Haier ESAM055-C User Manual

0010552362
ESAM055-C
7-8
7-8
9-13
10 10
11-13
1 1 2 4 4 5 5 6
7
14-15
15-16
17
5
2-way
airflow
control paneleasy access filters
6
TEMPERA TURE
65
FAN ONLY
SPEED
POWER
7
8 9
10
MAX COOL
LOWHI
OFFON
Fig. # 1
4
3 2
1
MIN
COOL
7
POWER Turns air conditioner off. SPEED "LOW" Low speed fan operation with cooling or not. SPEED "HI" High speed fan operation with cooling or not.
This automatically controls the temperature of indoor air. Turn the knob so that arrow points to the cooler marks for more moderate cooling.
Normal Fan
1. T urn the SPEED mode switch to the "HI" or the "LOW" setting.
2. Set the thermostat control to the temperature mark "FAN ONL Y".
Normal cooling
1. T urn the SPEED mode switch to the "HI" or the "LOW" setting.
2. Set the thermostat control to the desire temperature (the mid-point is a good starting position). If the room temperature is not satisfactory after a reasonable time, adjust the control to a warmer setting, as appropriate.
Maximum cooling
1. Turn the SPEED mode switch to the "HI" setting
2. Set the thermostat control to the MAX COOL temperature mark.
Quieter operation
1. Turn the SPEED mode switch to the "LOW" setting.
2. Set the thermostat control as needed.
CAUTION:
1
2
Also when you shut off the air conditioner wait for 3 minutes before turning it on again.
3
8
9
short screws 13/32"
wood screws 31/32"
top rail
window seal gasket
10
ASSEMBLE CURTAINS/TOP RAIL
Install top rail with 3 short screws13/32".
Insert the side curtains into the top and bottom rails of the air conditioner. F asten the curtains to the unit with 8 short screws 13/32".
ESAM055-C
3
5
25
3
12
5 2
13
5 1
33
5 1
22
2 7
12
16
9
18
16
3
13
8
11
2
1. This unit is designed for installation in standard double hung windows with actual opening widths of 22 must open sufficiently to allow a clear vertical opening of 14 bottom of the sash to the window stool.
2. If storm window presents interference, fasten a 2 included) (OUTER SILL) to the inner window sill across the full width of the sill. The wood strip should be thick enough to raise the height of the window sill so that the unit can be installed without interference by the storm window frame (STORM WINDOW FRAME) or wood strip (OUTDOORS) to help condensation to drain properly to the outside.
3. Install a second wood strip (approximately 6 same thickness as first strip) in the center of the outer sill flush against the back off the inner sill. This will raise basepan angle .
4. If the distance between STORM WINDOW FRAME and WOOD STRIP MOUNTED ON TOP OF INNER SILL is more than 1 strip are not necessary.
to 36 . The upper and lower sash
from the
wide wood strip(not
long by 3/2 wide and
, two of wood
INNER
SILL
I N D O O R S
WOOD STRIP MOUNTED ON TOP OF INNER SILL
INNER
SILL
I N D O O R S
1 MAX.
WOOD STRIP FOR BASEPAN ANGLE
OUTER
SILL
3/4 CLEARANCE
OUTER
SILL
O U T D O O R S
STORM WINDOW FRAME
O U T D O O R S
LOCATING UNIT IN WINDOW
Open the window and mark center line on the center of the inner sill.
INNER SILL
INDOOR SIDE
CENTER LINE
ATTACH BASEPAN ANGLE
Install the basepan angle behind the inner window sill, with the short side of basepan angle as shown. Use the 2 short screws13/32" provided. The basepan angle helps to hold unit securely in place. Be sure to place basepan angle edge flush against back of inner sill.
INNER SILL
OUTER SILL
SHORT SIDE
OUTSIDE
BASEPAN ANGLE
SHORT SCREW13/32"
CENTER LINE
INSIDE
8
8
12
INSTALL THE AIR CONDITIONER IN THE WINDOW
Carefully lift the air conditioner and slide it into the open window. Make sure the bottom guide of the air conditioner drops into the notches of the basepan angle. While steadying the air conditioner ,carefully bring the window sash down behind the upper guide of the air conditioner.
WINDOW FRAME
UPPER GUIDE
ABOUT 1/4
INSTALL THE SEAL GASKET AND SASH LOCK
Extend the side curtains to fill the window opening using 4 wood screws 31/32" to secure them. Cut the seal gasket to the window width. Stuff the sash seal between the glass and the window to prevent air and insects from getting into the room. Fasten the basepan angle, using a short screw13/32".
BASEPAN ANGLE
SHORT SCREW13/32"
WOOD SCREW31/32"
BOTTOM GUIDE
BASEPAN ANGLE
WINDOW SEAL GASKET
13
TEMPERATURE
6
5
7
4
8
3
9
2
10
1
MAX
MIN
COOL
COOL
FAN ONLY
LOW
PEED
OFF
POWER
Always unplug your air conditioner before cleaning.
The air filter behind the front grille should be checked and cleaned at least once every 2 weeks or more often if necessary.
To remove:
1. Open the inlet grille downward by pulling out the top of the inlet grille.
2. Remove the air filter from the front grille assembly by pulling the air filter up slightly.
3. Clean the filter with warm, soapy water below 40oC(104oF).
4. Rinse and gently shake the water from the filter and let it dry before replacing it.
DO NOT use your air conditioner without the air filter in place.
To clean the front panels or the cabinet DO NOT use harsh chemicals, abrasives, ammonia, chlorine, bleach, concentrated detergents, solvents or metal scouring pads.
Always use a soft cloth dampened with water or mild soap and water solution to wipe the front of the cabinet.
14
15
(see page 7)
(see page 13)
16