Haier Esa412j Owner's Manual

ROOM AIR CONDITIONER
Use & Care Guide
ACONDICIONADOR DE AIRE PARA HABITACIÓN
Manual de Uso y Cuidado
CLIMATISEUR DE PIÈCE
Guide d’utilisation et d’entretien
Model: ESA406J ESA406J-L ESA406J-T ESA408J ESA408J-L ESA408J-T ESA410J ESA410J-L ESA410J-T ESA412J ESA412J-L ESA410J-E
No.0010529626
For questions about features, operation/performance, parts,
accessories or service call: 1-877-337-3639
Si tiene preguntas respecto a las características, funcionamiento,
rendimiento, partes, accesorios o servicio técnico,
llame al: 1-877-337-3639
Au Canada, pour assistance, installation ou service,
composez le : 1-877-337-3639
TABLE OF CONTENTS
AIR CONDITIONER SAFETY ........................................................3
INSTALLATION REQUIREMENTS.................................................3
Tools and Parts ............................................................................3
Location Requirements ...............................................................4
Electrical Requirements ...............................................................4
INSTALLATION INSTRUCTIONS...................................................5
Unpack the Air Conditioner..........................................................5
Prepare Air Conditioner for Installation........................................5
Prepare Window for Installation...................................................6
Position Air Conditioner ..............................................................7
Complete Installation ..................................................................8
AIR CONDITIONER USE...............................................................9
Starting Your Air Conditioner .......................................................9
ÍNDICE
SEGURIDAD DEL ACONDICIONADOR DE AIRE......................17
REQUISITOS DE INSTALACIÓN.................................................17
Herramientas y piezas................................................................17
Requisitos de ubicación.............................................................18
Requisitos eléctricos..................................................................18
INSTRUCCIONES DE INSTALACIÓN.........................................19
Desempaque el acondicionador de aire....................................19
Prepare el acondicionador de aire para la instalación ..............20
Preparación de la ventana para la instalación............................20
Coloque el acondicionador de aire en su lugar..........................21
Complete la instalación..............................................................22
CÓMO USAR EL ACONDICIONADOR DE AIRE .......................23
Cómo poner en marcha su acondicionador de aire...................23
Using the Remote Control...........................................................11
Changing Air Direction ................................................................12
Normal Sounds............................................................................12
AIR CONDITIONER CARE ...........................................................12
Cleaning the Air Filter .................................................................12
Cleaning the Front Panel.............................................................13
Annual Maintenance....................................................................13
TROUBLESHOOTING ..................................................................13
ASSISTANCE OR SERVICE..........................................................15
In the U.S.A. ...............................................................................15
In Canada ...................................................................................15
WARRANTY ..................................................................................16
Cómo usar el control remoto .....................................................25
Cómo cambiar la dirección del aire ...........................................26
Sonidos normales.......................................................................26
CUIDADO DE SU ACONDICIONADOR DE AIRE.......................26
Limpieza del filtro de aire ...........................................................26
Limpieza del panel frontal ..........................................................26
Mantenimiento anual..................................................................26
SOLUCIÓN DE PROBLEMAS......................................................27
AYUDA O SERVICIO TÉCNICO...................................................28
En los EE.UU. .............................................................................28
En los CANADÁ
GARANTÍA.....................................................................................29
. .........................................................................28
TABLE DES MATIÈRES
SÉCURITÉ DU CLIMATISEUR ...................................................31
EXIGENCES D’INSTALLATION...................................................31
Outillage et pièces......................................................................31
Exigences d’emplacement.........................................................32
Spécifications électriques .........................................................32
INSTRUCTIONS D’INSTALLATION ............................................33
Déballage du climatiseur............................................................33
Préparer le climatiseur pour l’installation...................................34
Préparation de la fenêtre pour l’installation ...............................34
Positionnement du climatiseur...................................................35
Achever l’installation ..................................................................36
UTILISATION DU CLIMATISEUR................................................37
Mise en marche du climatiseur...................................................37
2
Utilisation de la télécommande...................................................39
Changement de direction de l’air.................................................40
Sons normaux ............................................................................40
ENTRETIEN DU CLIMATISEUR...................................................40
Nettoyage du filtre à air ..............................................................40
Nettoyage du panneau avant.....................................................40
Entretien annuel..........................................................................40
DÉPANNAGE.................................................................................41
ASSISTANCE OU SERVICE.........................................................42
Aux États-Unis............................................................................42
Au Canada..................................................................................42
GARANTIE.....................................................................................43
AIR CONDITIONER SAFETY
Your safety and the safety of others is very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.
