Haier ESA41J Service Manual

Model No. ESA41J
SERVICE MANUAL
Order No.$&69
Haier Group
Feature
Top Discharge Airflow Pattern
Modern Family-look Design 3 Coo l Settings, 3 Fan Settings
Easy-to-ins tall Mounting Kit
Easy-Access Washable Filter
Digital Time & Temperature Display
24 Ho ur on/off Timer
©2009 (Qingdao Haier Air Conditioner General corp.,Ltd)
All right reserved .Unauthorized copying and distribution is a violation of law
Thi
s service information is
designed for experienced repair technicians only and is not designed for use by the general public.
It
does not contain warnings or c
au
tions to advise non-technical individuals of potential dangers in attempting to service a product. Products powered by electricity should be serviced or repaired only by experienced professional technicians. Any attempt to service or rep
air the product or products dealt with in this service information by anyone else could result in serious injury or death
WARNING
ON/OFF
MODE
SPEED
TIMER
TEMP/TIME
TEMP/TIME
1. Product Code Illumination and Series introduction.......................................
2. Specifications....................................................................................................
3. Safety and Precaution.......................................................................................
4
4. Warning and Cautions.......................................................................................
5
5. Installation and Accessory Parts......................................................................
6
6. Parts and Functions.........................................................................................
14
7. Abnormity Diagnose.........................................................................................
18
8. System Flow Chart...........................................................................................
20
9. Circuit Diagram................................................................................................
21
10. Wiring Diagram..............................................................................................
23
Table of Contents
2
3
ESA412J Table of Contents
Domestic Air Conditioner
1
Indoor air state outdoor air state
No. Operating condition
D.B. ć W.B. ć D.B. ć W.B. ć
1 Nominal cooling 26.7 19.4 35 23.9
1. Product Code Illumination and Series Introduction
1). Model identification:
A: Abbre viation of Energy Star
B: The type of refrigerant
4:R410A
C: Nominal cooling capacity (BTU/h) with the first two numbers based on one thousand unit
D: Desigh code
Examples:
ESA412J
It represents remote control window air condition r. Cooling capacity is 12000BTU/h and the power supply is 115V/60Hz.
2). Standard situation/conditions
ESA
ƶƶƶ
A
CD
ESA412J Table of Contents
Domestic Air Conditioner
2
ƶ
B
2. Specification
Item Unit ESA412J
Cooling capacity
BTU/h 12000
Heating capacity /
Power supply Ph,V, Hz 1, 115, 60
Power input W 1110
Running current A 10Cooling
EER
BTU/(h.w) 10.8
Power input W /
Running current A / Heating
COP
/
Indoor side dB(A) 62
Sound Level
Outdoor side
67
Height inches
14 3/8
Width inches
19
Case
Depth
inches
18 1/8
Height inches
17
Width inches
21 1/4
Packaging
dimensions
Depth
inches
22
Net lbs 65
Weight
Gross
lbs 73
Type Rotary
Model /
Compressor
Running cap. For comp μF
60μF/250
V
Hi-Pressure Psig 570
Pressure
Low-Pressure
Psig 240
Model R22 or R410A R410A
Refrigerant
Charge
OZ 26.8
Indoor unit / centrifugal
Type
Outdoor unit
/ axial
Fan
Fan Speed
Indoor unit r/min
Air volume CFM 270/250/220
Moisture removal Pints/hr 3.5
1460±30/1290±30/1160±30
ASD073SW-H3AG
ESA412J Specification
Domestic Air Conditioner
3
BTU/h
BTU/(h.w)
dB(A)
ESA412J Safety and Precaution
Domestic Air Conditioner
4
3. Safety and Precaution
WARNING:
Following these basic precautions will reduce the risk of fire ,electrical shock ,injury or death when using your air conditioner .
1) Air conditioner must be connected to proper electrical outlet with the correct electrical supply .
4)DO NOT USE AN ADAPTER OR AN EXTENSION CORD.
