Haier GV100REMB, GV150REMB, GV200REMB, GV300REMB, GV100RNF User Manual

...
Page 1
User Manual
Haier Solar Water Heater
Models
GV100REMB GV150REMB GV200REMB GV300REMB
GV100RNF GV150RNF GV200RNF GV300RNF
Please read through the manual before use. Please keep the manual for future reference.
Table of Contents
Safety cautions ..........................2
Product features ........................3
Installation instructions ..........3-8
Troubleshooting ........................8
Operation instructions ...............9
Packing list ................................9
Guarantee ..........................10-11
Page 2
Safety cautions (please read the cautions before use)
Description of symbols
Behaviors that
Prohibit
are prohibited
Warning
Warning! Improper operation of the following may lead to personal injury or even death!
Do not touch glass vacuum tube, pipes and valves for supplying hot
Prohibit Prohibit
water during use to avoid being burned.
Please feel the water temperature by hand before use to make sure of
Warning
proper water temperature while in use
Caution! Improper operation of the following may lead to personal injury or even death or property loss!
Please do not use the hot water in the heater for drinking or similar
Prohibit
purposes. To guarantee effectiveness, do not
feed water to the heater several times
Caution
within one day in case of insufficient sunlight exposure.
The glass vacuum tubes can withstand a low temperature of -70
Warning
when they are not filled with water. When the auxiliary heating device is not to be used, on continuous cloudy days in winter or when the tubes are covered by snow, be sure to keep the water tank full of water and replace the cold water in the tank frequently (every 2 days). Otherwise the water retained in the tank will cause the vacuum tubes to break.
When the heater with auxiliary electric heating function is used, ensure the
Prohibit
auxiliary electric heater and electric heating accompanying strap are in OFF state.
This is a zero pressure system and care has to be taken that there is no pressure builtup inside the tank. Install a vent pipe as indibated earlier. Maximum water head of the overhead tank should be 4 meters.
When there is no water inside the system or when the system is not in use for more than 2-3 days, cover the vacuum tubes with an opaque cover, so that light will not pass to the tubes.
The vacuum tubes, being fragile, should be handled with care and should be protected from any object falling on the tubes after installation.
2
Directions that must be followed
Warning
Warning
o
C
Warning
Caution
- Suggestions -
Directions that
Caution
must be noted
Personnel other than professional maintenance staff are prohibited from repairing, maintenance, dismantling or altering the water heater without authorization.
The glass vacuum tube shall not be exposed for a long period without water inside after installation to avoid the shortening of the service life. If it cannot be used immediately, it shall be covered.
The water heater is equipped with a special venting pipe and overflow pipe. To ensure normal operation, never refit or plug their outlets. Otherwise the water tank will shrink.
Water shall be fed in early morning or at night when the sunligth is insufficient. The water feeding after sunlight exposure of the glass vacuum tube will cause an explosion of the pipe.
The source of the energy for the water heater is solar energy. So it may be incapable of being used normally under cloudy, rainy and snowy weather conditions due to the failure to reach desired water temperature because of the insufficient sunlight exposure. If there is no electric heating as an auxiliary energy source, it may be unable to be used normally.
Page 3
Product features Technical parameters Installation instructions
Product features
1. Inner cylinder made of 445 J1M stainless steel The inner cylinder of the water tank adopts sanitary 445 J1M stainless steel, featuring
strong corrosive resistance and durability.
2. High efficiency & energy-saving thermal insulation With intergrated polyurethane foam insulation for solar water heaters, realize good heat
preservation and minimize heat loss.
3. PCM color steel plate outer shell of water tank PCM color steel plate sheet boasting outstanding corrosion resistance, oxidation
resistance and weather ability is the first choice for outdoor protective materials.
4. Tower type frame The tower type frame, made of carbon steel by means of spray processing, has the
advantages of a stable structure, attractive apperance and corrosion resistance.
Technical parameters
Model
Specifications of the glass vacuum tubes
Frame form
Number of the glass vacuum tubes
Aperture area
Usable water
Electric auxiliary heating
GV100REMB
1.51m
GV150REMB GV200REMB GV300REMB GV100RNF GV150RNF GV200RNF GV300RNF
φ 58mm x 1800mm, all-glass vacuum tube collector
Horizontal 35
12 16 22
2
1500W/220V; 1650W/230V
2.02m
2
2.80m
2
Note: The deviation of the aperture area is 3% The permitted error limit of other parameters is ± 10%.