This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”
These words mean:
You can be killed or seriously injured if you don't immediately
DANGER
follow instructions.
WARNING
instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
IMPORTANT SAFETY INSTRUCTIONS
You can be killed or seriously injured if you don't follow
WARNING:
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
To reduce the risk of fire, electrical shock or injury when using your air conditioner, follow these basic precautions:
Do not use an extension cord.
Unplug air conditioner before servicing.
Use two or more people to move and install air conditioner.
SAVE THESE INSTRUCTIONS
INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.
Parts supplied:
Check that all parts are included in parts package.
Tools needed
Phillips head screwdriver
Flat-blade screwdriver
Scissors
Level
Socket wrench and sockets
Tape measure
Cordless drill and 1/8” bit
Pencil
Pliers
Adjustable wrench
A
B
E
C
D
A. Top channel B. Foam seal C. Side brackets (2) D.Window lock bracket E. ⁄” screws : ESA410J,ESA410J-L(4) ESA412J,ESA412J-L(4) ESA410J-T,ESA410J-E(4)
F
G
H
ESA406J,ESA406J-L(3) ESA408J,ESA408J-L(3) ESA406J-T,ESA408J-T(3) F. ⁄” screws (9) G. Side curtains (2) H. Side curtain frames (2) I. Remote control
ON/OFF
MODE
SPEED
TIMER
TEMP/TIME
TEMP/TIME
I
3
Location Requirements
IMPORTANT: Observe all governing codes and ordinances. Check the location where the air conditioner will be installed.
Make sure you have everything necessary for correct installation. The location should provide:
Grounded electrical outlet within 4 ft (122 cm) of where the power cord exits the air conditioner. (For model ESA406J,ESA408J,ESA406J-L,ESA408J-L, ESA406J-T,ESA408J-T electrical outlet can be grounded within 6 ft (183 cm))
NOTE: Do not use an extension cord.
Free movement of air in room to be cooled.
A large enough opening for the air conditioner. Installation
parts are supplied for double-hung windows.
Adequate wall support for weight of air conditioner. Air conditioner weighs 48.3 lbs to 76 lbs (21.9 kg to 34.5 kg).
NOTE: Cabinet louvers must not be obstructed. Air must be able to pass freely through the cabinet louvers.
A
Electrical Requirements
The electrical ratings for your air conditioner are listed on the model and serial number label. The model and serial number label is located either on the side or back of the air conditioner cabinet or behind the front grille.
Specific electrical requirements are listed in the chart below. Follow the requirements for the type of plug on the power supply cord.
Window Installation
Window opening measurements:
A
MODEL
Dimension
ESA406J ESA406J-L ESA408J ESA408J-L ESA406J-T ESA408J-T
A(inch) Min 25”(63.5cm) A(inch) Max
B(inch) Min
36”(91.4cm) 38”(96.5cm) 13⁄”(34cm) 14⁄”(37cm)
4
A. Cabinet louvers
B
A. Width
B. Height
ESA410J ESA410J-L ESA412J ESA412J-L ESA410J-T ESA410J-E
24½”(62.2cm)
Power Supply Cord Wiring Requirements
115-volt (103.5 min. to 126.5 max.)
0 to 12 amps
15-amp time-delay fuse or circuit
breaker
Use on single outlet circuit only.
Recommended Grounding Method
This air conditioner must be grounded. This air conditioner is equipped with a power supply cord having a 3 prong grounding plug. The cord must be plugged into a mating, grounded 3 prong outlet, grounded in accordance with all local codes and ordinances. If a mating outlet is not available, it is the customer’s responsibility to have a properly grounded 3 prong outlet installed by a qualified electrical installer.
