Haier HB80 User Manual

Page 1
Page 2
HB80 Single Door Vertical Cooler Installation and Operating Instructions
MAN6819 Rev. 1.0 Oct. 2006 edition.
Copyright © 2006 SKOPE Industries Limited. All rights reserved.
SKOPE Industries Limited reserve the right to alter specifications without notice.
is a registered trade
mark of SKOPE Industries Limited.
TRADE MARK INFRINGEMENT
The SKOPE trade mark on this product is infringed if the owner, for the time being, does any of the following:
•Applies the trade mark to the product after their state, condition, get-up or packaging has been altered in any manner
•Alters, removes (including part removal) or obliterates (including part obliteration) the trade mark on the product
•Applies any other trade mark to the product
•Adds to the product any written material that is likely to damage the reputation of the trade mark
Notice of the above contractual obligations passes to:
•Successors or assigns of the buyer
•Future owners of the product
i
Single Door Vertical Cooler
HB80
Page 3
TABLE OF CONTENTS
1INSTALLATION
1.1Safety Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
1.2Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
1.3Positioning the Cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
2OPERATION
2.1Cabinet Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
2.2Loading . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
2.3Temperature Adjustment. . . . . . . . . . . . . . . . . . . . . . . . . . . .9
3MAINTENANCE
3.1Cabinet Light. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
3.2Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
3.3Advanced Servicing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
3.4Contact Addresses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
HB80
Single Door Vertical Cooler
ii
Page 4
INSTALLATION
1
1.1Safety Information
When using any electrical appliance, safety precautions should always be observed. Read these instructions carefully and retain for future reference.
•This appliance is not intended for use by young or infirm persons unless they have been adequately supervised by a responsible person to ensure that they can use the appliance safely. Young children should be supervised to ensure that they do not play with the appliance.
•Disconnect the cabinet from the mains power supply before attempting any cleaning or maintenance.
•Do NOT use this appliance for other than its intended use.
•Do NOT cover the grilles or block the entry or exhaust of airflow by placing objects up against the refrigeration unit.
•Do NOT probe any opening.
•Only use this appliance with voltage specified on the rating label.
•Ensure adequate ventilation of the refrigeration unit.
•Be careful not to touch moving parts and hot surfaces.
•Regulations require that all electrical work be carried out by authorised persons. For your own safety, and that of others, ensure this is done.
•If the supply cord becomes damaged, it must be replaced by a SKOPE authorised service agent, or similarly qualified person, in order to avoid a hazard.
Disposal
Care must be taken when disposing of this product to avoid hazards. Please contact SKOPE Customer Services for advice regarding disposal of this product.
4
Single Door Vertical Cooler
HB80
Page 5
INSTALLATION
1
1.2Unpacking
Remove all packing material from the inside and outside of the cabinet, including the foam base and all adhesive tape holding the cabinet accessories.
Shelves
Remove the packing material from both shelves and then position the shelves into the cabinet at the desired heights. The bottom shelf has hooks on the back which lock the shelf in position.
Evaporator Fan
HB80
Single Door Vertical Cooler
Top Shelf
Bottom Shelf
Figure 1: Cabinet Shelves
5
Page 6
INSTALLATION
1
1.3Positioning the Cabinet
Power Supply
This cooler is rated 220-240 V a.c. and will draw a maximum of 1.1 Amps. Do not overload the power supply. The 3-core mains flex, which exits behind the refrigeration unit, should be retrieved before the cabinet is positioned.
Ventilation
When positioning the cabinet, adequate clearance must be maintained for ventilation. For efficient operation of the cooler, it is essential that adequate ventilation be provided around the cabinet. Normal maximum operating conditions are 40°C at 40% RH (Climatic Class 5).
This cooler should not be recessed or enclosed in a cabinet. It is designed for free-standing installation only. The recommended clearance on both sides and at the back of the cabinet is 50mm.
Location
When positioning the cabinet:
•Avoid direct sunlight and warm draughts etc.
•Allow adequate space for the door to open fully.
•Ensure the cabinet is positioned on a level surface so the door shuts and seals correctly, and to prevent the condensate tray from overflowing.
Levelling
This cooler has a levelling bolt located underneath the door hinge. After final positioning, the levelling bolt can be adjusted to stabilise the cabinet. Turn the levelling bolt clockwise to raise or anti­clockwise to lower the cabinet.