Installation instructions
Selection of installation location
1. The water heater shall be installed within the lightening protected area of a building in locations prone to lightening strikes.
2. The orientation of the water heater to be installed:
o
10
south by east and 15o south by west in the
Northern Hemisphere;
o
north by west and 15o north by east in the
10 Southern Hemisphere.
3. There must be no shielding object in front of the installation location of the water heater. If an object exists, the space between the heater and the objective shall be more than L,
30 16 22 3012
2
3.83m
300L 150L 200L 300L100L100L 150L 200L
o
1.51m22.02m22.80m23.83m
2
(wherein: H- height of the shielding objective;
α- local latitude)
3
Page 4
Installation instructions
Exterior and installation dimensions of horizontal water heater
Exterior dimensions
Models
GV100REMB GV100RNF
GV150REMB GV150RNF
GV200REMB GV200RNF
GV300REMB GV300RNF
(unit:mm)
A BH D
1095 1390 930 1710
1480 1390 1235 1710
1957 1390 1690 1710
2597 1390 2295 1710
Note: The permitted error limit of the parameters above is ±10%.
H
Installation dimensions
(unit:mm)
A
B
Diagram of appearance structure
The diagram subject to GV150REMB is for reference only
4
D
/ Over flow hole / air supply hole
Page 5
Installation instructions
Frame assembly
Please see the related paper in the frame package for the diagram of the frame and packing list.
Frame fixation
1. For horizontal water heaters, it is recommended to fix the feet of the heater onto the foot
foundation with embedded iron parts or make a concrete brick with expansion bolts and then fix the feet of the heater to the expansion bolts.
2. Adjust the height of the frame by the hard waterproof cushion to keep the horizontal tank
and each foot evenly weighted.
Notice:
1. Make sure that the feet all closely contact the supporting floor without foot suspension to avoid damage of the product due to frame deformation.
2. Please use the steel wire to firmly fasten the tank and frame if in a location where typhoons frequently occur.
3. The water heater shall be stably and firmly installed to avoid severe damage or accident due to harsh weather conditions.
Tank installation
1. Unpacking the tank, rip off the protection film. Uninstall the nut and cushion.
2. Place tank onto tank bracket cradle, inserting protruding bolts into holes, fasten with nuts.
Installation of Solderless Pipe Head
Outer casing
Inner wall
Do not apply force along the axial direction of the fittings
Water inlet and outlet pipe
Do not rotate the tank pipe ends
During installation, use a wrench to fasten the tank pipe end
1. Pipe fitting is connected to water pipe with a
solderless connection.
2. Outlet pipe and water inlet pipe both use
solderless structure. To install, use a wrench to secure the water tank pipe head. In order to avoid damaging the seals, do not rotate water tank pipe head and do not apply force along the axial direction of the pipe.
3. When installing the water inlet and outlet pipe, first
use a wrench to secure the water tank pipe head, then unscrew the plastic cap and use inner ratchet teeth to directly connect to the PEX pipe. Before installation, check that the gasket ring of the water inlet and outlet pipe is intact.
Notice:
1. Rip off the protection film after installation to avoid the destroy of the tank, and please do not use the sharp tool.
2. Leave nuts loose since some adjustment may be necessary after fitting tubes.
3. When assembling the water tank, keep the center line of the vacuum tube connecting holes parallel with the diagonal pillar of bracket.
4. The inlet and outlet of the water tank can be also used as the drain.
5
Page 6
Installation instructions
Installation of vacuum tubes
1. Keep the tubes out of the sunlight before assembling the tubes to avoid being burned;
2. The vacuum end use detergent or water soaked (Figure A);
3. Insert the tubes into the seal ring with even pressure and a twisting motion. The
resultant force direction shall be consistent with the axial direction of the vacuum tubes;
4. Place the tubes into the tail support of the frame (Figure B) and then fix the tube onto
the tail base (Figure C);
5. Insert the tube into the seal ring at the depth of around 1cm, push the heat insulation
ring to the water tank hole for sealing (Figure D);
6. While assembling, install one tube on each end of the heater tank respectively first, so
that the heater tank and frame are positioned as a whole.
Seal ring
Heat insulation ring
Vacuum tube
A
Vacuum tube Tail base Tail support
C
Notice:
1. Check whether the seal rings in tank holes are sufficiently installed and whether the sealing location is clean and free from foreign matters and damage.