It is the customer’s responsibility:
To contact a qualified electrical installer.
Power Supply Cord
B
NOTE: Your air conditioner’s device may differ from the one shown.
A
RESET
TEST
A. Test button
B. Reset button
This room air conditioner is equipped with a power supply cord required by UL. This power supply cord contains state-of-the-art electronics that sense current leakage. If the cord is crushed, the electronics detect current leakage and power will be disconnected in a fraction of a second.
To test your power supply cord:
1. Plug power supply cord into a grounded 3 prong outlet.
2. Press RESET (on some devices, a green light will turn on).
3. Press TEST (listen for click; Reset button will trip, and on some devices, a green light will turn off).
4. Press and release RESET (listen for click; Reset button will latch, and on some devices, a green light will turn on). The power supply cord is ready for operation.
NOTES:
The Reset button must be pushed in for proper operation.
The power supply cord must be replaced if it fails to trip when
the test button is pressed or fails to reset.
Do not use the power supply cord as an off/on switch.
A damaged power supply cord must be replaced with a new
power supply cord obtained from the product manufacturer and must not be repaired.
The power supply cord contains no user serviceable parts. Opening the tamper-resistant case voids all warranty and performance claims.
INSTALLATION INSTRUCTIONS
Unpack the Air Conditioner Prepare Air Conditioner for Installation
Remove Packaging Materials
Remove and dispose of/recycle packaging materials. Remove tape and glue residue from surfaces before turning on the air conditioner. Rub a small amount of liquid dish soap over the adhesive with your fingers. Wipe with warm water and dry.
Do not use sharp instruments, rubbing alcohol, flammable
fluids, or abrasive cleaners to remove tape or glue. These products can damage the surface of your air conditioner.
Handle the air conditioner gently.
Install Top Channel
1. Place the top channel on the top of the air conditioner, lining up the holes in the top channel with the holes in the top of the air conditioner.
2. Using four ⁄” screws, attach the top channel to the air conditioner.
(For model ESA406J,ESA408J,ESA406J-L,ESA408J-L, ESA406J-T,ESA408J-T three ⁄” screws is needed to attach the top channel to the air conditioner. )
5
NOTE: Your model may differ from the one shown.
B
A. ⁄” screws B. Top channel
Install Side Curtains
NOTE: Attach curtains to the air conditioner before placing the air
conditioner in window.
1. Place the tabbed side of the side curtain in the track on the right-hand side of the air conditioner cabinet.
3. Slide the side curtain frame into the top channel on the top of the air conditioner and the track on the bottom of the air conditioner.
4. Slide the side curtain frame as close to the air conditioner as necessary to lock the side curtain to the frame.
5. Repeat above steps for the left-hand side curtain and
frame.
A
B
A. Tabbed side of side curtain B. Lock edge side of side curtain
2. Slide the side curtain down the track until the curtain is aligned with the top and bottom of the air conditioner cabinet.
Prepare Window for Installation
1. Measure the width of the window opening.
2. Mark the center line on the inside windowsill.
A
B
A. Width of window opening B. Center line
6
Position Air Conditioner
NOTES:
Handle the air conditioner gently.
Be sure your air conditioner does not fall out of the opening
during installation or removal.
The place where the power cord exits the air conditioner should be no more than 4 ft (122 cm) from a grounded outlet.
(For model ESA406J,ESA408J,ESA406J-L,ESA408J-L, ESA406J-T,ESA408J-T electrical outlet can be grounded within 6 ft (183 cm))
Do not block the louvers in the front panel.
Do not block the louvers on the outside of the air conditioner.
1. Center the air conditioner in the window. Lower the window sash behind the top channel to hold the cabinet in place
NOTE: Your model may differ from the one shown.
3. Slide the side bracket over the screw.
4. Tighten the screw. The side bracket should be resting on the windowsill.
5. Use ⁄” drill bit to drill a starter hole through the holes in the
side bracket and windowsill.
