Contents
Cautions
.....................................................................................................
Introduction to Spare Parts
............................................................................
Maintenance
.............................................................................................
Trouble Shooting
...................................................................................
When Trouble Happens
.........................................................................
Customer Need-to-know
..............................................................................
Precaution for Installation
...........................................................................
Installation Tools
..........................................................................................
Installation Procedure
..............................................................................
Name of Parts
..............................................................................................
Safety Cautions .......................................................................................
Installation Procedure
.............................................................................
1-5
6
7-10
11-12
13-14
15
16
17
18-29
30
31-32
33-42
outdoor unit
indoor unit
Cautions
1
Disposal of the old air conditioner
Before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment.
It must be noticed that air conditioner system contains refrigerants, which require specialized waste disposal. The valuable materials contained in a air conditioner can be recycled. Contact your local waste disposal center for proper disposal of an old air conditioner and contact your local authority or your dealer if you have any question. Please ensure that the pipework of your air conditioner does not get damaged prior to being picked up by the relevant waste disposal center, and contribute to environmental awareness by insisting on an appropriate, anti-pollution method of disposal.
Disposal of the packaging of your new air conditioner
All the packaging materials employed in the package of your new air conditioner may be disposed without any danger to the environment.
The cardboard box may be broken or cut into smaller pieces and given to a waste paper disposal service. The wrapping bag made of polyethylene and the polyethylene foam pads contain no fluorochloric hydrocarbon.
Consult your local authorities for the name and address of the waste materials collecting centers and waste paper disposal services nearest to your house.
Safety Instructions and Warnings
Before starting the air conditioner, read the information given in the User's Guide carefully. The User's Guide contains very important observations relating to the assembly, operation and maintenance of the air conditioner.
The manufacturer does not accept responsibility for any damages that may arise due to non-observation of the following instruction.
Damaged air conditioners are not to be put into operation. In case of doubt, consult your supplier.
Use of the air conditioner is to be carried out in strict compliance with the relative instructions set forth in the User's Guide.
Installation shall be done by professional people, don't install unit by yourself.
All these valuable materials may be taken to a waste collecting center and used again after adequate recycling.
For the purpose of safety, the air conditioner must be properly grounded in accordance with specifications.
Always remember to unplug the air conditioner before opening inlet grill. Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the outlet.
3. The wiring method should be in line with the local wiring standard.
4. The power cable and connecting cable are self-provided. The requirement of the power cable:
All the cables shall have got the European authentication certificate.
5. The breaker of the air conditioner should be all-pole switch; and the distance between its two contacts should be no less 3mm. Such means for disconnection must be incorporation in the fixed wiring.
6. The waste battery shall be disposed properly.
7. The indoor unit installation height is at least
2.5m.
All electrical repairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditoiner.
Do not damage any parts of the air conditioner that carry refrigerant by piercing or perforating the air conditioner's tubes with sharp or pointed items, crushing or twisting any tubes, or scraping the coatings off the surfaces. If the refrigerant spurts out and gets into eyes, it may result in serious eye injuries.
Do not obstruct or cover the ventilation grille of the air conditioner. Do not put fingers or any other things into the inlet/outlet and swing louver.
Do not allow children to play with the air conditioner. In no case should children be allowed to sit on the outdoor unit.
Specifications
The refrigerating circuit is leak-proof.
1. Applicable ambient temperature range:
The machine is adaptive in following situation
Model
2. If the supply cord is damaged, it must be replaced by the manufacturer or its service agentor a similar qualified person.
Cooling
Indoor
outdoor
Rated Maximum Minimum 29 32 21 19 23 15 46 52 21 24 31 -
DB C WB C DB C WB C
Cautions
Power Cable
5G 4.0mm
2
5G 2.5mm
2
2
HBU-24CA03T3
HBU-36CA03T3
HBU-42CA03T3
HBU-50CA03T3
HBU-60CA03T3
HBU-18CA03T3
WARNING!
Carefully read the following information in order to operate the airconditioner correctly.
Below are listed three kinds of Safety Cautions and Suggestions.
WARNING!
CAUTION!
Incorrect operations may result in injuries or machine damages; in some cases may cause serious consequences.
Incorrect operations may result in severe consequences of death or serious injuries.
INSTRUCTIONS: These information can ensure the correct operation of the machine.
Be sure to conform with the following important Safety Cautions.
The Safety Cautions should be at hand so that they can be checked at any time when needed.
If the conditioner is transferred to the new user, this manual should be as well transferred to the new user.
Otherwise the one
will feel unpleasant
or harm ones' health.
If any abnormal phenomena is found (e. g.
smell of firing), please cut off the power
supply immediately, and contact the dealer
to find out the handling method.
In such case, to continue
using the conditioner will
damage the conditioner,
and may cause electrical
shock or fire hazard.
When need maintenance and repairment,
call dealer to handle it.
Incorrect mainten-
ance and repairment
may cause water
leak, electrical shock
and fire hazard.
switch
off
Please let the dealer be responsible for installing
the conditioner.
Incorrect installation may cause water leak, elec-
trical shock and fire hazard.