2. Make the pipe end wet before insertion for easy assembly.
Installation of electric heater and Operation instructions
Please refer to the Operation Manual of Solar water heater controller Model HR-QBJ1-KSD in the controller package.
B
D
Tail support
Tail base
Seal ring
Heat insulation ring
6
Page 7
Installation instructions
Precautions on pipeline installation
1. Any alteration to the structure of the solar
water heater may cause problems in use.
2. There are five ways to connect the water
pipe to the room: flue, vent hole, through­ hole in the wall, pipe well for solar pipes and embedded sleeves, wherein the former three types are commonly used. Before installation, the installation staff will consult the entry form and installation location of the pipe in a comprehensive way and in consideration of your convenience. A slope in the through-wall must be ensured during pipeline layout, and sealing shall be guaranteed to prevent the entry of rain or odors.
3. Keep the smoothness of the air pipe to
prevent the blockage of impurities, which may lead to collapse and deformation of the water tank under suction when using water.
4. Do not install a valve in the overflow
pipeline to ensure that the flood signal can be sent out rapidly and accurately.
5. To avoid the return of water in the tank, a non-return valve shall be installed at the joint
of the water upward/downward pipes and the tap water.
6. The installation project should be confirmed by our professional service personnel when
installing several sets of the series of the products.
Diagram of pipeline installation
Over flow hole/
Electric heating tube (optional)
Inlet/outlet pipe
Mixing valve (hot water)
Accompanying heating strap
Non-return valve
Solenoid valve
Manual valve
Mixing valve (cold water)
Sensor
Electric heating wire
Sensor wire
Outdoor
Indoor Controller
Solenoid valve wire
(optional)
Plug
Tap water
The diagram subject to GV150REMB if for reference only.
Diagram of pipeline installation if there is no controller
Overhead Tank
Cold water
Cold Water
Air pipe
Height of air pipe should be higher than the level of overhead tank
Hot Water
7
Page 8
Installation instructions Troubleshooting
Connection of water supply pipes when the solar water heater coexists with other water heaters
To solar water tank
Tap water
Cold water pipe
Mixing valve
Non-return valve
Other water heater
Hot water pipe
Non-return valve
Manual valve
Mixing valve
Non-return valve
Solar energy hot
Warning
Please install another not-return valve on the cold and hot water pipes respectively if the solar heater coexists with other water heaters so as to avoid accidents caused by water returned to the solar water tank through hot water pipe due to high pressure in the tanks.
Notice: Improper operation of the water heater may lead to serious burns. When using the heater, do not make the high-temperature water of the nozzle aim directly at the body, mix the cold and hot water before use.
Troubleshooting
Phenomena Possible causes Solutions
No water supply
No water from the overflow pipe
The temperature is not high enough
The tank is empty
The pipeline or the connector falls off or is blocked
In the winter, water in the feeding/ outgoing pipe may become frozen
The vacuum tube is damaged
Tap water supply stopped or low water pressure
Pipeline or connector may become broken
In the winter, water in the feeding/ outgoing pipe may become frozen
In bad weather or winter when the sun is relatively low, the sunlight time is short, atmosphere quality is poor, and sunshine radiation energy is insufficient
The valve for water supply is loose or damaged
The vacuum tube cannot effectively collect heat due to a blockage in front of it
Dust on the tube
Add water according to the tank
Maintain the pipeline or remove the blockage
Start the accompanying heating strap or wait for natural ice-out
Replace the tube
Wait for normal water supply
Repair or replace the pipeline or connector
Start the accompanying heating strap or wait for natural ice-out
Use auxiliary electric heating as an option
Tighten or replace the valve
Remove the blockage or change the location for installation
Clean the tube surface
8
Page 9
Operation instructions Packing list
Operations
1) Before using water, the manual valve, mixing valve (hot water) and mixing valve (cold
water) should be closed.
2) To fill water, use automatic function on the controller, or open the manual valve.
3) When using manual valve, when water flows from the overflow pipe, it indicates the
water tank is full. Close the manual valve to finish filling water.
4) To use water, open the mixing valve (hot water) and the water comes from the shower
nozzle. If the water is too hot, open the mixing valve (cold water) to adjust the water temperature.
5) After use of water, make sure the manual valve and mixing valves are closed.