6. Using two ⁄” screws, attach the side bracket to the
windowsill.
B
A
C
A. Side curtain against window channel B. Window sash behind top channel C. Bottom channel in behind windowsill
2. Loosen the screw on the right-hand side of the air conditioner cabinet near the bottom.
7. Repeat for side bracket installation on the left-hand side of the air conditioner.
Attach Side Curtains to Window
1. Pull the left-hand curtain out until it fits into the window
channel.
2. Use a ⁄” drill bit to drill a starter hole through the top hole in
the side curtain and into the window sash.
3. Insert one of the ⁄” screws through the top hole of the lefthand curtain and into the window sash.
4. Repeat for the right-hand curtain.
5. Use a ⁄” drill bit to drill a starter hole through the bottom hole in the side curtain and into the window frame.
6. Insert one of the ⁄” screws through the bottom hole of the left-hand curtain and into the window frame.
7. Repeat for the right-hand curtain.
7
Top View
Bottom View
4. Plug into a grounded 3 prong outlet.
5. Press RESET on the power supply cord. See “Electrical Requirements.”
Complete Installation
1. Insert the foam seal behind the top of the lower window sash and against the glass of the upper window.
A
B
A. Top of lower window sash B. Foam seal
2. Place the window lock bracket as shown. Use a ⁄” drill bit to
drill a starter hole through the hole in the window lock bracket and into the upper window.
3. Attach the window lock bracket to the upper window with one
⁄” screw to secure the window in place.
Notes:Push to open the air outlet before using the air conditioner.
Adjust to desired position.
8
AIR CONDITIONER USE
Operating your air conditioner properly helps you to obtain the best possible results.
This section explains proper air conditioner operation.
IMPORTANT:
If you turn off the air conditioner, wait at least 3 minutes before turning it back on. This keeps the air conditioner from blowing a fuse or tripping a circuit breaker.
Starting Your Air Conditioner
MODE
SPEED
FAN
COOL
ENERGY SAVER
DEHUM
HIGH
MEDONOFF
LOW
TEMP/TIME
POWER
Do not try to operate your air conditioner in the Cool mode when outside temperature is below 61°F (16°C). The inside evaporator coil will freeze up, and the air conditioner will not operate properly.
3. Select mode. See “Mode.”
4. Select fan speed. See “Fan Speed.”
5. Set temperature. See “Temperature.”
Mode
1. Press MODE until you see the indicator light glow for the desired setting.
2. Choose Fan, Cool, Energy Saver or Dehum.
Fan—Only the fan runs. Press SPEED to select High, Med
or Low fan speed. The display shows the current room temperature.
Cool—Cools the room. Press SPEED to select High, Med
or Low fan speed. Press the TEMP/TIME up or down arrow button to adjust the temperature.
Energy Saver—Fan runs only when cooling is needed.
Press SPEED to select High, Med or Low fan speed. Because the fan does not circulate the room air continuously, less energy is used, but the room air is not
circulated as often.
Dehum—Dries the room. The air conditioner automatically
selects the temperature.
NOTE:
Dehum mode should not be used to cool the room.
In Dehum mode,Please do not operate the speed button.
1. Remove the clear plastic film from the control panel.
2. Press POWER to turn on the air conditioner. The Power indicator light will turn on.
POWER
NOTE: When the air conditioner is plugged in, the LED display
will show “88” for 3 seconds. After the air conditioner is turned on for the first time, the display will show the current room temperature and the fan is set to Low speed.
MODE
FAN
COOL
ENERGY SAVER
DEHUM
9
Fan Speed
1. Press FAN SPEED until you see the indicator light glow for the desired setting.
2. Choose High, Med or Low.
High—for maximum cooling
Med—for normal cooling
Low—for minimum cooling
SPEED
2. Press the TEMP/TIME up or down arrow button to change the delay time from 1 hour to 24 hours.
3. After 5 seconds, Timer OFF indicator light will remain on.
Display will show the current room temperature.
