Haier HDU-42HF03/H, HDU-42HK03, HDU-42HK03/H, HDU-42CI03/H, HDU-50HT03/H Installation Instructions Manual

...
ROOM AIR CONDITIONER
OUTDOOR UNIT
No.0010576723 H
Before using the air conditioner,please read this manual carefully. Please keep this manual properly for future use.
CONTENTS
INSTALLATION INSTRUCTIONS
HBU-42CF03 HDU-42CF03/H HBU-42HF03 HDU-42CH03/H
HBU-28CF03
HBU-28HF03
HDU-42HF03/H HDU-42CI03/H HDU-42HK03/H HDU-50HT03/H
Name of Parts
1
HBU-42CF03 HBU-42HF03 HDU-42CF03/H HDU-42CH03/H
HBU-28CF03
Air inlet
Air outlet
(Inside of unit)
Compressor
Air inlet
Air outlet
(Inside of unit)
Compressor
HBU-28HF03
Air inlet
Air outlet
(Inside of unit)
Compressor
Air inlet
Air outlet
(Inside of unit)
Compressor
HDU-42HF03/H HDU-42CI03/H HDU-42HK03/H
HDU-50HT03/H
Below are listed three kinds of Safety Cautions and Suggestions.
WARNING!
CAUTION!
Incorrect operations may result in injuries or machine damages; in some cases may cause serious consequences.
Incorrect operations may result in severe consequences of death or serious injuries.
INSTRUCTIONS: These information can ensure the correct operation of the machine.
Be sure to conform with the following important Safety Cautions.
The Safety Cautions should be at hand so that they can be checked at any time when needed.
If the conditioner is transferred to the new user, this manual should be as well transferred to the new user.
Safety Cautions
Carefully read the following information in order to operate the airconditioner correctly.
WARNING!
If any abnormal phenomena is found
(e. g.smell of firing), please cut off the
power supply immediately, and contact
the dealer to find out the handling
method.
Don't dismantle the outlet of the outdoor unit.
The exposure of fan is very dangerous whichmay harm human beings.
switch
off
In such case, to continue using the
conditioner will damage the conditioner,
and may cause electrical shock or fire
hazard.
Incorrect maintenance and repairment
may cause water leak, electrical shock
and fire hazard.
When need maintenance and repairment,
call dealer to handle it.
After a long time use of air-conditioner the base should be checked for any damages.
If the damaged base is not repaired, the unit may fall down and cause accidents.
2
Air-conditioner can't be installed in the environment with inflammable gases because the inflammable gases near to air-conditioner may cause fire hazard.
Connect earthing wire.
Use discharge pipe correctly to ensure efficient discharge.
Earthing wire should not be con­nected to the gas pipe, water pipe, lightning rod or phone line, in­correct earthing may cause shock.
Incorrect pipe use may cause water leaking.
Earthing
Safety Cautions
WARNING!
Installed electrical-leaking circuit breaker.
It easily cause electrical shock without circuit breaker.
Please let the dealer be responsible for installing the conditioner.
Incorrect installation may cause water
leak, electrical shock and fire hazard.
Call the dealer to take measures to
prevent the refrigerant from leaking.
If conditioner is installed in a small
room be sure to take every measure in
order to prevent suffocation accident
even in case of refrigerant leakage.
When conditioner is deinstalled or
reinstalleddealer should be respon-
sible for them.
Incorrect installation may cause water
leaking, electrical shock and fire hazard.
No goods or nobody is permitted to placed on or stand on outdoor unit.
The falling of goods and people may cause accidents.
Don't operate the air-conditioner with damp hands.
Otherwise will be shocked.
Only use correctly-typed fuse.
May not use wire or any other materials replacing fuse, other-wise may cause faults or fire accidents.
3
Note : (1). Fix the parts with screws (2).Don't intake the strong wind directly to the
outlet air-flow hole. (3).A one meter distance should be kept from the
unit top (4).Don't block the surroundings of the unit with
sundries
Installation Procedure
2. Selection of the place of installation
1. Accessories
"Edging" for protection of electric wires from an opening edge.
Select the place of installation satisfying the following conditions and, at the same time, obtain a consent from the client or user.
Edging
Place where air circulates. Place free from heat radiation from other heat sources. Place where drain water may be discharged. Place where noise and hot air may not disturb the neighborhood. Place where there is not heavy snowfall in the winter time. Place where obstacles do not exist near the air inlet and air outlet . Place where the air outlet may not be exposed to a strong wind. Place surrounded at four sides are not suitable for installation. A 1m or more of overhead space is needed for the unit. Mount guide-louvers to place where short-circuit is a possibility. When installing several units, secure sufficient suction space to avoid short circuiting.
Wind direction
NO
(2) Installation where the area with strong winds.
Install the unit so that the air outlet section of the unit must NOT be faced toward wind direction.
(1) Open space requirement around the unit
L
2
L
3
L
1
500
(Servicing space)
Air outlet
Air inlet
Air inlet
Case
Distance
Unit: mm
open
open
open
500
150
150
300
300
0
L
1
L2
L3
I
II
III
Installation of outdoor unit
4
Loading...
+ 9 hidden pages