5)When installing your air conditioner in a window,make sure the window is strong enough to hold the weight of the air conditioner.You also want to secure and correctly install your air conditioner property to prevent it
from falling.Extra brackets or support may be required depending on your window.
3) DO not use if power cord is frayed or damage . Also avoid using if there are cracks or abrasion damage along the length ,plug or connector .
6) Do not black airflow inside or outside the air conditioner with blinds,drapes,protective covers,shrubs or bushes.
9)Always unplug the air conditioner before servicing it or moving it .
7)Be careful of sharp edges on the front and rear fins of the unit that could cut and cause serious injury.
8)Be careful when lifting the air conditioner to install or remove the unit . Always use two or more people for this .
2) Proper grounding must be ensured to reduce the risk of shock and fire . DO NOT CUT OR REMOVE THE GROUNDING PRONG. If you do not have a three-prong electric receptacle outlet in the wall, have a certified electrician install the proper receptacle . The wall receptacle MUST be properly grounded .
ESA412J Warning and Cautions
Domestic Air Conditioner
5
4.Warning and Cautions
WARNINGS:
Following the safety messages is very important.
These messages can save you from being injured or killed. Warning symbols alert you to be
This room air conditioner must be grounded. Grounding reduces the risk of electric shock by providing an escape wire for the electric current. The power cord has a grounding wire with a grounding plug . Plug it into an outlet that is properly installed and grounded.
Improper use of the grounding plug can result in a risk of electric shock. Call a qualified electrician if you don’t understand the grounding instructions or if you are not sure
if the air conditioner is properly grounded. If the wall outlet is not grounded, please contact an electrician to have it replaced with a proper grounded outlet.
We strongly advise against using an adapter plug.
careful and means Danger . Always follow instructions to be safe and reduce chances of injury or death . Warning and Danger signs will precede safety messages.
Electrical Safety
GROUNDING:
WARNING:
Do not, under any circumstances, cut or remove the third (ground) prong from the power cord.
Adapter Plug:
ESA412J Installation and Accessory Parts
Domestic Air Conditioner
6
5. Installation and Accessory Parts
Check the following before you install your air conditioner:
1) The unit is free of all obstructions inside and outside the room e.g. drapes, curtains, furniture, plants,
shrubs, bushes, trees, other structures like building, garage etc.
Air conditioner must have clear unobstructed airflow through the condenser to remove the heat.
2) The window is strong enough to hold the weight of the air conditioner. Extra brackets or supports may be
needed depending on your windows. Brackets or supports not not provided in all models.
3) The window sill and track are strong enough to hold the weight of the air conditioner.
4) The wall is strong enough to hold the unit. Extra brackets or supports may be needed depending on the
wall. (Brackets or Supports not provided in all models).
5) There is adequate and proper power supply near the air conditioner.
6) DO NOT use adopter plugs.
7) DO NOT use extension cords.
8) DO NOT cut or remove the ground prong.
9) DO NOT modify the plug or the electrical wall outlet in any way. If plug does not fit the electrical outlet
have a certified electrician do the necessary change.
10) NOT connect electrical power to the unit before installation.
11) DO NOT use if power cord is worn out, hayed or damage. Avoid using if here are cracks or abrasion
damage along the length, plug or connection.
12) DO NOT install into any existing cabinet or sleeve which does not have ride and top air vents.
13) Be careful of exposed sharp edges of the cabinet and sharp coils (fins) on the back of the unit that could
cut and cause serious injury.
ESA412J
Domestic Air Conditioner
7
Installation and Accessory Parts
"
#
A. Width
B. Height
MODEL
Dimension
A(inch) Min
24 ”(62.2cm)
38”(96.5cm)
149/16”(37cm)
ESA412J
A(inch) Max
B(inch) Max
1. Place the top channel on the top of the air conditioner, lining up the holes in the top channel with the holes in the top of the air conditioner.
2. U
sing four ©c ” screws, attach the top channel to the air conditioner.
Install Top Channel
B
NOTE:Your model may differ from the one shown.
A. ©c ” screws B. Top channel
Prepare Air Conditioner for Installation
Window Installation
Window opening measurements:
Loading...