To set the Timer to turn on the air conditioner, keeping previous settings:
1. Turn on the air conditioner.
2. Press TIMER. Timer On indicator light will flash. Display will show remaining hours before the air conditioner will turn on.
3. Press the TEMP/TIME up or down arrow button to change the delay time from 1 hour to 24 hours.
4. Timer On indicator light will remain on.
HIGH
MED
LOW
Temperature
Press the TEMP/TIME up arrow button to raise the temperature. Each time you press or hold the TEMP/TIME up arrow button, the temperature will go up 1ºF until it reaches 86°F (30°C).
NOTE: After 5 seconds, the display will show the current room
temperature.
TEMP/TIME
Press the TEMP/TIME down arrow button to lower the temperature. Each time you press or hold the TEMP/TIME down arrow button, the temperature will go down 1ºF until it reaches 61°F (16°C).
NOTE: After 5 seconds, the display will show the current room
temperature.
Timer Delay
To set the Timer for a 1-hour to 24-hour delay until the air conditioner turns off (the air conditioner must be On):
1. Press TIMER. Timer OFF indicator light will flash. Display will show remaining hours before the air conditioner will turn off.
TIMER
ON
To set the Timer to turn on the air conditioner, changing the previous settings:
1. Turn on the air conditioner.
2. Adjust the mode to Fan, Cool, Energy Saver or Dehum.
3. For Fan, Cool or Energy Saver mode, adjust the fan speed to High, Med or Low.
4. Adjust the temperature between 61ºF and 86ºF (16ºC and
30ºC).
NOTE: In Fan mode, the temperature cannot be set.
5. Press TIMER. Timer On indicator light will flash. Display will
show remaining hours before the air conditioner will turn on.
6. Press the TEMP/TIME up or down arrow button to change the
delay time from 1 hour to 24 hours.
7. Timer On indicator light will remain on.
To clear Timer delay program:
NOTE: Air conditioner can be either on or off.
1. Press TEMP/TIME once after it has been programmed.
Display will show remaining time.
2. While the display is showing the remaining time, press TIMER
untill Timer indicator light turns off.
To see or change the remaining time (in hours):
Timer Off :
1. Press TEMP/TIME once after it has been programmed.
Display on the air conditioner control panel will show remaining time.
2. While the display is showing the remaining time, press
the TEMP/TIME up or down arrow button to increase or decrease the time.
3. After 5 seconds, the display on the air conditioner control
panel will show the current room temperature.
Timer On :
1. Display on the air conditioner control panel will show
remaining time.
2. While the display is showing the remaining time, press the
TEMP/TIME up or down arrow button to increase or decrease the time.
10
OFF
`
NOTE: Dots are Braille text for sight Impaired. Remote control may differ in appearance.
ON/OFF
MODE
SPEED
TIMER
TEMP/TIME
TEMP/TIME
Using the Remote Control
Temperature
Press the TEMP/TIME up arrow button to raise the temperature. Each time you press or hold the TEMP/TIME up arrow button, the temperature will go up 1ºF until it reaches 86°F (30°C).
TEMP/TIME
Press the TEMP/TIME down arrow button to lower the temperature. Each time you press or hold the TEMP/TIME down arrow button, the temperature will go down 1ºF until it reaches 61°F (16°C).
TEMP/TIME
Timer
NOTE: One CR2025 battery (included) powers the remote
control. Replace battery after 6 months of use, or when the remote control starts to lose power.
Power
Press ON/OFF to turn on the air conditioner.
ON/OFF
Mode
Press MODE to choose Fan, Cool, Energy Saver or Dehum.
MODE
Speed
Press SPEED to choose High, Med or Low.