Don't put fingers or any other things into the
inlet/outlet and swing louver while the condi-
tioner is in operation.
Because the highspeed
fan is very dangerous
and may cause injuries.
Call the dealer to take measures to prevent the
refrigerant from leaking.
If conditioner is installed in a small room be sure
to take every measure in order to prevent suffoca-
tion accident even in case of refrigerant leakage.
When conditioner is deinstalled or reinstalled
dealer should be responsible for them.
Incorrect installation may cause water leaking,
electrical shock and fire hazard.
Don't blow the human body with the cooling
air too long, and don't let the room tempera-
ture decrease too low
either.
Safety cautions
Cautions
3
CAUTIONS!
Conditioner should not be used for any other
purpose other than airconditioning.
Don't use air-conditioner for any other special purposes, e.g. the preservation and protection of food, animals, plants, pecision apparatus as well as work of art, otherwise the qualities of these stuffs may be damaged.
Don't dismantle the outlet of the outdoor unit.
The exposure of fan is very dangerous which may harm human be­ings.
When air-conditioner is co-used with other heat-radiator the frequent replacement of room atmosphere should be required.
Inefficient venti­lation may cause suffocation.
After a long time use of air-conditioner the base should be checked for any damages.
If the damaged base is not repaired, the unit may fall down and cause accidents.
No goods or nobody is permitted to placed on or stand on outdoor unit.
The falling of goods and people may cause acci­dents.
Pets and plants should not be blowed directly in the air flow.
Otherwise will suffer damage.
Don't operate the air-con­ditioner with damp hands.
Otherwise will be shocked.
Only use correctly-typed fuse.
May not use wire or any other materials replacing fuse, other­wise may cause faults or fire accidents.
Don't place any burning unit in the air flow of air-conditioner, which may cause incomplete combustion.
No inflammable spray fluid should be permitted to be placed or used near to air­conditioner otherwise may cause fire accidents.
Air-conditioner should be cleaned only after power supply is cut off to keep from shock or hurt.
Don't clean air-conditioner with water.
Otherwise may cause shock.
Otherwise the poisonous chemicals may settle in air-conditioner which harm the health of chemical-allergic people.
When use the fumigating insecticide don't open air-conditioner.
Cautions
4
WARNING !
CAUTION !
Please ask the dealer or specialist to install, never try by the users themselves. After the installation
please be sure of the following conditions.
Incorrect installation may cause water leaking, shock and fire hazard.
Please call dealer to install the air-conditioner.
Air-conditioner can't be installed in the envi­ronment with inflammable gases because the inflammable gases near to air-conditioner may cause fire hazard.
Installed electrical-leaking circuit breaker.
Connect earthing wire.
Use discharge pipe correctly to ensure efficient discharge.
[Location]
[Wiring]
[Operating noise]
It easily cause electrical shock without circuit breaker.
Air-conditioner should be located in well-vented and easily-accessible place. Air-conditioner should not be located in the following places: (a) Places with machine oils or other oil vapours. (b) Seaside with high salt content in the air. (c) Near to hot spring with high content of sulfide gases. (d) Area with frequent fluctuation of voltage e.g. factory, etc. (e) In vehicles or ships. (f) Kitchen with heavy oil vapour or humidity. (g) Near to the machine emitting electric-magnetic waves. (h) Places with acid, alkali vapuor. TV, radio, acoustic appliances etc are at least 1 m far away to the indoor unit, outdoor unit, power supply wire, connecting wire, pipes, otherwise images may be disturbed or noises be created.
Earthing wire should not be con­nected to the gas pipe, water pipe, lightning rod or phone line, in­correct earthing may cause shock.
Incorrect pipe use may cause water leaking.
As required, take measures against heavy snow.
Air-conditioner should be equipped with special power supply wire.
Chose the following locations: (a) Capable of supporting air-conditioner weight, don't increase operating noise and vibration. (b) Hot vapour from outdoor unit outlet and ope­ rating noise don't disturb neighbour. No obstacles around the outdoor unit outlet.
Earthing
Installation
Cautions
5
Introduction to Spare Parts
6
Swing louver
(Air flow direction can be adjusted by using the SWING button on the remote controller)
Air Inlet Grille
Air Filter
(Inside of the Inlet Grille)
Operating Control Panel
Indoor unit
Drain Hose
Swing fender
Refrigerant pipe Cable line Earthing line
Air filter
Outlet
Suction grill
(located in the suction grill)
In cooling operation, to discharge the water from inside the room.
Discharge unit (built in)
(located in the outlet)
HBU-18CA03T3 HBU-24CA03T3 HBU-36CA03T3 HBU-42CA03T3 HBU-50CA03T3
HBU-60CA03T3
.
Maintenance
[Clean air filter]
NOTE
1. Open inlet grill
When having to clean, don't dismantle air-filter,otherwise may cause faults. In the environment where there is too much dust, air filter should be cleaned for more times. (about half a year one time)
(B) Wash with water.
With too much dust, use soft brush and neutral
detergent.
Swing off the water, and then place in cool place.
Pull the two handles at the same time, slowly draw them out.