Diagram of pipeline installation
Over flow hole/
Electric heating tube (optional)
Inlet/outlet pipe
Mixing valve (hot water)
Accompanying heating strap
Non-return valve
Solenoid valve
Manual valve
Sensor
Electric heating wire
Sensor wire
Outdoor
Indoor
Controller
Solenoid valve wire
(optional)
Plug
Tap water
Electric heating tube (optional)
Inlet/outlet pipe
Water from the tank
Accompanying heating strap
Air supply hole/ Sensor
Electric heating wire
Outdoor
Indoor
Plug
Mixing valve (cold water)
Mixing valve (hot water)
Mixing valve (cold water)
The diagram subject to GV150REMB is for reference only. Refer to 1-5 terms and conditions
Packing list
Main parts
Water tank (PC)
Water tank package
Manual (Copy)
Glass vacuum tube (PC)
Frame (Set)
Controller
GV100RNF
GV100REMB
1
1
12
1
The diagram subject to GV150RNF is for reference only. Refer to 1, 4, 5 terms and conditions
Quantity
GV150RNF
GV150REMB
1
1
16
1
GV200RNF
GV200REMB
1
1
22
1
GV300RNF
GV300REMB
optional
1
1
30
1
9
Page 10
Guarantee
We Offer
5 Year Guarantee on insulated Tank. 2 Year Guarantee on Electrical Controller & Sensor. 2 Year Guarantee on Electrical Heating element. No Guarantee for the breakage of Evacuate glass tubes. Subject to Terms & Conditions
*
Terms & Conditions
1. We will repair or, if found necessary, replace a defective Solar Water Heater or
any component for failure due to manufacturing defects.
2. The “Haier” Solar Water Heater must be installed in accordance with “Haier”
installation instructions.
3. Where failed component or Solar Water Heater is replaced under guarantee:
the balance of the original guarantee period will remain in effect. The repaired/replaced part does not carry a new guarantee.
4. The Guarantee only applies to the solar water heater and therefore does not
cover any plumbing or electrical part supplied by the installer/owner and not an integral part of solar water heater. E.g. Gate valve, Electric heater, Depressurize, etc.
5. The “Haier” Solar Water Heater must be purchased from an authorized Haier
Solar dealer / retailer to be eligible for guarantee coverage.
“GUARANTEE EXCLUSION”
Repair & Replacement work will be carried out as set in the above,but the following exclusions may cause the Solar Water Heater guarantee to become VOID and may incur a service charge and cost part/s of any
1. Where the Solar Water Heater is located in a location/position that does not
comply with Haier installation instructions.
2. Consequential loss either directly or indirectly in any form for any reason what
so ever.
3. Damage to the TANK/AIRVENT due to scaling, when water is hard. The
hardness of the water should not be more than 300 PPM. The chloride level in the water should not be more than 250 PPM.
4. Breakage of evacuated glass tubes for any reason, rust formation on supports
and mounting stand. Improper selection of the model/ Capacity or misuse of any kind.
5. Cleaning of scale deposits inside the evacuated tubes, if the system is
connected to hard water supply. (More than 300 PPM)
6. Damage(s) resulting from exceeding the maximum permissible water pressure
as specified by Haier.
7. Damage(s) resulting from absence the maximum or installation of Air Vent Pipe.
8. Damage(s) resulting from not grounting the supports properly.
9. Heat loss resulting from not insulating the outlet plumbing properly and / or not
providing a horizontal Non-return Valve at the inlet.
10. Non cleaning of payment.
11. Damage to component/s due to atmospheric/environmental conditions.
10
Page 11
Guarantee
Note:” Negative pressure”, if developed inside the Solar Water Heater storage tank, can lead to collapsing of the tank and high pressure, if developed inside the tank, can cause tank leakage. Please note that Negative pressure/ High pressure can develop inside the tank if airvent pipe is not provided or if the airvent pipe is not installed as per the procedure specified in the plumbing instruction. In such cases Haier will not be responsible and the tank replacement will be on a chargeable basis.
Please complete the following details:
Product :
Model no. :
Serial no. :
Puchaser’s name & address :
Dealer’s name & address :
Dealer’s signature :
Cash memo no. :
Date of purchase :
Haier Appliances (India) P.Ltd. B-1/A-14, Mohan Co-operative Industrial Estate, New Delhi-110044 Ph: 011-39496000/30674000 Fax: 011-26971562 Email: info@haierindia.com Website:www.haierindia.com
Service ph:1800-200-9999
The terms of this guarantee applies only to India.
11
Page 12
0040503720
Loading...