SPEED
To set the Timer for a 1-hour to 24-hour delay before the air conditioner is turned off (the air conditioner must be On):
1. Press TIMER. Timer OFF indicator light on the air conditioner control panel will flash.
TIMER
2. Press the TEMP/TIME up or down arrow button to change the delay time from 1 hour to 24 hours.
3. After 5 seconds, Timer OFF indicator light on the air conditioner control panel will remain on.
To set Timer to turn on the air conditioner, keeping previous settings:
1. Turn on the air conditioner.
2. Press TIMER. Timer On indicator light on the air conditioner control panel will flash.
3. Press the TEMP/TIME up or down arrow button to change the delay time from 1 hour to 24 hours.
4. After 5 seconds, Timer On indicator light on the air conditioner control panel will remain on.
To set Timer to turn on the air conditioner, changing the previous settings:
1. Turn on the air conditioner.
2. Adjust the mode to Fan, Cool, Energy Saver or Dehum.
3. For Fan, Cool or Energy Saver mode, adjust the fan speed to High, Med or Low.
11
4. Adjust the temperature between 61ºF and 86ºF (16ºC and 30ºC).
NOTE: In Fan mode, the temperature cannot be set.
5. Press TIMER. Timer On indicator light on the air conditioner control panel will flash. Display will show remaining hours before the air conditioner will turn on.
6. Press the TEMP/TIME up or down arrow button to change the delay time from 1 hour to 24 hours.
7. Timer On indicator light on the air conditioner control panel will remain on.
To clear Timer delay program:
NOTE: Air conditioner can be either on or off.
1. Press TIMER once after it has been programmed. Display on the air conditioner control panel will show remaining time.
2. While the display is showing the remaining time, press TIMER untill Timer indicator light turns off.
To see or change the remaining time (in hours):
Timer Off :
1. Press TEMP/TIME once after it has been programmed. Display on the air conditioner control panel will show
remaining time.
2. While the display is showing the remaining time, press the TEMP/TIME up or down arrow button to increase or
decrease the time.
3. After 5 seconds, the display on the air conditioner control panel will show the current room temperature.
Timer On :
1. Display on the air conditioner control panel will show
remaining time.
2. While the display is showing the remaining time, press the
TEMP/TIME up or down arrow button to increase or decrease the time.
Changing Air Direction
4-Way Air Flow:The air directional louvers let you control the
direction of the airflow to the desired direction.The airflow can be
directed up-down,left-right.
Vent:The Fresh air vent allows the air conditioner to recirculat
inside air,draw fresh air into the room and exhaust stale air to the
outside. (NOTE:For model :ESA410J,ESA412J,ESA410J-L, ESA412J-L,ESA410J-T,ESA410J-E only)
A
B
A. 4-Way Air Flow
B. Vent
Normal Sounds
When your air conditioner is operating normally, you may hear sounds such as:
Droplets of water hitting the condenser, causing a pinging or clicking sound. The water droplets help cool the condenser.
Air movement from the fan.
Clicks from the thermostat cycle.
Vibrations or noise due to poor wall or window construction.
A high-pitched hum or pulsating noise caused by the modern
high-efficiency compressor cycling on and off.
AIR CONDITIONER CARE
Your new air conditioner is designed to give you many years of dependable service. This section tells you how to clean and care for your air conditioner properly.
Cleaning the Air Filter
The air filter is removable for easy cleaning. A clean filter helps remove dust, lint, and other particles from the air and is important for best cooling and operating efficiency. Check the filter every 2 weeks to see whether it needs cleaning.
NOTE: Do not operate the air conditioner without the filter in place.
1. Turn off the air conditioner.
2. Remove the air filter by opening the front panel and removing the air filter.
12
B
A
A. Air filter B. Front panel
3. Use a vacuum cleaner to clean air filter. If the air filter is very dirty, wash it in warm water with a mild detergent. Do not wash the air filter in the dishwasher or use any chemical cleaners. Air dry the air filter completely before replacing to ensure maximum efficiency.
4. Replace the air filter.
5. Close the front panel.
6. Turn on the air conditioner.
Cleaning the Front Panel
1. Turn off the air conditioner.
2. Clean the front panel with a soft, damp cloth.
3. Air dry the front panel completely.
4. Turn on the air conditioner.
Annual Maintenance
Air Conditioner
Your air conditioner needs annual maintenance to help ensure steady, top performance throughout the year. Call your local authorized dealer to schedule an annual checkup. The expense of an annual inspection is your responsibility.