6
Single Door Vertical Cooler
HB80
Page 7
OPERATION
2
2.1Cabinet Operation
Connect the cooler to the mains power supply and check operation of the refrigeration unit and cabinet interior light. After moving the cooler, allow the cabinet to stand for at least 30 minutes before connecting to the power supply.
If the cooler has been disconnected from the power supply for any reason, allow about 10 minutes before switching it back on. This allows the refrigeration system pressure to equalise before the system is restarted.
Refrigeration Unit
The evaporator fan (inside the cabinet) should operate continuously from the time the cabinet is plugged in. This may be verified by checking air movement inside the cabinet. The thermostat will click when it cycles on and off.
Cabinet Light
The cabinet interior light is controlled by the light switch beside the thermostat knob inside the cabinet. The fluorescent lamp will require a period of time to stabilise following initial start up. See page 10 for instructions on replacing the fluorescent lamp.
HB80
Single Door Vertical Cooler
7
Page 8
OPERATION
2
2.2Loading
The cooler should be left running for 30 minutes to allow the cabinet to cool down before loading with product. When loading the cabinet shelves with product:
•Allow air space around all the product, for even cooling and efficient operation of the cooler.
•Do not exceed a maximum of 30 kg per shelf.
•Do not allow products to overhang the front or rear of the shelves, as this will effect air flow.
•Do not obstruct air flow from the evaporator fan.
8
HB80
Single Door Vertical Cooler
Page 9
OPERATION
2
2.3Temperature Adjustment
The storage temperature of the cooler can be regulated to suit different ambient temperature by turning the thermostat knob, located inside the cabinet (see Figure 2 below).
The thermostat knob is graduated from 0 through to 6, with 1 being the warmest and 6 being the coldest. The normal temperature controller setting is between 3 and 5.
•To make colder - turn the thermostat knob clockwise.
•To make warmer - turn the thermostat knob anti-clockwise.
Note: Turning the knob to ‘0’ will switch the refrigeration unit OFF.
Thermostat Knob
HB80
Single Door Vertical Cooler
Light Switch
Figure 2: Thermostat Knob
9
Page 10
MAINTENANCE
3
3.1Cabinet Light
The cabinet interior light is fitted with a 5 Watt fluorescent lamp. To replace the lamp:
1.Disconnect the cabinet from the mains power supply.
2.Remove the light cover by carefully bending out the side clips.
3.Pull the fluorescent lamp out of the lamp holder.
4.Replace with a maximum 5 Watt fluorescent lamp.
5.Carefully align the side clips on the light cover and fit back into
place.
6.Reconnect the cabinet to the mains power supply.
Fluorescent Lamp
Lamp Holder
10
Figure 3: Replacing the Fluorescent Lamp
HB80
Single Door Vertical Cooler
Page 11
MAINTENANCE
3
3.2Cleaning
Disconnect the cabinet from the mains power supply before cleaning.
•When necessary, wipe both the interior and exterior of the cabinet with a damp cloth.
•Do NOT use abrasive or corrosive cleaners or boiling water to clean the cabinet.
•Do NOT flush the cabinet with water.
•Clean the door gasket once every three months.
•The condenser coil on the rear of the cooler should be lightly brushed to remove any dust build up.
Important Note:
Many commercially available cleaning products contain solvents that may attack the plastic components of this product and cause them to crack. It is important to use only warm water and a small amount of detergent when cleaning this cooler.
3.3Advanced Servicing
Advanced servicing should be carried out by an authorised service agent. Detailed service and spares information is available in the HB80 Operating and Service Manual (P/No. MAN6820).
HB80
Single Door Vertical Cooler
11
Page 12
MAINTENANCE
3
3.4Contact Addresses
New Zealand (Head Office)
SKOPE INDUSTRIES LIMITED PO Box 1091, Christchurch New Zealand Freephone: 0800 947 5673 Fax: (03) 983 3896 E-mail: enquiry@skope.co.nz Website: www.skope.co.nz
Australia
SKOPE AUSTRALIA PTY LTD A.C.N. 000 384 270 PO Box 7543, Baulkham Hills B.C. NSW 2153, Australia Freephone: 1800 121 535 Fax: 1800 121 533 E-mail: enquiry@skope.com.au
Website: www.skope.com.au
12
HB80
Single Door Vertical Cooler
Loading...