¢
¢
2. Dismantle air filter
clip cpening
bottom of filter
frame of air inlet grill
¢
CAUTION!
3. Clean
(A) Remove dust with vacuum filter.
¢
¢
4. Install air filter
Put filter into protruding parts at the top of the
inlet grill.
¢
7
remove the air inlet grill
5. Close inlet grill
the reverse sequance of 1.
8. Dismantle air filter
9. Install air filter
(1) Put filter into protruding parts at the top ofthe
inlet grill.
(2) Connect the two pothooks with inlet grill. See 7.
Connet the two pothooks with inlet grill
[Clean inlet grill]
1. Open inlet grill
10. Close inlet grill
11. Press the filter signal return key on the
controller.
See 6.
'' ''
Maintenance
6. Open inlet grill
Press the elliptical "PUSH" knob, the inlet grill will
automatically drop. (the inlet grill is catched with
two pothooks)
PUSH
Press the elliptical knob the inlet grill will automatically drop
Open two pothooks
Pothook
3. Take of inlet grill
4. Clean
CAUTION!
NOTE
When the filter too much dust
To spray the special detergent for vent fan or
utensils.
2. Take off airfilter
7.Open two pothooks
8
Press the elliptical "PUSH" knob, the inlet grill
will automatically drop. (the inlet grill is catched
with two pothooks)
PUSH
Press the elliptical knob the inlet grill will automatically drop
Open two pothooks
Pothook
Drag the knob of the grill back lift the filter and take down.
Air filter
[Clean outlet and shell]
CAUTION!
Don't use gasoline, benzene, dilutant, polishing
powder, or liquid inseticide.
5. Install inlet grill
6. Install air filter
7. Close inlet grill
[Clean outlet and shell]
see 3
see "Clean air filter"
see 1
CAUTION!
Don't use gasoline, benzene, dilutant,
polishing powder, or liquid inseticide.
[Dismantle and install swing plate ]
1. Fix the swing plate at the bottom.
2. Dismantle the swing plate.
CAUTION!
Use water to clean the plate and don't heavily
scrub, otherwise the fine hair may fall off. Unscrew the screw at both ends of the swing
plate.
[Dismantle and install swing plate ]
3. Install swing plate
Lightly rotate swing plate to insert the ridge
at both ends of the outlet into the groove
and then screw up.
Maintenance
9
NOTE
1. The inner part of indoor unit must be cleaned. Consult dealer, because clean must be done by
technician.
2. In cooling operation, discharging system discharge water in room.
Seasonal Reserve
Operate the unit with FAN mode on a fair day for about half a day to dry the inside of the unit well.
Stop operation and turn off the power supply switch .Electric power is consumed even the air conditioner is in stop.
Clean the air filter, indoor unit and outdoor unit,and cover the unit with dustcoat.
Pre-season Care
See that there is no obstacles blocking the air inlet and air outlet of both indoor and outdoor unit to avoid reduce the working efficiency.
Be sure to install the air filter, ensure that the air filter is not dirty. Otherwise may result in machine damages or cause malfunciton due th dust inside the unit
To prevent compressor when start in HEAT mode, please cut in the power supply switch 12 hours before starting run,furthermore, always keep the power supply switch on during the using senson.
Post-season Care
Maintenance
10
The followings are not malfunction
Hua
Hua
Water flowing sound is heard When the air conditoner is started, when the
compressor starts or stops during operation or when the air conditioner is stopped,it som­etimes sounds "Bi- Bi-"or "Godo-Godo". It is the flowing sound of the refrigerant , not a malfunction.
Cracking sound is heard
It smells.
This is caused by heat expansion or contraction of plastics.
Air blown out from the indoor unit sometimes smells. The smell results from smells of furniture, paint , tobacco absorbed by indoor unit.
During operation, white fog comes out of indoor unit.
When in COOL or DRY mode, a thin water fog can be seen blown out of unit ,this is the condensed fog because the suddenly cooled indoor air is blown out.
Automatically switch into FAN mode during cooling.
To prevent frost from being accumulated on the indoor unit heat exchanger, it sometimes auto­matically switched into the FAN mode,but it will soon back to the cooling mode.
The air conditioner cannot be restarted soon after it stops. Air conditioner does not start?
This is because of the self-protection function of the system, therefore,it cannot be restarted for about three minutes after it stops.
Please wait for three minutes
11
Trouble Shooting
Trouble Shooting
**?
ON
OFF
Air does not blow or the fan speed cannot be changed during drying.
In DRY mode, when room temperature becomes 2 ¡ higher than temperature setting, unit rill run intermittently at LO speed regardless of FAN setting
During heating,indoor fan is still running even unit is stopped.
To get ride of the excess heat, indoor fan will continue running for a while after unit autom­atically stops.
Water or vapor generated from the outdoor unit during heating.
Please check the following things about your air conditioner before making a service call.
Unit fails to start.
Is the power supply switch on ?
Power supply switch is not in ON position.
Is city supply power normal ?
Is the earth leakage breaker in action ?
Be sure to turn off the power supply switch immediately and contact the sales dealer.
This happens when the frost accumulated on the outdoor unit is removed (during defrosting operation).
Defrosting operation
12