TROUBLESHOOTING
Before calling for service, try the suggestions below to see whether you can solve your problem without outside help.
Air Conditioner Will Not Operate
The power supply cord is unplugged. Plug into a grounded
3 prong outlet. See “Electrical Requirements.”
The power supply cord has tripped (Reset button has popped out). Press and release RESET (listen for click;
Reset button will latch and on some devices, a green light will turn on) to resume operation.
A household fuse has blown, or circuit breaker has tripped. Replace the fuse or reset the circuit breaker. If the
problem continues, call an electrician. See “Electrical Requirements.”
The Power button has not been pressed or the Mode control knob is turned to Off. Press POWER or turn the
Mode control knob to an active setting.
The local power has failed. Wait for power to be restored.
Air conditioner blows fuses or trips circuit breakers
Too many appliances are being used on the same circuit. Unplug or relocate appliances that share the same circuit.
Time-delay fuse or circuit breaker of the wrong capacity is being used. Replace with a time-delay fuse or circuit
breaker of the correct capacity. See “Electrical Requirements.”
13
An extension cord is being used. Do not use an extension
cord with this or any other appliance.
You are trying to restart the air conditioner too soon after turning off the air conditioner. Wait at least 3 minutes after
turning off the air conditioner before trying to restart the air conditioner.
Air conditioner power supply cord trips (Reset button pops out)
Disturbances in your electrical current can trip (Reset
button will pop out) the power supply cord. Press and
release RESET (listen for click; Reset button will latch and on some devices, a green light will turn on) to resume operation.
Electrical overloading, overheating, cord pinching or
aging can trip (Reset button will pop out) the power supply cord. After correcting the problem, press and release
RESET (listen for click; Reset button will latch and on some devices, a green light will turn on) to resume operation.
NOTE: A damaged power supply cord must be replaced with a new power supply cord obtained from the product manufacturer and must not be repaired.
Air conditioner seems to run too much
The current air conditioner replaced an older model. The use of more efficient components may cause the air conditioner to run longer than an older model, but the total energy consumption will be less. Newer air conditioners do not emit the “blast” of cold air you may be accustomed to from older air conditioners, but this is not an indication of lesser cooling capacity or efficiency. Refer to the efficiency rating (EER) and capacity rating (in Btu/h) marked on the air conditioner.
The air conditioner is in a heavily occupied room, or heatproducing appliances are in use in the room. Use
exhaust vent fans while cooking or bathing and try not to use heatproducing appliances during the hottest part of the day. A higher capacity air conditioner may be required, depending on the size of the room being cooled.
Air conditioner cycles on and off too much or does not cool room in cooling mode
The air conditioner is not properly sized for your room. Check the cooling capabilities of your room air conditioner. Room air conditioners are not designed to cool multiple rooms.
The filter is dirty or obstructed by debris. Clean the filter.
There is excessive heat or moisture (open container cooking,
showers, etc.) in the room. Use a fan to exhaust heat or moisture from the room. Try not to use heatproducing appliances during the hottest part of the day.
The louvers are blocked. Install the air conditioner in a location where the louvers are free from curtains, blinds, furniture, etc.
The outside temperature is below 61°F (16°C). Do not try to operate your air conditioner in the cooling mode when the outside temperature is below 61°F (16°C).
The temperature of the room you are trying to cool is extremely hot. Allow extra time for the air conditioner to cool off a very hot room.
Windows or doors to the outside are open. Close all windows and doors.
The Temperature control is not at a cool enough setting. Adjust the TEMP/TIME control to a cooler setting by pressing the minus button to reduce the temperature. Set the Fan Speed control to the highest setting.
Water drips from cabinet into your house
The air conditioner is not properly leveled. The air conditioner should slope slightly downward toward the outside. Level the air conditioner to provide a downward slope toward the outside to ensure proper drainage. See the Installation Instructions.
NOTE: Do not drill a hole into the bottom of the metal base and condensate pan.
14
Loading...
+ 30 hidden pages