number
HC18D1VAR HB2400VD1M20 HC24D1VAR HB2400VD1M20 HC30D1VAR HB3600VD1M22 HC36D1VAR HB3600VD1M22 HC42D1VAR HB4800VD1M22 HC48D1VAR HB4800VD1M22 HC60D1VAR HB6000VD1M22
Air Handler
Compressor brand
Bristol Bristol
Bristol Bristol
Bristol Bristol Bristol
Cooling Capacity (Btu/h) SEER Rated Sensible Total CFM(Outdoor)
13300 17700 20669
25900 29600 34800 40700
4
18000 24000 28000 35000 40000 47000
55000
13 13 13 13
13 13 13
1350.0
1800.0 2100 2700 3200 3600 4000
Loading...
+ 11 hidden pages